Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ridge”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Characteristics of the dynamic shielding on the Wannier-ridge electron escapes by electron impact in weakly coupled plasmas

The influence of the dynamic shielding on the Wannier ridge electron escapes into the continuum states by the electron-impact is investigated in weakly coupled plasmas. The dynamically shielded renormalized electron charge and screened Wannier exponent are obtained by considering the equation of motion in the Wannier configuration mode with the effective interaction potential as functions of the charge of the residual ion, Debye length, projectile energy, and thermal energy. The result shows that the dynamic renormalized effective electron charge decreases with an increase of the thermal energy, especially for large distances. It is found that the dynamic shielding effect enhances the Wannier exponent for the double-electron escape. The variation of the dynamic shielding effect on the screened Wannier exponent is also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Direct-bandgap electroluminescence from a horizontal Ge p-i-n ridge waveguide on Si(001) substrate

Horizontal injection Ge p-i-n ridge waveguide light emitting diodes (LEDs) were fabricated on n{sup −}-Si(001) substrates by ultrahigh vacuum chemical vapor deposition. The direct-bandgap electroluminescence (EL) of Ge waveguide LEDs under a continuous/pulse electrical pump was studied. The heating effect from a continuous electrical pump was found to significantly enhance the emission of devices. The top surface EL intensity of the Ge waveguide LEDs significantly depended on the position. Most direct-bandgap radiative recombination of Ge p-i-n waveguide LEDs occurred near the N{sup +} region of the junction. This interesting phenomenon could be explained by the carrier distribution in the junction and the pseudo-direct bandgap of Ge.

36 MATERIALS SCIENCE↗

Broadband asymmetric acoustic transmission by a plate with quasi-periodic surface ridges

In this paper, an acoustic system with broadband asymmetric transmission is designed and fabricated, which consists of a water-immersed aluminum plate engraved with quasi-periodically-patterned ridges on single surface. It demonstrates that when the acoustic waves are launched into the system from the structured side, they can couple into the Lamb modes in the plate efficiently and attain a high transmission; on the contrary, when the waves are incident from the opposite flat side, the coupling is weak, and the transmission is low. Superior to systems with periodic patterning, this quasi-periodically-patterned system has a broad working frequency range due to the collective contributions from the multiple diffractions specific to the structure.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantum dot spontaneous emission control in a ridge waveguide

We investigate the spontaneous emission (SE) of self-assembled InAs quantum dots (QDs) embedded in GaAs ridge waveguides that lay on a low index substrate. In thin enough waveguides, the coupling to the fundamental guided mode is vanishingly small. A pronounced anisotropy in the coupling to non-guided modes is then directly evidenced by normal-incidence photoluminescence polarization measurements. In this regime, a measurement of the QD decay rate reveals a SE inhibition by a factor up to 4. In larger wires, which ensure an optimal transverse confinement of the fundamental guided mode, the decay rate approaches the bulk value. Building on the good agreement with theoretical predictions, we infer from calculations the fraction β of SE coupled to the fundamental guided mode for some important QD excitonic complexes. For a charged exciton (isotropic in plane optical dipole), β reaches 0.61 at maximum for an on-axis QD. In the case of a purely transverse linear optical dipole, β increases up to 0.91. This optimal configuration is achievable through the selective excitation of one of the bright neutral excitons.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

BeZnCdSe quantum-well ridge-waveguide laser diodes under low threshold room-temperature continuous-wave operation

Low threshold current ridge-waveguide BeZnCdSe quantum-well laser diodes (LDs) have been developed by completely etching away the top p-type BeMgZnSe/ZnSe:N short-period superlattice cladding layer, which can suppress the leakage current that flows laterally outside of the electrode. The waveguide LDs are covered with a thick SiO{sub 2} layer and planarized with chemical-mechanical polishing and a reactive ion etching process. Room-temperature lasing under continuous-wave condition is achieved with the laser cavity formed by the cleaved waveguide facets coated with high-reflectivity dielectric films. For a 4 μm-wide green LD lasing around a wavelength of 535 nm, threshold current and voltage of 7.07 mA and 7.89 V are achieved for a cavity length of 300 μm, and the internal differential quantum efficiency, internal absorption loss, gain constant, and nominal transparency current density are estimated to be 27%, 4.09 cm{sup −1}, 29.92 (cm × μm)/kA and 6.35 kA/(cm{sup 2 }× μm), respectively. This compact device can realize a significantly improved performance with much lower threshold power consumption, which would benefit the potential application for ZnSe-based green LDs as light sources in full-color display and projector devices installed in consumer products such as pocket projectors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ridge InGaAs/InP multi-quantum-well selective growth in nanoscale trenches on Si (001) substrate

