Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “source range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Observations of Taurus X-1 by the 1-60 keV X-ray detector on the OSO-7.

The seventh Orbiting Solar Observatory, OSO-7, carries an X-ray detector for measuring the positions, spectra, and time variations of X-ray sources in the energy range from 1 to 60 keV. The instrument has operated successfully since the launch on 1971 September 29. The purpose of this paper is to describe the instrument and to report a measurement of the spectrum of Tau X-1 based on data covering the widest energy range that has so far been observed in a single experiment.

Clark, G. W.↗

Studies of cluster X-ray sources, energy spectra for the Perseus, Virgo, and Coma clusters

Final Uhuru X-ray differential-energy spectra are presented for the Perseus, Virgo, and Coma clusters. Power-law and isothermal bremsstrahlung model spectra with low-energy cutoffs are given, and the energy-dependent Gaunt factor is calculated for the bremsstrahlung. The spectra, which are best fits to the Uhuru data between 2 and 10 keV, are compared with previous observations of these sources in the energy range from 0.1 to 100 keV. The problem of parameter estimation is discussed, error bars with 68% confidence are given for the independently determined slope and cutoff parameters, and the 68% confidence limits are plotted for the fitted spectral functions. The data for Perseus above 20 keV marginally favor the bremsstrahlung fit, those for Virgo between 0.25 and 1.0 keV clearly favor that curve, and those for Coma indicate a low-energy turnover or cutoff. Implications of such a cutoff are briefly discussed.

Kellogg, E.↗

Intercomparison of neutral composition measurements from the satellite Esro 4, Aeros A, Aeros B, and Atmosphere Explorer C

Number-density data obtained at orbital 'crossover' points with the neutral-gas mass spectrometers aboard the Esro 4, Aeros A, AE-C, and Aeros B satellites are intercompared. All the mass spectrometers were designed to measure the ambient number densities of atomic oxygen, molecular nitrogen, helium, and argon. It is found that the agreement for N2 and O is satisfactory within the experimental errors and that the He measurements exhibit unexpectedly large discrepancies far outside the error range. Calibration and instrument sources of error are considered.

Trinks, H.↗

The Focal Plane Crystal Spectrometer for the HEAO-B satellite

The very low flux from even the brightest (non-solar) X-ray source has discouraged the use of instruments with high spectral resolution because of their inevitably low sensitivity. Mission B of the High Energy Astronomy Observatory will provide the first opportunity for moderate and high resolution spectral studies of celestial X-ray sources with high sensitivity. The Focal Plane Crystal Spectrometer (FPCS) described here is the instrument with the highest spectral resolution. It is designed to allow detailed spectral studies of both point and extended celestial sources in the energy range 0.2-3.3 keV with resolutions of 50 to 1000.

Donaghy, J. F.↗

Theory for charge states of energetic oxygen ions in the earth's radiation belts

Fluxes of geomagnetically trapped energetic oxygen ions have been studied in detail. Ion distributions in radial locations below the geostationary orbit, energy spectra between 1 keV and 100 MeV, and the distribution over charge states have been computed for equatorially mirroring ions. Both ionospheric and solar wind oxygen ion sources have been considered, and it is found that the charge state distributions in the interior of the radiation belts are largely independent of the charge state characteristics of the sources. In the MeV range, oxygen ions prove to be a more sensitive probe for radiation belt dynamics than helium ions and protons.

Spjeldvik, W. N.↗

The curved crystal X-ray spectrometer for the HEAO-B satellite

The Focal Plane Crystal Spectrometer on HEAO-B is a moderate to high resolution, curved-crystal, Bragg spectrometer which operates behind a grazing incidence X-ray telescope. It is designed to allow detailed spectral studies of both point and extended celestial X-ray sources in the energy range 0.2-3.3 keV, with resolutions of 50 to 1000. The analyzing elements are six torroidal diffractors, and the detectors are position-sensitive, flow, proportional counters. HEAO-B is scheduled for launch in June, 1978.

