Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “target setting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

DWPF Simulant CPC Studies For SB8

Prior to processing a Sludge Batch (SB) in the Defense Waste Processing Facility (DWPF), flowsheet studies using simulants are performed. Typically, the flowsheet studies are conducted based on projected composition(s). The results from the flowsheet testing are used to 1) guide decisions during sludge batch preparation, 2) serve as a preliminary evaluation of potential processing issues, and 3) provide a basis to support the Shielded Cells qualification runs performed at the Savannah River National Laboratory (SRNL). SB8 was initially projected to be a combination of the Tank 40 heel (Sludge Batch 7b), Tank 13, Tank 12, and the Tank 51 heel. In order to accelerate preparation of SB8, the decision was made to delay the oxalate-rich material from Tank 12 to a future sludge batch. SB8 simulant studies without Tank 12 were reported in a separate report.1 The data presented in this report will be useful when processing future sludge batches containing Tank 12. The wash endpoint target for SB8 was set at a significantly higher sodium concentration to allow acceptable glass compositions at the targeted waste loading. Four non-coupled tests were conducted using simulant representing Tank 40 at 110-146% of the Koopman Minimum Acid requirement. Hydrogen was generated during high acid stoichiometry (146% acid) SRAT testing up to 31% of the DWPF hydrogen limit. SME hydrogen generation reached 48% of of the DWPF limit for the high acid run. Two non-coupled tests were conducted using simulant representing Tank 51 at 110-146% of the Koopman Minimum Acid requirement. Hydrogen was generated during high acid stoichiometry SRAT testing up to 16% of the DWPF limit. SME hydrogen generation reached 49% of the DWPF limit for hydrogen in the SME for the high acid run. Simulant processing was successful using previously established antifoam addition strategy. Foaming during formic acid addition was not observed in any of the runs. Nitrite was destroyed in all runs and no N2O was detected during SME processing. Mercury behavior was consistent with that seen in previous SRAT runs. Mercury was stripped below the DWPF limit on 0.8 wt% for all runs. Rheology yield stress fell within or below the design basis of 1-5 Pa. The low acid Tank 40 run (106% acid stoichiometry) had the highest yield stress at 3.78 Pa.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Exploratory Experiments to Probe the Effect of Bulk Density and Porosity on The Morphology and Ejecta Kinematics of Impact Craters

The morphometry of relatively small impact craters are influenced by the physical properties of the target. To investigate the control of bulk density and porosity on the crater-formation processing the gravity regime, we conducted a series of impact experiments, varying each these target parameters while holding the other constant. Three different sands were used to construct cohesionless targets: quartz (0.4-0.8 mm), garnet (0.425-1.0 mm), and alumina (0.297-0.71mm), representing a range of intrinsic grain densities from 2.65 to 4.02 g cm-3. High-porosity targets were constructed by carefully pouring the sand into the center of a cylindrical PVC target bucket (inner diameter 26.2 cm, height 12 cm) and allowing it to fill the bucket at the angle of repose before being leveled flat at the top of the bucket. Low-porosity targets were obtained by pluviation of the granular material through a 1 mm sieve that was set directly above the target bucket. With the disparate intrinsic densities of the sand in combination with the variations of the packing technique, we attained differences in the bulk-target density of up to 32%while keeping porosity constant. The impact experiments were conducted with the vertical gun in the Experimental Impact Laboratory at NASA Johnson Space Center; using 3/16” (4.76 mm) diameter aluminum projectiles launched at1.55 ± 0.03 km s-1. The ejecta were observed using the laser-based Ejection Velocity Measurement System, providing data on launch positions and velocities of ejected particles. Submillimeter topographic data of the resulting craters were collected after each experiment with a NextEngine 3D scanner. Regardless of target material or density, all craters exhibited a simple bowl shape, but a trend of increasing depth-diameter ratio with increasing target porosity is observed across the entire experimental suite. Despite these morphometric differences, ejecta launch angles and speeds remain remarkably similar amongst all of the target configurations.

