Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “reflectometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Sputtering yields of Ru, Mo, and Si under low energy Ar{sup +} bombardment

Ion sputtering yields for Ru, Mo, and Si under Ar{sup +} ion bombardment in the near-threshold energy range have been studied using an in situ weight-loss method with a Kaufman ion source, Faraday cup, and quartz crystal microbalance. The results are compared to theoretical models. The accuracy of the in situ weight-loss method was verified by thickness-decrease measurements using grazing incidence x-ray reflectometry, and results from both methods are in good agreement. These results provide accurate data sets for theoretical modeling in the near-threshold sputter regime and are of relevance for (optical) surfaces exposed to plasmas, as, for instance, in extreme ultraviolet photolithography.

36 MATERIALS SCIENCE↗

Validation of the paraxial beam-tracing method in critical cases

Paraxial Wentzel-Kramers-Brillouin (WKB) (beam-tracing) solutions of a scalar wave equation are compared to the exact solutions for the two important cases of reflection from a plasma with linearly increasing density and of oblique propagation in the presence of an absorbing half plane. In these situations, the beam-tracing technique is close to its limits of validity, yet these conditions are often met in practical applications. More specifically, the first case is relevant to reflectometry diagnostics, whereas the second case models the absorption of electron-cyclotron beams obliquely launched onto the resonance layer, as envisaged, for instance, for the ITER upper launcher [M. A. Henderson et al., Nucl. Fusion 48, 054013 (2008)]. In both cases, the beam-tracing approach is found to reproduce well the exact behavior of the wave for experimentally relevant parameters, confirming the robustness of WKB-based techniques close to or even beyond their range of applicability. For the latter case, moreover, the analysis presented here allows an evaluation of the reflection of part of the beam by the steep gradients of the absorption coefficient at the resonance layer, our results yielding an upper bound on the amount of reflected power.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A molecular beam epitaxy facility for in situ neutron scattering

A molecular beam epitaxy (MBE) facility has been built to enable in situ neutron scattering measurements during growth of epitaxial layers. While retaining the full capabilities of a research MBE chamber, this facility has been optimized for polarized neutron reflectometry measurements. Optimization includes a compact lightweight portable design, a neutron window, controllable magnetic field, deposition across a large 76 mm diameter sample with exceptional flux uniformity, and sample temperatures continuously controllable from 38 to 1375 K. A load lock chamber allows for sample insertion, storage of up to 4 samples, and docking with other facilities. The design and performance of this chamber are described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Induced ferromagnetism in Mn{sub 3}N{sub 2} phase embedded in Mn/Si{sub 3}N{sub 4} multilayers

Room temperature ferromagnetism has been obtained for different sets of Mn/Si{sub 3}N{sub 4} multilayers prepared by sputtering. In order to find the most suitable conditions to stabilize the ferromagnetic ordering in this system, the evolution of the magnetic properties has been studied for films in which the Si{sub 3}N{sub 4} layer thickness was maintained constant while that of the Mn layer was varied, [Mn(t{sub m})/Si{sub 3}N{sub 4}(3.4 nm)]{sub n}, and conversely, in [Mn(0.7 nm)/Si{sub 3}N{sub 4}(t{sub sn})]{sub 43} samples, in which the Mn layer thickness was kept constant while varying the Si{sub 3}N{sub 4} layer thickness. Structural, compositional, electronic and magnetic characterizations have been performed by means of x-ray reflectometry, Rutherford backscattering spectrometry, x-ray photoemission spectroscopy, x-ray absorption, and superconducting quantum interference device for further knowledge of the magnetic-structural relationship in this system. Our results show that the peculiar magnetic behavior of these films is mainly related to the stabilization of a slightly distorted Mn{sub 3}N{sub 2} phase that is induced by the Si{sub 3}N{sub 4} at the interfaces. For samples with larger Mn layer thickness, metallic Mn and Mn{sub 3}N{sub 2} phases coexist, which leads to a reduction of the total magnetization per Mn atom due to the presence of metallic Mn. For small Mn layer thickness (t{sub m}<0.86 nm), where noncontinuous Mn{sub 3}N{sub 2} layers are formed, the magnetization decreases noticeably due to the superparamagnetic size limit. It has been found that the best conditions for the stabilization of the ferromagnetism in this system occur when both, the manganese-rich and the silicon nitride layers, are continuous and with similar thickness, close to 3.5 nm.

