Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “steam use data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Phase-rotated MR spectroscopy using dual-PRESS: theory and application in human brain

Phase-rotation spectroscopic acquisition is inherently different from the popular signal-averaging method. Phase-rotation will be described theoretically and experimentally in this article. Traditionally, a single echo is acquired in a PRESS or STEAM sequence at a particular TE. If a long-TE spectrum is desired, then another echo is usually acquired at a longer echo time. We here propose a method by which a pair echoes, at short-TE and a long-TE, are acquired in one experiment, thus saving 50% of total acquisition time without significant sacrifice spectral quality. The phase-rotation approach has been implemented with the proposed method. An additional benefit the proposed Dual-PRESS method, is that it gives an insight into the transverse relaxation time constant, T2, for the various metabolites. The Dual-PRESS method is applied in phantom and in-vivo.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Model for Formation of Dust, Soil and Rock Coatings on Mars: Physical and Chemical Processes on the Martian Surface

This model is one of many possible scenarios to explain the generation of the current surface material on Mars using chemical, magnetic and spectroscopic data From Mars and geologic analogs from terrestrial sites. One basic premise of this model is that the dust/soil units are not derived exclusively from local rocks, but are rather a product of global, and possibly remote, weathering processes. Another assumption in this model is that there are physical and chemical interactions of the atmospheric dust particles and that these two processes create distinctly different results on the surface. Physical processes distribute dust particles on rocks and drift units, forming physically-aggregated layers; these are reversible processes. Chemical reactions of the dust/soil particles create alteration rinds on rock surfaces and cohesive, crusted surface units between rocks, both of which are relatively permanent materials. According to this model the dominant components of the dust/soil particles are derived from alteration of volcanic ash and tephra, and contain primarily nanophase and poorly crystalline ferric oxides/oxyhydroxide phases as well as silicates. These phases are the alteration products that formed in a low moisture environment. These dust/soil particles also contain a smaller amount of material that was exposed to more water and contains crystalline ferric oxides/oxyhydroxides, sulfates and clay silicates. These components could have formed through hydrothermal alteration at steam vents or fumeroles, thermal fluids, or through evaporite deposits. Wet/dry cycling experiments are presented here on mixtures containing poorly crystalline and crystalline ferric oxides/oxyhydroxides, sulfates and silicates that range in size from nanophase to 1-2 pm diameter particles. Cemented products of these soil mixtures are formed in these experiments and variation in the surface texture was observed for samples containing smectites, non-hydrated silicates or sulfates. Reflectance spectra were measured of the initial particulate mixtures, the cemented products and ground versions of the cemented material. The spectral contrast in the visible/near-infrared and mid-infrared regions is significantly reduced for the cemented material compared to the initial soil, and somewhat reduced for the ground, cemented soil compared to the initial soil. The results of this study suggest that diurnal and seasonal cycling on Mars will have a profound effect on the texture and spectral properties of the dust/soil particles on the surface. The model developed in this study provides an explanation for the generation of cemented or crusted soil units and rock coatings on Mars and may explain albedo variations on the surface observed near large rocks or crater rims.

Bishop, Janice↗

Temperature Evolution and Oxide Growth in Waterwall Tubes of Supercritical Units

In order to understand the failures in some waterwall tubes of supercritical steam boilers, an analysis is required to estimate the temperature of the waterwall tubes and the oxide growth in these tubes. A review on the thermophysical properties of oxide grown in waterwall tubes was conducted. Specimens of waterwall tubes associated with thermal fatigue cracking were obtained and microstructural analyses, using metallographic and electron-optical techniques such as SEM and electron-probe microanalysis, were performed. A computer model is being developed to estimate the maximum temperature in waterwall tubes by considering several phenomena that take place in supercritical units. The comprehensive model includes the following boiler operation features and phenomena: oxide growth, distribution of the heat flux on the waterwall tube as a function of height distance, variation of steam flow rate due to load variation, variation of heat flux due to load variation, and variation of the heat transfer coefficient with steam conditions and furnace heat flux. The model will handle the transition subcritical-to-supercritical and will account for the heat transfer deterioration phenomena in tubes. The tube regions with deteriorated heat transfer regimes will be identified. The temperatures of steam, metal, and oxide will be obtained as a function of the height distance in the boiler. The mixing effects of the steam from different waterwall tubes and subsequent fluid dynamics effects on the heat transfer will be considered. The new model will enable the prediction of the maximum metal temperature for realistic boiler operation schedule, which include transitions from full-to-low loads. Based on the estimated data for the steam temperature, metal temperature, and oxide thickness, regions of the waterwall tubes that are exposed to the most severe conditions will be identified.

