Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “spatial”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Calculation of spatial distribution of optical escape factor and its application to He I collisional-radiative model

An integral analytical formula for a spatial distribution of the optical escape factor (OEF) in an infinite cylindrical plasma is derived as a function of an arbitrary upper state spatial density profile, the temperature ratio of the upper state to the lower state, and the optical depth of the corresponding transition. Test calculations are carried out for three different upper state profiles, i.e., uniform (rectangular), parabolic, and Gaussian upper state profiles. The OEF takes on negative values at the periphery of the parabolic and Gaussian upper state profiles. These characteristics cannot be expressed by the conventional OEF formulas derived for the center of the plasma, even though the optical depth is increased. In addition to the analytical derivation of the formula, two practical formulas are proposed: an empirical formula of the spatial distribution of the OEF for the Gaussian upper state density profile and a linear formula of the OEF distribution for upper state profiles that are expressed as linear combinations. These formulas enable us to calculate the spatial distribution of the OEF for the multiple-Gaussian upper state profile without the need for time-consuming integral calculations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

New Lens-Free X-ray Source for Laboratory Nano-CT with 50-nm Spatial Resolution

X-ray optics, such as zone plates, are often used to obtain a spatial resolution better than 100 nm in x-ray projection images. Such types of optics are not always suited for tomographic imaging due to their limited depth of focus, which restricts the size of the specimen to a few microns. To overcome these limitations, we developed a new lens-free setup for a nano-CT system. Spatial resolution of nano-CT systems is mainly defined by x-ray source performance. It is dependent on target shape and focusing of the electron beam. The typical way to improve spatial resolution is based on replacement of the bulk metal target to thin film. It allows getting submicron spot size, but significantly reduces x-ray flux. To overcome flux limitation without compromising with spatial resolution, we invented a new type of target shaped as a rod or needle towards the camera. It allows us to reach 50-nm resolution with reasonable flux.

07 ISOTOPE AND RADIATION SOURCES↗

Computer simulation on spatial resolution of X-ray bright-field imaging by dynamical diffraction theory for a Laue-case crystal analyzer

Recently, dark-field imaging (DFI) and bright-field imaging (BFI) have been proposed and applied to visualize X-ray refraction effects yielded in biomedical objects. In order to clarify the spatial resolution due to a crystal analyzer in Laue geometry, a program based on the Takagi-Taupin equation was modified to be used for carrying out simulations to evaluate the spatial resolution of images coming into a Laue angular analyzer (LAA). The calculation was done with a perfect plane wave for diffraction wave-fields, which corresponded to BFI, under the conditions of 35 keV and a diffraction index 440 for a 2100 {mu}m thick LAA. As a result, the spatial resolution along the g-vector direction showed approximately 37.5 {mu}m. 126 {mu}m-thick LAA showed a spatial resolution better than 3.1 {mu}m under the conditions of 13.7 keV and a diffraction index 220.

36 MATERIALS SCIENCE↗

Influence of excited state spatial distributions on plasma diagnostics: Atmospheric pressure laser-induced He-H{sub 2} plasma

Atmospheric pressure plasmas in helium-hydrogen mixtures with H{sub 2} molar concentrations ranging from 0.13% to 19.7% were investigated at times from 1 to 25 {mu}s after formation by a Q-switched Nd:YAG laser. Spatially integrated electron density values are obtained using time resolved optical emission spectroscopic techniques. Depending on mixture concentration and delay time, electron densities vary from almost 10{sup 17} cm{sup -3} to about 10{sup 14} cm{sup -3}. Helium based results agree reasonably well with each other, as do values extracted from the H{sub {alpha}} and H{sub {beta}} emission lines. However, in particular for delays up to about 7 {mu}s and in mixtures with less than 1% hydrogen, large discrepancies are observed between results obtained from the two species. Differences decrease with increasing hydrogen partial pressure and/or increasing delay time. In mixtures with molecular hydrogen fraction of 7% or more, all methods yield electron densities that are in good agreement. These findings seemingly contradict the well-established idea that addition of small amounts of hydrogen for diagnostic purposes does not perturb the plasma. Using Abel inversion analysis of the experimental data and a semi-empirical numerical model, we demonstrate that the major part of the detected discrepancies can be traced to differences in the spatial distributions of excited helium and hydrogen neutrals. The model yields spatially resolved emission intensities and electron density profiles that are in qualitative agreement with experiment. For the test case of a 1% H{sub 2} mixture at 5 {mu}s delay, our model suggests that high electron temperatures cause an elevated degree of ionization and thus a reduction of excited hydrogen concentration relative to that of helium near the plasma center. As a result, spatially integrated analysis of hydrogen emission lines leads to oversampling of the plasma perimeter and thus to lower electron density values compared to those obtained from helium lines.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spatial resolution of synchrotron x-ray microtomography in high energy range: Effect of x-ray energy and sample-to-detector distance

