Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Satellite-based interference analyzer

System identifies terrestrial sources of radiofrequency interference and measures their frequency spectra and amplitudes. Designed to protect satellite communication networks, system measures entire noise spectrum over selected frequency band and can raster-scan geographical region to locate noise sources. Once interference is analyzed, realistic interference protection ratios are determined and mathematical models for predicting ratio-frequency noise spectra are established. This enhances signal-detection and locates optimum geographical positions and frequency bands for communication equipment.

Varice, H.↗

Development of Experimental and Computational Aeroacoustic Tools for Advanced Liner Evaluation

Acoustic liners in aircraft engine nacelles suppress radiated noise. Therefore, as air travel increases, increasingly sophisticated tools are needed to maximize noise suppression. During the last 30 years, NASA has invested significant effort in development of experimental and computational acoustic liner evaluation tools. The Curved Duct Test Rig is a 152-mm by 381- mm curved duct that supports liner evaluation at Mach numbers up to 0.3 and source SPLs up to 140 dB, in the presence of user-selected modes. The Grazing Flow Impedance Tube is a 51- mm by 63-mm duct currently being fabricated to operate at Mach numbers up to 0.6 with source SPLs up to at least 140 dB, and will replace the existing 51-mm by 51-mm duct. Together, these test rigs allow evaluation of advanced acoustic liners over a range of conditions representative of those observed in aircraft engine nacelles. Data acquired with these test ducts are processed using three aeroacoustic propagation codes. Two are based on finite element solutions to convected Helmholtz and linearized Euler equations. The third is based on a parabolic approximation to the convected Helmholtz equation. The current status of these computational tools and their associated usage with the Langley test rigs is provided.

Jones, Michael G.↗

Noncontacting method for measuring angular deflection

An apparatus is described for indicating the instantaneous angular deflection of an object about a selected axis without mechanical contact with the object. Light from a light source is transmitted through a flat refractor to a converging lens which focuses the light through another flat refractor onto a differential photocell. The first flat refractor is attached to the object such that when the object is deflected about the selected axis the refractor is also deflected about that axis. The two flat refractors are identical and they are placed an equal distance from the converging lens as are the light source and the photocell. The output of the photocell which is a function of image displacement is fed to a high gain amplifier that drives a galvanometer which rotates the second flat refractor. The second refractor is rotated so that the image displacement is very nearly zero making the galvanometer current a measure of the deflection of the object about the selected axis.

Bryant, E. L.↗

Cataloged infrared sources in NIPSS data. I - The RSO 1 catalog

A small number of selected near-infrared and visual photographic pairs from the Steward Observatory Near Infrared Photographic Sky Survey have been examined for content of stars more red than (V-I) of about 2.5 magnitudes. A simple manual extraction of these objects was carried out as a part of a preliminary evaluation of survey data and techniques for reducing it; the resulting list has been compiled as the first installment of a Catalog of Red Stellar Objects (Craine et al. 1979). Results of a cross correlation of this catalog with the IRC, AFGL, and EIC infrared catalogs are here presented. The results indicate that these photographs may be particularly useful for purposes of optical identification of short-wavelength infrared sources to limits much fainter than represented by presently existing infrared catalogs.

Horner, V. M.↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

Mariner-Venus-Mercury optical navigation demonstration - Results and implications for future missions

Optical navigation uses spacecraft television pictures of a target body against a known star background in a process which relates the spacecraft trajectory to the target body. This technology was used in the Mariner-Venus-Mercury mission, with the optical data processed in near-real-time, simulating a mission critical environment. Optical data error sources were identified, and a star location error analysis was carried out. Several methods for selecting limb crossing coordinates were used, and a limb smear compensation was introduced. Omission of planetary aberration corrections was the source of large optical residuals.

Acton, C. H., Jr.↗

SP-100 materials technology for SEI applications

General Electric and selected National laboratories are developing the SP-100 concept under the sponsorship of DOE,NASA and SDIO. Near term Space Exploration Initiative goals include the establishment of a lunar base, interplanetary manned missions, and the eventual establishment of a base on Mars. All of these projected missions have substantial power requirements. The SP-100 nuclear reactor has been identified as a promising power source to meet these requirements. This paper describes the material selections for SP-100, the factors driving the selection, and the progress to date in solving fabrication problems and producing the necessary properties data base.