20 FOSSIL-FUELED POWER PLANTS↗

High Fidelity Dynamic Simulation of Cycling in a Natural Gas Combined Cycle Power Plant

The CRADA objective is to use a high-fidelity natural gas combined cycle (NGCC) dynamic simulator deployed at the National Energy Technology Laboratory (NETL) to produce practical engineering ideas that would either reduce the impact on equipment resulting from cycling, or improve certain plant operational modes. The goal is to demonstrate to National Rural Electric Cooperative Association (NRECA) that a high-fidelity dynamic simulator offers a relatively low-cost option for investigation and testing without direct plant experimentation. Initial operation of the simulator revealed the potential for saturation conditions in the final high pressure superheater as the attemperator tried to control temperature at the superheater outlet during gas turbine loading and unloading. Subsequent plant operational data confirmed simulation results. Thus, this particular area was chosen for further investigation. Multiple simulations were performed during loading and unloading of the gas turbine in order to determine operational strategies that prevented saturation and increased the approach to saturation temperature. The results of these simulations are presented in this report. The summary at the end of this report suggests trials that could be performed at the plant to confirm the benefits seen by simulator investigations, such as changes to the attemperator temperature control setpoints and strategic control of the steam turbine inlet pressure control valve.

03 NATURAL GAS↗

Theory and Implementation of Nuclear Safety System Codes - Part II: System Code Closure Relations, Validation, and Limitations

This is Part II of two articles describing the details of thermal-hydraulic sys- tem codes. In this second part of the article series, the system code closure relationships (used to model thermal and mechanical non-equilibrium and the coupling of the phases) for the governing equations are discussed and evaluated. These include several thermal and hydraulic models, such as heat transfer coefficients for various flow regimes, two phase pressure correlations, two phase friction correlations, drag coefficients and interfacial models be- tween the fields. These models are often developed from experimental data. The experiment conditions should be understood to evaluate the efficacy of the closure models. Code verification and validation, including Separate Effects Tests (SETs) and Integral effects tests (IETs) is also assessed. It can be shown from the assessments that the test cases cover a significant section of the system code capabilities, but some of the more advanced reactor designs will push the limits of validation for the codes. Lastly, the limitations of the codes are discussed by considering next generation power plants, such as Small Modular Reactors (SMRs), analyz- ing not only existing nuclear power plants, but also next generation nuclear power plants. The nuclear industry is developing new, innovative reactor designs, such as Small Modular Reactors (SMRs), High-Temperature Gas-cooled Reactors (HTGRs) and others. Sub-types of these reactor designs utilize pebbles, prismatic graphite moderators, helical steam generators, in- novative fuel types, and many other design features that may not be fully analyzed by current system codes. This second part completes the series on the comparison and evaluation of the selected reactor system codes by discussing the closure relations, val- idation and limitations. These two articles indicate areas where the models can be improved to adequately address issues with new reactor design and development.

99 GENERAL AND MISCELLANEOUS↗

Mechanism for Acetone and Crotonaldehyde Production during Steam Reforming of Ethanol over La 0.7 Sr 0.3 MnO 3–x Perovskite: Evidence for a Shared C4 Aldol Addition Intermediate

Here a mechanistic study was conducted on the catalytic conversion of ethanol over La 0.7 Sr 0.3 MnO 3–x perovskite catalysts in the presence and absence of water. The study sought insights into the path of C–C coupling toward acetone and crotonaldehyde and also into clarifying whether the lack of previous reports of C–C coupling over La 0.7 Sr 0.3 MnO 3–x (100) could be due to a “pressure gap”. Several types of experiments were performed at 400–800 K: flow experiments with a torr range reactant gas flown over La 0.7 Sr 0.3 MnO 3–x powders; ultra-high vacuum experiments with continuous gas exposures to a La 0.7 Sr 0.3 MnO 3–x (100) single-crystal sample; and torr range continuous gas exposures to a La 0.7 Sr 0.3 MnO 3–x (100) single-crystal sample. When ethanol and water were flown over La 0.7 Sr 0.3 MnO 3–x powders at 400–800 K, the products detected were ethene, acetaldehyde, acetone, crotonaldehyde, CO, CO 2 , and H 2 . Acetone was catalytically produced over both the La 0.7 Sr 0.3 MnO 3–x powder and the La 0.7 Sr 0.3 MnO 3–x (100) single-crystal sample at temperatures of 700–800 K when reaction conditions were on the order of 1 Torr of reactant gas and with an excess of water relative to ethanol (1 ethanol/9 water). Isotopic labeling with deuterium was used to gain insights into the C–C coupling reaction mechanism and paths in species with three and four carbons (C 3 and C 4 species). Additionally, steady-state isotopic transient kinetic analysis (SSITKA) experiments + simulations using carbon labeling of the ethanol feed were performed. Three mechanistic paths were considered for the C–C coupling step: the first two paths, A and B, involve coupling between two intermediates which are both in oxygen vacancies; and the third path, C, involves coupling between one intermediate in an oxygen vacancy and one intermediate outside of an oxygen vacancy. The results suggest that the dominant path to the C 3 product, acetone, depends on the conditions. The less active path (attributed to path A or B) occurs at 600–700 K and involves coupling between two irreversibly bound species. The more active path (attributed to path C) requires an excess of water, becomes dominant at 600–800 K, and involves coupling between one irreversibly bound species and one reversibly bound species. Based on these various observations from experiments and simulations, an elementary step is proposed for acetone formation involving a previously unreported C 4 transition state that is formed after aldol addition. Density functional theory calculations were performed based on this hypothesis, and it confirmed that this specific and previously unreported aldol addition path to acetone does exist and that this path consistent with the experimental data. In this path, C–C formation occurs to create a C 4 intermediate that is bound to an oxygen vacancy, then a hydrogen transfer with C–C bond breaking occurs that results in the production of the acetone molecule. The proposed mechanism is also consistent with the experimental observation that acetone formation has a greater than first-order dependence on the water vapor pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Technology Maturation of Wireless Harsh Environment Sensors For Improved Condition Based Monitoring Of Coal Fired Power Generation

