Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “standard”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Fostering Geothermal Machine Learning Success: Elevating Big Data Accessibility and Automated Data Standardization in the Geothermal Data Repository: Preprint

The Department of Energy's (DOE) Geothermal Data Repository (GDR) has implemented improvements to both its data lakes and its data standards and automated data pipelines. The GDR data lakes have reduced storage and compute-related barriers to using large geothermal datasets, enabling these large datasets to be accessed by anyone with a modern computer and internet access. More recently, the GDR has been working to further reduce barriers through streamlining the data intake process, educating users on the process and requirements, and aiding users in accessing data from the data lakes. These improvements have augmented the quantity of datasets the GDR is able to accept into its data lakes and have enabled users who are new to cloud tools to access these datasets more easily, overall increasing the accessibility of big geothermal data for use in machine learning and other projects. In addition, the GDR now has built-in data standards and pipelines for drilling data, geospatial data, and distributed acoustic sensing (DAS) data. These standardization efforts aim to enhance the real-world applicability of geothermal machine learning outcomes by improving the quality of training data. Specifically, through standardizing high-value datasets, the GDR is reducing project-specific data curation requirements, thus allowing more time for actual research. By automating this process, the burden of standardization is lifted from the user, ultimately increasing the availability of standardized data.

accessibility↗

230Th-234U Model-Ages of Some Uranium Standard Reference Materials

The 'age' of a sample of uranium is an important aspect of a nuclear forensic investigation and of the attribution of the material to its source. To the extent that the sample obeys the standard rules of radiochronometry, then the production ages of even very recent material can be determined using the {sup 230}Th-{sup 234}U chronometer. These standard rules may be summarized as (a) the daughter/parent ratio at time=zero must be known, and (b) there has been no daughter/parent fractionation since production. For most samples of uranium, the 'ages' determined using this chronometer are semantically 'model-ages' because (a) some assumption of the initial {sup 230}Th content in the sample is required and (b) closed-system behavior is assumed. The uranium standard reference materials originally prepared and distributed by the former US National Bureau of Standards and now distributed by New Brunswick Laboratory as certified reference materials (NBS SRM = NBL CRM) are good candidates for samples where both rules are met. The U isotopic standards have known purification and production dates, and closed-system behavior in the solid form (U{sub 3}O{sub 8}) may be assumed with confidence. We present here {sup 230}Th-{sup 234}U model-ages for several of these standards, determined by isotope dilution mass spectrometry using a multicollector ICP-MS, and compare these ages with their known production history.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Beyond the Standard Model

'BSM physics' is a phrase used in several ways. It can refer to physical phenomena established experimentally but not accommodated by the Standard Model, in particular dark matter and neutrino oscillations (technically also anything that has to do with gravity, since gravity is not part of the Standard Model). 'Beyond the Standard Model' can also refer to possible deeper explanations of phenomena that are accommodated by the Standard Model but only with ad hoc parameterizations, such as Yukawa couplings and the strong CP angle. More generally, BSM can be taken to refer to any possible extension of the Standard Model, whether or not the extension solves any particular set of puzzles left unresolved in the SM. In this general sense one sees reference to the BSM 'theory space' of all possible SM extensions, this being a parameter space of coupling constants for new interactions, new charges or other quantum numbers, and parameters describing possible new degrees of freedom or new symmetries. Despite decades of model-building it seems unlikely that we have mapped out most of, or even the most interesting parts of, this theory space. Indeed we do not even know what is the dimensionality of this parameter space, or what fraction of it is already ruled out by experiment. Since Nature is only implementing at most one point in this BSM theory space (at least in our neighborhood of space and time), it might seem an impossible task to map back from a finite number of experimental discoveries and measurements to a unique BSM explanation. Fortunately for theorists the inevitable limitations of experiments themselves, in terms of resolutions, rates, and energy scales, means that in practice there are only a finite number of BSM model 'equivalence classes' competing at any given time to explain any given set of results. BSM phenomenology is a two-way street: not only do experimental results test or constrain BSM models, they also suggest - to those who get close enough to listen - new directions for BSM model building. Contrary to popular shorthand jargon, supersymmetry (SUSY) is not a BSM model: it is a symmetry principle characterizing a BSM framework with an infinite number of models. Indeed we do not even know the full dimensionality of the SUSY parameter space, since this presumably includes as-yet-unexplored SUSY-breaking mechanisms and combinations of SUSY with other BSM principles. The SUSY framework plays an important role in BSM physics partly because it includes examples of models that are 'complete' in the same sense as the Standard Model, i.e. in principle the model predicts consequences for any observable, from cosmology to b physics to precision electroweak data to LHC collisions. Complete models, in addition to being more explanatory and making connections between diverse phenomena, are also much more experimentally constrained than strawman scenarios that focus more narrowly. One sometimes hears: 'Anything that is discovered at the LHC will be called supersymmetry.' There is truth behind this joke in the sense that the SUSY framework incorporates a vast number of possible signatures accessible to TeV colliders. This is not to say that the SUSY framework is not testable, but we are warned that one should pay attention to other promising frameworks, and should be prepared to make experimental distinctions between them. Since there is no formal classification of BSM frameworks I have invented my own. At the highest level there are six parent frameworks: (1) Terascale supersymmetry; (2) PNGB Higgs; (3) New strong dynamics; (4) Warped extra dimensions; (5) Flat extra dimensions; and (6) Hidden valleys. Here is the briefest possible survey of each framework, with the basic idea, the generic new phenomena, and the energy regime over which the framework purports to make comprehensive predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Regional cancer centre demonstrates voluntary conformity with the national Radiation Oncology Practice Standards

