Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “safety evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Summary Report)

This summary report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. A companion full report provides additional information and discussion of the tested products, test methods, and results. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accelerating CO2 Storage Site Characterization through a New Understanding of Favorable Formation Properties and the Impact of Core-Scale Heterogeneities

CO2 sequestration in deep geologic formations can permanently reduce atmospheric CO2 emissions and help to abate climate change. Target formations must undergo a time- and resource-intensive site evaluation process, assessing storage capacity, environmental safety, and suitability for CO2 trapping via reactive transport models based on data from a limited number of core samples. As such, simulations are often simplified and omit heterogeneities in formation properties that may be significant but are not well understood. To facilitate more rapid site assessment, this work first defines the aquifer properties of favorable storage formations through the analysis of promising and active storage sites. Data show quartz is the most prevalent formation mineral with carbonate minerals, highly reactive with injected CO2, present in over 75% of formations. Porosity and permeability data are highly clustered at 10–30% and 10–1000 mD. Field-scale reactive transport simulations are then constructed and used to analyze CO2 trapping efficiency. The models consider porosity and carbonate mineral heterogeneity as well as the impacts of typical temperature gradients. Simulated sequestration efficiencies are compared to results from a comparable homogenous model to understand the implications of aquifer non-uniformities. The results show a lower sequestration efficiency in the homogeneous model during the injection phase. During the post-injection phase, the homogenization of porosity and carbonate mineralogy results in a higher sequestration efficiency. Incorporating the temperature gradient also increases the sequestration efficiency. Importantly, the maximum deviation between the homogeneous and heterogeneous simulations at the end of the 50-year study period is only ~10%. Larger impacts may be incurred for properties outside the defined, promising ranges suggested here.

Environmental Sciences & Ecology↗

239 Pu R -matrix Analysis and Neutron Multiplicities in the Neutron Energy Region up to a few keVs [Abstract]

The evaluation of 239 Pu neutron resonance parameters coupled to neutron multiplicities $\overline{v}_p$ is of particular importance to investigate the ($\mathcal{n, γf}$) reaction in which a $\mathcal{γ}$-ray emission occurs before the scission of the compound nuclear. This reaction has offered one explanation for the fluctuations in the measured values of $\overline{v}_p$ In this regard, the competition between ($\mathcal{n, γf}$) reaction and the direct fission process can be also included in the R matrix analysis of fission and capture measured data. The goal of this work is the coupled evaluation of the $\mathcal{n}$+ 239 Pu resonance parameters and related neutron multiplicities by ensuring the adoption of thermal neutron constants recently evaluated at the International Atomic Nuclear Energy as well as the recommended (thermal-neutron) induced prompt neutron fission spectrum (PFNS). Moreover, this new set of physical evaluated quantities should also guarantee the agreement for high-leakage solution benchmarks while keeping the good performance of large thermal solution assemblies.

07 ISOTOPE AND RADIATION SOURCES↗

Update on NNL TSL Validation Efforts [Slides]

This presentation covers how a new sub-thermal neutron transmission capability at RPI LINAC is now in use to help validate TSL evaluations. Additionally, NNL has contributed multiple material evaluations to ENDF/B-VIII.1. Lastly, this presentation covers new methods to improve TSL physics and accuracy are being formulated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ECAR-7210 Rev 0 Steady-state Thermo-mechanical Analysis of the MARVEL Fuel Bundle

This document reports the steady-state thermal-hydraulic and static mechanical analyses of the MARVEL micro-reactor core. The objective of this work is to investigate whether fuel-to-fuel contact could occur due to the thermal deformation of the fuel cladding during the normal operation and to assess the resulting impact on the peak cladding temperatures (PCT) if contact occurs. The scope of the work consists of three computational tasks. First, a conjugate heat transfer analysis using computational fluid dynamics (CFD) model was performed to evaluate the PCTs during normal operating conditions. Second, a finite element analysis (FEA) using the cladding temperature field obtained from the CFD analysis was performed to evaluate the thermal deformation of cladding and determine the occurrence of fuel-to-fuel contact. Finally, a CFD analysis of FEA-informed fuel-to-fuel gap (represented by a conservative 0.05 mm uniform gap) was performed to evaluate whether the PCT exceeds the safety criteria.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Evaluating Connected and Automated Vehicles in Co-Simulation Environment of Traffic Microsimulation and Vehicle Dynamics

