Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “temperature sensors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Self-regulating proportionally controlled heating apparatus and technique

A self-regulating proportionally controlled heating apparatus and technique is provided wherein a single electrical resistance heating element having a temperature coefficient of resistance serves simultaneously as a heater and temperature sensor. The heating element is current-driven and the voltage drop across the heating element is monitored and a component extracted which is attributable to a change in actual temperature of the heating element from a desired reference temperature, so as to produce a resulting error signal. The error signal is utilized to control the level of the heater drive current and the actual heater temperature in a direction to reduce the noted temperature difference. The continuous nature of the process for deriving the error signal feedback information results in true proportional control of the heating element without the necessity for current-switching which may interfere with nearby sensitive circuits, and with no cyclical variation in the controlled temperature.

Strange, M. G.↗

Hydrostatic fluid bearing gyro

The design, fabrication, and testing are described of a thermal control assembly capable of precisely controlling the LDG-540 Gyro case temperature at 50 C over an ambient environment range of 23 C and atmosphere pressure to 5 C and a vacuum of 0.00001 torr. The thermal control assembly is a hermetically sealed enclosure about the LDG-540 Gyro with envelope dimensions not to exceed those of the Saturn K8-AB5 Gyro. The heaters are capable of delivery 30 watts at 28 V.D.C. and have dual temperature sensors rated at 750 ohms at 50 C. All six (6) LGD-540 Gyros will be equipped with a fine control heater and a resistance thermometer to monitor the gyro cast temperature. All six gyros will be interchangeable in the thermal control assembly by means of simply assembly techniques.

Brello, E. Y.↗

Passive bias temperature compensation circuit module

A passive bias temperature compensation module for silicon photomultiplier, avalanche photodiodes and similar photodetectors that possess a moderately linear temperature coefficient of gain and that may be compensated by varying an applied bias voltage. The module includes an electrical circuit and a method for determining component values to provide a constant voltage source to stabilize the gain of one or more photodetector devices. A temperature sensor in the module is held in close thermal contact with the photodetector and a filter capacitor is electrically close to the photodetector. The module is based on the concept of temperature sensitive voltage division which is applicable to situations in which large numbers of photodetectors must be gain-compensated for temperature variations over a wide range while maintaining excellent gain matching. The passive bias temperature compensation method enables multiple photodetectors to share a single constant voltage supply without loss of matching performance.

42 ENGINEERING↗

Active-cavity radiometer/pyroheliometer

Device, using specular black cavity heater, temperature sensors, and electronics and electrodeposited cavity/thermal impedance structures, can achieve + or - 0.1 percent long-term absolute uncertainty at solar constant level. Dual-cavity configuration helps decrease sensitivity for heat-sink temperature drift.

Willson, R. C.↗

Fiber-Optic Pressure Sensor With Dynamic Demodulation Developed

Researchers at the NASA Glenn Research Center developed in-house a method to detect pressure fluctuations using a fiber-optic sensor and dynamic signal processing. This work was in support of the Intelligent Systems Controls and Operations project under NASA's Information Technology Base Research Program. We constructed an optical pressure sensor by attaching a fiber-optic Bragg grating to a flexible membrane and then adhering the membrane to one end of a small cylinder. The other end of the cylinder was left open and exposed to pressure variations from a pulsed air jet. These pressure variations flexed the membrane, inducing a strain in the fiber-optic grating. This strain was read out optically with a dynamic spectrometer to record changes in the wavelength of light reflected from the grating. The dynamic spectrometer was built in-house to detect very small wavelength shifts induced by the pressure fluctuations. The spectrometer is an unbalanced interferometer specifically designed for maximum sensitivity to wavelength shifts. An optimum pathlength difference, which was determined empirically, resulted in a 14-percent sensitivity improvement over theoretically predicted path-length differences. This difference is suspected to be from uncertainty about the spectral power difference of the signal reflected from the Bragg grating. The figure shows the output of the dynamic spectrometer as the sensor was exposed to a nominally 2-kPa peak-to-peak square-wave pressure fluctuation. Good tracking, sensitivity, and signal-to-noise ratios are evident even though the sensor was constructed as a proof-of-concept and was not optimized in any way. Therefore the fiber-optic Bragg grating, which is normally considered a good candidate as a strain or temperature sensor, also has been shown to be a good candidate for a dynamic pressure sensor.