Radiation Oncology Practice Standards have been developed over the last 10 years and were published for use in Australia in 2011. Although the majority of the radiation oncology community supports the implementation of the standards, there has been no mechanism for uniform assessment or governance. North Coast Cancer Institute's public radiation oncology service is provided across three main service centres on the north coast of NSW. With a strong focus on quality management, we embraced the opportunity to demonstrate conformity with the Radiation Oncology Practice Standards. The Local Health District's Clinical Governance units were engaged to perform assessments of our conformity with the standards and this was signed off as complete on 16 December 2013. The process of demonstrating conformity with the Radiation Oncology Practice Standards has enhanced the culture of quality in our centres. We have demonstrated that self-assessment utilising trained auditors is a viable method for centres to demonstrate conformity. National implementation of the Radiation Oncology Practice Standards will benefit individual centres and the broader radiation oncology community to improve the service delivered to our patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

Large-Volume Injection and Assessment of Reference Standards for n -Alkane δD and δ 13 C Analysis via Gas Chromatography Isotope Ratio Mass Spectrometry

Compound-specific stable isotope analysis of hydrogen (δD) and carbon (δ 13 C) in organic compounds is a valuable tool in biogeochemical research. A key limitation of this method is the relatively large amount of sample required to achieve desirable precision. We developed a large-volume (20 μL) injection method that allows for high throughput analysis of less concentrated samples and tested it for δ 13 C and δD measurements of n-alkanes. We also conducted a comparison of reference standards and assessed several methods to normalize and correct n-alkane δD and δ13C measurements. The mean precision of the δD method based on 233 environmental n-alkane samples (two to three replications per sample) is 4.0‰ (1σ, estimated from the weighted mean of the pooled unbiased standard deviations) and 0.46‰ (1σ) for δ 13 C from 37 environmental samples (two to three replications per sample). The evaluation of reference standards shows that the use of n-alkane standards with large offsets in δD values in adjacent n-alkane chains can lead to biases in measurement correction. The large-volume injection method shows good reproducibility of δ 13 C and δD measurements of n-alkanes and reduces the required sample concentration by about 80%. We propose that for δD measurements, a reference standard set should be used in which each reference standard has a limited range of δD values and no adjacent n-alkane chains, to minimize memory effects.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Importance of sample preparation on reliable surface characterisation of nano-objects: ISO Standard 20579-4

The international ISO Standard 20579-4, dealing with the history and preparation of nano-objects for surface analysis, has been developed to help address some of the replication and reproducibility issues caused by the fundamental nature of nano-objects. Although all types of samples requiring surface analysis need thoughtful preparation, nano-objects, for which many properties are controlled by their surfaces, present additional challenges in order to avoid variations and artefacts due to the handling and preparation of materials prior to analysis. This international standard is part of a series of standards related to preparation of samples for surface chemical analysis. Parts 1 and 2 of ISO Standard series 20579 address general issues that apply to many samples. Part 4 specifically considers issues that arise due to the inherent nature of nano-objects. Because of sensitivity to their environment, the standard indicates the minimum information that needs to be reported about the handling and preparation of nano-objects prior to surface analysis. This information should become part of sample provenance information that helps assure the reliability and usefulness of data obtained from surface-analysis in the context of the synthesis, processing and analysis history of a batch of material. Application of this standard can help address reproducibility and traceability issues associated with synthesis, processing, and characterization of nano-objects in research and commercial applications.