Spatial resolution of three-dimensional images obtained by synchrotron X-ray microtomography technique is evaluated using cyclic bar patterns machined on a steel wire. Influences of X-ray energy and the sample-to-detector distance on spatial resolution were investigated. High X-ray energies of 33-78 keV are applied due to the high X-ray absorption of transition metals. Best spatial resolution of about 1.2 {mu}m pitch was observed at the sample-to-detector distance range of 20-110 mm and at the energy range of 68-78 keV. Several factors such as X-ray scattering and diffraction phenomena affecting the degradation of spatial resolution are also discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Towards POI-based large-scale land use modeling: spatial scale, semantic granularity, and geographic context

The combination of spatial distribution, semantic characteristics, and sometimes temporal dynamics of POIs inside a geographic region can capture its unique land use characteristics. Most previous studies on POI-based land use modeling research focused on one geographic region and select one spatial scale and semantic granularity for land use characterization. There is a lack of understanding on the impact of spatial scale, semantic granularity, and geographic context on POI-based land use modeling, particularly large-scale land use modeling. In this study, we developed a scalable POI-based land use modeling framework and examined the impact of these three factors on POI-based land use characterization using data from three geographic regions. We developed a unified semantic representation framework for POI semantics that can help fuse heterogeneous POI data sources. Then, by combining POIs with a neural network language model, we developed a spatially explicit approach to learn the embedding representation of POIs and AOIs. We trained multiple supervised classifiers using AOI embeddings as input features to predict AOI land use at different semantic granularities. The classification performance of different land use classes was analyzed and compared across three geographic regions to identify the semantic representativeness of POI-based AOI embedding and the impact of geographic context.

58 GEOSCIENCES↗

A HIGH SPATIAL RESOLUTION MID-INFRARED SPECTROSCOPIC STUDY OF THE NUCLEI AND STAR-FORMING REGIONS IN LUMINOUS INFRARED GALAXIES

We present a high spatial (diffraction-limited) resolution ({approx}0.''3) mid-infrared (MIR) spectroscopic study of the nuclei and star-forming regions of four local luminous infrared galaxies (LIRGs) using T-ReCS on the Gemini South telescope. We investigate the spatial variations of the features seen in the N-band spectra of LIRGs on scales of {approx}100 pc, which allow us to resolve their nuclear regions and separate the active galactic nucleus (AGN) emission from that of the star formation (SF). We compare (qualitatively and quantitatively) our Gemini T-ReCS nuclear and integrated spectra of LIRGs with those obtained with Spitzer IRS. Star-forming regions and AGNs show distinct features in the MIR spectra, and we spatially separate these, which is not possible using the Spitzer data. The 9.7 {mu}m silicate absorption feature is weaker in the nuclei of the LIRGs than in the surrounding regions. This is probably due to the either clumpy or compact environment of the central AGN or young, nuclear starburst. We find that the [Ne II]12.81 {mu}m luminosity surface density is tightly and directly correlated with that of Paalpha for the LIRG star-forming regions (slope of 1.00 +- 0.02). Although the 11.3 {mu}m PAH feature shows also a trend with Paalpha, this is not common for all the regions and the slope is significantly lower. We also find that the [Ne II]12.81 {mu}m/Paalpha ratio does not depend on the Paalpha equivalent width (EW), i.e., on the age of the ionizing stellar populations, suggesting that, on the scales probed here, the [Ne II]12.81 {mu}m emission line is a good tracer of the SF activity in LIRGs. On the other hand, the 11.3 {mu}m PAH/Paalpha ratio increases for smaller values of the Paalpha EW (increasing ages), indicating that the 11.3 {mu}m PAH feature can also be excited by older stars than those responsible for the Paalpha emission. Finally, more data are needed in order to address the different physical processes (age of the stellar populations, hardness and intensity of the radiation field, mass of the star-forming regions) affecting the energetics of the polycyclic aromatic hydrocarbon features in a statistical way. Additional high spatial resolution observations are essential to investigating the SF in local LIRGs at the smallest scales and determining ultimately whether they share the same physical properties as high-z LIRGs, ULIRGs, and submillimiter galaxies and therefore belong to the same galaxy population.