The overall goal of this project was to demonstrate and develop the usage of high-temperature (HT) harsh-environment (HE) wireless surface acoustic wave resonator (SAWR) sensor technology to promote reliable maintenance through condition-based maintenance (CBM) for field applications in harsh service conditions associated with power plant environments. The project aimed to advance the HT HE wireless SAWR sensor technology from TRL 5 to TRL 7. In addition to HT HE wireless temperature sensing, efforts were dedicated during this project to investigate, develop and increase the TRL from 3 to 5 for the following technologies: (a) HT HE strain sensors to address additional CBM monitoring needs, such as boiler tube mechanical / thermal stresses, which can provide early indications for boiler tube cracking and failure; and (b) HT aluminum nitride (AlN) and scandium aluminum nitride (ScAlN) based piezoelectric thin film fabrication and implementation of SAW sensors, with the goal of releasing the need to use single crystal piezoelectric materials for SAWRs and thus broaden possible technology applications to non-planar and harder to modify surfaces. To achieve the goals mentioned above, UMaine and its partner, Environetix Technologies Corporation, established partnerships with the following power plants: Longview Power (Maidsville, WV), a coal-fired power plant; Penobscot Energy Recovery Corp (PERC, Orrington, ME), a waste-to-energy power plant; and the UMaine Steam Plant (Orono, ME), an oil / natural gas power plant. To realize wireless HT HE SAWR sensor systems in these harsh service conditions, the University of Maine research team worked with Environetix and these power plants to define, design, fabricate, test and validate a mature prototype wireless temperature SAWR sensor system for boiler tube applications within the HT HE of the reheater pass damper chamber to directly and wirelessly monitor the temperature at eighteen independent boiler tube locations. The system included three levels, or “tiers”, of wireless communication to enable remote monitoring: Tier 1, the wireless link in the reheater pass damper chamber directly accessing the sensors on the boilers; Tier 2, the wireless local area network link, transmitting processed sensor information within the power plant to the Tier 3, a commercial wireless signal carrier company for secure remote data monitoring outside of the power plant. Regarding the wireless sensor system installed at Longview Power, temperature information from the boilers was continuously transmitted from the Longview boilers at Maidsville, WV, to Environetix headquarters, Orono, ME, over a 34 month period, when the system was finally decommissioned. Strain sensors and piezoelectric ScAlN thin film sensors were successfully installed on the exhaust duct at the UMaine Steam Power plant. The advances in wireless strain sensors and thin film piezoelectric film fabrication and testing were performed mostly in UMaine laboratories and field tested at the UMaine Steam Plant, due to its close proximity to UMaine/Environetix, access to the plant facility, and due to difficulties in accessing the other power plants during the COVID shut-down period. The project accomplished the TRL level increase of the targeted CBM technologies through the successful fabrication, installation, test, and validation of dedicated and commercial wireless sensor systems, utilizing the three different power plants. The outcomes of this project, including the wireless sensor data capability, are expected to yield an advance for CBM in harsh power plant environments. The reduction of maintenance costs, improved safety during plant operation, and increased power plant efficiency will lead to increased revenues (i.e., fewer forced outages) due to better process monitoring enabled by the wireless HT HE SAWR temperature sensor technology.

20 FOSSIL-FUELED POWER PLANTS↗

Root Cause Analysis of Degradation in Protonic Ceramic Electrochemical Cell with Interfacial Electrical Sensors Using Data‐Driven Machine Learning

Abstract Protonic ceramic electrochemical cells (PCECs) offer promising paths for energy storage and conversion. Despite considerable achievements made, PCECs still face challenges such as physiochemical compatibility between componenets and suboptimal solid–solid contact at the interfaces between the electrolytes and electrodes. In this study, a novel approach is proposed that combines in situ electrochemical characterization of interfacial electrical sensor embedded PCECs and machine learning to quantify the contributions of different cell components to total degradation, as well as to predict the remaining useful life. The experimental results suggest that the overpotential induced by the oxygen electrode is 48% less than that of oxygen electrode/electrolyte interfacial contact for up to 1171 h. The data‐driven machine learning simulation predicts the RUL of up to 2132 h. The root cause of degradation is overpotential increase induced by oxygen electrode, which accounts for 82.9% of total cell degradation. The success of the failure diagnostic model is demonstrated by its consistency with degradation modes that do not manifest in electrolysis fade during early real operations. This synergistic approach provides valuable insights into practical failure diagnosis of PCECs and has the potential to revolutionize their development by enabling improved performance prediction and material selection for enhanced durability and efficiency.