nano-object characterization, surface analysis, sa↗

Extracting meaningful standard enthalpies and entropies of activation for surface reactions from kinetic rates

While analyses based on the Arrhenius kinetic model have been successfully applied since its introduction, the Arrhenius model neglects to describe pre-exponential factor in a scientifically meaningful fashion. Since the 1930s, transition-state theory (TST), has met with success in interpreting the pre-exponential factor’s value, allowing a standard entropy of activation to be estimated. However, analyses based on TST’s assumptions have been applied inconsistently in the literature, particularly in corrosion science, leading to difficulty in comparison of standard entropy of activations from different studies. In this work, the foundational principles of TST and standard states are discussed and a standard method to apply TST in analyzing rates of surface reactions is recommended. When full details are not available, reacting species’ concentrations should be normalized to the concentration of active surface sites. For corrosion reactions, conversion relationships are given to convert from units of corrosion rate to surface reaction rate, consistent with TST. This method is dubbed a surface reactant equi-density approximation. Application of this standard to reported data results in adjustments of the standard entropy of activation between - 65 and +50 J/mol K and brings reported entropies into a narrower range of values.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses

Background: In cardiac SPECT perfusion imaging, respiratory motion can cause non-uniform blurring in the reconstructed myocardium. We investigate the potential benefit of respiratory correction with respiratory-binned acquisitions, both at standard dose and at reduced dose, for defect detection and for left ventricular (LV) wall resolution. Methods: We applied two reconstruction methods for respiratory motion correction: post-reconstruction motion correction (PMC) and motion-compensated reconstruction (MCR), and compared with reconstruction without motion correction (Non-MC). We quantified the presence of perfusion defects in reconstructed images by using the total perfusion deficit (TPD) scores and conducted receiver-operating-characteristic (ROC) studies using TPD. We quantified the LV spatial resolution by using the FWHM of its cross-sectional intensity profile. Results: The values in the area-under-the-ROC-curve (AUC) achieved by MCR, PMC, and Non-MC at standard dose were 0.835, 0.830, and 0.798, respectively. Similar AUC improvements were also obtained by MCR and PMC over Non-MC at 50%, 25%, and 12.5% of full dose. Improvements in LV resolution were also observed with motion correction. Conclusions: Respiratory-binned acquisitions can improve perfusion-defect detection accuracy over traditional reconstruction both at standard dose and at reduced dose. Motion correction may contribute to achieving further dose reduction while maintaining the diagnostic accuracy of traditional acquisitions. [French] French Abstract: Contexte: Les mouvements respiratoires peuvent entrainer des artefacts de uniformité lors de la reconstruction des images de perfusion myocardique en SPECT. Dans cet article, nous rapportons nos résultats sur le bénéfice potentiel du « gating » respiratoire avec des doses standards et réduites de radio-pharmaceutiques pour la détection des anomalies de perfusion et les mesures de la paroi ventriculaire gauche. Méthodes: Nous avons appliqué deux méthodes de reconstruction pour la correction du mouvement respiratoire: la première fait appel a une correction après reconstruction des images (PMC) ; la seconde fait appel à la correction des images avant reconstruction (MRC). Les deux approches ont été comparées à la reconstruction sans correction de mouvement (Non-MC). Nous avons quantifié les déficits de perfusion myocardiques sur les images reconstruites avec le système des scores de déficit de perfusion et analysé les résultats en utilisant les courbes ROC. Nous avons quantifié la résolution spatiale du VG en utilisant le FWHM du profil d’intensité de sa section transversale. Résultats: Les valeurs des surfaces en dessous des courbes ROC (AUC) obtenues par MCR, PMC et Non-MC avec doses standard de radio-pharmaceutiques étaient de 0,835, 0,830 et 0,798, respectivement. Des améliorations similaires de l’AUC ont également été obtenues par MCR et PMC sur Non-MC avec 50%, 25% et 12,5% des doses entières. Les mesures de résolution spatiale de la paroi du VG ont également été améliorées avec la