Connected and automated vehicles (CAVs) have the potential to improve many aspects of the current transportation systems such as safety, mobility, and energy efficiency. In order to evaluate the benefits and impacts of a CAV, the CAV control algorithm is typically implemented on vehicles simulated in a traffic microsimulation environment. However, traffic microsimulation usually lacks detailed vehicle and powertrain dynamics, making it challenging to fully understand how a CAV control algorithm will perform and respond on an actual vehicle. Whether the same benefits measured in the simulation will also be observed in real-world remains an open question. One potential approach to fill in this gap is to conduct a co-simulation of traffic microsimulation with detailed vehicle and powertrain dynamics models, often developed in MATLAB Simulink. However, current microsimulation tools such as VISSIM and SUMO do not have a ready-to-use interface for co-simulation with vehicle dynamics and Simulink. Also, even if such an interface exists, it will be tool-specific, making it challenging to shift from one tool to another or test CAV controls in different tools. There are needs for tool-agnostic co-simulation as different microsimulation tools have their pros and cons, and researchers often need to use different tools based on the purposes of the simulation, project needs, and applications. In this work, Flexible Interface for X-in-the-loop Simulation (FIXS) is developed that can support the co-simulation of microsimulation, CAV control algorithm, and vehicle dynamics model in Simulink. Enabled by the FIXS, the benefit and performance of a CAV control algorithm can be better understood with the consideration of vehicle responses and dynamics. The connection to VISSIM and SUMO is handled internally by the interface, and users can easily switch tools by changing a configuration file. The co-simulation capability is demonstrated for a VISSIM eco-approach and departure CAV scenario and a SUMO cooperative merging scenario for both a passenger CAV and a class 8 heavy-duty connected and automated trucks.

Shao, Yunli↗

Evaluation of H-Canyon Ventilation Exhaust Tunnel Inspection at the Savannah River Site - 20052

The Department of Energy (DOE) H-Canyon Facility at the Savannah River Site (SRS) is operated by Savannah River Nuclear Solutions (SRNS). The Facility Structural Integrity Program [1] provides a process to inspect, evaluate, and document the conditions of passive safety related structural systems and components, their degradation mechanisms and their impact on the safety envelope. The Structural Integrity Program performs periodic visual inspections to confirm the systems and components can perform their safety function and recommend corrective actions before the function is compromised. The H-Canyon Exhaust Tunnel is part of the H-Canyon Ventilation System and is periodically inspected under the Structural Integrity Program. The Tunnel performs a Safety Class passive design feature function that is available 100% of the time. The underground reinforced concrete Tunnel directs Canyon process air from the Canyon to the Sand Filter System. The radiological and chemical airborne activity coupled with the physical configuration of the tunnel precludes a manned entry into the tunnel to perform the inspection. Unlike active systems that can be subjected to physical testing to confirm capability, qualification calculations, including modeling, is performed to assess passive design feature capabilities relative to operational, accident and natural phenomena hazards events. Input for these calculations come from knowledge of field conditions, design drawings and conservative assumptions. The knowledge of field conditions comes from concrete and soil testing activities as well as inspection data. The use of cameras on crawlers to obtain inspection data and how that data is used in qualification calculations is the focus of this discussion. Remote Tunnel inspections have been performed using cameras on a stick, referred to as pole cameras, prior to Calendar Year 2003 (CY2003). Since CY2003, six camera equipped crawlers have been used. Crawlers have evolved and improved by incorporating lessons learned from the previous inspections. The latest 2019 crawler successfully traveled the entire length of the tunnel between the Canyon and Sand Filter System and captured images that were previously unseen, thus providing key visual data for the Structural Integrity Program report [2]. The inspection data serves as 1) input to qualification calculations, 2) validates current conditions remain bounded by qualification calculations, and 3) documents a record of change over time. This data is vital for the effective evaluation of the tunnel structure and aids with predicting the life cycle service life safety envelope to protect the public, environment, and facility worker. The goal of the 2019 deployment was to use a more robust vehicle to ensure travel over obstacles, perform the inspection with higher resolution cameras, and have the ability to elevate the cameras to view surfaces previously obscured by abandon-in-place ducts in the tunnel. The inspection information will serve to strengthen the input basis for qualification calculations, versus using excessive conservative calculation assumptions. This 2019 inspection was compared with previous crawler visual evidence to identify change over time to project remaining service life and confirm field conditions remain bounded by qualification calculations. The results of the 2019 Exhaust Tunnel inspection continue to improve and provide a firm basis to make sound engineering judgements regarding tunnel capability and approaches in projecting remaining service life with an aging system and component. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deuterium trapping mechanisms in reduced activation ferritic martensitic steels and their correlation with mechanical strengthening

