Software-Defined Ultrasonic Communication System With OFDM for Secure Video Monitoring
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
This paper describes one such reference process that can be deployed to provide continuous automated conditioned-based maintenance management for buildings that have BIM, a building automation system (BAS) and a computerized maintenance management software (CMMS) systems. The process can be deployed using an open source transactional network platform, VOLTTRON™, designed for distributed sensing and controls and supports both energy efficiency and grid services.
No matter the source, offshore wind energy plant cost estimates are significantly higher than for land-based projects. For instance, a National Renewable Energy Laboratory (NREL) review on the 2010 cost of wind energy found baseline cost estimates for onshore wind energy systems to be 71 dollars per megawatt-hour ($/MWh), versus 225 $/MWh for offshore systems. There are many ways that innovation can be used to reduce the high costs of offshore wind energy. However, the use of such innovation impacts the cost of energy because of the highly coupled nature of the system. For example, the deployment of multimegawatt turbines can reduce the number of turbines, thereby reducing the operation and maintenance (O&M) costs associated with vessel acquisition and use. On the other hand, larger turbines may require more specialized vessels and infrastructure to perform the same operations, which could result in higher costs. To better understand the full impact of a design decision on offshore wind energy system performance and cost, a system analysis approach is needed. In 2011-2012, NREL began development of a wind energy systems engineering software tool to support offshore wind energy system analysis. The tool combines engineering and cost models to represent an entire offshore wind energy plant and to perform system cost sensitivity analysis and optimization. Initial results were collected by applying the tool to conduct a sensitivity analysis on a baseline offshore wind energy system using 5-MW and 6-MW NREL reference turbines. Results included information on rotor diameter, hub height, power rating, and maximum allowable tip speeds.
During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.
COMMON is a tool for collecting, storing, displaying, and providing analysis on critical information about radiation detection system communications systems and software. The COMMON tool runs directly on a communication system to provide valuable insight into the performance of the monitored hardware and software and to provide data and reports for later SME use.
Adaptive optics is used to correct the wavefront of a beam of light. It originated in the field of astronomy to correct for atmospheric turbulence. This project was to construct an adaptive optics (AO) system kit from Thorlabs. An AO system consists of three parts: a deformable mirror (DM), a wavefront sensor (WFS), and control software. This system is to be used for future teaching purposes to help others learn about adaptive optics. The AO system came with instruction manuals, which were followed to build and calibrate the system. The instructions included building and aligning the system, how to install and use the software, and how to calibrate deformable mirror. A calibrated system for this project means having the deformable mirror imaged onto the wavefront sensor, with the center of the mirror on the center of the WFS. Also, a flat wavefront, which is achieved by eliminating the tip/tilt of the mirror. Eliminating the tip/tilt reduces the RMS amplitude to a value below 0.200 microns. This causes the wavefront to fold in on itself. We set up a focal plane detector behind beam splitter as a demonstration of what would be seen if this were used with a telescope. The image that should be seen on the focal plane detector is the beam with a diffraction pattern called and Airy Function. The AO system is now ready to be used to teach others about adaptive optics.
Continuous monitoring and archiving of background radiation levels in and around the nuclear installation is essential and the data would be of immense use during analysis of any untoward incidents. A portable Geiger Muller detector based autonomous gamma dose logger (AGDL) for environmental monitoring is indigenously designed and developed. The system operations are controlled by microcontroller (AT89S52) and the main features of the system are software data acquisition, real time LCD display of radiation level, data archiving at removable compact flash card. The complete system operates on 12 V battery backed up by solar panel and hence the system is totally portable and ideal for field use. The system has been calibrated with Co-60 source (8.1 MBq) at various source-detector distances. The system is field tested and performance evaluation is carried out. This paper covers the design considerations of the hardware, software architecture of the system along with details of the front-end operation of the autonomous gamma dose logger and the data file formats. The data gathered during field testing and inter comparison with GammaTRACER are also presented in the paper. AGDL has shown excellent correlation with energy fluence monitor tuned to identify {sup 41}Ar, proving its utility for real-time plume tracking and source term estimation.
The Spallation Neutron Source at Oak Ridge National Laboratory has been operating since 2006. An upgrade to double the machine power from 1.4 MW to 2.8 MW is currently underway and a project to add a second target station is in the preliminary design phase. While each project will add the controls needed for their specific scope, the existing control system hardware, software, and infrastructure require upgrades to maintain high availability and ensure the system will meet facility requirements into the future. While some systems have received new hardware due to obsolescence, much of the system is original apart from some maintenance and technology refresh. Software will also become obsolete and must be upgraded for sustainability. Further, requirements for system capacity can be expected to increase as more subsystems upgrade to smarter devices capable of higher data rates. This paper covers planned improvements to the integrated control system with a focus on reliability, sustainability, and future capability.