correction des mouvements respiratoires. Conclusions: La correction des images de perfusion myocardiques en SPECT par « gating » respiratoire paraît améliorer la quantification des déficits perfusionels à la fois à dose standard et à dose réduite de radio-pharmaceutiques. L’application de cette correction devrait permettre de réduire les doses de radio-pharmaceutiques utilisées tout en maintenant la précision diagnostique des acquisitions traditionnelles. [Spanish] Spanish Abstract: Antecedentes: En los estudios de perfusión cardiaca por SPECT, los movimientos respiratorios pueden causar distorsión no uniforme en el miocardio reconstruido. Investigamos el beneficio potencial de la corrección respiratoria con adquisición de imágenes sincronizadas con la respiración, tanto a dosis estándar como a dosis reducida, para detección de defectos y para resolución de pared de ventrículo izquierdo (VI). Métodos: Aplicamos dos métodos de reconstrucción para corrección de movimientos respiratorios: Corrección de movimiento post reconstrucción (PMC) y reconstrucción compensada a movimiento (MCR), y los comparamos con la reconstrucción sin corrección de movimiento (Non-MC). Cuantificamos la presencia de defectos de perfusión en las imágenes reconstruidas usando los scores de déficit total de perfusión (TPD) y análisis ROC usando el TPD. Cuantificamos la resolución espacial del VI usando la anchura a media altura de su perfil de intensidad transversal. Resultados: Los valores en el área bajo la curva ROC (ABC) obtenidos por MCR, PMC y Non-MC a dosis estándar fueron 0.835, 0.830 y 0.798, respectivamente. Mejorías similares del ABC también se obtuvieron por MCR y PMC, sobre Non-MC a 50%, 25% y 12.5% de la dosis completa. Las mejorías en la resolución del VI fueron observadas también con corrección del movimiento. Conclusiones: Las adquisiciones sincronizadas con la respiración pueden mejorar la precisión de la detección de defectos de perfusión sobre las reconstrucciones tradicionales tanto a dosis estándar como a dosis reducida. La corrección de movimiento puede contribuir a lograr mayor reducción de la dosis manteniendo la precisión diagnóstica de las adquisiciones tradicionales. [Chinese] Chinese Abstract: 背景: 在心脏 SPECT 灌注成像中, 呼吸运动会导致心肌重建的不均匀模糊。我们研究了无论是标准剂量还是减少剂量的情况下, 呼吸跟踪采集的呼吸校正用于图像缺损检测和左心室 (LV) 室壁分辨率的潜在益处。 方法: 我们使用了两种呼吸运动校正的重建方法:重建后运动校正 (PMC) 和运动补偿重建 (MCR), 并与没有运动校正的重建 (Non-MC) 进行比较。 通过总灌注缺损 (TPD) 评分和其接受者操作特性曲线 (ROC) 来量化重建图像中的灌注缺陷。通过LV横截面强度分布的 FWHM来量化 LV 空间分辨率。 结果: MCR, PMC 和 Non-MC 在标准剂量下所获得的 ROC 曲线下面积 (AUC) 的值分别为0.835, 0.830 和 0.798。 在全剂量下, MCR, PMC和 Non-MC也获得类似的 AUC 提高, 分别为 50%, 25% 和 12.5%。 在运动校正下, LV的分辨率也得到了改善。 结论: 在标准剂量和减少剂量的情况下, 呼吸跟踪采集可以改善灌注缺损检测的准确性。 运动校正可能有助于进一步实现减少剂量的目标, 同时保证通过传统检测方法的诊断准确性。.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Breast Sentinel Lymph Node Coverage by Standard Radiation Therapy Fields

Background: Biopsy of the breast sentinel lymph node (SLN) is now a standard staging procedure for early-stage invasive breast cancer. The anatomic location of the breast SLN and its relationship to standard radiation fields has not been described. Methods and Materials: A retrospective review of radiotherapy treatment planning data sets was performed in patients with breast cancer who had undergone SLN biopsy, and those with a surgical clip at the SLN biopsy site were identified. The location of the clip was evaluated relative to vertebral body level on an anterior-posterior digitally reconstructed radiograph, treated whole-breast tangential radiation fields, and standard axillary fields in 106 data sets meeting these criteria. Results: The breast SLN varied in vertebral body level position, ranging from T2 to T7 but most commonly opposite T4. The SLN clip was located below the base of the clavicle in 90%, and hence would be excluded from standard axillary radiotherapy fields where the inferior border is placed at this level. The clip was within the irradiated whole-breast tangent fields in 78%, beneath the superior-posterior corner multileaf collimators in 12%, and outside the tangent field borders in 10%. Conclusions: Standard axillary fields do not encompass the lymph nodes at highest risk of containing tumor in breast cancer patients. Elimination of the superior-posterior corner MLCs from the tangent field design would result in inclusion of the breast SLN in 90% of patients treated with standard whole-breast irradiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Exploring the working range of automated standard dilution analysis of nutrient elements in foods by inductively coupled plasma optical emission spectrometry

