Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “renewable generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Improving Unit Flexibility Utilizing Plasma Ignitors

Coal fired steam generation operators face increasing market challenges, including competition from low cost generation, renewables, and regulatory pressure. These market conditions are forcing utilities to operate their coal assets in a more flexible mode, including more frequent starts and stops, faster ramp rates, frequent cycling, and extended operation at the lowest possible loads. Without upgrades to firing and control systems, pressure parts, and auxiliary systems, CAPEX and OPEX costs will increase significantly. Typically, expensive support fuels (Oil or Gas) are required to maintain safe, stable coal ignition when operating below 25% to 35% MCR (Maximum Continuous Rating). The exact minimum load without support fuel differs depending upon unit design specifications and fuel being burned. Frequent starts also increase the use of support fuels. The firing and burner control systems must be designed to allow for proper operation over the unit’s load range, ensuring that all mechanical components operate properly, and proper control of air and fuel streams can be maintained. To address the need for frequent starts and the need for stable low load operation on coal fired steam generators, this paper discusses options available, including, Firing Systems upgrades, Digital solutions, and pressure part upgrades. Several case studies are included that highlight options available allowing units to stay in operation and reduce CAPEX and OPEX costs.

01 COAL, LIGNITE, AND PEAT↗

Demand Response Operation of Electricity-Intensive Chemical Processes for Reduced Greenhouse Gas Emissions: Application to an Air Separation Unit

A recent push for reduced greenhouse gas (GHG) emissions has led (in part) to the addition of renewable electricity generation sources to the power generation mix. Renewables such as wind and solar are desynchronized from grid demand, requiring the use of fossil fuels to bridge the gap. We propose a novel production scheduling formulation, emissions-minimizing production (EMP), which utilizes time-based information on the nature of the power generation mix to lower GHG emissions related to the transmission and generation of electricity for industrial users. We demonstrate the application of EMP on a single-column air separation unit. The scheduling problem is cast as a mixed integer linear program that can be solved in a practical amount of time. Extensive numerical studies are used to place EMP in the context of other production scheduling methods (such as demand response), and demonstrate its potential for significant reductions in GHG emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cosimulating Integrated Energy Systems With Heterogeneous Digital Twins: Matching a Connected World

Energy system integration promises in-creased resiliency and the unlocking of synergies, while also contributing to our goal of decarbonization. It is enabled by both old and new technologies, glued together with data and digital services. Hydrolyzers, heat pumps, distributed renewable generation, smart buildings, and the digital grid edge are all currently the subject of integration with the power system and the energy sector at large. To plan and operate such a multidisciplinary and multisectoral system properly, insight, tools, and expertise are all needed. Further, this is exactly where the state of the art fails to deliver: tools for integrated energy systems (IESs) are still in their infancy, and many times, even academia treats these sectors separately, producing experts in each of them but not across.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Opportunities for Industry to Provide Flexibility While Increasing Profitability

Supply and demand flexibility will both be needed to ensure the electricity system functions properly as the share from variable renewable generation continues to grow. Industrial manufacturing currently consumes about a third of primary energy worldwide, and electricity is projected to supply an increasing share of this demand as the global economy decarbonizes. Therefore, the ability for industry to flex demand poses an enticing opportunity to enable grid flexibility. However, large capital outlays prevent industry from voluntarily altering demand. Here we show that as battery costs continue to fall, industry will soon be able to profitably alter demand in accordance with electricity price variations. Focusing on two established industries– chlor-alkali and electric arc furnaces – and two industries with large future potential – methane pyrolysis and atmospheric CO 2 capture, we use a linear program (LP) optimization to assess the technoeconomic feasibility of flexible industrial demand across both historical and future-looking wholesale day-ahead marginal prices for the Electricity Reliability Council of Texas (ERCOT). We find positive net present values (NPV) from $\$$400K to $\$$50M using projected 2050 battery prices for industrial purchase of behind-the-meter batteries, using only arbitrage as a source of value. These results indicate that, with projected battery prices, profit-seeking industrial players could voluntarily play a future role in stabilizing a high-renewables grid where electricity prices act as accurate signals of grid needs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Recommended Functionalities for Improving Cybersecurity of Distributed Energy Resources

