Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “suspensions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A solid-state controllable power supply for a magnetic suspension wind tunnel

The NASA Langley 6-inch Magnetic Suspension and Balance System (6-in. MSBS) requires an independently controlled bidirectional dc power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance-coupled thyratron-controlled rectifiers as well as ac to dc motor-generator converters, is obsolete, inefficient, and unreliable. A replacement six-phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full-load efficiency is 80 percent compared with 25 percent for the resistance-coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20-kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

Daniels, Taumi S.↗

Description of the Large-Gap Magnetic Suspension System (LGMSS) ground based experiment

An overview of the Large Gap Magnetic Suspension System (LGMSS) ground-based experiment is provided. A description of the experiment, as originally defined, and the experiment objectives and potential applications of the technology resulting from the experiment are presented. Also, the results of two studies which were conducted to investigate the feasibility of implementing the experiment are presented and discussed. Finally, a description of the configuration which was selected for the experiment is described, and a summary of the paper is presented.

Groom, Nelson J.↗

Large gap magnetic suspension system

The design of a large gap magnetic suspension system is discussed. Some of the topics covered include: the system configuration, permanent magnet material, levitation magnet system, superconducting magnets, resistive magnets, superconducting levitation coils, resistive levitation coils, levitation magnet system, and the nitrogen cooled magnet system.

Abdelsalam, Moustafa K.↗

Single element magnetic suspension actuator

The invention, a single element magnetic suspension actuator with bidirectional force capability along a single axis, includes an electromagnet and a nonmagnetic suspended element. A permanent magnet mounted on the suspended element interacts with a magnetic field established by the electromagnet to produce bidirectional forces in response to a variable force command voltage V (sub FC) applied to the electromagnet. A sensor measures the position of the suspended element on the single axis which is a function of force command voltage V (sub FC).

Groom, Nelson J.↗

Description of the Large Gap Magnetic Suspension System (LGMSS) ground-based experiment

A description of the Large Gap Magnetic Suspension System (LGMSS) ground-based experiment is presented. The LGMSS provides five degrees of freedom control of a cylindrical suspended element which is levitated above a floor-mounted array of air core electromagnets. The uncontrolled degree of freedom is rotation about the long axis of the cylinder (roll). Levitation and control forces are produced on a permanent magnet core which is embedded in the cylinder. The cylinder also contains light emitting diodes (LEDs), assorted electrons, and a power supply. The LEDs provide active targets for an optical position measurement system which is being developed in-house at the Langley Research Center. The optical position measurement system will provide six degrees of freedom position information for the LGMSS control system.

Groom, Nelson J.↗

Skeletal muscle response to spaceflight, whole body suspension, and recovery in rats

The effects of a 7-day spaceflight (SF), 7- and 14-day-long whole body suspension (WBS), and 7-day-long recovery on the muscle weight and the morphology of the soleus and the extensor digitorum longus (EDL) of rats were investigated. It was found that the effect of 7-day-long SF and WBS were highly comparable for both the soleus and the EDL, although the soleus muscle from SF rats showed greater cross-sectional area reduction than that from WBS rats. With a longer duration of WBS, there was a continued reduction in cross-sectional fast-twitch fiber area. Muscle plasticity, in terms of fiber and capillary responses, showed differences in responses of the two types of muscles, indicating that antigravity posture muscles are highly susceptible to unloading.

Musacchia, X. J.↗

Air-Bearing-Piston Suspension System

Suspension system based on air-bearing piston holds up steel ball against gravitation while allowing ball to translate vertically and rotate freely. System designed to simulate effect of microgravity on ball. Applicable to suppression of vibrations and delicate machining processes.

Mullen, Donald↗

Magnetic suspension using high temperature superconducting cores

The development of YBCO high temperature superconductors, in wire and tape forms, is rapidly approaching the point where the bulk transport current density j vs magnetic field H characteristics with liquid nitrogen cooling will enable its use in model cores. On the other hand, BSCCO high temperature superconductor in wire form has poor j-H characteristics at 77 K today, although with liquid helium or hydrogen cooling, it appears to be superior to NbTi superconductor. Since liquid nitrogen cooling is approx. 100 times cheaper than liquid helium cooling, the use of YBCO is very attractive for use in magnetic suspension. The design is discussed of a model core to accommodate lift and drag loads up to 6000 and 3000 N respectively. A comparison is made between the design performance of a liquid helium cooled NbTi (or BSCCO) superconducting core and a liquid nitrogen cooled YBCO superconducting core.

Scurlock, R. G.↗

Progress of magnetic suspension and balance systems for wind tunnels in the USSR

Magnetic Suspension and Balance Systems (MSBS) for wind tunnels are being developed in order to solve the principal problems of aerodynamics which cannot be solved by conventional means: (1) measurements of aerodynamic loads acting on the aircraft models without the effects of mechanical supporting devices; and (2) the study of base pressure. This paper traces the progress of MSBS for wind tunnels in the Commonwealth of Independent States (CIS). The paper describes electromagnetic configuration, position sensing, and control and calibration systems of two wind tunnel MSBS existing in the CIS. The features of high-angle-of-attack control and roll control are discussed. The results of preliminary experiments on high-angle-of-attack and roll controls, digital control, and aerodynamic testing are also presented.