25 ENERGY STORAGE↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM - PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that come in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter off-gas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MODELING THE IMPACT OF ELEVATED MERCURY IN DEFENSE WASTE PROCESSING FACILITY MELTER FEED ON THE MELTER OFF-GAS SYSTEM-PRELIMINARY REPORT

The Defense Waste Processing Facility (DWPF) is currently evaluating an alternative Chemical Process Cell (CPC) flowsheet to increase throughput. It includes removal of the steam-stripping step, which would significantly reduce the CPC processing time and lessen the sampling needs. However, its downside would be to send 100% of the mercury that comes in with the sludge straight to the melter. For example, the new mercury content in the Sludge Batch 5 (SB5) melter feed is projected to be 25 times higher than that in the SB4 with nominal steam stripping of mercury. This task was initiated to study the impact of the worst-case scenario of zero-mercury-removal in the CPC on the DWPF melter offgas system. It is stressed that this study is intended to be scoping in nature, so the results presented in this report are preliminary. In order to study the impact of elevated mercury levels in the feed, it is necessary to be able to predict how mercury would speciate in the melter exhaust under varying melter operating conditions. A homogeneous gas-phase oxidation model of mercury by chloride was developed to do just that. The model contains two critical parameters pertaining to the partitioning of chloride among HCl, Cl, Cl{sub 2}, and chloride salts in the melter vapor space. The values for these parameters were determined at two different melter vapor space temperatures by matching the calculated molar ratio of HgCl (or Hg{sub 2}Cl{sub 2}) to HgCl{sub 2} with those measured during the Experimental-Scale Ceramic Melter (ESCM) tests run at the Pacific Northwest National Laboratory (PNNL). The calibrated model was then applied to the SB5 simulant used in the earlier flowsheet study with an assumed mercury stripping efficiency of zero; the molar ratio of Cl-to-Hg in the resulting melter feed was only 0.4, compared to 12 for the ESCM feeds. The results of the model run at the indicated melter vapor space temperature of 650 C (TI4085D) showed that due to excessive shortage of chloride, only 6% of the mercury fed is expected to get oxidized, mostly as HgCl, while the remaining mercury would exist either as elemental mercury vapor (90%) or HgO (4%). Noting that the measured chloride level in the SB5 qualification sample was an order of magnitude lower than that used in the SB5 simulant, the degree of chloride shortage will be even greater. As a result, the projected level of HgCl in the actual SB5 melter exhaust will be even lower than 6% of the total mercury fed, while that of elemental mercury is likely to be greater than 90%. The homogeneous oxidation of mercury in the off-gas was deemed to be of primary importance based on the postulation that mercury and other volatile salts form submicron sized aerosols upon condensation and thus remain largely in the gas stream downstream of the quencher where they can deposit in the off-gas lines, Steam-Atomized Scrubbers (SAS), and High-Efficiency Mist Eliminator (HEME). Formation of these submicron semi-volatile salts in the condensate liquid is considered to be unlikely, so the liquid phase reactions were considered to be less important. However, subsequent oxidation of mercury in the liquid phase in the off-gas system was examined in a simplified model of the off-gas condensate. It was found that the condensate chemistry was consistent with further oxidation of elemental mercury to Hg{sub 2}Cl{sub 2} and conversion of HgO to chlorides. The results were consistent with the available experimental data. It should also be noted that the model predictions presented in this report do not include any physically entrained solids, which typically account for much of the off-gas carryover on a mass basis. The high elemental mercury vapor content predicted at the DWPF Quencher inlet means that physically entrained solids could provide the necessary surface onto which elemental mercury vapor could condense, thereby coating the solids as well as the internal surfaces of the off-gas system with mercury. Clearly, there are many process benefits to be gained by removing the steam-stripping step from the CPC cycle. The goal of this task was to study what adverse impact the zero-mercury-removal scenario would have on the DWPF melter off-gas system operation. It is stressed again that this study was intended to be scoping in nature, so the results presented in this report are preliminary. Any further substantiation of these results for actual implementation into the DWPF flowsheet would require an in-depth modeling study of all three reaction zones, including the aqueous-phase reactions in the quencher, OGCT, Steam Atomized Scrubber (SAS), and off-gas condenser with recirculated condensate, and the proof-of-principle experiments.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pseudo-dynamic Aspen Plus{sup R} Model of the Defense Waste Processing Facility - 18475