The current electric grid is transitioning through increasing penetration of distributed energy resources (DERs), which include intermittent renewable generation resources on the distribution side. Both the monitoring and control of DERs require extensive data-exchange and communication networks. These networks lead to cyber vulnerabilities and risks of new kinds of cyberattacks that may be extremely destructive for power system operations. Although current standards, such as IEEE Std. 1547-2018, do not discuss cybersecurity measures for DERs, cybersecurity controls should be developed for securing DER systems at the device level, communications level, and applications level. This paper discusses the current industry's best practices related to DER cybersecurity and proposes recommended functionalities for improving the cybersecurity posture of DERs, specifically at the device/distribution level. These practical recommendations have been discussed and verified with the industry through a DER cybersecurity working group.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Contribution of Spicules to Solar Coronal Emission

Recent high-resolution imaging and spectroscopic observations have generated renewed interest in spicules' role in explaining the hot corona. Some studies suggest that some spicules, often classified as type II, may provide significant mass and energy to the corona. Here we use numerical simulations to investigate whether such spicules can produce the observed coronal emission without any additional coronal heating agent. Model spicules consisting of a cold body and hot tip are injected into the base of a warm (0.5 MK) equilibrium loop with different tip temperatures and injection velocities. Both piston- and pressure-driven shocks are produced. We find that the hot tip cools rapidly and disappears from coronal emission lines such as Fe xii 195 and Fe xiv 274. Prolonged hot emission is produced by preexisting loop material heated by the shock and by thermal conduction from the shock. However, the shapes and Doppler shifts of synthetic line profiles show significant discrepancies with observations. Furthermore, spatially and temporally averaged intensities are extremely low, suggesting that if the observed intensities from the quiet Sun and active regions were solely due to type II spicules, one to several orders of magnitude more spicules would be required than have been reported in the literature. This conclusion applies strictly to the ejected spicular material. We make no claims about emissions connected with waves or coronal currents that may be generated during the ejection process and heat the surrounding area.

Shanwlee Sow Mondal↗

Recommended Functionalities for Improving Cybersecurity of Distributed Energy Resources: Preprint

The legacy electric grid is transitioning into a 'present' modern grid due to increasing penetration of intermittent renewable generation at the distribution side, also known as distributed energy resources (DERs). Monitoring and control of such DERs requires extensive data-exchange and bidirectional communication networks. This bidirectional communication paves the way to cyber vulnerabilities and risks for new kinds of cyber-attacks that may have destructive impacts on power system operations. Since IEEE Std. 1547-2018 does not discuss cybersecurity measures for DERs, cybersecurity controls should be developed for securing DER systems at all three levels: device level, communications level, and applications level. This paper discusses the current industry's best practices related to DER cybersecurity and proposes recommended functionalities for improving the cybersecurity posture of DERs. These practical recommended functionalities have been discussed and verified with the industry through a DER cybersecurity working group and are meant to improve the device level security of DERs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Site demonstration and performance evaluation of MPC for a large chiller plant with TES for renewable energy integration and grid decarbonization

Thermal energy storage (TES) for a cooling plant is a crucial resource for load flexibility. Traditionally, simple, heuristic control approaches, such as the storage priority control which charges TES during the nighttime and discharges during the daytime, have been widely used in practice, and shown reasonable performance in the past benefiting both the grid and the end-users such as buildings and district energy systems. However, the increasing penetration of renewables changes the situation, exposing the grid to a growing duck curve, which encourages the consumption of more energy in the daytime, and volatile renewable generation which requires dynamic planning. The growing pressure of diminishing greenhouse gas emissions also increases the complexity of cooling TES plant operations as different control strategies may apply to optimize operations for energy cost or carbon emissions. This paper presents a model predictive control (MPC), site demonstration and evaluation results of optimal operation of a chiller plant, TES and behind-meter photovoltaics for a campus-level district cooling system. The MPC was formulated as a mixed-integer linear program for better numerical and control properties. Compared with baseline rule-based controls, the MPC results show reductions of the excess PV power by around 25%, of the greenhouse gas emission by 10%, and of peak electricity demand by 10%.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Digital Real-Time Simulation and Power Quality Analysis of a Hydrogen-Generating Nuclear-Renewable Integrated Energy System