Ring, P. J.↗

Remote sensing impact on corridor selection and placement

Computer-aided corridor selection techniques, utilizing digitized data bases of socio-economic, census, and cadastral data, and developed for highway corridor routing are considered. Land resource data generated from various remote sensing data sources were successfully merged with the ancillary data files of a corridor selection model and prototype highway corridors were designed using the combined data set. Remote sensing derived information considered useful for highway corridor location, special considerations in geometric correction of remote sensing data to facilitate merging it with ancillary data files, and special interface requirements are briefly discussed.

Thomson, F. J.↗

Selecting Approaches for Enabling Enterprise Data Search: NASA’s Science Mission Directorate (SMD) Catalog

NASA’s Science Mission Directorate (SMD) is working to build an open-source science infrastructure to accelerate open, collaborative and interdisciplinary science. One key component in the open-source science infrastructure is the SMD data catalog. In this paper, we present our process for selecting a technical approach to building a NASA SMD enterprise-wide integrated search capability for science users across multiple science disciplines to support discovery and access to complex scientific data.

Kaylin Bugbee↗

Strategy for selecting Mars Pathfinder landing sites

A strategy for Pathfinder site selection must be developed that is fundamentally different from most previous considerations. At least two approaches can be identified. In one approach, the objective is to select a site representing a key geologic unit on Mars, i.e., a unit that is widespread, easily recognized, and used frequently as a datum in various investigations. The second approach is to select a site that potentially affords access to a wide variety of rock types. Because rover range is limited, rocks from a variety of sources must be assembled in a small area for sampling. Regardless of the approach taken in site selection, the Pathfinder site should include eolian deposits and provisions should be made to obtain measurements on soils. A recommended approach for selecting the Mars Pathfinder landing site is to identify a deltaic deposit, composed of sediments derived from sources of various ages and geologic units that shows evidence of eolian activity. The site should be located as close as possible to the part of the outwash where rapid deposition occurred because the likelihood of 'sorting' by size and composition increases with distance, decreasing the probability of heterogeneity. In addition, it is recommended that field operation tests be conducted to gain experience and insight into conducting science with Pathfinder.

Greeley, Ronald↗

The Swift Burst Alert Telescope Detected Seyfert 1 Galaxies: X-Ray Broadband Properties and Warm Absorbers

We present results from an analysis of the broadband, 0.3-195 keV, X-ray spectra of 48 Seyfert 1-1.5 sources detected in the very hard X-rays with the Swift Burst Alert Telescope (BAT). This sample is selected in an all-sky survey conducted in the 14-195 keV band. Therefore, our sources are largely unbiased toward both obscuration and host galaxy properties. Our detailed and uniform model fits to Suzaku/BAT and XMM-Newton/BAT spectra include the neutral absorption, direct power-law, reflected emission, soft excess, warm absorption, and narrow Fe I K[alpha] emission properties for the entire sample. We significantly detect O VII and O VIII edges in 52% of our sample. The strength of these detections is strongly correlated with the neutral column density measured in the spectrum. Among the strongest detections, X-ray grating and UV observations, where available, indicate outflowing material. The ionized column densities of sources with O VII and O VIII detections are clustered in a narrow range with Nwarm [approx] 1021 cm-2, while sources without strong detections have column densities of ionized gas an order of magnitude lower. Therefore, we note that sources without strong detections likely have warm ionized outflows present but at low column densities that are not easily probed with current X-ray observations. Sources with strong complex absorption have a strong soft excess, which may or may not be due to difficulties in modeling the complex spectra of these sources. Still, the detection of a flat [Gamma] [approx] 1 and a strong soft excess may allow us to infer the presence of strong absorption in low signal-to-noise active galactic nucleus spectra. Additionally, we include a useful correction from the Swift BAT luminosity to bolometric luminosity, based on a comparison of our spectral fitting results with published spectral energy distribution fits from 33 of our sources.