Development of high-strength materials often involves introduction of additional strengthening microstructures that also serve as tritium trapping sites. Such additions in fusion material development could degrade the fuel efficiency in fusion reactors and raise radiological concerns. The contribution of individual microstructure features in hydrogen trapping must be evaluated to ensure fuel efficiency and radiological safety. This study explores the mechanistic origins of deuterium trapping in reduced-activation ferritic–martensitic steels and its correlation to mechanical strengthening. A series of model alloys and engineering steels were fabricated and subjected to different heat treatments to control deuterium trapping site density. Deuterium retention was evaluated using D 2 gas charging and thermal desorption spectroscopy, focusing on the role of grain boundary, dislocation, M 23 C 6 precipitates, and TiC precipitates. Multiscale microstructure characterization and synchrotron X-ray diffraction were performed to characterize microstructure, which was correlated to the deuterium retention property. Results show that TiC precipitates exhibit the highest deuterium trapping capacity, followed by M 23 C 6 precipitates. Dislocation and grain boundary demonstrate the lowest and similar efficiencies. Furthermore, the relationship of trapping quantity and mechanical strengthening of these microstructure features was quantified, demonstrating that TiC precipitates offer highest deuterium trapping per unit of mechanical strengthening.

Retention↗

The Technical, Economic, Risk, and Adoption Assessment for Evaluating Work Reduction Opportunities in the Nuclear Industry

Automation and cost-saving initiatives, such as process automation with advances in artificial intelligence, are gaining traction in modernization efforts across the nuclear industry. As these innovations are increasingly adopted, it becomes crucial to evaluate their impacts comprehensively. Various technical and economic attributes, along with risk and human readiness factors, must be achieved to ensure that innovative projects enabling automation and modernization are successful. However, no systematic or integrated framework exists that allows plants to evaluate these innovative projects. To address this gap, the Technical, Economic, Risk, and Adoption (TERA) assessment offers a structured method to evaluate innovative technologies, ensuring solutions meet both operational and safety standards. The TERA framework integrates the disparate perspectives to assess modernization opportunities in nuclear operations. It combines qualitative and quantitative models to evaluate the relationship between performance and business impacts, while also enabling continuous re-evaluation during project development. This approach helps plant owners identify high-priority opportunities, optimize cost savings, and minimize risks, ensuring projects remain on track to achieve desired returns. By providing a comprehensive, systematic methodology, TERA enables informed, data-driven decisions that support successful modernization efforts, enhancing efficiency, safety, and cost savings across nuclear operations. This paper explains the TERA framework and its benefits for the nuclear industry.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - November 2025 Meeting Notes

Fifteen years have passed since the March 11, 2011, the Great East Japan Earthquake (GEJE) triggered a tsunami that inundated the Fukushima Daiichi Nuclear Power Station (Daiichi or 1F) and led to severe accidents in multiple units at the plant. During these fifteen years since these events, Daiichi forensics examinations and evaluations have revealed many insights for enhancing the safety of nuclear power plants worldwide. However, uncertainties remain regarding the events after the GEJE. Additional Daiichi forensics information is required to inform future Decontamination and Decommissioning (D&D) activi- ties conducted by the plant owner, Tokyo Electric Power Company Holdings, Incorporated (TEPCO Hold- ings). This forensics information also has important implications for the safety and operation of U.S. commercial nuclear power plants. A collaborative U.S. and Japanese effort, which includes approximately 50 experts in reactor safety and plant operations, was initiated in 2014 by the Department of Energy Office of Nuclear Energy (U.S. DOE-NE) to identify Daiichi examination needs and evaluate recent Daiichi examination data to address these needs. This collaborative effort, which is beneficial to the U.S. and Japan, continues as Japan moves forward with D&D activities.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Assessment of Critical Experiment Benchmark Applicability to a Large-Capacity HALEU Transportation Package Concept

