Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “static testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Solid propellant engineering

Surface temperature relations for ignition material deflagration onset, and static tests of Applications Technology Satellite motor

Source record↗

Solid-propellant motors for high-incremental-velocity low-acceleration maneuvers in space

The applicability of solid-propellant rockets into a regime of high-performance long-burning tasks beyond the capability of existing motors is discussed. Successful static test firings have demonstrated the feasibility of: (1) utilizing fully case-bonded end-burning propellant charges without mechanical stress relief; (2) using an all-carbon radiative nozzle markedly lighter than the flight-weight ablative nozzle it replaces, and (3) producing low spacecraft acceleration rates during the thrust transient through a controlled-flow igniter that promotes operation below the previous combustion limit.

Shafer, J. I.↗

Evaluation of boron-epoxy-reinforced titanium tubular truss for application to a space shuttle booster thrust structure

Results of a study to demonstrate the applicability of boron-epoxy-composite-reinforced titanium tubular members to a space shuttle booster thrust structure are presented and discussed. The experimental results include local buckling of all-composite and composite-reinforced-metal cylinders with low values of diameter-thickness ratio, static tests on composite-to-metal bonded step joints, and a test to failure of a boron-epoxy-reinforced titanium demonstration truss. The demonstration truss failed at 118 percent of design ultimate load. Test results and analysis for all specimens and the truss are compared. Comparing an all-titanium design and a boron-epoxy-reinforced-titanium (75 percent B-E and 25 percent Ti) design for application to the space shuttle booster thrust structure indicates that the latter would weigh approximately 24 percent less. Experimental data on the local buckling strength of cylinders with a diameter-thickness ratio of approximately 50 are needed to insure that undue conservatism is not used in future designs.

Corvelli, N.↗

Internal performance of a 10 deg conical plug nozzle with a multispoke primary and translating external shroud

An experimental investigation was conducted in a nozzle static test facility to determine the performance characteristics of a cold-flow, 21.59-centimeter-diameter plug nozzle with a multispoke primary. Two multispoke primary nozzles, a 12-spoke and a 24-spoke, were tested and compared with an annular plug nozzle. The supersonic cruise configurations for both spoke primaries performed about the same, with a gross thrust coefficient of 0.974, a decrease of approximately 1.5 percent from the reference nozzle. The takeoff configuration for the 12-spoke primary had a gross thrust coefficient of 0.957, a decrease of 1.5 percent from the reference nozzle, and the 24-spoke primary had a gross thrust coefficient of 0.95.

Bresnahan, D. L.↗

An experimental study of slot injection into a supersonic stream

An experimental investigation of two-dimensional tangential-slot injection into a turbulent boundary layer at a freestream Mach number of 2.4 has been conducted. Nearly adiabatic surface temperatures were maintained during all tests. Static and pitot pressure profiles at four stations downstream of the slot were obtained. Skin friction was measured at the last three stations with a self-nulling balance. Schlieren photographs of the flow field were also obtained. Most of the data were obtained with slot Mach numbers of 0.31 and 0.66 corresponding to slot pressure less than and equal to stream static pressure, respectively. For the latter matched-pressure case, tangential slot injection reduced the surface shear at the three measuring stations by about 60 to 20 percent for increasing downstream distances from the slot of 12 to 28 slot heights. However, for the other case where slot pressure was less than stream static pressure, the effect of injection was to increase the shear by about 90 percent at the last downstream station of 28 slot heights. This increase in shear is attributed to the rapid acceleration of the low speed injectant stream by the high speed main stream and the increasing pressure through the recompression zone which is absent for the matched pressure case.

Kenworthy, M.↗

Performance comparison of three normal-shock position sensors for mixed-compression inlets

The performance of three types of normal shock position sensors for supersonic inlets is described. All three sensors determined the shock position from the presence of the large pressure gradient at the normal shock location. The logic means for the three sensors were: (1) electronic, using pressure transducers, (2) fluidic, and (3) direct-coupled pressure switches. The sensors were evaluated in a two-dimensional, Mach 2.7, supersonic inlet having 30-percent internal supersonic area contraction. Both dynamic (from 1 to 80 Hz) and static tests were conducted.

Dustin, M. O.↗