36 MATERIALS SCIENCE↗

Validation of the beam tracing method for heating and diagnostics

The beam tracing approximate description of the propagation and absorption of wave beams is studied and compared to the corresponding exact solution of the wave equation for two simplified models relevant to electron cyclotron resonance heating and reflectometry diagnostics.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Periodic magnetic field as a polarized and focusing thermal neutron spectrometer and monochromator

A novel periodic magnetic field (PMF) optic is shown to act as a prism, lens, and polarizer for neutrons and particles with a magnetic dipole moment. The PMF has a two-dimensional field in the axial direction of neutron propagation. The PMF alternating magnetic field polarity provides strong gradients that cause separation of neutrons by wavelength axially and by spin state transversely. The spin-up neutrons exit the PMF with their magnetic spins aligned parallel to the PMF magnetic field, and are deflected upward and line focus at a fixed vertical height, proportional to the PMF period, at a downstream focal distance that increases with neutron energy. The PMF has no attenuation by absorption or scatter, as with material prisms or crystal monochromators. Embodiments of the PMF include neutron spectrometer or monochromator, and applications include neutron small angle scattering, crystallography, residual stress analysis, cross section measurements, and reflectometry. Presented are theory, experimental results, computer simulation, applications of the PMF, and comparison of its performance to Stern-Gerlach gradient devices and compound material and magnetic refractive prisms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the Metrology Light Source

The Physikalisch-Technische Bundesanstalt (PTB), the German national metrology institute, has set up the low-energy electron storage ring Metrology Light Source (MLS) in close cooperation with the Helmholtz-Zentrum Berlin (HZB, formerly BESSY). This new storage ring has been in regular user operation since April 2008 and is dedicated to synchrotron-radiation-based metrology and technological developments in the far-IR/THz, IR, UV, VUV and EUV spectral range. The MLS has a double-bend-achromate lattice structure, injection is from a 105 MeV racetrack microtron. The electron energy can be ramped to any value from 105 MeV up to 630 MeV and the electron beam current covers the range from one stored electron (1 pA) up to 200 mA. The MLS is the first electron storage ring optimized for the generation of coherent synchrotron radiation, based on an electron bunch shortening mode. In this mode, MLS delivers coherent radiation in the far-IR/THz spectral range with enhanced intensity as compared to the normal mode of operation. Several beamlines are in operation or in construction, including one undulator beamline, bending magnet beamlines for the calibration of radiation sources and detectors and for reflectometry, an EUV metrology beamline and three IR/THz beamlines.

43 PARTICLE ACCELERATORS↗

Single-layer mirrors for advanced research light sources

X-ray mirrors are needed for beam guidance, beam alignment and monochromatisation at third-generation synchrotron light sources (PETRA III) and forthcoming Free-Electron Lasers (LCLS, European XFEL). Amorphous carbon coatings are currently used as total reflection mirrors at FLASH to guide the photon beam to the various beamlines. These coatings were prepared by means of magnetron sputtering. The new GKSS sputtering facility for the deposition of single and multilayer mirrors with a length of up to 1500 mm and a width of up to 120 mm is in operation. In this contribution we present the results of this new deposition system. A major advantage is that it is now possible to prepare one, two or more mirrors with similar properties over the whole deposition length. The mirror properties were investigated by means of X-ray reflectometry and interference microscopy. The performance of the mirrors is analyzed, considering X-ray reflectivity, film thickness and surface roughness. The uniformity of these properties over the whole deposition length of 1500 mm is demonstrated. The results obtained will be discussed and compared with former results.

