Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “radiation detection systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The Search for New Molecular Species in the Atmosphere of Titan

The atmosphere of Saturn’s moon, Titan, contains a vast array of minor molecular constituents originating from the dissociation of its primary compounds, N2and CH4. The extent of Titan’s photochemical network was revealed by ionospheric measurements from the Cassini orbiter, leaving substantial gaps in the corresponding neutral inventory typically probed through infrared spectroscopy. Utilizing the unprecedented sensitivity and high spectral resolution of the Atacama Large Millimeter/submillimeter Array (ALMA) at longer wavelengths, we searched for additional trace gases in Titan’s atmosphere during 2016, 2017,and 2019to further characterize Titan’s atmospheric and surface composition. These observations have resulted in the spectroscopic detections of the small cyclic molecule, cyclopropenylidene (c-C3H2), and the largest nitrile to date, methyl cyanoacetylene (CH3C3N), for the first time in Titan’s atmosphere –or anywhere else in the Solar System. We employed radiative transfer models to determine the volume mixing ratio of both species in Titan’s middle and upper atmosphere (altitudes > 350 km)and constrained the total column densities for the incorporation into future photochemical models of Titan’s atmosphere. Discrepancies between these results and current models necessitates the need for dedicated laboratory and modeling studies regarding the production pathways for trace complex organics in Titan’s atmosphere. Additionally, the measurement of previously undetected molecular species provides further incentive for the study of planetary atmospheres in the (sub)millimeter regime with facilities such as ALMA.

A E Thelen↗

GW190412: Observation of a binary-black-hole coalescence with asymmetric masses

We report the observation of gravitational waves from a binary-black-hole coalescence during the first two weeks of LIGO’s and Virgo’s third observing run. The signal was recorded on April 12, 2019 at05∶30∶44 UTC with a network signal-to-noise ratio of 19. The binary is different from observations during the first two observing runs most notably due to its asymmetric masses: a∼30M⊙black hole merged with a ∼8M⊙black hole companion. The more massive black hole rotated with a dimensionless spin magnitude between 0.22 and 0.60 (90% probability). Asymmetric systems are predicted to emit gravitational waves with stronger contributions from higher multipoles, and indeed we find strong evidence for gravitational radiation beyond the leading quadrupolar order in the observed signal. A suite of tests performed onGW190412 indicates consistency with Einstein’s general theory of relativity. While the mass ratio of this system differs from all previous detections, we show that it is consistent with the population model of stellar binary black holes inferred from the first two observing runs.

R. Abbott↗

Overview of SatCORPS Satellite-Derived Cloud and Radiation Retrieval Coverage of ARM Domains

The ARM Climate Research Facility program maintains a number of climatically representative sites, which provide long-term cloud- and climate-monitoring records via ground-based instrumentation. These measurements provide a valuable data record over a localized region, but can be greatly enhanced by use of satellite monitoring. Satellite analyses over larger domains can provide parameters helpful for monitoring climate and evaluating models. The NASA/Langley Cloud group routinely derives such cloud and radiative parameters, from various geostationary and polar-orbiting satellite coverage over ARM sites; the group provides near-realtime analyses covering the 3 ARM fixed sites, as well as the GO-Amazon AMF site. This is accomplished by employing a suite of algorithms including VISST (Visible Infrared Solar Split-Window Technique), SIST (Solar Infrared Split-Window Technique), and SINT (Solar-infrared Infrared Near-Infrared Technique), now collectively called SatCORPS (Satellite Cloud Observations and Radiative Property retrieval System). An overview and catalog of SatCORPS-derived datasets processed for ASR, and available from both the ARM archive and the NASA/Langley Cloud group website, is provided. Specific improvements included in recently added datasets such as GO-Amazon and Azores are highlighted, including an improved cloud-detection mask, as well as improvements in derived Top-of-Atmosphere (TOA) SW albedoes and LW fluxes. New narrowband-to-broadband (NB-BB) fits and corrections for improved TOA fluxes are illustrated, including MTSAT-1/CERES Aqua NB-BB fits for the TWPICE field campaign, as well as new fits covering the Azores region which incorporate GERB TOA fluxes (Geostationery Earth Radiation Budget). Finally, validation of the reprocessed SatCORPS datasets is shown.

M M Khader↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high-definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit of the ammonia leak were the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Darnell Cowan↗

BioLEAD: BioLogical Exploration via Autonomous Detection – Using Dielectric Spectroscopy to Monitor Biological Changes in Response to Deep Space Radiation

Leveraging the bio-fluidic hardware developed for BioSentinel, we propose a new payload for autonomous missions: BioLEAD – BioLogical Exploration via Autonomous Detection. With NASA's renewed focus to continue human exploration of the Moon (Artemis Program), the BioLEAD payload aims to investigate the effects of the lunar environment on biology, whether onboard a lunar lander, the Lunar Gateway, or as a free-flying CubeSat orbiting the Moon. In place of an optical detection system, BioLEAD will employ a miniaturized, non-invasive dielectric spectroscopy sensor to enable real-time monitoring of biological activity. The sensor operates by relating capacitance measurements to the dielectric properties of the cell, such as cell morphology, doubling time, and cell cycle stage. The implementation of this new sensor technology will address limitations of the optical measurement system used on BioSentinel. It will also advance the use of autonomous bioanalytical microsystems and reveal new information regarding biological responses to the Moon’s radiation environment. Most importantly, BioLEAD’s technology will be adaptable for a wide array of future missions.