This work presents an assessment of the applicability of existing benchmark critical experiments to the criticality safety code validation for a large-capacity high-assay low-enriched uranium (HALEU) transportation package concept. Numerous next-generation nuclear reactor designs require HALEU fuel, which is characterized by an enrichment between 5 and 20 wt% 235 U. The U.S. Department of Energy (DOE) has proposed to recover and downblend highly enriched uranium from DOE-owned used nuclear fuel to accelerate the demonstration of commercially viable microreactor technologies. One element of the infrastructure needed to demonstrate HALEU-fueled reactors is the ability to safely transport enriched product to be used for fuel fabrication. There is uncertainty as to whether existing critical benchmark experiment data are sufficient to support criticality safety code validation for HALEU transportation applications. The anticipated chemical form of the HALEU in the proposed transportation concept is UO 2 with 20 wt% 235 U/U. The concept uses a combination of an existing transportation packaging design and a novel basket design, including borated aluminum flux traps. The basket provides space for 18 reusable, stainless steel canisters that contain the HALEU. In 10 CFR 71, normal conditions of transport (NCTs) and hypothetical accident conditions (HACs) are defined for fissile material transportation packages. NCT and HAC KENO-VI models of the transportation package were developed using the Standardized Computer Analyses for Licensing Evaluation (SCALE) 6.2.3 computer code package, and optimum moderation conditions were determined using the SCALE SAMPLER sequence. The SCALE Tools for Sensitivity and Uncertainty Analysis Methodology Implementation (TSUNAMI) sequences were then used to compare the neutronic characteristics of 1584 International Criticality Safety Benchmark Evaluation Project benchmark critical experiments with the NCT and HAC HALEU transportation models. The TSUNAMI integral correlation coefficient c k was the criterion used to rank neutronic similarity. Thirty-four experiments were identified as similar (c k ≥ 0.9) to the NCT model, and 55 experiments were identified as similar to the HAC model. Hundreds of experiments were also identified as at least marginally similar (c k ≥ 0.8) to both models. The results indicate that additional critical experiments are unlikely to be needed to support HALEU transportation criticality safety analyses for package concepts similar to the concept package analyzed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The Sensor Dilemma in Intelligent Transportation Systems: Evaluating Radar, Lidar and Camera: Preprint

Intelligent transportation systems (ITS) are at the forefront in advancing the way we interact with and perceive the transportation network. This revolution is fueled by the significant advancement in sensor perception technologies such as radar, lidar, and video imaging, which are the most popular modalities for ITS. Real-time perception data from these sensors allow intelligent infrastructure-side decision-making to improve the energy, efficiency, and safety at traffic intersections. As traffic departments across the United States transition from traditional loop detectors and emulators and embrace newer technologies, they are often left with a dilemma in choosing a sensor technology for infrastructure-based perception that is reliable, inexpensive, and easy to set up and that has robust performance in varying weather conditions. However, choosing a sensor that checks all these boxes is not straightforward, as every sensor type has unique benefits and drawbacks. Radar is excellent at detecting long-range vehicles and weather resistance but lacks high resolution. Lidar is expensive and weather-sensitive, while cameras provide rich visual data at a low cost but are constrained by lighting and visibility. This study examines radar, lidar, and camera sensor capabilities to ascertain whether any of these qualifies as the "best" sensor for ITS perception. While no single sensor can meet all the demands of ITS, a hybrid approach combining multiple sensor modalities like radar, lidar, and cameras offers the most robust solution for enhancing the safety and efficiency of ITS. Through this evaluation, we hope to draw attention to the necessity of the National Renewable Energy Laboratory's infrastructure perception and control framework, which presents a multisensor track data fusion engine to assimilate multiple data streams in order to provide robust and reliable perception.

33 ADVANCED PROPULSION SYSTEMS↗

Evaluation of flame propagation of retrofit energy efficient wall assemblies

Leveraging safety science experience and industry relationships, UL Solutions and the International Association of Fire Fighters (IAFF) initiated a joint project in 2022 under an agreement with the US Department of Energy to evaluate the flame propagation of retrofit energy efficient wall assemblies. A draft of the protocol from the ASTM work was used to test and comparatively study various retrofit energy efficient designs to gain a better understanding of their fire behavior. The goals of this study were as follows: Develop an understanding of fire propagation across new, cost effective, and energy efficient exterior retrofit wall assemblies. Refine the flame propagation draft test method for exterior wall assemblies based on ASTM E2707. Identify conditions that create fire propagation hazards in exterior wall assemblies and educate the fire service on the findings.