Metal organic chemical vapor deposition of InGaAs/InP multi-quantum-well in nanoscale V-grooved trenches on Si (001) substrate was studied using the aspect ratio trapping method. A high quality GaAs/InP buffer layer with two convex (111) B facets was selectively grown to promote the highly uniform, single-crystal ridge InP/InGaAs multi-quantum-well structure growth. Material quality was confirmed by transmission electron microscopy and room temperature micro-photoluminescence measurements. This approach shows great promise for the fabrication of photonics devices and nanolasers on Si substrate.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Renormalization shielding effect on the Wannier-ridge mode for double-electron continua in partially ionized dense hydrogen plasmas

The influence of renormalization shielding on the Wannier threshold law for the double-electron escapes by the electron-impact ionization is investigated in partially ionized dense plasmas. The renormalized electron charge and Wannier exponent are obtained by considering the equation of motion in the Wannier-ridge including the renormalization shielding effect. It is found that the renormalization shielding effect reduces the magnitude of effective electron charge, especially, within the Bohr radius in partially ionized dense plasmas. The maximum position of the renormalized electron charge approaches to the center of the target atom with an increase of the renormalization parameter. In addition, the Wannier exponent increases with an increase of the renormalization parameter. The variations of the renormalized electron charge and Wannier exponent due to the renormalization shielding effect are also discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A suite-level review of the neutron single-crystal diffraction instruments at Oak Ridge National Laboratory

The nascent suite of single-crystal neutron diffractometers at the Oak Ridge National Laboratory has no equal at any other neutron scattering facility worldwide and offers the potential to re-assert single-crystal diffraction using neutrons as a significant tool to study nuclear and magnetic structures of small unit cell crystals, nuclear structures of macromolecules, and diffuse scattering. Signature applications and features of single-crystal neutron diffraction are high resolution nuclear structure analysis, magnetic structure and spin density determinations, contrast variation (particularly D 2 O/H 2 O) for nuclear structural studies, lack of radiation damage when using crystals of biological molecules such as proteins, and the fidelity to measure nuclear and magnetic diffuse scattering with elastic discrimination.

47 OTHER INSTRUMENTATION↗

The high pressure gas capabilities at Oak Ridge National Laboratory’s neutron facilities

The study of samples subjected to high pressure gas is an important asset in materials research and has consequently been a priority of the sample environment development at the Oak Ridge National Laboratory’s (ORNL) neutron program. Such effort has resulted in the availability of an extensive combination of pressure cells and gas intensifiers (both commercially available and custom made). These resources are available across both neutron facilities at ORNL: the Spallation Neutron Source and the High Flux Isotope Reactor. Current capabilities include, for example, in situ measurements up to 6 kbar and a 3 kbar hydrogen-capable intensifier with a gas recovery feature. In this communication, we will review the existing suite of high pressure gas capabilities, with special emphasis on recent in-house developments. Finally, a number of examples will be presented to illustrate how such capabilities are being deployed on neutron beamlines to enable frontier science.

47 OTHER INSTRUMENTATION↗

A suite-level review of the neutron powder diffraction instruments at Oak Ridge National Laboratory

The suite of neutron powder diffractometers at Oak Ridge National Laboratory (ORNL) utilizes the distinct characteristics of the Spallation Neutron Source and High Flux Isotope Reactor to enable the measurements of powder samples over an unparalleled regime at a single laboratory. Full refinements over large Q ranges, total scattering methods, fast measurements under changing conditions, and a wide array of sample environments are available. Here, this article provides a brief overview of each powder instrument at ORNL and details the complementarity across the suite. Future directions for the powder suite, including upgrades and new instruments, are also discussed.

47 OTHER INSTRUMENTATION↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Combination of DGA and LN Columns: A Versatile Option for Isotope Production and Purification at Oak Ridge National Laboratory

The chromatographic resins DGA and LN have been used sequentially to separate curium, californium, plutonium, and various fission products (FPs) to obtain products with a pure radioisotope or a radioelement with high isotopic purity. This 2-step combination of resins has found applications in the 252 Cf and 238 Pu campaigns performed at Oak Ridge National Laboratory. Experiments have been carried out in glove boxes, shielded caves, and hot cells, demonstrating that these resins are adequate and maintain their performance in highly radiolytic environments. We find that using these resins has led to the recovery of curium highly enriched (>95%) in 248 Cm, the clean separation of 251 Cf for the superheavy element research, and the recovery of 147 Pm from the FP stream obtained during the 238 Pu production campaign while demonstrating that the raffinate post DGA is essentially free of transuranic elements.

