Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “receivers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Experimental Evaluation of the "Polished Panel Optical Receiver" Concept on the Deep Space Network's 34 Meter Antenna

The potential development of large aperture ground-based "photon bucket" optical receivers for deep space communications has received considerable attention recently. One approach currently under investigation proposes to polish the aluminum reflector panels of 34-meter microwave antennas to high reflectance, and accept the relatively large spotsize generated by even state-of-the-art polished aluminum panels. Here we describe the experimental effort currently underway at the Deep Space Network (DSN) Goldstone Communications Complex in California, to test and verify these concepts in a realistic operational environment. A custom designed aluminum panel has been mounted on the 34 meter research antenna at Deep-Space Station 13 (DSS-13), and a remotely controlled CCD camera with a large CCD sensor in a weather-proof container has been installed next to the subreflector, pointed directly at the custom polished panel. Using the planet Jupiter as the optical point-source, the point-spread function (PSF) generated by the polished panel has been characterized, the array data processed to determine the center of the intensity distribution, and expected communications performance of the proposed polished panel optical receiver has been evaluated.

photon counting detection↗

Design of a K/Q-band Beacon Receiver for the Alphasat TDP#5 Experiment

This paper describes the design and performance of a coherent K/Q-band (20/40GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload #5 (TDP#5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58dB at 1Hz and better than 48dB at 10Hz rates.

beacon receiver↗

Design of a K/Q-Band Beacon Receiver for the Alphasat Technology Demonstration Payload (TDP) #5 Experiment

This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

rain fade↗

Design of a K/Q-Band Beacon Receiver for the Alphasat TDP#5 Experiment

This paper describes the design and performance of a coherent KQ-band (2040 GHz) beacon receiver developed at NASA Glenn Research Center (GRC) that will be installed at the Politecnico di Milano (POLIMI) for use in the Alphasat Technology Demonstration Payload 5 (TDP5) beacon experiment. The goal of this experiment is to characterize rain fade attenuation at 40 GHz to improve the performance of existing statistical rain attenuation models in the Q-band. The ground terminal developed by NASA GRC utilizes an FFT-based frequency estimation receiver capable of characterizing total path attenuation effects due to gaseous absorption, clouds, rain, and scintillation. The receiver system has been characterized in the lab and demonstrates a system dynamic range performance of better than 58 dB at 1 Hz and better than 48 dB at 10 Hz rates.

beacon receiver↗

Single-mode Fiber and Few-Mode Fiber Photonic Lanterns Performance Evaluated for Use in a Scalable Real-Time Photon Counting Ground Receiver

Photonic lanterns provide an efficient way of coupling light from a single large-core fiber to multiple small-core fibers. This capability is of interest for space to ground communication applications. In these applications, the optical ground receivers require high-efficiency coupling from an atmospherically distorted focus spot to multiple fiber coupled single pixel super-conducting nanowire detectors. This paper will explore the use of photonic lanterns in a real-time ground receiver that is scalable and constructed with commercial parts. The number of small-core fibers that make a photonic lantern determines the number of spatial modes that they couple. For instance, lanterns made with n number of single-mode fibers can couple n number of spatial modes. Although the laser transmitted from a spacecraft originates as a Gaussian shape, the atmosphere distorts the beam profile by scattering energy into higher-order spatial modes. Therefore, if a ground receiver is sized for a target data rate with n number of detectors, the corresponding lantern made with single-mode fibers will couple n number of spatial modes. The energy of the transmitted beam scattered into spatial modes higher than n will be lost. This paper shows this loss may be reduced by making lanterns with few-mode fibers instead of single-mode fibers, increasing the number of spatial modes that can be coupled and therefore increasing the coupling efficiency to single pixel, single photon detectors. The free space to fiber coupling efficiency of these two types of photonic lanterns are compared over a range of the free-space coupling numerical apertures and mode field diameters. Results indicate the few mode fiber lantern has higher coupling efficiency for telescopes with longer focal lengths under higher turbulent conditions. Also presented is analysis of the jitter added to the system by the lanterns, showing the few-mode fiber photonic lantern adds more jitter than the single-mode fiber lantern, but less than a multimode fiber.