Lekki, John D.↗

High-Temperature Properties of Piezoelectric Langatate Single Crystals

Langasite type crystals belong to non-polar point group of 32 and do not show any phase transformations up to the melting temperature. Langatate (La3Ga(5.5)Ta(0.5)O14) demonstrates piezoelectric activity better than quartz and possesses attractive properties for high temperature sensors, resonators and filter applications. High-quality and colorless langatate crystals were grown by the Czochralski technique. The electromechanical and electrical properties of langatate crystals in different crystallographic directions were characterized at elevated temperature. The piezoelectric coefficient along x-axis was 7 pC/N as measured by a Berlincourt meter for a plate geometry with an aspect ratio of 10:1. The dielectric constant did not exhibit any significant temperature dependence (K33 approx. 21 at 30 C and K33 approx. 23 at 600 C). Loss tangent at 100 kHz remained <0.003 up to 300 C and <0.65 at 600 C. The dielectric properties along the y-axis were similar and its temperature dependence was analogous to the x-axis. Electromechanically, the inactive z-axis exhibited no resonance with K33 approx. 84 at room temperature, decreasing down to approx. 49 at 600 C. Resistivity of these crystals along x-axis decreased from approx. 6x10(exp 11) omega-cm at room temperature, to approx. 1.6x10(exp 6) omega-cm at 600 C.

Sehirlioglu, Alp↗

Soft x-ray detection for small satellites with a commercial CMOS sensor at room temperature

Recently CMOS (complementary metal-oxide-semiconductor) sensors have progressed to a point where they may offer improved performance in imaging x-ray detection compared to the CCDs often used in x-ray satellites. We demonstrate x-ray detection in the soft x-ray band (250-1700 eV) by a commercially available back-illuminated Sony IMX290LLR CMOS sensor using the Advanced Photon Source at the Argonne National Laboratory. Additionally, while operating the device at room temperature, we measure energy resolutions (FWHM) of 47 eV at 250 eV and and 77 eV 1700 eV which are comparable to the performance of the Chandra ACIS and the Suzaku XIS. Furthermore, we demonstrate that the IMX290LLR can withstand radiation up to 17.1 krad, making it suitable for use on spacecraft in low earth orbit.

47 OTHER INSTRUMENTATION↗

High Accuracy Temperature Measurements Using RTDs with Current Loop Conditioning

To measure temperatures with a greater degree of accuracy than is possible with thermocouples, RTDs (Resistive Temperature Detectors) are typically used. Calibration standards use specialized high precision RTD probes with accuracies approaching 0.001 F. These are extremely delicate devices, and far too costly to be used in test facility instrumentation. Less costly sensors which are designed for aeronautical wind tunnel testing are available and can be readily adapted to probes, rakes, and test rigs. With proper signal conditioning of the sensor, temperature accuracies of 0.1 F is obtainable. For reasons that will be explored in this paper, the Anderson current loop is the preferred method used for signal conditioning. This scheme has been used in NASA Lewis Research Center's 9 x 15 Low Speed Wind Tunnel, and is detailed.

Hill, Gerald M.↗

Thermal and radiation response of 4H–SiC Schottky diodes with direct-write electrical contacts

In this work, a high-sensitivity 4H–SiC temperature sensor and an alpha detector have been fabricated using additively printed metal contacts. The surface morphology and electrical conductivity of the printed electrodes were established prior to Schottky diode development. 4H–SiC Schottky diodes with direct-write printed silver contacts on the 5 μ m-thick epilayer on 4H–SiC were characterized electrically in terms of the forward and reverse current–voltage and high-frequency capacitance–voltage characteristics. Furthermore, the turn-on voltage of the Schottky diodes, as established from the forward current–voltage characteristics measured up to a temperature of 400 °C, showed a linear temperature dependence. Schottky diodes with direct-write printed Ag electrodes were able to measure alpha particles emitted from Americium-241. The high temperature and radiation response of the Schottky diodes show their suitability for multi-modal sensor fusion on the 4H–SiC platform for harsh environment applications.