07 ISOTOPE AND RADIATION SOURCES↗

Inverse Compton Origin of the Hard X-ray and Soft gamma-ray Emission from the Galactic Ridge

A recent re-determination of the non-thermal component of the hard X-ray to soft {gamma}-ray emission from the Galactic ridge, using the SPI instrument on the INTErnational Gamma-Ray Astrophysics Laboratory (INTEGRAL) Observatory, is shown to be well reproduced as inverse-Compton emission from the interstellar medium. Both cosmic-ray primary electrons and secondary electrons and positrons contribute to the emission. The prediction uses the GALPROP model and includes a new calculation of the interstellar radiation field. This may solve a long-standing mystery of the origin of this emission, and potentially opens a new window on Galactic cosmic rays.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

DESIGN AND TEST OF AN INSTRUMENT FOR MEASURING MICROTHERMAL SEEING ON THE MAGDALENA RIDGE

We have constructed and operated an automated instrument for measuring ground-level microthermal seeing at the Magdalena Ridge Observatory (MRO). The MRO is located at an altitude of 10500' in the Cibola National Forest in New Mexico, USA. It is the planned site for the MRO Optical Interferometer (MROI) planned for up to 10 collecting elements, each with a diameter of 1.4 m, and baselines eventually up to approximately 400 m. As part of the preparation for construction we deployed a system to characterize the ground-level seeing across the observatory site. The instrument is built largely of off-the-shelf components, with only the sensor head and power supply requiring electronic board assembly. Even in those cases the board architecture is very simple. The first proof-of-concept system was deployed for several weeks in the autumn of 2004, and has since undergone several iterations. The latest configuration operates entirely off batteries, incorporates wireless data acquisition, and is thus able to operate in an area with no shelter, power, or communications. In this paper we present the design of the instrument, and show initial data. The microthermal tower has four sensor pairs at heights from 0.8 to 4.41 m, significantly lower than other microthermal experiments, because of the need to characterize the seeing near the ground. We find significant variation in the contribution of this range of heights to the seeing, contributing up to 0.''3 of the seeing at some times and only 0.''02 at other times. The individual sensor power spectra have a slope in the range of 1.4--1.5, which is lower than the 1.67 slope predicted by Kolmogorov turbulence theory. We measure the well known effect of improved seeing immediately around sunset. While we find significant variation in the microthermal seeing, we did not find a pattern of corresponding variations in weather conditions, suggesting that a complicated set of factors control microthermal turbulence.

79 ASTRONOMY AND ASTROPHYSICS↗

BROADBAND SPECTRAL ANALYSIS OF THE GALACTIC RIDGE X-RAY EMISSION

Detailed spectral analysis of the Galactic X-ray background emission, or the Galactic Ridge X-ray Emission (GRXE), is presented. To study the origin of the emission, broadband and high-quality GRXE spectra were produced from 18 pointing observations with Suzaku in the Galactic bulge region, with a total exposure of 1 Ms. The spectra were successfully fitted by a sum of two major spectral components: a spectral model of magnetic accreting white dwarfs with a mass of 0.66{sup +0.09}{sub -0.07} M{sub Sun} and a softer optically thin thermal emission with a plasma temperature of 1.2-1.5 keV that is attributable to coronal X-ray sources. When combined with previous studies that employed high spatial resolution of the Chandra satellite, the present spectroscopic result gives stronger support to the scenario that the GRXE is essentially an assembly of numerous discrete faint X-ray stars. The detected GRXE flux in the hard X-ray band was used to estimate the number density of the unresolved hard X-ray sources. When integrated over a luminosity range of {approx}10{sup 30}-10{sup 34} erg s{sup -1}, the result is consistent with a value that was reported previously by directly resolving faint point sources.