Winter, Lisa M.↗

A very-long-baseline interferometer system for geodetic applications

A very-long-baseline interferometer system was designed and built for geodetic applications. Each interferometer terminal records a 360-kHz spectral band of noise from a compact extragalactic radio source. The center frequency of the spectral band can be selected to sample sequentially bands covering a much wider frequency range to obtain subnanosecond accuracy in group-delay measurements. A tunnel-diode pulse generator is used to calibrate the delays in the receiver. The necessary sets of algorithms and computer programs have been developed to analyze the data and have allowed the system to be employed to make accurate determinations of vector baselines, radio-source positions, polar motion, and universal time.

Whitney, A. R.↗

Concept selection and analysis of large wind generator systems

The increasing need to develop alternative energy sources has renewed interest in the use of wind energy for the generation of utility quality electricity. This paper discusses a program to evolve a preliminary design of a cost competitive large wind generator system. An examination of a number of technically feasible alternative wind energy configurations is reported, and the rationale used in selecting the preferred system concept is presented. In addition, preliminary results of an optimization study conducted on the preferred concept are summarized. These show that considerable latitude in the selection of the system design parameters is possible. This permits design decisions to be based on other important factors such as development risk and the suitability of common component designs for systems with different power ratings.

Meier, R. C.↗

Design of an Acoustic Shielding Flap Concept with Prediction and Validation

As part of a NATO task group, NASA has designed a noise reduction technology called a Shielding Flap for application to a hybrid wing body aircraft concept. The design drivers and objectives for this technology are outlined in this paper. Design parameters are defined, and recently-developed NASA software for prediction of acoustic scattering is used to investigate the expected performance of the technology for a range of parameter values. Detailed scattering computational results are presented for several simulated noise sources and for many variations of the shielding flap concept. A selection of computational results is compared with experimental data collected in the NASA Langley Quiet Flow Facility. Overall, the results indicate that the Shielding Flap has strong potential to reduce aft-radiated noise, which was a primary design objective, by shielding sound from the simulated sources while also shielding sound that is scattered from the main airframe.

Propulsion Airframe Aeroacoustics↗

SEI power source alternatives for rovers and other multi-kWe distributed surface applications

To support the Space Exploration Initiative (SEI), a study was performed to investigate power system alternatives for the rover vehicles and servicers that were subsequently generated for each of these rovers and servicers, candidate power sources incorporating various power generation and energy storage technologies were identified. The technologies were those believed most appropriate to the SEI missions, and included solar, electrochemical, and isotope systems. The candidates were characterized with respect to system mass, deployed area, and volume. For each of the missions a preliminary selection was made. Results of this study depict the available power sources in light of mission requirements as they are currently defined.

Bents, David J.↗

SEI power source alternatives for rovers and other multi-kWe distributed surface applications

Results of the study performed to support the Space Exploration Initiative (SEI) which investigated power system alternatives for the rover vehicles and servicers that would be used for construction and operation of a lunar base is described. Using the mission requirements and power profiles that were subsequently generated for each of these rovers and servicers, candidate power sources incorporating various power generation and energy storage technologies were identified. The technologies were those believed most appropriate to the SEI missions, and included solar, electrochemical, and isotope systems. The candidates were characterized with respect to system mass, deployed area and volume. For each of the missions a preliminary selection was made. Results of this study depict the available power sources in light of the mission requirements as they are currently defined.

Bents, D. J.↗

Spectral energy distributions of nuclei of peculiar galaxies.

Consideration of galaxies of the types described by Seyfert, Zwicky, Markarian and others. Quasars are discussed in terms of their similarities to the nuclei of peculiar galaxies. The data discussed were obtained almost exclusively with photoelectric spectrometers. Peculiar galaxies have a wide range of properties insofar as their spectra are concerned. Many have very strong emission lines. Sources of continuous radiation, and distance scale problems and selection effects are discussed. Data are presented which are representative of spectrophotometric observational results for 12 Markarian galaxies, 14 Zwicky compact objects, and 16 radio galaxies. The general properties of spectral energy distributions of peculiar galaxies and quasars are discussed.

Oke, J. B.↗

Measurement of instrument noise spectra at frequencies below 1 hertz

The use of peak-to-peak values in describing output noise of a magnetometer or low frequency amplifier is of questionable value for certain applications. A more precise statement of instrument noise is made with a plot of the noise power spectral density vs frequency. The spectral density plot provides a rich source of information which can be used in the selection and testing of such instrumentation.

Snare, R. C.↗