impact cratering↗

Video guidance sensor

A Martin-Marietta study comparing the application of laser, video, or RF sensors was conducted in 1982. The study concluded that video was the most attractive sensor (the video also could be used for operator monitoring). The Retro-Reflector field Tracker from the Solar Array Flight Experiment was chosen as a 'first generation' sensor and integrated with guidance algorithms for evaluation on the air-bearing vehicle. Results indicated that this sensor was not applicable for the noise environment posed by the multi-layer insulation used on most spacecraft. A 'second generation' sensor was developed to be used with a modified RMS target. This sensor utilized two sets of laser diodes to acquire three optically filtered targets. The targets were illuminated first with a 780 nanometer diode, followed by illumination with a 830 nm diode. The second digitized picture was subtracted from the first to get a low-noise image. The centroids of the retroreflectors were used then to uniquely derive target attitude and range. The sensor presently operates to 80 feet and within +/- 40 degrees in pitch and yaw. Sensor operability is a concern if the sun is within a +/- 40 degree cone angle to the target. The present sensor performance characteristics are less than 1 percent range error and less than 1 degree angle error. Future sensor development is anticipated to extend the operating range to 150 feet and reduce the cone angle of sensor inoperability to within +/- 10 degrees of direct sunlight. Performance improvements also are anticipated. TRW currently is developing a system that utilizes dual cameras with simultaneous diode illumination. Although further development is being pursued, the basic system has proven sound, and the sensor is essentially ready for application.

Howard, Richard↗

Predicting Drug Effects from High-dimensional Asymmetric Drug Data Sets using Graph Neural Networks: A Comprehensive Analysis of Multi-target Drug Effect Prediction

Graph neural networks (GNNs) have emerged as one of the most effective Machine learning (ML) techniques for drug effect prediction from drug molecular graphs. Despite having immense potential, GNN models lack performance when using data sets that contain high dimensional asymmetrically co-occurrent drug effects as targets with complex correlations between them. Training individual learning models for each drug effect and incorporating every prediction result for a wide spectrum of drug effects is beyond practicality. Such an implication provides a testbed to address this challenge as multi-target prediction problems, aiming to predict all drug effects at a time. We develop standard and hybrid graph neural networks (GNNs)to perform two separate tasks that are multi-regression for continuous values and multi-label classification for categorical values contained in our data sets. Since this step makes the target data even more sparse and introduces asymmetric label co-occurrence, the learning of multi-label classification models becomes difficult and heavily impacts the GNN's performance. To address these challenges, we propose a new data oversampling technique to improve multi-label classification performances on all the given imbalanced molecular graph data sets. Using the technique, we improve the data imbalance ratio of the drug effects better than before while protecting the data set's integrity. Finally, we evaluate multi-label classification performance using the best-performant hybrid GNN model on all the oversampled data sets obtained from the proposed oversampling technique. These results outperform those of other ML models including GNN models when they are trained on the original data sets or oversampled data sets using MLSMOTE (a well-known oversampling technique) in all evaluation metrics precision, recall, and F1 score by a significant margin.

Bose, Avishek [ORNL]↗

A New Treatment Paradigm: Neoadjuvant Radiosurgery Before Surgical Resection of Brain Metastases With Analysis of Local Tumor Recurrence

Purpose: Resected brain metastases (BM) require radiation therapy to reduce local recurrence. Whole brain radiation therapy (WBRT) reduces recurrence, but with potential toxicity. Postoperative stereotactic radiosurgery (SRS) is a strategy without prospective data and problematic target delineation. SRS delivered in the preoperative setting (neoadjuvant, or NaSRS) allows clear target definition and reduction of intraoperative dissemination of tumor cells. Methods and Materials: Our treatment of resectable BM with NaSRS was begun in 2005. Subsequently, a prospective trial of NaSRS was undertaken. A total of 47 consecutively treated patients (23 database and 24 prospective trial) with a total of 51 lesions were reviewed. No statistical difference was observed between the 2 cohorts, and they were combined for analysis. The median follow-up time was 12 months (range, 1-58 months), and the median age was 57. A median of 1 day elapsed between NaSRS and resection. The median diameter of lesions was 3.04 cm (range, 1.34-5.21 cm), and the median volume was 8.49 cc (range, 0.89-46.7 cc). A dose reduction strategy was used, with a median dose of 14 Gy (range, 11.6-18 Gy) prescribed to 80% isodose. Results: Kaplan-Meier overall survival was 77.8% and 60.0% at 6 and 12 months. Kaplan-Meier local control was 97.8%, 85.6%, and 71.8% at 6, 12, and 24 months, respectively. Five of 8 failures were proved pathologically without radiation necrosis. There were no perioperative adverse events. Ultimately, 14.8% of the patients were treated with WBRT. Local failure was more likely with lesions >10 cc (P=.01), >3.4 cm (P=.014), with a trend in surface lesions (P=.066) and eloquent areas (P=.052). Six of the 8 failures had an obvious dural attachment or proximity to draining veins. Conclusions: NaSRS can be performed safely and effectively with excellent results without documented radiation necrosis. Local control was excellent even in the setting of large (>3 cm) lesions. The strong majority of patients were able to avoid WBRT. NaSRS merits consideration in a multi-institution trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MassIVE MSV000087434 - Raw data files for NetID manuscript