Canizares, C. R.↗

A practical approach to helicopter internal noise prediction

A practical and well correlated procedure for predicting helicopter internal noise is presented. It accounts for the propagation of noise along multiple paths on an octave by octave basis. The method is sufficiently general to be applicable to conventional helicopters as well as other aircraft types, when the appropriate structural geometry, noise source strengths, and material acoustic properties are defined. A guide is provided for the prediction of various helicopter noise sources over a wide range of horsepower for use when measured data are not available. The method is applied to the prediction of the interior levels of the Civil Helicopter Research Aircraft (CHRA), both with and without soundproofing installed. Results include good correlation with measured levels and prediction of the speech interference level within 1.5 db at all conditions. A sample problem is also shown illustrating the use of the procedure. This example calculates the engine casing noise observed in the passenger cabin of the CHRA.

Levine, L. S.↗

Ion implantation of solar cell junctions without mass analysis

This paper is a summary of an investigation to determine the feasibility of producing solar cells by means of ion implantation without the use of mass analysis. Ion implants were performed using molecular and atomic phosphorus produced by the vaporization of solid red phosphorus and ionized in an electron bombardment source. Solar cell junctions were ion implanted by mass analysis of individual molecular species and by direct unanalyzed implants from the ion source. The implant dose ranged from 10 to the 14th to 10 to the 16th atoms/sq cm and the energy per implanted atom ranged from 5 KeV to 40 KeV in this study.

Fitzgerald, D.↗

Electron beam charging and arc discharging of spacecraft insulating materials

Samples of Mylar and Teflon film were exposed to combinations of monoenergetic electron and lithium ion fluxes in various ratios. The samples' discharge rates and strengths were found to diminish as the ion proportion increased. Various types of capacitors were exposed in air to beta irradiation from a 100 mCie Strontium-90 radioisotope source located at distances ranging from 2 cm to 5 cm from the capacitors. In these preliminary experiments, no evidence of spontaneous electrical breakdown was noted, nor was any change in RF impedance detectable using the available instrumentation. A decrease in DC resistance was noted, apparently due to radiation-induced conductivity. A cylindrical glass vacuum chamber is being assembled. Its inside dimensions are 44 cm diameter by 100 cm length. All necessary associated components and instruments have been acquired, including electron and ion guns, Trek surface potential probe and turbo-molecular pump. A mass-spectrometer detector for leaks and evolved gases will be ordered shortly.

Balmain, K. G.↗

An evaluation of circumferentially segmented duct liners

An evaluation of circumferentially segmented duct linings are performed by comparing attenuations of optimized segmented and uniform linings for a range of frequencies and source structures. Broadband suppression and the effects of changes to input modal structure are explored in these comparisons. Credence in the theoretical model was obtained by comparing predictions to results of a carefully controlled experiment performed on the Spinning Mode Synthesizer facility at the NASA Langley Research Center. Excellent agreement was obtained in these comparisons. Predicted results show that the optimized segmented liner is more effective than the optimized uniform liner for the higher order spinning mode sources with a hard-wall/soft-wall admittance variation representing an optimum configuration for the segmented liner. Predicted results also indicate that the segmented linear gives better broadband performance and that its suppression characteristics are not particularly sensitive to changes in input modal structure when compared to that of the uniform lining. It is shown that the greatest suppression benefit of segmented linings occur near mode cuton frequencies and that these benefits are obtained despite reductions in the total amount of acoustic treatment of fifty percent or more.

Watson, W. R.↗

Observations of continuum X-ray and gamma-ray emission from the galactic center

A review of observations of the galactic nucleus to date in the X ray and gamma ray regions is presented. Attention is given to data in the 1-10 keV, 10-100 keV, 100 keV to 10 MeV, and 10 MeV to 1 GeV ranges. It is shown that the galactic nucleus is as yet unresolvable from the other galactic center at energies above 4.5 keV, while large variations in the observed flux in the 100 keV-1 MeV range indicate a single source as the dominant emitter. An X ray source is concluded to be contained in the nucleus, which features a constant luminosity of 1.5 x 10 to the 35th erg/sec in the 0.5-4.5 keV band. A hard and bright source is located near the nucleus, whose emitter source exists at a temperature of about 10 billion K with a luminosity 30 times that of the Crab Nebula.