Inductively coupled plasma optical emission spectrometry (ICP-OES) is an important tool for measuring nutrient elements in food. ICP-OES methods typically determine analytical concentrations using external standard calibration but can be susceptible to matrix effects. The method of standard additions does not suffer from matrix effects but is time consuming and labor intensive. Automated standard dilution analysis (SDA) allows for online matrix matched calibration without preparing individual standard additions for each sample matrix. This approach may solve both time and matrix issues and has been described in the literature as an attractive alternative to standard additions. The working range of the method for nutrient elements, however, is an understudied feature of SDA that may be a potential drawback to routine analysis of foods. We evaluated automated SDA performance through the analysis of 10 reference materials and four fortified (i.e., spiked) foods spanning the AOAC food triangle. We evaluated the working range, accuracy, and precision for analyses of nutrient elements in foods. Accepted accuracy (80–120% recovery) was achieved for 10 nutrient elements, Ca, Cu, Fe, K, Mg, Mn, Na, P, S, and Zn, when the analytical solution concentration to standard concentration ratio was less than 10. This equates to a working range for each element spanning at least two orders of magnitude. Removing outliers, Z scores (n = 95) ranged from –1.8 to 0.88, and the average recovery (n = 85) from fortification experiments was 97 ± 12% (2σ). Therefore, automated SDA applied to ICP-OES may be used for nutrient elemental analyses in samples with difficult matrices such as foods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

FIRST-YEAR SLOAN DIGITAL SKY SURVEY-II (SDSS-II) SUPERNOVA RESULTS: CONSTRAINTS ON NONSTANDARD COSMOLOGICAL MODELS

We use the new Type Ia supernovae discovered by the Sloan Digital Sky Survey-II supernova survey, together with additional supernova data sets as well as observations of the cosmic microwave background and baryon acoustic oscillations to constrain cosmological models. This complements the standard cosmology analysis presented by Kessler et al. in that we discuss and rank a number of the most popular nonstandard cosmology scenarios. When this combined data set is analyzed using the MLCS2k2 light-curve fitter, we find that more exotic models for cosmic acceleration provide a better fit to the data than the LAMBDACDM model. For example, the flat Dvali-Gabadadze-Porrati model is ranked higher by our information-criteria (IC) tests than the standard model with a flat universe and a cosmological constant. When the supernova data set is instead analyzed using the SALT-II light-curve fitter, the standard cosmological-constant model fares best. This investigation of how sensitive cosmological model selection is to assumptions about, and within, the light-curve fitters thereby highlights the need for an improved understanding of these unresolved systematic effects. Our investigation also includes inhomogeneous LemaItre-Tolman-Bondi (LTB) models. While our LTB models can be made to fit the supernova data as well as any other model, the extra parameters they require are not supported by our IC analysis. Finally, we explore more model-independent ways to investigate the cosmic expansion based on this new data set.