This dataset is associated with this manuscript: Metabolite discovery through global annotation of untargeted metabolomics data. Li Chen, Wenyun Lu, Lin Wang, Xi Xing, Xin Teng, Xianfeng Zeng, Antonio D Muscarella, Yihui Shen, Alexis Cowan, Melanie R McReynolds, Brandon Kennedy, Ashley M Lato, Shawn R Campagna, Mona Singh, Joshua Rabinowitz. The dataset has six main folders: (1) Yeast-MS1 (2) Yeast-labeling (3) Liver-MS1 (4) Liver-targeted-MS2 (separate folders for mzxml files and matched csv files used as the inclusion list to set up PRM targeted-MS2 runs) (5) Mouse-labeling (6) Glucosyl_taurine-liver-vs-synthesis. Please refer to README-raw-data-NetID-20210512.doc for more details. [doi:10.25345/C5WV53] [dataset license: CC0 1.0 Universal (CC0 1.0)]

full scan MS1↗

Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

99 GENERAL AND MISCELLANEOUS↗

Developing Performance Cost Index Targets for ASHRAE Standard 90.1 Appendix G – Performance Rating Method - Rev.1

Appendix G, the Performance Rating Method in ASHRAE Standard 90.1 has been updated to make two significant changes for the 2016 edition, to be published in October of 2016. First, it allows Appendix G to be used as a third path for compliance with the standard in addition to rating beyond code building performance. This prevents modelers from having to develop separate building models for code compliance and beyond code programs. Using this new version of Appendix G to show compliance with the 2016 edition of the standard, the proposed building design needs to have a performance cost index (PCI) less than targets shown in a new table based on building type and climate zone. The second change is that the baseline design is now fixed at a stable level of performance set approximately equal to the 2004 code. Rather than changing the stringency of the baseline with each subsequent edition of the standard, compliance with new editions will simply require a reduced PCI (a PCI of zero is a net-zero building). Using this approach, buildings of any era can be rated using the same method. The intent is that any building energy code or beyond code program can use this methodology and merely set the appropriate PCI target for their needs. This report discusses the process used to set performance criteria for compliance with ASHRAE Standard 90.1-2016 and suggests a method for demonstrating compliance with other codes and beyond code programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Recent Status of SIM Lite Astrometric Observatory Mission: Flight Engineering Risk Reduction Activities

The SIM Lite Astrometric Observatory is a mission concept for a space-borne instrument to perform micro-arc-second narrow-angle astrometry to search 60 to 100 nearby stars for Earth-like planets, and to perform global astrometry for a broad astrophysics program. The instrument consists of two Michelson stellar interferometers and a telescope. The first interferometer chops between the target star and a set of reference stars. The second interferometer monitors the attitude of the instrument in the direction of the target star. The telescope monitors the attitude of the instrument in the other two directions. The main enabling technology development for the mission was completed during phases A & B. The project is currently implementing the developed technology onto flight-ready engineering models. These key engineering tasks will significantly reduce the implementation risks during the flight phases C & D of the mission. The main optical interferometer components, including the astrometric beam combiner, the fine steering optical mechanism, the path-length-control and modulation optical mechanisms, focal-plane camera electronics and cooling heat pipe, are currently under development. Main assemblies are built to meet flight requirements and will be subjected to flight qualification level environmental testing (random vibration and thermal cycling) and performance testing. This paper summarizes recent progress in engineering risk reduction activities.

astrometry↗

Data Remapping Between One Dimensional Meshes [Slides]

Remapping involves two meshes (source and target), where a discrete set of field values (data) is available on only one of the meshes (source mesh). Since the source and target mesh can be different, we need to find an approximation of the field on the target mesh using the data available on the source mesh. We will consider two algorithms for this problem: point-wise remap and conservative remap.