79 ASTRONOMY AND ASTROPHYSICS↗

THE NATURE OF STARBURSTS. III. THE SPATIAL DISTRIBUTION OF STAR FORMATION

We map the spatial distribution of recent star formation over a few Multiplication-Sign 100 Myr timescales in 15 starburst dwarf galaxies using the location of young blue helium burning stars identified from optically resolved stellar populations in archival Hubble Space Telescope observations. By comparing the star formation histories from both the high surface brightness central regions and the diffuse outer regions, we measure the degree to which the star formation has been centrally concentrated during the galaxies' starbursts, using three different metrics for the spatial concentration. We find that the galaxies span a full range in spatial concentration, from highly centralized to broadly distributed star formation. Since most starbursts have historically been identified by relatively short timescale star formation tracers (e.g., H{alpha} emission), there could be a strong bias toward classifying only those galaxies with recent, centralized star formation as starbursts, while missing starbursts that are spatially distributed.

79 ASTRONOMY AND ASTROPHYSICS↗

DIFFUSION OF SOLAR MAGNETIC ELEMENTS UP TO SUPERGRANULAR SPATIAL AND TEMPORAL SCALES

The study of spatial and temporal scales on which small magnetic structures (magnetic elements) are organized in the quiet Sun may be approached by determining how they are transported on the solar photosphere by convective motions. The process involved is diffusion. Taking advantage of Hinode high spatial resolution magnetograms of a quiet-Sun region at the disk center, we tracked 20,145 magnetic elements. The large field of view ({approx}50 Mm) and the long duration of the observations (over 25 hr without interruption at a cadence of 90 s) allowed us to investigate the turbulent flows at unprecedented large spatial and temporal scales. In the field of view an entire supergranule is clearly recognizable. The magnetic element displacement spectrum shows a double-regime behavior: superdiffusive ({gamma} = 1.34 {+-} 0.02) up to granular spatial scales ({approx}1500 km) and slightly superdiffusive ({gamma} = 1.20 {+-} 0.05) up to supergranular scales.

79 ASTRONOMY AND ASTROPHYSICS↗

Quantum dynamics of spatial decoherence of two atoms in a ring cavity

We study the spatial decoherence dynamics for the relative position of two atoms in a single-mode ring cavity. We find that the spatial decoherence of the two atoms depends strongly on their relative position. Taking into account the spatial degrees of freedom, we investigate the entanglement dynamics of the internal states of the two atoms. It is shown that the entanglement decays to almost zero in a finite time, and the disentanglement time depends on the width of the wave packets describing the atomic spatial distribution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Ce-Doped LiI Scintillator Film-Based High Rate, High Spatial Resolution Neutron Anger Camera for Neutron Scattering Facilities

The 2-D position sensitive neutron detectors featuring a significantly improved count rate capacity and a sub-mm spatial resolution are in high demand by neutron scattering facilities, especially the next generation high-flux spallation neutron sources (SNSs). They are anticipated to play a crucial role in fully utilizing the unprecedentedly high neutron brightness offered by these sources. In this work, a high rate and high spatial resolution neutron Anger camera has been successfully developed based on a Ce-doped microcolumnar LiI scintillator film and the PETsys TOFPET2 ASIC readout electronics. The performance evaluation was conducted in a standard laboratory environment as well as the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL) with regard to light yield, γ-ray sensitivity, neutron detection efficiency, count rate capability, spatial resolution, and position linearity. The LiI:Ce scintillator was found to have a higher light yield and a lower γ-ray sensitivity than GS20 (i.e., 11729 versus 6000 photons/n and 1.67 × 10 −5 versus on the order of 10 −4 ). The neutron detection efficiency was measured to be 63% at 4.2 Å. This camera demonstrated an exceptional count rate capability, up to at least 481 kHz without rate loss. The spatial resolution was as good as 0.47 mm. Here, the position linearity was also enhanced.

High rate↗

Evaluating Spatial Accelerator Architectures with Tiled Matrix-Matrix Multiplication.