The Defense Waste Processing Facility (DWPF) at the Savannah River Site converts legacy high-level waste from the Cold War into borosilicate glass for permanent disposal in a geological repository. The waste sludge is chemically adjusted by the addition of acid, mixed with frit, and concentrated in the DWPF Chemical Process Cell (CPC) to ensure that the final glass has the desired properties. The resulting mixture is fed into the melter where the waste is melted and poured into stainless steel storage canisters. We present an Aspen Plus{sup R} model of the DWPF CPC, which is being developed to aid chemical processing decisions pertaining to the current flowsheet and to aid decisions regarding optimizing future processing. Given a waste feed composition with acid and frit additions, the model will predict the sludge and off-gas compositions throughout the processing, as well as the final melter feed composition. This allows different processing scenarios to be investigated easily, reducing the reliance on experimental testing, and hence saving time and money. The model has multiple potential applications, including calculating the acid and frit additions required to give acceptable glass properties, off-gas permitting, tracking mercury steam-stripped from the waste in the off-gas system, tracking flammable gases in the offgas system, investigating the effect of reducing air purges in the condensers, and general process optimization. The waste is processed in the CPC in batches, requiring dynamic simulation to track the time-dependent operations. Accurate modeling of the processing also requires calculations of phase and electrolyte chemical equilibria and parallel rate-dependent reactions. Due to existing technical limitations with dynamic simulation of the complex chemical system, we have adopted a pseudo-dynamic approach in which time intervals are treated as consecutive steady-state operations in Aspen Plus{sup R}. Thus, the model consists of ∼100 replicas of the processing vessel and its off-gas system, with the sludge output by one replica (representing one time interval) becoming the feed to the next (representing the next time interval). By examining the results from these replicas in sequence, one can see the time evolution of the model. This general approach can be used wherever simultaneous calculation of phase and electrolyte chemical equilibria in a dynamically evolving system is needed. In addition to describing the general structure and chemistry of the model, we present results from tests of the model against experimental data. These data are from laboratory-scale process simulations of the CPC with a nonradioactive waste sludge simulant. These tests include the model's predictions of the offgas composition, the sludge pH, and the final sludge composition. We will also discuss planned future developments of the model. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fuel Performance Simulation of Iron-Chrome-Aluminum Cladding during Steady-State LWR Operation

During a severe accident scenario, such as a loss-of-coolant accident, a nuclear reactor may lose its capacity to cool its fuel. The fuel rod temperatures begin to increases, quickly reaching temperatures where the coolant begins to evaporate. This lowers the coolant level in the core and eventually uncovers the fuel. Without sufficient heat transfer from the fuel rods to the coolant, the temperature of the fuel and cladding will increase dramatically. In the case of traditional zirconium-based alloys, as the temperature of the cladding reaches ∼1200 deg. C the zirconium rapidly begins to oxidize with H{sub 2}O in the coolant and steam. This oxidation reaction causes both thinning of the Zr-alloy cladding as the metal reacts and releases large amounts of H{sub 2} gas into the reactor pressure vessel. In order to increase the safety margin of LWR fuel in severe accident scenarios, several alternative cladding materials have been proposed to replace the currently used zirconium-based alloys. Of these materials, there is a particular focus on select iron-chrome-aluminum (FeCrAl) alloys because of slower oxidation Kinetics in high temperature steam than zirconium-based alloys. This increased oxidation resistance may provide additional coping time to mitigate any further damage resulting from an accident. However, by changing the cladding material, the neutronic characteristics of the core will change. FeCrAl alloys exhibit thermal neutron absorption cross sections nearly ∼12-16 x greater than Zr-alloys. This decreases the reactivity of the core, subsequently decreasing the potential cycle length for operation. To counteract this, fissile material may be added in the form of increased enrichment or increased fuel mass or the cladding thickness might be decreased, effectively reducing the neutronic penalty from using the alloy. In this study, all three changes are considered. To assess the viability of FeCrAl as an alternative cladding to Zr-alloys, engineering-scale fuel performance analysis is used to monitor the cladding and integral fuel rod behavior through its operation. Ongoing work is being performed to identify key parameters essential to modeling FeCrAl alloys for LWR applications and properly model fuel compliance and stress relief mechanisms for UO{sub 2} fuel. To improve the predictive capability of fuel performance codes for FeCrAl cladding under normal operation, high-fidelity mechanistic/physics-based material models are needed. This information can be generated and improved by access to experimental data on targeted FeCrAl alloys. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Derivation and assessment of regional electricity generation emission factors in the USA

Electricity production is one of the largest sources of environmental emissions - especially greenhouse gases (GHGs) - in the USA. Emission factors (EFs) vary from region to region, which requires the use of spatially relevant EF data for electricity production while performing life cycle assessments (LCAs). Uncertainty information, which is sought by LCA practitioners, is rarely supplied with available life cycle inventories (LCIs). To address these challenges, we present a method for collecting data from different sources for electricity generation and environmental emissions; discuss the challenges involved in agglomerating such data; provide relevant suggestions and solutions to merge the information; and calculate EFs for electricity generation processes from various fuel sources for different spatial regions and spatial resolutions. The EFs from the US 2016 Electricity Life Cycle Inventory (eLCI) are analyzed and explored in this study. We also explore the method of uncertainty information derivation for the EFs. We explore the EFs from different technologies across Emissions & Generation Resource Integrated Database (eGRID) regions in the USA. We find that for certain eGRID regions, the same electricity production technology may have worse emissions. This may be a result of the age of the plants in the region, the quality of fuel used, or other underlying factors. Region-wise life cycle impact assessment (LCIA) ISO 14040 impacts for total generation mix activities provide an overview of the total sustainability profile of electricity production in a particular region, rather than only global warming potential (GWP). We also find that, for different LCIA impacts, several eGRID regions are consistently worse than the US average LCIA impact for every unit of electricity generated. Here this work describes the development of an electricity production LCI at different spatial resolutions by combining and harmonizing information from several databases. The inventory consists of emissions, fuel inputs, and electricity and steam outputs from different electricity production technologies located across various regions of the USA. This LCI for electricity production in the USA will prove to be an enormous resource for all LCA researchers - considering the detailed sources of the information and the breadth of emissions covered by it.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Pre-Project Planning for a Flameless Pressurized Oxy-Combustion Pilot Plant (Final Technical Report)