79 ASTRONOMY AND ASTROPHYSICS↗

Robust Control Design via Linear Programming

This paper deals with the problem of synthesizing or designing a feedback controller of fixed dynamic order. The closed loop specifications considered here are given in terms of a target performance vector representing a desired set of closed loop transfer functions connecting various signals. In general these point targets are unattainable with a fixed order controller. By enlarging the target from a fixed point set to an interval set the solvability conditions with a fixed order controller are relaxed and a solution is more easily enabled. Results from the parametric robust control literature can be used to design the interval target family so that the performance deterioration is acceptable, even when plant uncertainty is present. It is shown that it is possible to devise a computationally simple linear programming approach that attempts to meet the desired closed loop specifications.

Keel, L. H.↗

MO-F-CAMPUS-T-05: Correct Or Not to Correct for Rotational Patient Set-Up Errors in Stereotactic Radiosurgery

Purpose: To quantify the effect of patient rotation in stereotactic radiation therapy and establish a threshold where rotational patient set-up errors have a significant impact on target coverage. Methods: To simulate rotational patient set-up errors, a Matlab code was created to rotate the patient dose distribution around the treatment isocentre, located centrally in the lesion, while keeping the structure contours in the original locations on the CT and MRI. Rotations of 1°, 3°, and 5° for each of the pitch, roll, and yaw, as well as simultaneous rotations of 1°, 3°, and 5° around all three axes were applied to two types of brain lesions: brain metastasis and acoustic neuroma. In order to analyze multiple tumour shapes, these plans included small spherical (metastasis), elliptical (acoustic neuroma), and large irregular (metastasis) tumour structures. Dose-volume histograms and planning target volumes were compared between the planned patient positions and those with simulated rotational set-up errors. The RTOG conformity index for patient rotation was also investigated. Results: Examining the tumour volumes that received 80% of the prescription dose in the planned and rotated patient positions showed decreases in prescription dose coverage of up to 2.3%. Conformity indices for treatments with simulated rotational errors showed decreases of up to 3% compared to the original plan. For irregular lesions, degradation of 1% of the target coverage can be seen for rotations as low as 3°. Conclusions: This data shows that for elliptical or spherical targets, rotational patient set-up errors less than 3° around any or all axes do not have a significant impact on the dose delivered to the target volume or the conformity index of the plan. However the same rotational errors would have an impact on plans for irregular tumours.

60 APPLIED LIFE SCIENCES↗

CryoTEN: efficiently enhancing cryo-EM density maps using transformers

Abstract Motivation Cryogenic electron microscopy (cryo-EM) is a core experimental technique used to determine the structure of macromolecules such as proteins. However, the effectiveness of cryo-EM is often hindered by the noise and missing density values in cryo-EM density maps caused by experimental conditions such as low contrast and conformational heterogeneity. Although various global and local map-sharpening techniques are widely employed to improve cryo-EM density maps, it is still challenging to efficiently improve their quality for building better protein structures from them. Results In this study, we introduce CryoTEN—a 3D UNETR++ style transformer to improve cryo-EM maps effectively. CryoTEN is trained using a diverse set of 1295 cryo-EM maps as inputs and their corresponding simulated maps generated from known protein structures as targets. An independent test set containing 150 maps is used to evaluate CryoTEN, and the results demonstrate that it can robustly enhance the quality of cryo-EM density maps. In addition, automatic de novo protein structure modeling shows that protein structures built from the density maps processed by CryoTEN have substantially better quality than those built from the original maps. Compared to the existing state-of-the-art deep learning methods for enhancing cryo-EM density maps, CryoTEN ranks second in improving the quality of density maps, while running >10 times faster and requiring much less GPU memory than them. Availability and implementation The source code and data are freely available at https://github.com/jianlin-cheng/cryoten.

Biochemistry & Molecular Biology↗

Umpire

The Umpire library consists of a collection of software components that provide memory and resource management capabilities that can be used by diverse high performance computing (HPC) applications. The current set of capabilities that Umpire provides Includes: • Flexible allocators to provision memory In the range of available memory resources on a target system. • An extensible allocation strategy model, allowing custom algorithms to be used to allocate memory resources in a scalable and high­performance fashion. • Memory-location aware operations that can be used to migrate and modify memory using specialized functions dependent on source and target data locations • A set of Introspection capabilities to allow the user to query the state of the different allocators and memory allocations.