43 PARTICLE ACCELERATORS↗

New plasma measurements with a multichannel millimeter-wave fluctuation diagnostic system in the DIII-D tokamak (invited)

A novel multichannel, tunable Doppler backscattering (DBS)/reflectometry system has recently been developed and applied to a variety of DIII-D plasmas. Either DBS or reflectometry can be easily configured for use in a wide range of plasma conditions using a flexible quasi-optical antenna system. The multiple closely spaced channels, when combined with other fluctuation diagnostic systems, have opened up new measurements of plasma properties. For example, the toroidal and fine-scale radial structure of coherent plasma oscillations, such as geodesic acoustic modes, have been probed simultaneously in the core of high temperature plasmas by applying correlation analysis between two toroidally separated DBS systems, as well as within the multichannel array. When configured as a reflectometer, cross-correlation with electron cyclotron emission radiometry has uncovered detailed information regarding the crossphase relationship between density and temperature fluctuations. The density-temperature crossphase measurement yields insight into the physics of tokamak turbulence at a fundamental level that can be directly compared with predictions from nonlinear gyrokinetic simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Antenna development for high field plasma imaging

Electron cyclotron emission imaging (ECEI) and microwave imaging reflectometry (MIR) are two microwave nonperturbing plasma visualization techniques that employ millimeter-wave imaging arrays with lens-coupled planar antennas, yielding time-resolved images of temperature (via ECEI) and electron density (via MIR) fluctuations within high temperature magnetic fusion plasmas. A series of new planar antennas have been developed that extend this technology to frequencies as high as 220 GHz for use on high field plasma devices with toroidal fields in excess of 3 T. Antenna designs are presented together with theoretical calculations, simulations, and experimental measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization studies of the ITER low field side reflectometer

Microwave reflectometry will be used on ITER to measure the electron density profile, density fluctuations due to MHD/turbulence, edge localized mode (ELM) density transients, and as an L-H transition monitor. The ITER low field side reflectometer system will measure both core and edge quantities using multiple antenna arrays spanning frequency ranges of 15-155 GHz for the O-mode system and 55-220 GHz for the X-mode system. Optimization studies using the GENRAY ray-tracing code have been done for edge and core measurements. The reflectometer launchers will utilize the HE11 mode launched from circular corrugated waveguide. The launched beams are assumed to be Gaussian with a beam waist diameter of 0.643 times the waveguide diameter. Optimum launcher size and placement are investigated by computing the antenna coupling between launchers, assuming the launched and received beams have a Gaussian beam pattern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative study between the reflective optics and lens based system for microwave imaging system on KSTAR

Recently, two-dimensional microwave imaging diagnostics such as the electron cyclotron emission imaging (ECEI) system and microwave imaging reflectometry (MIR) have been developed to study magnetohydrodynamics instabilities and turbulence in magnetically confined plasmas. These imaging systems utilize large optics to collect passive emission or reflected radiation. The design of this optics can be classified into two different types: reflective or refractive optical systems. For instance, an ECEI/MIR system on the TEXTOR tokamak [Park et al., Rev. Sci. Instrum. 75, 3787 (2004)] employed the reflective optics which consisted of two large mirrors, while the TEXTOR ECEI upgrade [B. Tobias et al., Rev. Sci. Instrum. 80, 093502 (2009)] and systems on DIII-D, ASDEX-U, and KSTAR adopted refractive systems. Each system has advantages and disadvantages in the standing wave problem and optical aberrations. In this paper, a comparative study between the two optical systems has been performed in order to design a MIR system for KSTAR.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of electron cyclotron emission imaging system on Large Helical Device

A combined system of microwave imaging reflectometry and electron cyclotron emission (ECE) imaging has been developed for the Large Helical Device. This system includes a wide-band two-dimensional horn-antenna mixer array (HMA). The HMA consists of horn antennas, waveguides, mixers, and intermediate frequency circuits. The frequency response of the HMA is between 50 and 110 GHz. The ECE signal is selected using a 95 GHz local oscillator and a 93 GHz high-pass filter.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and application of setup for ac magnetic field in neutron scattering experiments