The team of Southwest Research Institute® (SwRI®), ITEA, Electric Power Research Institute, Inc. (EPRI), GE Global Research (GE), Jacobs Engineering (Jacobs), and Peter Reineck Associates (PRA) are advancing Flameless Pressurized Oxy-Combustion (FPO), a novel coal technology. This effort seeks to complete the preliminary engineering and planning of a 50-MWth Pilot Plant that produces electricity and steam for district heating. The technology, pioneered by ITEA at the 5-MWth scale, must be brought to a higher technology readiness level (TRL) to be viable at the commercial scale. This project builds upon extensive evaluation of the techno-economic performance of the FPO technology already performed by ITEA. This includes system improvements, such as the addition of a turbo-expander to the flue gas stream. Some of the performance-enhancing components are not as well defined as others. The primary goal of this project was to bring all of the core cycle components to the same level of design maturity. Extensive cycle modeling and evaluation explored various configurations of the process. Different coals, operating conditions, and heat recovery devices were considered and modeled using Aspen Plus. The results of the cycle modeling informed the pilot plant configuration and the planned configuration at the commercial scale. The system pressurization is maintained in the flue gas clean-up and water removal. This allows for efficient and cost-effective carbon dioxide compression and sequestration package. Once the cycle was optimized, preliminary drawings, layouts, and plans defined the pilot facility. Process flow diagrams (PFD) were used to describe the pilot configuration in greater detail. A heat and mass balance with stream data was created. A master equipment list specified the operating conditions for major pieces of equipment within the pilot using this heat and mass balance. A detailed cost estimate for the planned configuration was completed with an Association for the Advancement of Cost Engineering (AACE) Class IV level of cost analysis. A site selection effort evaluated a variety of potential candidate sites. The selection effort focused on three sites for an in-depth evaluation of the merits and viability of hosting a pilot demonstration. The ability of the host site to support the project with cost sharing was also assessed. The selection process chose the University of Wyoming (UW) as the host site, and cost estimates for the pilot capital estimate were made using local data. A preliminary test plan and operation plan, which creates figures of merit, control, and instrumentation was produced. An effort that outlines methods of pilot cost reduction was completed near the end of the project. A techno-economic assessment (TEA) evaluated the FPO technology at the commercial scale in comparison to the NETL baseline cases. The reference plants were used in combination with proprietary equipment estimates to build a plant capital cost and cost of electricity evaluation. FPO performed better than the sub-bituminous post-combustion capture cases. Further preliminary estimates of improvements to the FPO cycle show even further gains when compared to conventional carbon capture methods.

01 COAL, LIGNITE, AND PEAT↗

Solid Oxide Fuel Cell Systems PVL Line

In July 2010, Stark State College (SSC), received Grant DE-EE0003229 from the U.S. Department of Energy (DOE), Golden Field Office, for the development of the electrical and control systems, and mechanical commissioning of a unique 20kW scale high-pressure, high temperature, natural gas fueled Stack Block Test System (SBTS). SSC worked closely with subcontractor, Rolls-Royce Fuel Cell Systems (US) Inc. (RRFCS) over a 13 month period to successfully complete the project activities. This system will be utilized by RRFCS for pre-commercial technology development and training of SSC student interns. In the longer term, when RRFCS is producing commercial products, SSC will utilize the equipment for workforce training. In addition to DOE Hydrogen, Fuel Cells, and Infrastructure Technologies program funding, RRFCS internal funds, funds from the state of Ohio, and funding from the DOE Solid State Energy Conversion Alliance (SECA) program have been utilized to design, develop and commission this equipment. Construction of the SBTS (mechanical components) was performed under a Grant from the State of Ohio through Ohio's Third Frontier program (Grant TECH 08-053). This Ohio program supported development of a system that uses natural gas as a fuel. Funding was provided under the Department of Energy (DOE) Solid-state Energy Conversion Alliance (SECA) program for modifications required to test on coal synthesis gas. The subject DOE program provided funding for the electrical build, control system development and mechanical commissioning. Performance testing, which includes electrical commissioning, was subsequently performed under the DOE SECA program. Rolls-Royce Fuel Cell Systems is developing a megawatt-scale solid oxide fuel cell (SOFC) stationary power generation system. This system, based on RRFCS proprietary technology, is fueled with natural gas, and operates at elevated pressure. A critical success factor for development of the full scale system is the capability to test fuel cell components at a scale and under conditions that can be accurately extrapolated to full system performance. This requires specially designed equipment that replicates the pressure (up to 6.5 bara), temperature (about 910 C), anode and cathode gas compositions, flows and power generation density of the full scale design. The SBTS fuel cell anode gas is produced through the reaction of pipeline natural gas with a mixture of steam, CO2, and O2 in a catalytic partial oxidation (CPOX) reactor. Production of the fuel cell anode gas in this manner provides the capability to test a fuel cell with varying anode gas compositions ranging from traditional reformed natural gas to a coal-syngas surrogate fuel. Stark State College and RRFCS have a history of collaboration. This is based upon SSCAs commitment to provide students with skills for advanced energy industries, and RRFCS need for a workforce that is skilled in high temperature fuel cell development and testing. A key to this approach is the access of students to unique SOFC test and evaluation equipment. This equipment is designed and developed by RRFCS, with the participation of SSC interns. In the near-term, the equipment will be used by RRFCS for technology development. When this stage is completed, and RRFCS has moved to commercial products, SSC will utilize this equipment for workforce training. The RRFCS fuel cell design is based upon a unique ceramic substrate architecture in which a porous, flat substrate (tube) provides the support structure for a network of solid oxide fuel cells that are electrically connected in series. These tubes are grouped into a {approx}350-tube repeat configuration, called a stack/block. Stack/block testing, performed at system conditions, provides data that can be confidently scaled to full scale performance. This is the basis for the specially designed and developed test equipment that is required for advancing and accelerating the RRFCS SOFC power system development program. All contract DE-EE0003229 objectives were achieved and deliverables completed during the period from March 1, 2010 through March 31, 2011. As a result of program completion, the Stack Block Test System was ready to support installation and electrical operation of a RRFCS solid oxide fuel cell (SOFC) stack block in the second quarter of 2011.