42 ENGINEERING↗

Adhesion Capabilities of Permanent Foaming Fixatives

DOE-EM have identified an operational requirement for a fixative that can immobilize and/or encapsulate residual contamination in 3D void volumes (pipes, gloveboxes, waste containers, etc.) during D and D activities. Failure to safely and effectively immobilize residual contamination can: Put workers at risk; Contaminate the public and environment; Drive up costs. Commercial-off-the-shelf (COTS) polyurethane (PU) foams is one possible solution and is currently being investigated by Savannah River National Lab (SRNL). Adhesion testing will dictate how well PU foams will adhere and immobilize residual contamination onto a substrate. Results can provide a performance criteria for Section 5 of ASTM E3191: Standard Specification for Permanent Foaming Fixatives Used to Mitigate Spread of Radioactive Contamination. Initial mechanical testing showed intumescent rigid PU foams were best in class (tensile, compression, TGA/DSC) Application of intumescent rigid PU foam in pipe scenario with 'contamination' showed excellent adhesion capabilities as long as foam had contact with pipe. The foam, however, was not able to penetrate 'contamination' but created pockets where the contamination interacted with the substrate. Pretreatment options of pipe were considered to produce better immobilization capabilities. Pretreatment options included COTS products like baking spray, rubber cement, and soap. Foam was still able to immobilize on a global sense, but not a local sense. Essentially acted as a mechanical plug. A tensile tester (MTS Criterion Series 43) was utilized to evaluate the tensile adhesion strength of 6 COTS PU foams. ASTM D1623: Tensile and Tensile Adhesion Properties of Rigid Cellular Plastics. Procedures: PU foams were cured between two smooth 2'' x 2'' 304 stainless steel coupons with hinges glued on plates for gripping support. Parameters Used: Pull rate of 0.1 in/min. Calculations: Tensile adhesion strength, elongation, and ImageJ analysis of how PU foam is left on substrate. Outcome: The PU foam with the best adhesion capabilities would be downselected for further evaluation to be used as a permanent foaming fixative. The rigid PU foams had the best adhesion capabilities with the R1 foam having a max load of 236 N. One of the I-R2 samples reached almost 450 N and another sample reached 2500 N before slipping. The other intumescent foam, I-F4, had the most coverage on the stainless steel coupon's surface from the ImageJ results (61.43% surface coverage). The intumescent foam, I-R2, will be the foam of choice for future testing due its fire retardant and adhesion capabilities. Future directions: Conduct the following experiment in a pipe scenario with the down-selected PU foam. Procedures: PU foam will be cured between in a 304 stainless steel pipe (ID: 4'', OD: 4.5'', Height: 4''). Parameters Used: Compression testing results will be referenced to determine if foam's adhesion strength would be greater its compression strength as its being compressed. Calculations: Compression strength, shear stress, total time elapsed. Conduct further adhesion testing with the down-selected PU foam (I-R2) to be treated as a permanent foaming fixative (PFF). Determine the minimum contact the PFF should have with the substrate for adequate results. Evaluate if PFF's adhesion capabilities is time dependent (3.1.5 of ASTM E3911). Subject PFF to seismic stressors addressed in Safety Basis of Interim Operation documents (SBIO) to further evaluate adhesion capabilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Chemical Process Safety at TRISO-Based, Metal-Based, and Salt-Based Fuel Fabrication Facilities: Technical Assessment and Guidance Assessment

As part of efforts to prepare for potential and ongoing safety reviews for licensing of advanced non-light-water reactor fuel cycles, the U.S. Nuclear Regulatory Commission (NRC) tasked Pacific Northwest National Laboratory to prepare an assessment on the state of knowledge of potential chemical processes at fuel cycle facilities supporting the front end of these fuel cycles, and to assess the associated regulatory guidance. This report provides a technical assessment of chemical process safety considerations to support NRC licensing reviews of fabrication processes for tri-structural isotropic (TRISO) based, metallic-based, and salt-based fuels. The assessments involved collecting publicly available information on the fuel fabrication processes to (i) identify the operational process steps, characteristics and chemicals involved, (ii) identify the physical safety considerations and health safety considerations during licensing reviews of the various process steps, and (iii) collect information to support assessments of severity of accidents and potential mitigative measures to be implemented. The assessment provides a foundational basis on chemical process safety considerations for advanced fuel fabrication activities, although it is recognized that licensing reviews may necessitate design-specific considerations. The specific conditions under which chemical hazards emerge will require process-specific considerations, highlighting the importance of process-informed interpretation. The assessment also determined that exposure guidelines and limits to assess the consequences of acute exposures are limited for some chemicals, although alternative limits and supplementary information from databases or safety data sheets provide sufficient information to evaluate consequences of acute exposures. In addition, it was identified that metallic and salt fuel fabrication processes may involve beryllium, which is an exposure hazard. The regulatory framework for the licensing of advanced fuel cycle facilities, per 10 CFR Part 70 Domestic Licensing of Special Nuclear Material, is deemed robust and flexible to address the chemical safety considerations in this report. A review was conducted on various regulatory guidance and technical basis documents. This included reviewing NUREG-1520, Revision 2, Standard Review Plan for Fuel Cycle Facilities License Applications – Final Report and the process descriptions in Appendix A of NUREG/CR-6410, Nuclear Fuel Cycle Facility Accident Analysis Handbook, to address advanced fuel types. As new fuels will involve process-specific chemical uses, process-specific considerations are provided in this report. Additionally, it is noted that the U.S. Department of Energy protective action criteria database includes Temporary Emergency Exposure Limits (TEELs) for process-specific chemicals. This report provides technical information to support chemical safety assessments of new advanced fuel cycle facilities and identifies technical and safety information to support licensing reviews. No regulatory barriers were identified for the licensing of advanced fuel cycle facilities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Molten Salt Reactor Fundamental Safety Function PIRT