Not Available
C3PU sets up a model predictive control formulation for the optimal charging control of battery packs and can be deployed for real-time operation on an embedded microprocessor. C3PU uses electrochemical and thermal models of battery packs to predict the charging trajectories of the battery pack over a time horizon under different operating conditions. It then selects the optimal charging trajectory such that a pre-defined objective is minimized, which in the present state of the code is to minimize the charging duration of the battery pack. The optimal charging trajectory is obtained by solving an underlying mathematical problem. However, C3PU is flexible to incorporate other charging objectives. The underlying battery models can be swapped as well, as long as they follow certain mathematical properties. Mathematically, optimal control problems (in this case, optimally controlling the charging current of the battery pack) are computationally expensive. C3PU implements advanced numerical techniques, namely pseudo-spectral optimization, to reduce the computational burden of the underlying problem to solve. This allows for the problem to be solved in real-time in an embedded system. Once the optimal charging trajectory is computed over a time horizon, C3PU can package such data and send it out via appropriate communication protocols.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Abstract not provided.
The Department of Energy and the National Cancer Institute have developed new software for conducting multi-scale simulations of complex systems. This software, called the Multiscale Machine-Learned Modeling Infrastructure (MuMMI), couples simulations on three spatial scales to study slow, large-scale reorganizations of biomolecular systems with the speed of continuum and coarse-grained models while revealing selected interactions at full atomic precision. In these simulations, coarse-to-fine model conversions are used to spawn relevant fine-scale simulations along chosen order parameters, and fine-to-coarse feedback is used to iteratively improve the accuracy and multi-scale consistency of coarse-scale and continuum simulations. The complete MuMMI framework will be reviewed and released as open-source software by Lawrence Livermore National Laboratory. This review covers a subset of the MuMMI components that were developed exclusively at the Los Alamos National Laboratory.
Application Binary Interface (ABI) compatibility is essential for system or software updates to ensure that libraries continue to function. Tools that can assess a binary or library ABI can thus be used to make predictions about compatibility, and predict downstream bugs by informing developers and users about issues. In this work, we are interested in describing a set of well-known tools for assessing ABI, and testing them in a controlled set experiments to assess tool agreement. We run 7660 smaller experiments across tools (N=30,640 total results) to evaluate not only predictions, but also each tool’s ability to provide detail about underlying issues. In this paper, along with highlighting the problem of assessing ABI compatibility and critiquing the pros and cons of currently available tools, we provide guidance to developers interested to test ABI based on our empirical results and suggestions for future work.
Purpose: The purpose of this study was to evaluate and compare the accuracy of dose calculation algorithms in the second check software programs Radcalc, Diamond, IMSure, and MUcheck, against the Pinnacle3 treatment planning system (TPS). Methods: Baseline accuracy of the second check software was established by comparison against Pinnacle TPS data using open square fields of 5, 10, 20, 30 and 40cm in a SAD setup. 18 previously treated patients’ files were exported from the Pinnacle3 TPS to each of the four second check softwares, consisting of 146 step and shoot intensity modulated radiotherapy (IMRT) beams and 60 Smart Arcs. Monitor unit (MU) calculated in each of the software were compared with the TPS and the values were represented as a percent difference. Open fields were calculated as a baseline for each software’s accuracy using 5×5, 10×10, 20×20, 30×30, and 40×40 fields. Box plots, Pearson correlation, and Bland-Altman analysis were used for comparison of the results. Results: The baseline accuracy was established to within 0.6%, −1.4%, −0.2%, and −1.0% for Diamond, IMSure,MUcheck, and Radcalc, respectively. In the clinical data, the dose difference represented as mean ± 1 standard deviation were 0.7%±0.1%, −0.3%±0.1%, −1.5%±0.1%, and 0.4%±0.0% for Diamond, IMSure, MUcheck, and Radcalc, respectively Conclusion: The implementation of Clarkson algorithm for the dose calculation between each of the software in question can vary considerably. The currently used second check software, Radcalc has shown the best agreement on average, variance, and smallest percent range from Pinnacle3 TPS values. The closest in average percent difference from the TPS data was the IMSure software, but has significantly larger variance and percent range. The mean percent differences in Diamond and MUcheck were significantly larger than Radcalc and IMSure.