79 ASTRONOMY AND ASTROPHYSICS↗

DICHOTOMY OF SOLAR CORONAL JETS: STANDARD JETS AND BLOWOUT JETS

By examining many X-ray jets in Hinode/X-Ray Telescope coronal X-ray movies of the polar coronal holes, we found that there is a dichotomy of polar X-ray jets. About two thirds fit the standard reconnection picture for coronal jets, and about one third are another type. We present observations indicating that the non-standard jets are counterparts of erupting-loop H{alpha} macrospicules, jets in which the jet-base magnetic arch undergoes a miniature version of the blowout eruptions that produce major coronal mass ejections. From the coronal X-ray movies we present in detail two typical standard X-ray jets and two typical blowout X-ray jets that were also caught in He II 304 A snapshots from STEREO/EUVI. The distinguishing features of blowout X-ray jets are (1) X-ray brightening inside the base arch in addition to the outside bright point that standard jets have, (2) blowout eruption of the base arch's core field, often carrying a filament of cool (T {approx} 10{sup 4} - 10{sup 5} K) plasma, and (3) an extra jet-spire strand rooted close to the bright point. We present cartoons showing how reconnection during blowout eruption of the base arch could produce the observed features of blowout X-ray jets. We infer that (1) the standard-jet/blowout-jet dichotomy of coronal jets results from the dichotomy of base arches that do not have and base arches that do have enough shear and twist to erupt open, and (2) there is a large class of spicules that are standard jets and a comparably large class of spicules that are blowout jets.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-582: Evaluation of Standard Beam Delivery Devices in Proton Intracranial Radiosurgery

Purpose: To evaluate the use of standard apertures and range shifters for the treatment of brain metastasis in proton stereotactic radiosurgery. Methods: Five localized brain metastasis patients previously treated using our intracranial proton stereotactic radiosurgery procedure (i.e. with a custom aperture and bolus), were randomly selected from our patient cohort. The custom aperture and bolus treatment plans were used as the standard of care in this case and comparative treatment plans using the standard aperture and range shifter concept were generated. Gantry/table angle and the number of treatment beams were optimized as part of this study to evaluate the ability of the standard aperture/range shifter system to deliver a comparable treatment to the patient. Conformity index, homogeneity index, isodose volumes and integral dose were all evaluated to determine the degree of conformity of the plans created and for comparison to the custom aperture/bolus treatment modality. Results: The generated treatment plans demonstrated that the standard aperture and range shifter combination could be used to produce comparable conformity index and isodose volumes to the custom aperture/bolus case in four out of the five patients studied. In two of the patients a comparative conformity index was achieved by optimizing the angles of the 3 treatment beams, while in two of the cases 1 or 2 additional beams were required. Additionally, this system exhibited efficiency gains of 60-90% over the custom aperture bolus system in reducing the time necessary for treatment planning, device manufacture and QA. Conclusion: This work demonstrated that largely spherical shape of brain metastasis makes this target well suited to an application of standard apertures, while additionally providing efficiency gains in device manufacture and QA for treatment.

60 APPLIED LIFE SCIENCES↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Leveraging the Higgs to Discover Physics Beyond the Standard Model (Final Technical Report)

The discovery of an apparently Standard Model-like Higgs at the Large Hadron Collider (LHC) heralds the start of a new era in particle physics. While the Higgs marks the completion of the Standard Model framework, it offers far more opportunities in the search for physics beyond the Standard Model. The Higgs boson raises a pressing theoretical problem known as the hierarchy problem: why is an elementary scalar particle so light when quantum corrections tie its mass to the highest energy scales? The Higgs also provides an unprecedented experimental opportunity as a bellwether of new physics: it may be merely the first of several states in the electroweak symmetry breaking sector, while its production and decays may provide unique evidence for additional particles. Research supported by this award leveraged the Higgs boson to explore new physics from both directions, developing novel approaches to solving the hierarchy problem posed by the Higgs boson and directly employing the Higgs as a new tool for discovery. Given that null results at the LHC and other experiments have begun to endanger conventional approaches to the hierarchy problem, research supported by the award identified original solutions to the hierarchy problem wherein the lightest degrees of freedom protecting the Higgs boson carry no Standard Model quantum numbers and thus evade existing searches. The PI's approach combined standard tools of quantum field theory with novel applications of the orbifold reduction of continuous symmetries to define the framework of "neutral naturalness'' and explore its experimental consequences across the energy, intensity, and cosmic frontiers. In employing the Higgs directly as a tool for discovery, research supported by this award articulated a systematic approach to searching for extensions of the Higgs sector at the LHC and pursued four key avenues through which the Higgs can be used to uncover new physics across a range of experiments: (1) as a direct final state probe; (2) as an indirect probe through its couplings; (3) as a portal to states neutral under the Standard Model; and (4) as a source of exotic processes in displaced decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Achieving the 30% Goal: Energy and Cost Savings Analysis of ASHRAE Standard 90.1-2010