Biosensor↗

Coolant Leak from ISS External Active Thermal Control System (EATCS) – An Examination of Most Probable

The Port (P1) and Starboard (S1) External Active Thermal Control Systems (EATCS) are single phase, mechanically pumped ammonia loops that operate independently to cool the majority of the hardware and payloads onboard the International Space Station (ISS). A slow ammonia leak was detected using pressure and quantity telemetry five years after the P1 EATCS was activated. The leak gradually accelerated to a rate that locating and isolating the leak became imperative to maintain cooling capability. Partial pressure measurements from the Robotic External Leak Locator (RELL) scan surveys narrowed the search to the supply and return jumpers connecting one of three radiators to the system. Subsequently, the ISS crew performed high definition video surveys during an Extravehicular Activity (EVA), or spacewalk, and ammonia flakes were observed projecting from the jumpers. Thus, the ground teams were confident that the culprit for the ammonia leak was the jumpers. The ammonia leak stopped after ground teams remotely isolated and vented those jumpers and associated radiator. Both jumpers were removed and returned to the ground, and a root cause investigation was conducted. A calibrated leak test determined the bulk of the ammonia leaked through a pair of seals in a Quick Disconnect (QD), or connector, on one end of the return jumper. The return jumper QD was dissected, visually inspected, chemically tested and evaluated. The results indicated the most probable cause of the accelerating ammonia leak was due to defective seals, plating delamination underneath the seals, and on-orbit thermal cycles exacerbating the delamination. Both jumpers were refurbished, relaunched to the ISS, and scheduled to be reinstalled during an EVA in 2022. It appeared the issue was unique, but recently the S1 EATCS is showing signs of an accelerating ammonia leak, and RELL scans narrowed the source to a similar pair of radiator jumpers.

Thermal Control↗

GW190412: Observation of a binary-black-hole coalescence with asymmetric masses

We report the observation of gravitational waves from a binary-black-hole coalescence during the first two weeks of LIGO's and Virgo's third observing run. The signal was recorded on April 12, 2019 at 05:30:44 UTC with a network signal-to-noise ratio of 19. The binary is different from observations during the first two observing runs most notably due to its asymmetric masses: A ~30 M ⊙ black hole merged with a ~8 M ⊙ black hole companion. The more massive black hole rotated with a dimensionless spin magnitude between 0.22 and 0.60 (90% probability). Asymmetric systems are predicted to emit gravitational waves with stronger contributions from higher multipoles, and indeed we find strong evidence for gravitational radiation beyond the leading quadrupolar order in the observed signal. A suite of tests performed on GW190412 indicates consistency with Einstein's general theory of relativity. While the mass ratio of this system differs from all previous detections, we show that it is consistent with the population model of stellar binary black holes inferred from the first two observing runs.

79 ASTRONOMY AND ASTROPHYSICS↗

Fluorescence from VUV excitation of formaldehyde

The 105-180-nm photoabsorption and fluorescence cross sections of H2CO are determined experimentally using a synchrotron-radiation light source and the apparatus described by Lee (1980). The results are presented in tables and graphs and discussed. VUV emission with threshold wavelength 140.3 nm is detected and attributed to the A 1Pi - X 1Sigma(+) system of CO, and UV emission from the HCO (B-X) system is found below a 147.5-nm threshold, the H-HCO dissociation energy having an upper limit of 3.61 + or - 0.03 eV. At 116 nm, the maximum quantum yields of the VUV and UV fluorescences are about 1.6 and 0.23 percent, respectively.

Suto, Masako↗

Optical leak detection of oxygen using IR-laser diodes

The ability to accurately measure the concentration of gaseous oxygen and its corresponding flow rate is becoming of greater importance. The technique being presented is based on the principal of light attenuation due to the absorption of radiation by the A-band of oxygen which is located in the 759-770 nm wavelength range. With an ability to measure the change in the light transmission to 0.05 percent, a sensitive optical leak detection system which has a rapid time response is possible. In this research program, the application of laser diode technology and its ability to be temperature tuned to a selected oxygen absorption spectral peak has allowed oxygen concentrations as low as 16,000 ppm to be detected.

Disimile, P. J.↗

The terrestrial gravitational wave environment from known sources

The objective of this project was to produce a gravitational wave spectral line list of all known binary stars producing expected strain amplitudes at Earth in excess of h = 10 (exp -21), or gravitational wave fluxes in excess of F = 10 (exp -12) erg cm(exp -2) s(exp -1). These strain and flux limits lie above the anticipated detection thresholds for space-borne laser interferometers capable of detecting gravitational radiation in the 10 micron Hz to 1 Hz frequency range. The source list was intended to provide frequency (including each harmonic), amplitude and phase (for each polarization and harmonic), and celestial coordinates for each system, lacking only the orientation of the principal polarization axis with respect to the pole of the coordinate system, and the sign of the source phase and frequency (or, equivalently, of the sense of rotation of the strain tensor with time) from providing a complete source description. Such a spectral line list would lay essential groundwork for high-sensitivity, low-frequency searches for gravitational radiation.