ECP↗

Laser Range and Bearing Finder with No Moving Parts

A proposed laser-based instrument would quickly measure the approximate distance and approximate direction to the closest target within its field of view. The instrument would not contain any moving parts and its mode of operation would not entail scanning over of its field of view. Typically, the instrument would be used to locate a target at a distance on the order of meters to kilometers. The instrument would be best suited for use in an uncluttered setting in which the target is the only or, at worst, the closest object in the vicinity; for example, it could be used aboard an aircraft to detect and track another aircraft flying nearby. The proposed instrument would include a conventional time-of-flight or echo-phase-shift laser range finder, but unlike most other range finders, this one would not generate a narrow cylindrical laser beam; instead, it would generate a conical laser beam spanning the field of view. The instrument would also include a quadrant detector, optics to focus the light returning from the target onto the quadrant detector, and circuitry to synchronize the acquisition of the quadrant-detector output with the arrival of laser light returning from the nearest target. A quadrant detector constantly gathers information from the entire field of view, without scanning; its output is a direct measure of the position of the target-return light spot on the focal plane and is thus a measure of the direction to the target. The instrument should be able to operate at a repetition rate high enough to enable it to track a rapidly moving target. Of course, a target that is not sufficiently reflective could not be located by this instrument. Preferably, retroreflectors should be attached to the target to make it sufficiently reflective.

Bryan, Thomas C.↗

Recent Results of the Guide-2 Telescope Testbed for the SIM-Lite Mission

The Space Interferometry Mission Planet QuestLite (SIM-Lite) is a new mission concept to perform microarcsecond narrow-angle astrometry to search approximately 50 nearby stars for Earth-like planets, and also to perform a global astrometry. The SIM-Lite consists of two Michelson interferometers and one telescope. The main six-meter baseline science interferometer observes a target star and a set of reference stars. The four-meter baseline interferometer (Guide-1) monitors the attitude of the instrument in the direction of a target star. A new Guide-2telescope (G2T) tracks a bright star to monitor the attitude of the instrument in the other two orthogonal directions. In the current mission concept, the G2T consists of a 30 cm siderostat and a 30 cm confocal telescope, similar to other four telescopes used in the science and Guide-1interferometers. A testbed has been built to demonstrate the G2T feasibility for SIM-Lite mission. Recent results show that field-independent, star-tracking capability of the system is less than 30 (mu)as after the SIM narrow angle analysis.

Guide-2 Telescope↗

Applying Machine‐Learning Methods to Laser Acceleration of Protons: Lessons Learned From Synthetic Data

ABSTRACT In this study, we consider three different machine‐learning methods—a three‐hidden‐layer neural network, support vector regression, and Gaussian process regression—and compare how well they can learn from a synthetic data set for proton acceleration in the Target Normal Sheath Acceleration regime. The synthetic data set was generated from a previously published theoretical model by Fuchs et al. 2005 that we modified. Once trained, these machine‐learning methods can assist with efforts to maximize the peak proton energy, or with the more general problem of configuring the laser system to produce a proton energy spectrum with desired characteristics. In our study, we focus on both the accuracy of the machine‐learning methods and the performance on one GPU including memory consumption. Although it is arguably the least sophisticated machine‐learning model we considered, support vector regression performed very well in our tests.

Desai, Ronak↗

Alternating magnetic fields and antibiotics eradicate biofilm on metal in a synergistic fashion

Abstract Hundreds of thousands of human implant procedures require surgical revision each year due to infection. Infections are difficult to treat with conventional antibiotics due to the formation of biofilm on the implant surface. We have developed a noninvasive method to eliminate biofilm on metal implants using heat generated by intermittent alternating magnetic fields (iAMF). Here, we demonstrate that heat and antibiotics are synergistic in biofilm elimination. For Pseudomonas aeruginosa biofilm, bacterial burden was reduced >3 log with iAMF and ciprofloxacin after 24 h compared with either treatment alone ( p < 0.0001). This effect was not limited by pathogen or antibiotic as similar biofilm reductions were seen with iAMF and either linezolid or ceftriaxone in Staphylococcus aureus . iAMF and antibiotic efficacy was seen across various iAMF settings, including different iAMF target temperatures, dose durations, and dosing intervals. Initial mechanistic studies revealed membrane disruption as one factor important for AMF enhanced antibacterial activity in the biofilm setting. This study demonstrates the potential of utilizing a noninvasive approach to reduce biofilm off of metallic implants.

59 BASIC BIOLOGICAL SCIENCES↗