This paper investigates the challenges and solutions associated with integrating a hydrogen-generating nuclear-renewable integrated energy system (NR-IES) under a transactive energy framework. The proposed system directs excess nuclear power to hydrogen production during periods of low grid demand while utilizing renewables to maintain grid stability. Using digital real-time simulation (DRTS) in the Typhoon HIL 404 model, the dynamic interactions between nuclear power plants, electrolyzers, and power grids are analyzed to mitigate issues such as harmonic distortion, power quality degradation, and low power factor caused by large non-linear loads. A three-phase power conversion system is modeled using the Typhoon HIL 404 model and includes a generator, a variable load, an electrolyzer, and power filters. Active harmonic filters (AHFs) and hybrid active power filters (HAPFs) are implemented to address harmonic mitigation and reactive power compensation. The results reveal that the HAPF topology effectively balances cost efficiency and performance and significantly reduces active filter current requirements compared to AHF-only systems. During maximum electrolyzer operation at 4 MW, the grid frequency dropped below 59.3 Hz without filtering; however, the implementation of power filters successfully restored the frequency to 59.9 Hz, demonstrating its effectiveness in maintaining grid stability. Future work will focus on integrating a deep reinforcement learning (DRL) framework with real-time simulation and optimizing real-time power dispatch, thus enabling a scalable, efficient NR-IES for sustainable energy markets.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Economic optimization of operations for hybrid energy systems under variable markets

We prosed a hybrid energy systems (HES) which is an important element to enable increasing penetration of clean energy. Our paper investigates the operations flexibility of HES, and develops a methodology for operations optimization for maximizing economic value based on predicted renewable generation and market information. A multi-environment computational platform for performing such operations optimization is also developed. In order to compensate for prediction error, a control strategy is accordingly designed to operate a standby energy storage element (ESE) to avoid energy imbalance within HES. The proposed operations optimizer allows systematic control of energy conversion for maximal economic value. Simulation results of two specific HES configurations are included to illustrate the proposed methodology and computational capability. These results demonstrate the economic viability of HES under proposed operations optimizer, suggesting the diversion of energy for alternative energy output while participating in the ancillary service market. Economic advantages of such operations optimizer and associated flexible operations are illustrated by comparing the economic performance of flexible operations against that of constant operations. Sensitivity analysis with respect to market variability and prediction error, are also performed.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Review and Future Perspective of Central Receiver Design and Performance

Concentrating solar power (CSP) technology provides a commercial solar option to the utility-scale electricity market. CSP is unique in its ability to include low-cost thermal storage; thus, it can generate electricity when the sun is not available and dispatch electricity to meet varying load requirements. Within the suite of CSP technologies, the central receiver design represents the state-of-the-art technology, promising low cost, high performance, and dispatchable energy production. Current total capacity of central receiver plants worldwide is about 1.0 gigawatt (electric) with operating plants in Spain and the United States, as well as projects under construction in Asia, the Middle East, and North Africa. Central receiver technology has been under development since the 1950s, and a variety of central receiver designs have been explored. A distinguishing feature is the heat transfer medium. Central receiver designs exist that use dense fluids, gases, and solid particles in this role. Water/steam and molten salt receivers have been adopted in current commercial plants and are often coupled with a steam-Rankine power cycle with an operating temperature of less than 600 degrees C. Many new central receiver concepts, such as the volumetric air, supercritical carbon dioxide (sCO2), solid particle, and liquid-metal receiver designs, are under active research and development (R&D). New designs target operating temperatures generally higher than 700 degrees C-800 degrees C -- and even above 1000 degrees C -- so that higher-performance power cycles such as the sCO2-Brayton cycle or air-Brayton/steam-Rankine combined cycle can be used to promote greater overall system efficiency. Central receiver thermal storage provides dispatchability unavailable from variable-output renewables such as solar photovoltaic and wind power. Case study analysis of the California grid shows that there is a limit on the amount of non-dispatchable renewable generation that the grid can accommodate, beyond which overgeneration, spillage, and instability may occur. Energy storage may well become a necessity in some areas in order to maintain reliability. Next-generation central receiver technologies will have higher operating temperatures and additional features that allow higher-efficiency power generation and deliver other cost-performance advantages. The underlying innovations will come from areas such as multi-physics modeling, high-temperature materials, novel power cycles and heat exchanger designs, and collector field sensing and performance monitoring technologies. Technology innovation is expected to improve the cost and performance of central receiver designs. To deliver value as a generation and storage option, central receiver technology must also be supported by flexible and robust financial models and comprehensive energy and ancillary service markets justifying the capital-intensive investment. Progress in these areas will position CSP central receiver technology for future deployment.