photon counting↗

NavCube3-mini Lunar GNSS Receiver

This paper describes development and testing of NASA Goddard Space Flight Center’s new NavCube3-mini (NC3m) spaceborne, weak-signal GNSS receiver, which targets all Earth orbit regimes with special focus on lunar applications. NC3m derives from the ground-breaking Magnetospheric Multiscale (MMS) mission Navigator GPS receiver. The MMS-Navigator (launched 2015) holds a Guinness World Record for highest altitude GPS fix and is currently in a highly elliptic orbit with a 29 Earth radii apogee, nearly half lunar distance. NC3m has reduced size, weight, and power compared to the MMS-Navigator, making it suitable for smallsat applications, and adds multi-frequency and multi-GNSS capabilities, among other improvements. A NC3m engineering test unit was subjected to and successfully completed a comprehensive Technology Readiness Level 6 (system/subsystem model or prototype demonstration in a relevant environment) testing campaign in the second half of 2022. This involved high-fidelity simulations in LEO, GEO, and lunar regimes and full environmental testing, including vibration, thermal vacuum, and electromagnetic compatibility. An overview of the NC3m receiver, the test setup, and a sample of results is presented. The results include predicted performance at high-altitude and in the lunar regime.

NavCube3↗

Field-Programmable Gate Array Implementation of a Single Photon-Counting Receive Modem

We present a field-programmable gate array (FPGA) implementation of a single photon-counting receive modem for a pulse position modulated signal. The modem is compliant with the Consultative Committee for Space Data Systems (CCSDS) High Photon Efficiency (HPE) Optical Communications Coding and Synchronization standard and is capable of a maximum data rate of 267 Mbps. The system is designed on a commercial off-the-shelf FPGA platform and utilizes superconducting nanowire single photon counting detectors, analog to digital converters (ADC s) to sample the detectors, and two FPGAs. Symbol timing recovery, photon counting, convolutional deinterleaving, and codeword synchronization areis performed in the first FPGA. The second FPGA performs iterative decoding on each codeword of the serially concatenated pulse position modulated (SCPPM) signal. A digital filter is included to compensate for timing jitter of the detector, and the decoder throughput can be modified adjusted through reconfigurable parallelization. The decoder also implements a resource-efficient, algorithmic polynomial interleaver and deinterleaver. Both FPGAs can be reconfigured to switch between pulse position modulation (PPM)-16 and PPM-32 with code rates 1/3, 1/2, and 2/3. In this paper, we describe the receiver architecture and FPGA implementation of the timing recovery loop and SCPPM decoder, FPGA utilization for the different modes, and receive modem characterization test results.

Field-programmable Gate Array↗

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process: Preprint

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ °C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process (AHP) to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Molten Salt vs. Liquid Sodium Receiver Selection Using the Analytic Hierarchy Process

An international team led by NREL analyzed the favorability of two alternative liquid receiver designs for a 700+ degrees C receiver under the Gen3 CSP Liquid Pathway project. The competing liquid heat transfer fluids were a ternary chloride salt and liquid-metal sodium. The team applied a facilitated analytic hierarchy process to arrive at a recommended alternative and set a path forward for the project. The AHP criteria were formulated, weighted, and scored by the project leadership team and technical advisory committee consisting of energy industry and CSP experts. The six-month process culminated with a two-day workshop where the sodium alternative was deemed to have both a significantly higher benefit (19.3%) and a lower LCOE (11.4%), with only a slightly higher risk (~3%) than the salt alternative. Consequently, a sodium-receiver design was selected for the Liquid Pathway project, where it will be used to charge a two-tank chloride salt thermal energy storage system.