There is a growing interest in custom spatial accelerators for machine learning applications. These accelerators employ a spatial array of processing elements (PEs) interacting via custom buffer hierarchies and networks-on-chip. The efficiency of these accelerators comes from employing optimized dataflow (i.e., spatial/temporal partitioning of data across the PEs and fine-grained scheduling) strategies to optimize data reuse. The focus of this work is to evaluate these accelerator architectures using a tiled general matrix-matrix multiplication (GEMM) kernel. To do so, we develop a framework that finds optimized mappings (dataflow and tile sizes) for a tiled GEMM for a given spatial accelerator and workload combination, leveraging an analytical cost model for runtime and energy. Finally, our evaluations over five spatial accelerators demonstrate that the tiled GEMM mappings systematically generated by our framework achieve high performance on various GEMM workloads and accelerators.

42 ENGINEERING↗

Crowd-based spatial risk assessment of urban flooding: Results from a municipal flood hotline in Detroit, MI

Climate change is increasing the frequency and intensity of extreme precipitation events, raising the risk of urban flood disasters. This study uses a crowd-sourced municipal call database to characterize the spatial distribution of flood risk in Detroit, MI. Call data including dates and addresses were obtained from the City of Detroit Department of Public Works for 2021. Calls were mapped and aggregated to census tract counts and merged with neighborhood-level data. Associations of predictors with flood calls were tested using spatial regression models. Flooding calls were located throughout the city but were concentrated in specific areas. Multivariate models of census tract level call counts indicated that increased poverty and Black, immigrant, and older residents were positively associated with flood calls, while increased elevation was associated with protective effects. Longer distances from waste water interceptors were associated with higher risk for calls. Crowd-sourced flood hotline call data can be used for effective spatial flood risk assessment. Though flooding occurs throughout the city of Detroit, infrastructural, neighborhood, and household factors influence flooding extent. Limitations included the self-reported nature of calls. Future modeling efforts might include input from local stakeholders to improve spatial risk assessment.

54 ENVIRONMENTAL SCIENCES↗

The DOSIMAP, a high spatial resolution tissue equivalent 2D dosimeter for LINAC QA and IMRT verification

The continual need for more accurate and effective techniques in radiation therapy makes it necessary to devise new control means combining high spatial resolution as well as high dose accuracy. Intensity modulated radio therapy (IMRT) allows highly conformed fields with high spatial gradient and therefore requires a precise monitoring of all the multileaf positions. In response to this need, the authors have developed a new 2D tissue equivalent dosimeter with high spatial resolution. A plastic scintillator sheet is sandwiched between two polystyrene blocks and the emitted light is captured by a high resolution camera. A newly developed procedure described herein allows efficient discrimination of the scintillation from the parasitic Cerenkov radiation. This processing is applied on the cumulated image from a sequence of images taken during an irradiation field at a rate of 10 images/s. It provides a high resolution mapping of the cumulated dose in quasireal time. The dosimeter is tissue equivalent (ICRU-44) and works both for electrons and photons without complex parameter adjustment since phantom and detector materials are identical. Instrument calibration is simple and independent of the irradiation conditions (energy, fluence, quality, ...). In this article, the authors present the principle of the dosimeter and its calibration procedure. They compare the results obtained for photons and electron beams with ionization chamber measurements in polystyrene. Technical specifications such as accuracy and repeatability are precisely evaluated and discussed. Finally, they present different IMRT field measurements and compare DOSIMAP measurements to TPS simulations and dosimetric film profiles. The results confirm the excellent spatial resolution of the instrument and its capacity to inspect the leaf positions for each segment of a given field.

61 RADIATION PROTECTION AND DOSIMETRY↗

Scaling law for noise variance and spatial resolution in differential phase contrast computed tomography

Purpose: The noise variance versus spatial resolution relationship in differential phase contrast (DPC) projection imaging and computed tomography (CT) are derived and compared to conventional absorption-based x-ray projection imaging and CT. Methods: The scaling law for DPC-CT is theoretically derived and subsequently validated with phantom results from an experimental Talbot-Lau interferometer system. Results: For the DPC imaging method, the noise variance in the differential projection images follows the same inverse-square law with spatial resolution as in conventional absorption-based x-ray imaging projections. However, both in theory and experimental results, in DPC-CT the noise variance scales with spatial resolution following an inverse linear relationship with fixed slice thickness. Conclusions: The scaling law in DPC-CT implies a lesser noise, and therefore dose, penalty for moving to higher spatial resolutions when compared to conventional absorption-based CT in order to maintain the same contrast-to-noise ratio.