42 ENGINEERING↗

High Temperature Irradiation Resistant Thermocouples

The High Temperature Irradiation Resistant Thermocouple (HTIR-TC) is the world’s leading temperature sensor for reactor fuel experiments and material test reactors (MTR), in general (e.g. Advanced Test Reactor, Massachusetts Institute of Technology Nuclear Reactor, etc.). Recently commercialized, the HTIR-TC provides real-time centerline and fuel cladding temperature measurements of reactor fuel experiments during irradiations. This provides direct information about fuel temperatures during Gen IV reactor, small modular reactor (SMR), and microreactor vetting processes. Further, the HTIR-TC recently won the 2019 R&D100 award under category: Analytical/Test.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Initial evaluation of a multimodal diamond sensor for simultaneous temperature and radiation measurements

Several experimental disciplines require simultaneous neutron flux and temperature monitoring. This paper provides the groundwork on a diamond sensor concept that could be used in harsh environments where the limits of current technologies are exceeded. Here, we present initial results on the functionality of a multimodal diamond sensor, which can simultaneously sense the presence of alpha particles at a few counts per second at temperatures up to 494 K. Such a sensor may also have applications where both charged particles or neutron detection and temperature measurement are simultaneously desired.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning snow depth predictions at sites in Alaska, Norway, Siberia, Colorado and New Mexico

Temporally continuous snow depth estimates are vital for understanding changing snow patterns in the Arctic and impacts on permafrost. We trained random forest machine learning models to predict snow depth from temperature data recorded at or just below the ground surface. Training data was collected at the Teller 27 Watershed and Kougarok 64 Hillslope during the 2021 - 2022 water year on the Seward Peninsula, Alaska using distributed temperature profiling (DTP) systems. We then applied this model to other sites where ground surface or shallow soil temperature data was available for at least one water year (see Related Datasets). Many of these temperature measurements were collocated with snow depth observations. Ground surface temperature (i.e. snow-ground interface temperature) is easy to measure using small, cheap and easy-to-deploy temperature sensors such as iButtons and TinyTags, and such measurements have previously been used to calculate a variety of snow metrics (e.g. snow onset date). However, this is the first study to estimate snow depth directly from ground surface temperature data. The present dataset contains one *.csv file which includes machine learning snow depth predictions at sites in Alaska, Norway, Siberia, Colorado, and New Mexico and one *.kml file including the locations of sites with snow depth predictions. No training data predictions are included in the *.csv file. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy’s Office of Biological and Environmental Research. The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy’s Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).

54 ENVIRONMENTAL SCIENCES↗

Project Plan: Salt in Situ Heater Test

This project plan gives a high-level description of the US Department of Energy Office of Nuclear Energy (DOE-NE) Spent Fuel and Waste Disposition (SFWD) campaign in situ borehole heater test project planned for the Waste Isolation Pilot Plant (WIPP) site, titled the Brine Availability Test in Salt (BATS). BATS is the first stage in a planned sequence of tests to bolster the technical basis for disposal of heat generating waste in salt. This plan provides an overview of the schedule and responsibilities of the parties involved. This project is a collaborative effort by Sandia, Los Alamos, and Lawrence Berkeley National Laboratories to execute a series of small-diameter borehole heater tests in salt for the DOE-NE SFWD campaign. Design of a heater test in salt at WIPP has evolved over several years. The experiment has begun in January 2020 and the first phase will continue for several months with the possibility for follow on testing. BATS comprises a suite of modular tests, which consist of a group of adjacent horizontal boreholes in the wall of drifts at WIPP. Each test is centered around a packer-isolated heated borehole (12.2 cm [4.81 diameter) containing equipment for water-vapor collection and borehole closure monitoring, surrounded by smaller-diameter (up to 5.3 cm [2.11 diameter) satellite observation boreholes. Observation boreholes contain grouted-in temperature sensors, electrical resistivity tomography (ERT) sensors, and fiber optics; packer-isolated tracer release and sampling intervals; and acoustic emission (AE) piezoelectric sensors. A larger-diameter (12.2 cm [4.81) satellite borehole includes sorel and salt cement plugs, as part of an engineered barrier sealing test. The first two tests, to be implemented in parallel, are heated (target borehole wall temperature of 120 °C) and unheated, with similar arrays of observation borehole monitoring changes. Follow-on tests will be designed using information gathered from the first two tests, and may be conducted at other borehole wall temperatures, use multiple observation boreholes, and may include different measurement types and test designs. This 2020 update of the original 2018 project plan satisfies DOE-NE Spent Fuel and Waste Science and Technology (SFWST) milestone M3SF-205N010303034, as part of the SNL "Salt Disposal R&D" work package.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Loop Heat Pipe Transient Behavior Using Heat Source Temperature for Set Point Control with Thermoelectric Converter on Reservoir