central receiver↗

ROLE OF TOXICITY ASSESSMENT AND MONITORING IN MANAGING THE RECOVERY OF A WASTEWATER RECEIVING STREAM

We evaluate the roles of a long-term comprehensive toxicity assessment and monitoring program in management and for ecological recovery of a freshwater receiving stream impacted by industrial discharges and legacy contamination. National Pollution Discharge Elimination Permit (NPDES)-driven whole effluent toxicity (WET) tests using Ceriodaphnia and fathead minnows were conducted for more than twenty years to characterize wastewaters at the US National Nuclear Security Agency s Y-12 National Security Complex in Oak Ridge, Tennessee. Ambient toxicity tests also were conducted to assess water samples from EFPC, the stream receiving the wastewater discharges. The ambient tests were conducted as part of an extensive biological monitoring program that included routine surveys of fish, invertebrate and periphyton communities. WET testing, associated toxicant identification evaluations (TIEs), and ambient toxicity monitoring were instrumental in identifying toxicants and their sources at the Y-12 Complex, guiding modifications to wastewater treatment procedures, and assessing the success of various pollution-abatement actions. Through time, as requirements changed and water quality improved, the toxicity monitoring program became more focused. Ambient testing with Ceriodaphnia and fathead minnow larvae also was supplemented with less-standardized but more-sensitive alternative laboratory and in situ bioassays. The Y-12 Complex biological monitoring experience demonstrates the significant roles effluent and ambient toxicity testing can have in controlling and managing toxic discharges to receiving waters. It also emphasizes the value of supplementing WET and standardized ambient toxicity tests with alternative laboratory and in situ toxicity tests tailored to address specific problems.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Design and Performance of the First BICEP Array Receiver

Branches of cosmic inflationary models, such as slow-roll inflation, predict a background of primordial gravitational waves that imprints a unique odd-parity “B-mode” pattern in the Cosmic Microwave Background (CMB) at amplitudes that are within experimental reach. The BICEP/Keck (BK) experiment targets this primordial signature, the amplitude of which is parameterized by the tensor-to-scalar ratio r, by observing the polarized microwave sky through the exceptionally clean and stable atmosphere at the South Pole. B-mode measurements require an instrument with exquisite sensitivity, tight control of systematics, and wide frequency coverage to disentangle the primordial signal from the Galactic foregrounds. BICEP Array represents the most recent stage of the BK program and comprises four BICEP3-class receivers observing at 30/40, 95, 150 and 220/270 GHz. The 30/40 GHz receiver will be deployed at the South Pole during the 2019/2020 austral summer. After 3 full years of observations with 30,000+ detectors, BICEP Array will measure primordial gravitational waves to a precision σ(r) between 0.002 and 0.004, depending on foreground complexity and the degree of lensing removal. Here in this paper, we give an overview of the instrument, highlighting the design features in terms of cryogenics, magnetic shielding, detectors and readout architecture as well as reporting on the integration and tests that are ongoing with the first receiver at 30/40 GHz.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of Zinc Supplementation on Clinical Outcomes in Patients Receiving Radiotherapy for Head and Neck Cancers: A Double-Blinded Randomized Study

Purpose: To evaluate the impact of zinc supplementation on the survival of patients after receiving radiotherapy for head and neck cancers. Methods and Materials: Patients were randomly divided into two groups; experimental and control. Patients in the experimental group received a predetermined dose of a zinc supplement, and the control group, a placebo. The 50 patients in each group could be considered homogenous with respect to medical histories, tumor characteristics, and therapeutic details. Results: Patients in both groups appeared to have similar results for 3-year overall, disease-free, and metastases-free survival rates (p = 0.19, p = 0.54, and p = 0.35, respectively). However, patients in the experimental group had better 3-year local-free survival (LFS), although the difference was only marginal (p = 0.092). Another difference was that patients in the experimental group with Stages III-IV disease had a much better 3-year LFS rate when they received concurrent chemoradiotherapy (p = 0.003). Conclusions: One impact seen was that zinc supplementation improved LFS at 3 years after beginning treatment for patients with Stages III-IV disease. It is imperative that these patients be followed up for a longer period to draw a definite conclusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship Between Pelvic Organ-at-Risk Dose and Clinical Target Volume in Postprostatectomy Patients Receiving Intensity-Modulated Radiotherapy