60 APPLIED LIFE SCIENCES↗

Multicriteria optimization of the spatial dose distribution

Purpose: Treatment planning for radiation therapy involves trade-offs with respect to different clinical goals. Typically, the dose distribution is evaluated based on few statistics and dose–volume histograms. Particularly for stereotactic treatments, the spatial dose distribution represents further criteria, e.g., when considering the gradient between subregions of volumes of interest. The authors have studied how to consider the spatial dose distribution using a multicriteria optimization approach.Methods: The authors have extended a stepwise multicriteria optimization approach to include criteria with respect to the local dose distribution. Based on a three-dimensional visualization of the dose the authors use a software tool allowing interaction with the dose distribution to map objectives with respect to its shape to a constrained optimization problem. Similarly, conflicting criteria are highlighted and the planner decides if and where to relax the shape of the dose distribution.Results: To demonstrate the potential of spatial multicriteria optimization, the tool was applied to a prostate and meningioma case. For the prostate case, local sparing of the rectal wall and shaping of a boost volume are achieved through local relaxations and while maintaining the remaining dose distribution. For the meningioma, target coverage is improved by compromising low dose conformality toward noncritical structures. A comparison of dose–volume histograms illustrates the importance of spatial information for achieving the trade-offs.Conclusions: The results show that it is possible to consider the location of conflicting criteria during treatment planning. Particularly, it is possible to conserve already achieved goals with respect to the dose distribution, to visualize potential trade-offs, and to relax constraints locally. Hence, the proposed approach facilitates a systematic exploration of the optimal shape of the dose distribution.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-G-17A-01: Improving Tracking Image Spatial Resolution for Onboard MR Image Guided Radiation Therapy Using the WHISKEE Technique

Purpose: To evaluate the feasibility of using the weighted hybrid iterative spiral k-space encoded estimation (WHISKEE) technique to improve spatial resolution of tracking images for onboard MR image guided radiation therapy (MR-IGRT). Methods: MR tracking images of abdomen and pelvis had been acquired from healthy volunteers using the ViewRay onboard MRIGRT system (ViewRay Inc. Oakwood Village, OH) at a spatial resolution of 2.0mm*2.0mm*5.0mm. The tracking MR images were acquired using the TrueFISP sequence. The temporal resolution had to be traded off to 2 frames per second (FPS) to achieve the 2.0mm in-plane spatial resolution. All MR images were imported into the MATLAB software. K-space data were synthesized through the Fourier Transform of the MR images. A mask was created to selected k-space points that corresponded to the under-sampled spiral k-space trajectory with an acceleration (or undersampling) factor of 3. The mask was applied to the fully sampled k-space data to synthesize the undersampled k-space data. The WHISKEE method was applied to the synthesized undersampled k-space data to reconstructed tracking MR images at 6 FPS. As a comparison, the undersampled k-space data were also reconstructed using the zero-padding technique. The reconstructed images were compared to the original image. The relatively reconstruction error was evaluated using the percentage of the norm of the differential image over the norm of the original image. Results: Compared to the zero-padding technique, the WHISKEE method was able to reconstruct MR images with better image quality. It significantly reduced the relative reconstruction error from 39.5% to 3.1% for the pelvis image and from 41.5% to 4.6% for the abdomen image at an acceleration factor of 3. Conclusion: We demonstrated that it was possible to use the WHISKEE method to expedite MR image acquisition for onboard MR-IGRT systems to achieve good spatial and temporal resolutions simultaneously. Y. Hu and O. green receive travel reimbursement from ViewRay. S. Mutic has consulting and research agreements with ViewRay. Q. Zeng, R. Nana, J.L. Patrick, S. Shvartsman and J.F. Dempsey are ViewRay employees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of spatial modes in half-disk lasers based on AlGaAsSb/InGaAsSb quantum well nanoheterostructures

Spectral and spatial distributions of the emission of whispering-gallery-mode (WGM) lasers with a half-disk cavity have been studied. Up to 13 broad lobes with different intensities, subdivided into order-of-magnitude narrower lobes, are distinguished in the spatial distribution. The emission spectrum is nearly single-mode. A mathematical model of the electromagnetic field distribution in a WGM laser is suggested, and the radiation pattern of the laser is calculated. It is shown that each lobe corresponds to its own stable radial spatial mode. The highest emission intensity is provided not by the peripheral mode itself, but by the next-closest mode, which presumably exhibits the lowest optical loss. The predominance of a single spatial mode results in a nearly single-mode emission spectrum being observed.

36 MATERIALS SCIENCE↗