Kuzin, A. V.↗

Wind tunnel magnetic Suspension Systems at the University of Southampton, England

The magnetic suspension system at Southampton University was used in two roles: as a device for producing useful aerodynamic data, and as a vehicle to develop and demonstrate new technology for application to a projected larger facility. Examples of both follow, beginning with an outline of the quest to develop methods for reaching high angles of attack because of current interest in researching the associated aerodynamics.

Goodyer, Michael J.↗

Performance of a superconducting large-angle magnetic suspension

SatCon Technology Corporation is working toward the development of an advanced-concept Control Moment Gyro (CMG). The advanced-concept CMG is sized for use as a slewing actuator for large space-based payloads. The design features a magnetically suspended composite rotor which contains a persistent-mode superconducting solenoid magnet. The rotor is suspended and gimballed by the interaction of the fields produced by the superconductor and an array of cryoresistive coils. The rotor spins in a liquid helium environment, while the control coils are liquid-hydrogen cooled. This design is capable of meeting the requirements of many high-performance slewing applications (27,000 Nm). The use of the magnetic suspension as rotor bearings, gimbal bearings, and gimbal torquers also substantially reduces the mass of the CMG system.

Downer, James R.↗

Dynamics and control of a five degree-of-freedom magnetic suspension system

A large-gap magnetic suspension system with five degrees-of-freedom is presented. The system is multi-input/multi-output with coupling between degrees-of-freedom. Simulation was performed on this multi degree-of-freedom system in order to control each degree-of-freedom separately. Two types of controllers are considered by adding white noise to a single degree-of-freedom system in order to test their behavior and determine which is the best choice for the system. The responses of the system are produced in continuous and discrete time where a sample interval and delay time was introduced. Using these responses, a comparison between each degree-of-freedom was made and the maximum value of the delay time was determined.

Haj, Anwar Mohammed↗

A fiber-optic probe for particle sizing in concentrated suspensions

A fiber-optic probe employing two monomode optical fibers, one for transmitting a Gaussian laser beam to the scattering volume and the second, positioned at some backscatter angle, for receiving the scattered light is described. Performance and suitability of the system for a process control environment is assessed by studying a suspension of polystyrene latex particles over a wide range of sizes and concentrations. The results show that the probe is ideal for a process control environment in industrial and laboratory applications. Particle size is recovered, without any additional corrections for multiple light scattering, in concentrations containing up to 10 percent solids of 39-nm polystyrene latex spheres.

Dhadwal, Harbans S.↗

Influences of chemical sympathectomy, demedullation, and hindlimb suspension on the V(O2)max of rats

The contributions of catecholamines from the adrenal medulla to the reduction in maximal oxygen consumption is investigated in chemically sympathectomized rats. The rats are injected with saline and chemically sympathectomized, and approximately half of the rats are surgically demedullated. The subjects undergo head-down suspension for two weeks and are examined in terms of submaximal mechanical efficiency, treadmill run time, and maximal oxygen consumption. Rats with adrenal medullas and injected with saline demonstrate reduced levels of maximal O consumption, whereas chemically sympathectomized rats with adrenal medullas showed no significant reduction. Reduced levels of maximal O consumption is also noted in the sympathectomized demedullated rats. The paper concludes that circulating epinephrine enhances the attenuation of the decrease in the maximal O consumption caused by chemical sympathectomy.

Woodman, Christopher R.↗

Skeletal muscle responses to lower limb suspension in humans

The morphological responses of human skeletal muscle to unweighting were assessed by analyzing multiple transaxial magnetic resonance (MR) images of both lower limbs and skeletal muscle biopsies of the unweighted lower limb before and after six weeks of unilaterial (left) lower limb suspension (ULLS). Results indicated that, as a results of 6 weeks of unweighting (by the subjects walking on crutches using only one limb), the cross sectional area (CSA) of the thigh muscle of the unweighted left limb decreased 12 percent, while the CSA of the right thigh muscle did not change. The decrease was due to a twofold greater response of the knee extensors than the knee flexors. The pre- and post-ULLS biopsies of the left vastus lateralis showed a 14 percent decrease in average fiber CSA due to unweighting. The number of capillaries surrounding the different fiber types was unchanged after ULLS. Results showed that the adaptive responses of human skeletal muscle to unweighting are qualitatively, but not quantitatively, similar to those of lower mammals and not necessarily dependent on the fiber-type composition.

Hather, Bruce M.↗

Muscle strength and endurance following lowerlimb suspension in man

The effect of lower-limb suspension on the muscle strength and muscle endurance was investigated in six men subjected to four weeks of unilateral unloading of a lower limb (using of a harness attached to a modified shoe), followed by seven weeks of weight-bearing recovery. Results showed a decrease in the cross-sectional area (CSA) of the thigh muscle and in the average peak torque (APT) during three bouts of 30 concentric knee extensions. While the the thigh muscle CSA returned to normal after seven weeks of recovery, the APT recovery was still reduced by 11 percent, suggesting that muscle metabolic function was severely affected by unloading and was not restored by ambulation.

Tesch, Per A.↗