79 ASTRONOMY AND ASTROPHYSICS↗

X-RAY POINT-SOURCE POPULATIONS CONSTITUTING THE GALACTIC RIDGE X-RAY EMISSION

Apparently diffuse X-ray emission has been known to exist along the central quarter of the Galactic Plane since the beginning of X-ray astronomy; this is referred to as the Galactic Ridge X-ray emission (GRXE). Recent deep X-ray observations have shown that numerous X-ray point sources account for a large fraction of the GRXE in the hard band (2-8 keV). However, the nature of these sources is poorly understood. Using the deepest X-ray observations made in the Chandra bulge field, we present the result of a coherent photometric and spectroscopic analysis of individual X-ray point sources for the purpose of constraining their nature and deriving their fractional contributions to the hard-band continuum and Fe K line emission of the GRXE. Based on the X-ray color-color diagram, we divided the point sources into three groups: A (hard), B (soft and broad spectrum), and C (soft and peaked spectrum). The group A sources are further decomposed spectrally into thermal and non-thermal sources with different fractions in different flux ranges. From their X-ray properties, we speculate that the group A non-thermal sources are mostly active galactic nuclei and the thermal sources are mostly white dwarf (WD) binaries such as magnetic and non-magnetic cataclysmic variables (CVs), pre-CVs, and symbiotic stars, whereas the group B and C sources are X-ray active stars in flares and quiescence, respectively. In the log N-log S curve of the 2-8 keV band, the group A non-thermal sources are dominant above Almost-Equal-To 10{sup -14} erg cm{sup -2} s{sup -1}, which is gradually taken over by Galactic sources in the fainter flux ranges. The Fe K{alpha} emission is mostly from the group A thermal (WD binaries) and the group B (X-ray active stars) sources.

79 ASTRONOMY AND ASTROPHYSICS↗

TOMOGRAPHY OF PLASMA FLOWS IN THE UPPER SOLAR CONVECTION ZONE USING TIME-DISTANCE INVERSION COMBINING RIDGE AND PHASE-SPEED FILTERING

The consistency of time-distance inversions for horizontal components of the plasma flow on supergranular scales in the upper solar convection zone is checked by comparing the results derived using two k-{omega} filtering procedures-ridge filtering and phase-speed filtering-commonly used in time-distance helioseismology. I show that both approaches result in similar flow estimates when finite-frequency sensitivity kernels are used. I further demonstrate that the performance of the inversion improves (in terms of a simultaneously better averaging kernel and a lower noise level) when the two approaches are combined together in one inversion. Using the combined inversion, I invert for horizontal flows in the upper 10 Mm of the solar convection zone. The flows connected with supergranulation seem to be coherent only for the top {approx}5 Mm; deeper down there is a hint of change of the convection scales toward structures larger than supergranules.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Pn magnitude scale m b ( Pn ) for earthquakes along the equatorial Mid-Atlantic Ridge

We developed a short-period Pn magnitude scale m b (Pn) for earthquakes along the equatorial Mid-Atlantic Ridge. Due to low signal-to-noise ratios, teleseismic body wave magnitude and long-period surface wave magnitude cannot be confidently determined for small earthquakes of m b < 4. Local magnitude scales are also not useful for these events because the oceanic environment does not allow the propagation of crustal phases. However, regional high-frequency Pn waves from these small- to moderate-size (m b 3–6) earthquakes are well recorded in the equatorial Atlantic region and can be used to assign magnitudes. We measured over 2041 Pn peak amplitudes on vertical records from about 21 stations in northeastern Brazil and 11 stations in western Africa in the distance range of 700–3700 km. We analysed data from 189 events from the global centroid moment tensor catalogue to tie our m b (Pn) scale to M w so that seismic moments can be readily estimated. Pn arrivals show apparent group velocity between 7.9 km s –1 at short ranges (~1000 km) and up to 9.1 km s –1 at 3500 km. The measured peak amplitudes have a frequency between 0.8 and 3 Hz at 1000–1800 km, but at greater distances, 1800–3700 km, they show a remarkably consistent frequency of about 0.8 Hz. The peak amplitude attenuates at a higher rate at short distances (~0.65 magnitude units between 700 and 2000 km) but attenuates at a lower rate at long distances (~0.35 magnitude units between 2000 and 3700 km). The low rate of amplitude decay with distance and nearly constant frequency content of the peak amplitudes suggest that Pn waves propagate efficiently in the lower part of the upper mantle in the equatorial Atlantic Ocean basins. Furthermore, these are important attributes of oceanic Pn waves that can be used to assign magnitude for small- to moderate-size earthquakes in the equatorial mid-Atlantic region. The estimated station corrections correlate well with upper mantle low-velocity anomalies, especially in Brazil.

58 GEOSCIENCES↗