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly done by cold biasing the reservoir and using electrical heaters to provide the required control power. With this method, the loop operating temperature can be controlled within 0.5K or better. However, because the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if the LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP was carried out to investigate the effects on the LHP operation when the control temperature sensor was placed on the heat source instead of the reservoir. In these tests, the LHP reservoir was cold-biased and was heated by a control heater. Test results show that it was feasible to use the heat source temperature for feedback control of the LHP operation. In particular, when a thermoelectric converter was used as the reservoir control heater, the heat source temperature could be maintained within a tight range using a proportional-integral-derivative or on/off control algorithm. Moreover, because the TEC could provide both heating and cooling to the reservoir, temperature oscillations during fast transients such as loop startup could be eliminated or substantially reduced when compared to using an electrical heater as the control heater.

Ku, Jentung↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

Ku, Jentung↗

Comparison of Satellite, Thermochron and Air Temperatures at Summit, Greenland, During the Winter of 2008/09

Current trends show rise in Arctic surface and air temperatures, including over the Greenland ice sheet where rising temperatures will contribute to increased sea-level rise through increased melt. We aim to establish the uncertainties in using satellite-derived surface temperature for measuring Arctic surface temperature, as satellite data are increasingly being used to assess temperature trends. To accomplish this, satellite-derived surface temperature, or land-surface temperature (LST), must be validated and limitations of the satellite data must he assessed quantitatively. During the 2008/09 boreal winter at Summit, Greenland, we employed data from standard US National Oceanic and Atmospheric Administration (NOAA) air-temperature instruments, button-sized temperature sensors called thermochrons and the Moderate Resolution Imaging Spectroradiometer (MODIS) satellite instrument to (1) assess the accuracy and utility of thermochrons in an ice-sheet environment and (2) compare MODIS-derived LSTs with thermochron-derived surface and air temperatures. The thermochron-derived air temperatures were very accurate, within 0.1+/-0.3 C of the NOAA-derived air temperature, but thermochron-derived surface temperatures were approx. 3 C higher than MODIS-derived LSTs. Though the surface temperature is largely determined by air temperature, these variables can differ significantly. Furthermore, we show that the winter-time mean air temperature, adjusted to surface temperature was approx. 11 C higher than the winter-time mean MODIS-derived LST. This marked difference occurs largely because of satellite-derived LSTs cannot be measured through cloud cover, so caution must be exercised in using time series of satellite LST data to study seasonal temperature trends.

Koenig, Lora S.↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗

Porous media matric potential and water content measurements during parabolic flight

Control of water and air in the root zone of plants remains a challenge in the microgravity environment of space. Due to limited flight opportunities, research aimed at resolving microgravity porous media fluid dynamics must often be conducted on Earth. The NASA KC-135 reduced gravity flight program offers an opportunity for Earth-based researchers to study physical processes in a variable gravity environment. The objectives of this study were to obtain measurements of water content and matric potential during the parabolic profile flown by the KC-135 aircraft. The flight profile provided 20-25 s of microgravity at the top of the parabola, while pulling 1.8 g at the bottom. The soil moisture sensors (Temperature and Moisture Acquisition System: Orbital Technologies, Madison, WI) used a heat-pulse method to indirectly estimate water content from heat dissipation. Tensiometers were constructed using a stainless steel porous cup with a pressure transducer and were used to measure the matric potential of the medium. The two types of sensors were placed at different depths in a substrate compartment filled with 1-2 mm Turface (calcined clay). The ability of the heat-pulse sensors to monitor overall changes in water content in the substrate compartment decreased with water content. Differences in measured water content data recorded at 0, 1, and 1.8 g were not significant. Tensiometer readings tracked pressure differences due to the hydrostatic force changes with variable gravity. The readings may have been affected by changes in cabin air pressure that occurred during each parabola. Tensiometer porous membrane conductivity (function of pore size) and fluid volume both influence response time. Porous media sample height and water content influence time-to-equilibrium, where shorter samples and higher water content achieve faster equilibrium. Further testing is needed to develop these sensors for space flight applications.

Parabolic Flight↗