14 SOLAR ENERGY↗

Overcoming Barriers Associated with Oral Delivery of Differently Sized Fluorescent Core‐Shell Silica Nanoparticles

Oral delivery, while a highly desirable form of nanoparticle-drug administration, is limited by challenges associated with overcoming several biological barriers. Here, in this study, the authors study how fluorescent and poly(ethylene glycol)-coated (PEGylated) core-shell silica nanoparticles sized 5 to 50 nm interact with major barriers including intestinal mucus, intestinal epithelium, and stomach acid. From imaging fluorescence correlation spectroscopy studies using quasi-total internal reflection fluorescence microscopy, diffusion of nanoparticles through highly scattering mucus is progressively hindered above a critical hydrodynamic size around 20 nm. By studying Caco-2 cell monolayers mimicking the intestinal epithelia, it is observed that ultrasmall nanoparticles below 10 nm diameter (Cornell prime dots, [C’ dots]) show permeabilities correlated with high absorption in humans from primarily enhanced passive passage through tight junctions. Particles above 20 nm diameter exclusively show active transport through cells. After establishing C’ dot stability in artificial gastric juice, in vivo oral gavage experiments in mice demonstrate successful passage through the body followed by renal clearance without protein corona formation. Results suggest C’ dots as viable candidates for oral administration to patients with a proven pathway towards clinical translation and may generate renewed interest in examining silica as a food additive and its effects on nutrition and health.

36 MATERIALS SCIENCE↗

Exploring the Interface of Skin-Layered Titanium Fibers for Electrochemical Water Splitting

Water electrolysis is the key to a decarbonized energy system, as it enables the conversion and storage of renewably generated intermittent electricity in the form of hydrogen. However, reliability challenges arising from titanium-based porous transport layers (PTLs) have hitherto restricted the deployment of next-generation water-splitting devices. Here, it is shown for the first time how PTLs can be adapted so that their interface remains well protected and resistant to corrosion across ˜4000 h under real electrolysis conditions. It is also demonstrated that the malfunctioning of unprotected PTLs is a result triggered by additional fatal degradation mechanisms over the anodic catalyst layer beyond the impacts expected from iridium oxide stability. Now, superior durability and efficiency in water electrolyzers can be achieved over extended periods of operation with less-expensive PTLs with proper protection, which can be explained by the detailed reconstruction of the interface between the different elements, materials, layers, and components presented in this work.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Biosensor Discriminates Between Different Algal H 2 -Photoproducing Strains

A number of species of microalgae and cyanobacteria photosynthetically produce H 2 gas by coupling water oxidation with the reduction of protons to molecular hydrogen, generating renewable energy from sunlight and water. Photosynthetic H 2 production, however, is transitory, and there is considerable interest in increasing and extending it for commercial applications. Here we report a Petri-plate version of our previous, microplate-based assay that detects photosynthetic H 2 production by algae. The assay consists of an agar overlay of H 2 -sensing Rhodobacter capsulatus bacteria carrying a green fluorescent protein that responds to H 2 produced by single algal colonies in the bottom agar layer. The assay distinguishes between algal strains that photoproduce H 2 at different levels under high light intensities, and it does so in a simple, inexpensive, and high-throughput manner. The assay will be useful for screening both natural populations and mutant libraries for strains having increased H 2 production, and useful for identifying various genetic factors that physiologically or genetically alter algal hydrogen production.