This report documents the progress indicator (PI) process and analysis that Pacific Northwest National Laboratory (PNNL) developed to evaluate the potential energy savings from the application of ASHRAE Standard 90.1-2010 to building design and construction compared to the application of ASHRAE Standard 90.1-2004. The report describes PNNL’s EnergyPlus simulation framework, and the building prototype simulation models. The combined upgrades from ASHRAE Standard 90.1 -2004 to ASHRAE Standard 90.1-2010 are described, and consist of a total of 153 approved addenda (44 addenda to ASHRAE Standard 90.1-2007 and 109 addenda to ASHRAE Standard 90.1-2010). PNNL reviewed and considered all 153 addenda for quantitative analysis in the PI process. Fifty-three of those addenda are included in the quantitative analysis. This report provides information on the categorization of all of the addenda, a summary of the content, and a more in-depth explanation of the impact and modeling of the 53 identified addenda and their quantitative savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ANSI/ASHRAE/IESNA Standard 90.1-2007 Final Determination Quantitative Analysis

DOE conducted a final quantitative analysis to assess whether buildings constructed according to the requirements of the ASHRAE Standard 90.1-2007 would result in energy savings compared with buildings constructed to ASHRAE Standard 90.1-2004. The final analysis considered each of the 44 addenda to ASHRAE Standard 90.1-2004 that were included in ASHRAE Standard 90.1-2007. All 44 addenda processed by ASHRAE in the creation of Standard 90.1-2007 from ASHRAE Standard 90.1-2004 were reviewed by DOE, and their combined impact on a suite of 15 building prototype models in 15 ASHRAE climate zones was considered. Most addenda were deemed to have little quantifiable impact on building efficiency for the purpose of DOE’s final determination. However, out of the 44 addenda, 9 were preliminarily determined to have measurable and quantifiable impact.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Photofission Validation Measurements for Active Interrogation Standards

Executive Summary PNNL has been developing technical standards for the detection of special nuclear material (SNM) in cargo containers using active interrogation approaches. Since the use of kilogram-scale quantities of SNM is impractical for standards testing, the work focused on designing surrogates that provided similar signature as the SNM. There are many active interrogation approaches to detect SNM; the standards development considered photofission, differential die-away and nuclear resonance fluorescence. Of these approaches, photofission currently carries the most interest. However, uncertainties in the photofission cross sections are as large as 50%, so that validation measurements are necessary to provide confidence that the surrogate will perform similarly to the SNM. This document describes approaches for conducting those validation measurements as well as provides a rough order-of-magnitude cost estimate for performing them. Photofission provides many observables for the detection of SNM. The standards development considered prompt neutrons, delayed neutrons and delayed gamma rays as possible detected particles. The surrogates, which consist primarily of depleted uranium (DU), were designed to reproduce the strength of these particles for a targeted quantity of 2 kg of HEU. Different surrogates are required for different measurement approaches because of the difference in cross section between 235 U and 238 U. For the standards validations, the relative strength of the detected particles for HEU and DU must be measured. To avoid measurements with kilogram-sized SNM, the validation approach is focused on two comparisons. In the first comparison, the relative rates for approximately 10 g samples of DU and HEU will be measured. This comparison will provide the basis for validating the relative strength of the detected particles for HEU and DU. In the second comparison, the relative rates for the approximately 10 g and 1 kg sample of DU will be measured. This comparison will enable the validation of secondary processes that occur after photofission that impact the measurement for kilogram-scale samples. For instance, for 2 kg of HEU, as much as 50% of the fission induced in the sample is induced from fission neutrons generated through photofission. There is a limited range of facilities in the U.S. that have both the necessary accelerator capability and the ability and willingness to handle SNM. Two such facilities, the Idaho Accelerator Center at Idaho State University and the Nuclear Engineering Program at the University of Michigan, have both expressed an interest in participating in such measurements. Both would need to amend their licensing to handle the 10 g of HEU proposed for these measurements. The rough order-of-magnitude cost estimate for all three validation measurements is $1.1M, spread over three years. Each of the three measurements could be performed separately, at approximately one-third of that cost. There are a number of critical assumptions in these cost estimate that will need to be confirmed before a more reliable cost estimate can be established. PNNL will manage the effort to ensure that the overall objective of the validation measurements can be achieved and will fabricate the 10 g samples of HEU and DU. Most the labor for the measurements will be provided by two collaborating universities as research opportunities for students. The successful completion of these validation measurements will reduce the uncertainties in the proposed standards from about 50% to 5%. The measurements would also provide some much-needed nuclear data on photofission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