Purpose: To investigate dose-volume consequences of inclusion of the seminal vesicle (SV) bed in the clinical target volume (CTV) for the rectum and bladder using biological response indices in postprostatectomy patients receiving intensity-modulated radiotherapy (IMRT). Methods and Materials: We studied 10 consecutive patients who underwent prostatectomy for prostate cancer and subsequently received adjuvant or salvage RT to the prostate fossa. The CTV to planning target volume (PTV) expansion was 7 mm, except posterior expansion, which was 5 mm. Two IMRT plans were generated for each patient, including either the prostate fossa alone or the prostate fossa with the SV bed, but identical in all other aspects. Prescription dose was 68.4 Gy in 1.8-Gy fractions prescribed to {>=}95% PTV. Results: With inclusion of the SV bed in the treatment volume, PTV increased and correlated with PTV-bladder and PTV-rectum volume overlap (Spearman {rho} 0.91 and 0.86, respectively; p < 0.05). As a result, the dose delivered to the bladder and rectum was higher (p < 0.05): mean bladder dose increased from 11.3 {+-} 3.5 Gy to 21.2 {+-} 6.6 Gy, whereas mean rectal dose increased from 25.8 {+-} 5.5 Gy to 32.3 {+-} 5.5 Gy. Bladder and rectal equivalent uniform dose correlated with mean bladder and rectal dose. Inclusion of the SV bed in the treatment volume increased rectal normal tissue complication probability from 2.4% to 4.8% (p < 0.01). Conclusions: Inclusion of the SV bed in the CTV in postprostatectomy patients receiving IMRT increases bladder and rectal dose, as well as rectal normal tissue complication probability. The magnitude of PTV-bladder and PTV-rectal volume overlap and subsequent bladder and rectum dose increase will be higher if larger PTV expansion margins are used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a Multicomponent Prediction Model for Acute Esophagitis in Lung Cancer Patients Receiving Chemoradiotherapy

Purpose: To construct a model for the prediction of acute esophagitis in lung cancer patients receiving chemoradiotherapy by combining clinical data, treatment parameters, and genotyping profile. Patients and Methods: Data were available for 273 lung cancer patients treated with curative chemoradiotherapy. Clinical data included gender, age, World Health Organization performance score, nicotine use, diabetes, chronic disease, tumor type, tumor stage, lymph node stage, tumor location, and medical center. Treatment parameters included chemotherapy, surgery, radiotherapy technique, tumor dose, mean fractionation size, mean and maximal esophageal dose, and overall treatment time. A total of 332 genetic polymorphisms were considered in 112 candidate genes. The predicting model was achieved by lasso logistic regression for predictor selection, followed by classic logistic regression for unbiased estimation of the coefficients. Performance of the model was expressed as the area under the curve of the receiver operating characteristic and as the false-negative rate in the optimal point on the receiver operating characteristic curve. Results: A total of 110 patients (40%) developed acute esophagitis Grade {>=}2 (Common Terminology Criteria for Adverse Events v3.0). The final model contained chemotherapy treatment, lymph node stage, mean esophageal dose, gender, overall treatment time, radiotherapy technique, rs2302535 (EGFR), rs16930129 (ENG), rs1131877 (TRAF3), and rs2230528 (ITGB2). The area under the curve was 0.87, and the false-negative rate was 16%. Conclusion: Prediction of acute esophagitis can be improved by combining clinical, treatment, and genetic factors. A multicomponent prediction model for acute esophagitis with a sensitivity of 84% was constructed with two clinical parameters, four treatment parameters, and four genetic polymorphisms.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spine Radiosurgery: A Dosimetric Analysis in 124 Patients Who Received 18 Gy