08 HYDROGEN↗

D 3 -creatine dilution for skeletal muscle mass measurement: historical development and current status

The French chemist Michel Eugène Chevreul discovered creatine in meat two centuries ago. Extensive biochemical and physiological studies of this organic molecule followed with confirmation that creatine is found within the cytoplasm and mitochondria of human skeletal muscles. Two groups of investigators exploited these relationships five decades ago by first estimating the creatine pool size in vivo with 14 C and 15 N labelled isotopes. Skeletal muscle mass (kg) was then calculated by dividing the creatine pool size (g) by muscle creatine concentration (g/kg) measured on a single muscle biopsy or estimated from the literature. This approach for quantifying skeletal muscle mass is generating renewed interest with the recent introduction of a practical stable isotope (creatine-(methyl-d 3 )) dilution method for estimating the creatine pool size across the full human lifespan. The need for a muscle biopsy has been eliminated by assuming a constant value for whole-body skeletal muscle creatine concentration of 4.3 g/kg wet weight. The current single compartment model of estimating creatine pool size and skeletal muscle mass rests on four main assumptions: tracer absorption is complete; tracer is all retained; tracer is distributed solely in skeletal muscle; and skeletal muscle creatine concentration is known and constant. Three of these assumptions are false to varying degrees. Not all tracer is retained with urinary isotope losses ranging from 0% to 9%; an empirical equation requiring further validation is used to correct for spillage. Not all tracer is distributed in skeletal muscle with non-muscle creatine sources ranging from 2% to 10% with a definitive value lacking. Lastly, skeletal muscle creatine concentration is not constant and varies between muscles (e.g. 3.89–4.62 g/kg), with diets (e.g. vegetarian and omnivore), across age groups (e.g. middle-age, ~4.5 g/kg; old-age, 4.0 g/kg), activity levels (e.g. athletes, ~5 g/kg) and in disease states (e.g. muscular dystrophies, <3 g/kg). Some of the variability in skeletal muscle creatine concentrations can be attributed to heterogeneity in the proportions of wet skeletal muscle as myofibres, connective tissues, and fat. These observations raise serious concerns regarding the accuracy of the deuterated-creatine dilution method for estimating total body skeletal muscle mass as now defined by cadaver analyses of whole wet tissues and in vivo approaches such as magnetic resonance imaging. A new framework is needed in thinking about how this potentially valuable method for measuring the creatine pool size in vivo can be used in the future to study skeletal muscle biology in health and disease.

body composition↗

Is $50/MWh solar for real? Falling project prices and rising capacity factors drive utility-scale PV toward economic competitiveness

Recently announced low-priced power purchase agreements (PPAs) for US utility-scale photovoltaic (PV) projects suggest $50/MWh solar might be viable under certain conditions. To explore this possibility, this paper draws on an increasing wealth of empirical data to analyze trends in three of the most important PPA price drivers: upfront installed project prices, operations, and maintenance (O&M) costs, and capacity factors. Average installed prices among a sample of utility-scale PV projects declined by more than one third (from 5.8/W AC to 3.7/WAC) from the 2007–2009 period through 2013, even as costlier systems with crystalline-silicon modules, sun tracking, and higher inverter loading ratios (ILRs) have constituted an increasing proportion of total utility-scale PV capacity (all values shown here are in 2013 dollars). Actual and projected O&M costs from a very small sample of projects appear to range from $20–$40/kW AC -year. Furthermore, the average net capacity factor is 30% for projects installed in 2012, up from 24% for projects installed in 2010, owing to better solar resources, higher ILRs, and greater use of tracking among the more recent projects. Based on these trends, a pro-forma financial model suggests that $50/MWh utility-scale PV is achievable using a combination of aggressive-but-achievable technical and financial input parameters (including receipt of the 30% federal investment tax credit). Although the US utility-scale PV market is still young, the rapid progress in the key metrics documented in this paper has made PV a viable competitor against other utility-scale renewable generators, and even conventional peaking generators, in certain regions of the country.

14 SOLAR ENERGY↗

Simulating dispatchable grid services provided by flexible building loads: State of the art and needed building energy modeling improvements

End-use electrical loads in residential and commercial buildings are evolving into flexible and cost-effective resources to improve electric grid reliability, reduce costs, and support increased hosting of distributed renewable generation. This article reviews the simulation of utility services delivered by buildings for the purpose of electric grid operational modeling. We consider services delivered to (1) the high-voltage bulk power system through the coordinated action of many, distributed building loads working together, and (2) targeted support provided to the operation of low-voltage electric distribution grids. Although an exhaustive exploration is not possible, we emphasize the ancillary services and voltage management buildings can provide and summarize the gaps in our ability to simulate them with traditional building energy modeling (BEM) tools, suggesting pathways for future research and development.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