01 COAL, LIGNITE, AND PEAT↗

Design and Experimental Demonstration of an Additive Manufactured Smart Oxy-Methane Burner for High Pressure and Supercritical Combustion

Pressurized oxy combustion-based systems can improve efficiency by recovering latent heat of the steam in the Flue Gas and achieving 90% CO2 capture. In addition, the novel Directly Heated Supercritical Carbon Dioxide (DH-SCO2) power cycles can achieve high thermal efficiencies and provide nearly full carbon capture. Additionally, due to the reduction of flue gas at higher pressure, smaller system size and capital cost reductions are also possible. Recent thermodynamic analysis of the DH-SCO2 cycle performed by the UTEP research team shows that combustion conditions in the vicinity of 300 bar pressure and 1000-1400 K temperature allow for relatively high system efficiencies while operating within the limit of available combustor materials. However, the realization of a directly heated supercritical power cycle requires combustion systems to operate in supercritical conditions and at temperature far below the blowout limit of conventional flames (above 1500 K). The thermodynamic properties along with the combustion properties and kinetics are unexplored at such conditions. Additionally, the interaction of the supercritical environment with energy components is also unknown. High-pressure combustion tests are performed using a smart burner at some intermediate pressure ranges (<20 bar) to help minimize these knowledge gaps. The knowledge obtained from the high-pressure test will assist in understanding the combustion chamber pressurization mechanism, ignition and flame behavior at the elevated pressure. The obtained data will act as a systematic first step in testing at higher pressures of 100 and 300 bar pressures.The primary purpose of this Dissertation is to demonstrate the operability of a low NOx smart burner for oxy-methane combustion at high pressure (< 20 bar) and scalable up to supercritical conditions. A shear co-axial smart burner is designed with a real-time temperature monitoring capability to understand the burner face interaction at high-pressure conditions. In addition, the burner has four independent injection ports to allow the independent injection of fuel and dilution gases in the combustor. The maximum operating capability of the burner is 575 kWth. The burner was fabricated using a Laser Powder Bed Fusion process with Nickel Alloy 718. A powder removal technology was invented comprising ultrasonic vibration, liquid nitrogen exposure and media blasting to remove powders from internal channels of the burner. The burner operability tests are performed in the high-pressure combustor and the swirl combustor. The high-pressure combustor was used to investigate the burner operability and thermal soak back at different pressurized conditions. The experimental tests in high-pressure combustor up to 275 kWth input resulted in 16.5 bar chamber pressure and 198°C thermal soaks back to the burner. The burner was capable of providing the required thermal input within a 3% deviation range. In addition, soot formation occurred at high-pressure tests. The swirl combustor was used to observe the flame stability of the burner. Flame lift-off was observed for jet velocities above 450 m/s. Additionally, lift-off decreased for low co-flow velocities. CO2 dilution experiments showed increased flame instabilities for all conditions above 50% dilution ratios. At lower thermal inputs, partial flame blow-offs occurred for dilution ratios above 50%. All conditions significantly reduced the flame temperature and increased the flame lift-off height. Finally, a 2nd generation AM smart burner was designed using the knowledge from the 1st generation burner experiments. The 2nd generation burner incorporated two sets of swirlers with 0.9 swirl no. A cooling system was also designed for long-duration tests at higher pressures. The thermal input and division of the burner's power are kept the same as the 1st generation burner. The burner is to be fabricated using nickel-alloy 718 for high-pressure handling capability. The design can sustain at high-pressure conditions up to 100 bar.