Purpose: To define the safely tolerated doses to organs at risk (OARs) adjacent to the target volume (TV) of spine radiosurgery (SRS) with 18-Gy in a single fraction. Methods and Materials: A total of 124 patient cases with 165 spine metastases were reviewed. An 18-Gy single-fraction regimen was prescribed to the 90% isodose line encompassing the TV. A constraint of 10 Gy to 10% of the spinal cord outlined 6 mm above and below the TV was used. Dosimetric data to OARs were analyzed. Results: A total of 124 patients (100%) were followed-up, and median follow-up time was 7 months (1-50 months). Symptoms and local control were achieved in 114 patients (92%). Acute Radiation Therapy Oncology Group (RTOG) grade 1 oral mucositis occurred in 11 of 11 (100%) patients at risk for oropharyngeal toxicity after cervical spine treatment. There were no RTOG grade 2-4 acute or late complications. Median TV was 43.2 cc (5.3-175.4 cc) and 90% of the TV received median dose of 19 Gy (17-19.8 Gy). Median (range) of spinal cord maximum dose (Dmax), dose to spinal cord 0.35 cc (Dsc0.35), and cord volume receiving 10 Gy (Vsc10) were 13.8 Gy (5.4-21 Gy), 8.9 Gy (2.6-11.4 Gy) and 0.33 cc (0-1.6 cc), respectively. Other OARs were evaluated when in proximity to the TV. Esophagus (n=58), trachea (n=28), oropharynx (n=11), and kidneys (n=34) received median (range) V10 and V15 of 3.1 cc (0-5.8 cc) and 1.2 cc (0-2.9 cc), 2.8 cc (0-4.9 cc), and 0.8 cc (0-2.1 cc), 3.4 cc (0-6.2 cc) and 1.6 cc (0-3.2 cc), 0.3 cc (0-0.8 cc) and 0.08 cc (0-0.1 cc), respectively. Conclusions: Cord Dmax of 14 Gy and D0.35 of 10 Gy are safe dose constraints for 18-Gy single-fraction SRS. Esophagus V10 of 3 cc and V15 of 1 cc, trachea V10 of 3 cc, and V15 of 1 cc, oropharynx V10 of 3.5 cc and V15 of 1.5 cc, kidney V10 of 0.3 cc, and V15 of 0.1 cc are planning guidelines when these OARs are in proximity to the TV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Malfunctions of Implantable Cardiac Devices in Patients Receiving Proton Beam Therapy: Incidence and Predictors

Purpose: Photon therapy has been reported to induce resets of implanted cardiac devices, but the clinical sequelae of treating patients with such devices with proton beam therapy (PBT) are not well known. We reviewed the incidence of device malfunctions among patients undergoing PBT. Methods and Materials: From March 2009 through July 2012, 42 patients with implanted cardiac implantable electronic devices (CIED; 28 pacemakers and 14 cardioverter-defibrillators) underwent 42 courses of PBT for thoracic (23, 55%), prostate (15, 36%), liver (3, 7%), or base of skull (1, 2%) tumors at a single institution. The median prescribed dose was 74 Gy (relative biological effectiveness; range 46.8-87.5 Gy), and the median distance from the treatment field to the CIED was 10 cm (range 0.8-40 cm). Maximum proton and neutron doses were estimated for each treatment course. All CIEDs were checked before radiation delivery and monitored throughout treatment. Results: Median estimated peak proton and neutron doses to the CIED in all patients were 0.8 Gy (range 0.13-21 Gy) and 346 Sv (range 11-1100 mSv). Six CIED malfunctions occurred in 5 patients (2 pacemakers and 3 defibrillators). Five of these malfunctions were CIED resets, and 1 patient with a defibrillator (in a patient with a liver tumor) had an elective replacement indicator after therapy that was not influenced by radiation. The mean distance from the proton beam to the CIED among devices that reset was 7.0 cm (range 0.9-8 cm), and the mean maximum neutron dose was 655 mSv (range 330-1100 mSv). All resets occurred in patients receiving thoracic PBT and were corrected without clinical incident. The generator for the defibrillator with the elective replacement indicator message was replaced uneventfully after treatment. Conclusions: The incidence of CIED resets was about 20% among patients receiving PBT to the thorax. We recommend that PBT be avoided in pacing-dependent patients and that patients with any type of CIED receiving thoracic PBT be followed closely.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Stereotactic Radiation Therapy can Safely and Durably Control Sites of Extra-Central Nervous System Oligoprogressive Disease in Anaplastic Lymphoma Kinase-Positive Lung Cancer Patients Receiving Crizotinib