Matteson, J. L.↗

Temporal variations of the anomalous oxygen component

Data from the cosmic ray experiment on Voyagers 1 and 2 was used to examine anomalous oxygen in the time period from launch in 1977 to the end of 1981. Several time periods were found where large periodic (typically 26 day) temporal variations of the oxygen intensity between approximately 5 - 15 MeV/nuc are present. Variations in intensity by up to a factor of 10 are observed during these periods. Several characteristics of these variations indicate that they are not higher energy extensions of the low energy particle (approximately 1 MeV/nuc) increases found in many corotating interaction regions (CIR's). Many of these periodic temporal variations are correlated with similar, but much smaller, recurrent variations in the 75 MeV proton rate. Voyager 1 and Voyager 2 counting rates were compared to estimate the local radial gradient for both the protons and the oxygen. The proton gradients during periods of both maximum and minumum fluxes are consistent with the overall positive radial gradients reported by others from Pioneer and near-Earth observations, supporting the view that these variations are due to local modulation of a source outside the radial range of project measurements. In contrast, the oxygen gradients during periods of maximum proton flux differ in sign from those during minimum proton fluxes, suggesting that the origin of the oxygen variations is different from that of the protons.

Cummings, A. C.↗

The statistical uncertainty of flux densities in the IRAS serendipitous survey

The statistical uncertainty in the flux densities reported in the IRAS Serendipitous Survey Catalog (1986) is analyzed by examining differences in the measurements of sources in two independent observations. An assessment of the statistical uncertainty as a function of flux density in the Catalog has been made by accumulating these differences for over 4000 sources spanning a brightness range from 0.05 to over 20 Jy. The functional forms of the relative uncertainties at 12, 25, 60, and 100 microns are presented.

Cutri, Roc M.↗

Ada (R) assessment: An important issue within European Columbus Support Technology Programme

Software will be more important and more critical for Columbus than for any ESA previous project. As a simple comparison, overall software size has been in the range of 100 K source statements for EXOSAT, 500 K for Spacelab, and will probably reach several million lines of code for Columbus (all element together). Based on past experience, the total development cost of software can account for about 10 pct to 15 pct of the total space project development cost. The Ada technology may support the strong software engineering principles needed for Columbus, provided that technology is sufficiently mature and industry plans are meeting the Columbus project schedule. Over the past 3 years, Informatique Internationale has conducted a coherent program based on Ada technology assessment studies and experiments, for ESA and CNES. This specific research and development program benefits from 15 years experience in the field of space software development and is supported by the overall software engineering expertise of the company. The assessment and experiments of Ada software engineering by Informatique Internationale are detailed.

Vielcanet, P.↗

Offset, tilted dipole models of Uranian smooth high-frequency radio emission

The smooth high-frequency (SHF) component of the radio emission detected during the Voyager 2 encounter with Uranus (January 1986) is studied. An offset tilted dipole (OTD) investigation of the SHF emission at L shells is carried out within the range of the bursty source locations. A viable high L shell model is presented. It is suggested that Miranda, which reaches a minimum L shell at L = 5, may be related to the timing of several types of radio emissions.

Schweitzer, Andrea E.↗

Novel Si(1-x)Ge(x)/Si heterojunction internal photoemission long-wavelength infrared detectors

The feasibility of a novel p(+)-Si(1-x)Ge(x)-p-Si heterojunction internal photoemission (HIP) IR detector is demonstrated. A degenerately doped p(x)-Si(1-x)Ge(x) layer is required for strong IR absorption to generate photoexcited holes. The Si(1-x)Ge(x) layers are grown by molecular beam epitaxy, with boron concentrations up to 10 to the 20th/cu cm achieved by using an HBO2 source. Photoresponse at wavelengths ranging from 2 to 10 microns has been obtained with quantum efficiencies above 1 percent. The tailorable cutoff wavelength of the HIP detector has been demonstrated by varying the Ge composition ratio in the Si(1-x)Ge(x) layers.

Lin, T. L.↗