Islam, Md Nawshad Arslan↗

A high-temperature mixed potential CO gas sensor for in situ combustion control

An in situ, accurate and robust sensor that can sustain a high temperature of above 1000 °C is needed for on-site combustion monitoring because it can give real-time and local data to the control system to adjust the overall combustion efficiency. In this work, we find that nickel oxide (NiO) is a promising sensing material for CO which is a direct indicator of the status of the combustion process of a power plant. Under the conditions of 0.5–3% O 2 and 1000 °C, the fabricated yttrium-stabilized zirconia (YSZ)-based mixed potential sensor using porous NiO demonstrates good sensitivity to CO, showing a signal as high as 36 mV to 1000 ppm CO. The effects of gas transport, structure and geometry of the NiO electrode on the sensing performance are studied. Results show that fast gas transport is much beneficial to improved sensitivity. NiO having a porous structure is much more sensitive to CO than that having a dense structure. But the t90 (time to achieve 90% final signal magnitude) of the former is much longer due to slower gas diffusion inside the pores. It's worth noting that the NiO sensor exhibits a positive relationship with the CO content, opposite to other reported results of mixed potential sensors to detect CO. We find that this might be due to the electrochemical reduction, instead of oxidation of CO during the interaction with NiO at 1000 °C. Selectivity tests on how CO 2 , CH 4 and steam affect CO sensing are also demonstrated. NiO is insensitive to even 10% CO 2 . CH 4 does not shift the average value of the CO sensing response. However, it makes the sensing signal fluctuate more intensively. 2% steam exerts a great influence on NiO sensitivity to CO: it magnifies the sensitivity of the porous NiO electrode to a low CO range of 0–100 ppm, but inhibits its sensitivity to a CO range of 100 ppm to 1000 ppm. Lastly, an 11 day stability test demonstrates the promising stability property of the proposed NiO-based YSZ sensor.

20 FOSSIL-FUELED POWER PLANTS↗

Leveraging Existing Assets for Long Duration Energy Storage

Increased renewables penetration to electrical grid is necessary to reduce overall emissions from the electrical power generation sector. Nonetheless, its integration creates challenges to grid operators who must match the power being generated by intermittent renewables and other traditional energy sources with the demand from consumers, while ensuring the reliability and power quality for the entire system. Energy storage has been proposed as an alternative to natural gas peaking plants and a form to deliver excess renewable energy generation at times of peak demand. For energy storage to provide benefits to end customers (energy consumers), it must be reliable, efficient, and cost effective. The Illinois Sustainable Technology Center (ISTC), one of the surveys that integrate the Prairie Research Institute (PRI), aims to develop a Center for Energy Storage at Existing Assets (CESEA) at UIUC with the participation of Waste Pressure Corp and Ecotek Engineering USA LLC. CESEA will focus on LDES systems that can integrate to existing infrastructure in a manner that reduces the initial capital expenditure and demonstrates the ability to repurpose fossil assets that would otherwise become stranded, to serve the energy transition. CESEA aims to leverage UIUC’s unique facilities to validate LDES systems performance at a relevant operating environment. UIUC’s facilities include a 85-MW combined heat and power (CHP) power plant, two (2) solar PV plants totaling over 18 MWdc of installed capacity, an electrical grid along with a substation at transmission and distribution voltages, a 22-mile gas pipeline network operating at two pressure levels, along with steam and chilled water distribution networks. The new LDES systems will connect to the existing UIUC grid through a new test electrical station, which will have the capacity to accommodate additional connections to test new devices and technologies as part of future CESEA R&D activities. The test electrical station will contain meters, instrumentation, and controls to accurately capture data and allow optimization of control algorithms. CESEA will initially focus on technologies that: i) utilize existing equipment or facilities to perform at least one of the process steps in LDES (charging, storage, or discharging), ii) leverage mature or commercially available components or controls, iii) show potential for cost-leadership in 10+ hour storage at a commercial scale. Initial technologies that were identified to meet these criteria include Compressed Gas Energy Storage (CGES), and TES. CGES stores electricity by raising the pressure of a compressible gas inside a control volume and converting the stored energy to electricity via expansion-generation. CGES is a generalization of CAES that covers any working gas (not just air). A successful CGES demo will help to circumvent many challenges faced by CAES (long development times due to site prospecting, high cost of compression and storage, heat recovery management, etc.) by: 1) utilizing existing infrastructure (compressors, pipelines, underground storage or pressure vessels) used in the transportation and storage of industrial gases for LDES charging and storage; 2) deploying over sites already-developed for industrial applications with minor additional work; 3) leveraging the price structure of commercial industrial gas to cover the costs of electricity used during charging. A previous DOE-sponsored conceptual study (DE-FE-0032018) estimated the levelized cost of energy of a 1.1 MW / 17 MWh CGES system at $0.08/kWh, with a commercial 10x scale system cost estimated at <$0.04/kWh (Giardinella, 2022). The pilot-sized system was estimated to avoid up to 2693 tons of CO2/year.

25 ENERGY STORAGE↗