Purpose: To analyze the durability and toxicity of radiotherapeutic local ablative therapy (LAT) applied to extra-central nervous system (eCNS) disease progression in anaplastic lymphoma kinase-positive non-small cell lung cancer (NSCLC) patients. Methods and Materials: Anaplastic lymphoma kinase-positive NSCLC patients receiving crizotinib and manifesting ≤4 discrete sites of eCNS progression were classified as having oligoprogressive disease (OPD). If subsequent progression met OPD criteria, additional courses of LAT were considered. Crizotinib was continued until eCNS progression was beyond OPD criteria or otherwise not suitable for further LAT. Results: Of 38 patients, 33 progressed while taking crizotinib. Of these, 14 had eCNS progression meeting OPD criteria suitable for radiotherapeutic LAT. Patients with eCNS OPD received 1-3 courses of LAT with radiation therapy. The 6- and 12-month actuarial local lesion control rates with radiation therapy were 100% and 86%, respectively. The 12-month local lesion control rate with single-fraction equivalent dose >25 Gy versus ≤25 Gy was 100% versus 60% (P=.01). No acute or late grade >2 radiation therapy-related toxicities were observed. Median overall time taking crizotinib among those treated with LAT versus those who progressed but were not suitable for LAT was 28 versus 10.1 months, respectively. Patients continuing to take crizotinib for >12 months versus ≤12 months had a 2-year overall survival rate of 72% versus 12%, respectively (P<.0001). Conclusions: Local ablative therapy safely and durably eradicated sites of individual lesion progression in anaplastic lymphoma kinase-positive NSCLC patients receiving crizotinib. A dose–response relationship for local lesion control was observed. The suppression of OPD by LAT in patients taking crizotinib allowed an extended duration of exposure to crizotinib, which was associated with longer overall survival.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Baseline Metabolic Tumor Volume and Total Lesion Glycolysis Are Associated With Survival Outcomes in Patients With Locally Advanced Pancreatic Cancer Receiving Stereotactic Body Radiation Therapy

Purpose: Although previous studies have demonstrated the prognostic value of positron emission tomography (PET) parameters in other malignancies, the role of PET in pancreatic cancer has yet to be well established. We analyzed the prognostic utility of PET for patients with locally advanced pancreatic cancer (LAPC) undergoing fractionated stereotactic body radiation therapy (SBRT). Materials and Methods: Thirty-two patients with LAPC in a prospective clinical trial received up to 3 doses of gemcitabine, followed by 33 Gy in 5 fractions of 6.6 Gy, using SBRT. All patients received a baseline PET scan prior to SBRT (pre-SBRT PET). Metabolic tumor volume (MTV), total lesion glycolysis (TLG), and maximum and peak standardized uptake values (SUV{sub max} and SUV{sub peak}) on pre-SBRT PET scans were calculated using custom-designed software. Disease was measured at a threshold based on the liver SUV, using the equation Liver{sub mean} + [2 × Liver{sub sd}]. Median values of PET parameters were used as cutoffs when assessing their prognostic potential through Cox regression analyses. Results: Of the 32 patients, the majority were male (n=19, 59%), 65 years or older (n=21, 66%), and had tumors located in the pancreatic head (n=27, 84%). Twenty-seven patients (84%) received induction gemcitabine prior to SBRT. Median overall survival for the entire cohort was 18.8 months (95% confidence interval [CI], 15.7-22.0). An MTV of 26.8 cm{sup 3} or greater (hazard ratio [HR] 4.46, 95% CI 1.64-5.88, P<.003) and TLG of 70.9 or greater (HR 3.08, 95% CI 1.18-8.02, P<.021) on pre-SBRT PET scan were associated with inferior overall survival on univariate analysis. Both pre-SBRT MTV (HR 5.13, 95% CI 1.19-22.21, P=.029) and TLG (HR 3.34, 95% CI 1.07-10.48, P=.038) remained independently associated with overall survival in separate multivariate analyses. Conclusions: Pre-SBRT MTV and TLG are potential predictive factors for overall survival in patients with LAPC and may assist in tailoring therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