We report on a new setup developed for neutron scattering experiments in periodically alternating magnetic fields at the sample position. The assembly consisting of rf generator, amplifier, wide band transformer, and resonance circuit. It allows to generate homogeneous ac magnetic fields over a volume of a few cm{sup 3} and variable within a wide range of amplitudes and frequencies. The applicability of the device is exemplified by ac polarized neutron reflectometry (PNR): a new method established to probe remagnetization kinetics in soft ferromagnetic films. Test experiments with iron films demonstrate that the ac field within the accessible range of frequencies and amplitudes produces a dramatic effect on the PNR signal. This shows that the relevant ac field parameters generated by the device match well with the scales involved in the remagnetization processes. Other possible applications of the rf unit are briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time and space resolved interferometry for laser-generated fast electron measurements

A technique developed to measure in time and space the dynamics of the electron populations resulting from the irradiation of thin solids by ultraintense lasers is presented. It is a phase reflectometry technique that uses an optical probe beam reflecting off the target rear surface. The phase of the probe beam is sensitive to both laser-produced fast electrons of low-density streaming into vacuum and warm solid density electrons that are heated by the fast electrons. A time and space resolved interferometer allows to recover the phase of the probe beam sampling the target. The entire diagnostic is computationally modeled by calculating the probe beam phase when propagating through plasma density profiles originating from numerical calculations of plasma expansion. Matching the modeling to the experimental measurements allows retrieving the initial electron density and temperature of both populations locally at the target surface with very high temporal and spatial resolution ({approx}4 ps,6 {mu}m). Limitations and approximations of the diagnostic are discussed and analyzed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improved epitaxy of ultrathin praseodymia films on chlorine passivated Si(111) reducing silicate interface formation

Ultrathin praseodymia films have been deposited on both Cl-passivated and nonpassivated Si(111) substrates by molecular beam epitaxy. Comparative studies on the crystallinity and stoichiometry are performed by x-ray photoelectron spectroscopy, x-ray standing waves, and x-ray reflectometry. On nonpassivated Si(111) an amorphous silicate film is formed. In contrast, praseodymia deposited on Cl-passivated Si(111) form a well-ordered crystalline film with cubic-Pr{sub 2}O{sub 3} (bixbyite) structure. The vertical lattice constant of the praseodymia film is increased by 1.4% compared to the bulk value. Furthermore, the formation of an extended amorphous silicate interface layers is suppressed and confined to only one monolayer.

36 MATERIALS SCIENCE↗

Measurements and Modeling of Turbulent Transport in the Tore Supra Tokamak

This paper presents an overview of recent advances in modeling and measurements of turbulence in Tore Supra plasmas. Spatio-temporal properties of turbulence are discussed in relation with transport models. An explanation is proposed for the k{sup -3} decay of wave number spectra, which are observed by using both coherent laser scattering and Doppler reflectometry. Also the interplay between turbulence and flows has been investigated. It is shown that toroidal rotation results from a competition between neoclassical and turbulence flow generation. Finally a new method has been proposed to determine the transport coefficients of impurities. These coefficients are usually well above the neoclassical prediction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nitrogen self-diffusion in magnetron sputtered Si-C-N films

Self-diffusion was studied in magnetron sputtered nitrogen-rich amorphous compounds of the system Si-C-N by using nitrogen as a model tracer. As shown by infra-red spectroscopy a transient metastable region exists, where the structure of the material can be visualized as silicon nitride tetrahedra which are connected by carbo-diimide (-N=C=N-) bonds to a three dimensional amorphous network. In this region diffusion studies are carried out by neutron reflectometry and isotope multilayers as a function of annealing time, temperature and chemical composition. Low diffusivities between 10{sup -20} and 10{sup -24} m{sup 2}/s were found. In the metastable region, diffusion is faster than diffusion in amorphous silicon nitride by 1 to 2 orders of magnitude, while the activation enthalpies of diffusion between 3.1 and 3.4 eV are the same within error limits. This can be explained by the fact that the diffusion mechanism along SiN{sub 4} tetrahedra is identical to that in amorphous silicon nitride, however, the carbo-diimide bonds seem to widen the structure, allowing faster diffusion. A correlation between diffusivities and the number of carbo-diimid bonds present in the material is found, where the highest diffusivities are observed for materials with the highest number of carbo-diimid bonds, close to the composition Si{sub 2}CN{sub 4}.

36 MATERIALS SCIENCE↗