The phenomenon identification and ranking table (PIRT) process was employed to evaluate the current capability to assess the ability of liquid-salt–fueled molten salt reactors to achieve their fundamental safety functions (FSFs). The PIRT process provides a structured mechanism to elicit and document expert opinions on the most important phenomena and the corresponding level of knowledge with regard to achieving the FSFs. The PIRT panel included reactor developers, accident progression evaluation tool developers, US Department of Energy (DOE) national laboratory technical staff, university researchers, and US Nuclear Regulatory Commission (NRC) staff. The information-gathering process concentrated on phenomena related to accidents in which the fuel salt—including any in the cover gas—has been released from the first barrier layer. This information-gathering process included identifying all potential accidents that could result in the release of a substantial amount of radionuclides that could breach or bypass the first barrier. The PIRT did not identify any previously unrecognized systemic vulnerabilities. However, the elicitation process identified several areas with low levels of knowledge and significant potential impact on accident progression. These areas either require additional research to improve the state of knowledge or additional design conservatism to accommodate the remaining unknowns.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A systematic strategy for estimating hERG block potency and its implications in a new cardiac safety paradigm

Introduction: hERG block potency is widely used to calculate a drug's safety margin against its torsadogenic potential. Previous studies are confounded by use of different patch clamp electrophysiology protocols and a lack of statistical quantification of experimental variability. Since the new cardiac safety paradigm being discussed by the International Council for Harmonisation promotes a tighter integration of nonclinical and clinical data for torsadogenic risk assessment, a more systematic approach to estimate the hERG block potency and safety margin is needed. Methods: A cross-industry study was performed to collect hERG data on 28 drugs with known torsadogenic risk using a standardized experimental protocol. A Bayesian hierarchical modeling (BHM) approach was used to assess the hERG block potency of these drugs by quantifying both the inter-site and intra-site variability. A modeling and simulation study was also done to evaluate protocol-dependent changes in hERG potency estimates. Results: A systematic approach to estimate hERG block potency is established. The impact of choosing a safety margin threshold on torsadogenic risk evaluation is explored based on the posterior distributions of hERG potency estimated by this method. The modeling and simulation results suggest any potency estimate is specific to the protocol used. Discussion: This methodology can estimate hERG block potency specific to a given voltage protocol. The relationship between safety margin thresholds and torsadogenic risk predictivity suggests the threshold should be tailored to each specific context of use, and safety margin evaluation may need to be integrated with other information to form a more comprehensive risk assessment.

60 APPLIED LIFE SCIENCES↗

Credible Criticality Safety Margin in the 30B Package with LEU+ UF 6 and Hypothetical Water Ingress

The commercial nuclear industry is pursuing advancements in fuel and reactor design that increase the uranium enrichment above 5 wt. % 235 U. These advancements will necessitate the ability to transport bulk quantities of UF 6 at increased enrichments. Currently, the 30B cylinder is the primary container used by the industry for UF6 storage and transportation and has a long history of successful shipments. This container can transport up to 2,277 kg of UF 6 at a maximum enrichment of 5 wt. % 235 U. Previous evaluations have assessed the potential impact of criticality safety for 30B transport at higher enrichments but assumed moderator intrusion would not require evaluation. Although current regulations allow for the exception of moderator intrusion for UF6 packages through the design and quality control of the package content, this exception is limited to enrichments up to 5 wt. % 235 U. Thus, an investigation of moderator intrusion into a 30B cylinder should be performed.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