Webbink, Ronald F.↗

Terahertz NDE for Metallic Surface Roughness Evaluation

Metallic surface roughness in a nominally smooth surface is a potential indication of material degradation or damage. When the surface is coated or covered with an opaque dielectric material, such as paint or insulation, then inspecting for surface changes becomes almost impossible. Terahertz NDE is a method capable of penetrating the coating and inspecting the metallic surface. The terahertz frequency regime is between 100 GHz and 10 THz and has a free space wavelength of 300 micrometers at 1 THz. Pulsed terahertz radiation, can be generated and detected using optical excitation of biased semiconductors with femtosecond laser pulses. The resulting time domain signal is 320 picoseconds in duration. In this application, samples are inspected with a commercial terahertz NDE system that scans the sample and generates a set of time-domain signals that are a function of the backscatter from the metallic surface. Post processing is then performed in the time and frequency domains to generate C-scan type images that show scattering effects due to surface non-uniformity.

Madaras, Eric I.↗

Polarimeter Arrays for Cosmic Microwave Background Measurements

We discuss general system architectures and specific work towards precision measurements of Cosmic Microwave Background (CMB) polarization. The CMB and its polarization carry fundamental information on the origin, structure, and evolution of the universe. Detecting the imprint of primordial gravitational radiation on the faint polarization of the CMB will be difficult. The two primary challenges will be achieving both the required sensitivity and precise control over systematic errors. At anisotropy levels possibly as small as a few nanokelvin, the gravity-wave signal is faint compared to the fundamental sensitivity limit imposed by photon arrival statistics, and one must make simultaneous measurements with large numbers, hundreds to thousands, of independent background-limited direct detectors. Highly integrated focal plane architectures, and multiplexing of detector outputs, will be essential. Because the detectors, optics, and even the CMB itself are brighter than the faint gravity-wave signal by six to nine orders of magnitude, even a tiny leakage of polarized light reflected or diffracted from warm objects could overwhelm the primordial signal. Advanced methods of modulating only the polarized component of the incident radiation will play an essential role in measurements of CMB polarization. One promising general polarimeter concept that is under investigation by a number of institutions is to first use planar antennas to separate millimeter-wave radiation collected by a lens or horn into two polarization channels. Then the signals can be fed to a pair of direct detectors through a planar circuit consisting of superconducting niobium microstrip transmission lines, hybrid couplers, band-pass filters, and phase modulators to measure the Stokes parameters of the incoming radiation.

Stevenson, Thomas↗

New Developments in FPGA: SEUs and Fail-Safe Strategies from the NASA Goddard Perspective

It has been shown that, when exposed to radiation environments, each Field Programmable Gate Array (FPGA) device has unique error signatures. Subsequently, fail-safe and mitigation strategies will differ per FPGA type. In this session several design approaches for safe systems will be presented. It will also explore the benefits and limitations of several mitigation techniques. The intention of the presentation is to provide information regarding FPGA types, their susceptibilities, and proven fail-safe strategies; so that users can select appropriate mitigation and perform the required trade for system insertion. The presentation will describe three types of FPGA devices and their susceptibilities in radiation environments.

Error Correction and Detection (EDAC)↗

BioSentinel

The BioSentinel mission was selected in 2013 as one of three secondary payloads to fly on the Space Launch Systems first Exploration Mission (EM-1) planned for launch in December 2017. The primary objective of BioSentinel is to demonstrate the use of simple model organisms as biosentinels to detect, measure, and correlate the impact of space radiation to biological organisms including humans, a health risk over long durations beyond Low Earth Orbit (LEO). While progress identifying and characterizing biological radiation effects using Earth-based facilities has been significant, no terrestrial source duplicates the unique space radiation environment.

yeast S. cerevisiae↗

TROPOMI Geometry-dependent Lambertian-Equivalent surface Reflectivity (GLER) Product for Improved Trace-Gas Retrieval

Accurate information about the reflectivity of the Earth's surface is required for most satellite retrievals of atmospheric composition, and this information is generally taken from monthly surface reflectivity climatology that neglects angular dependence. Previously we introduced Geometry-dependent Lambertian-equivalent surface reflectivity (GLER) which captures solar and satellite viewing angle dependence as well as daily and seasonal changes. GLER is calculated from simulations of Rayleigh-only top-of-atmosphere (TOA) radiances over non-Lambertian surfaces. We use NASA's Moderate Resolution Imaging Spectroradiometer (MODIS) bidirectional reflectance distribution function (BRDF) product over land and the wind-dependent Cox–Munk wave-facet slope distribution including water-leaving radiance over water to accounts for surface BRDF. We have developed global GLER product, previously for the Ozone Monitoring Instrument (OMI) and recently for Sentinel-5 Precursor (S5P) TROPOspheric Monitoring Instrument (TROPOMI) with several new improvements and updates. We have implemented the near real time daily V006 MODIS MCD43C1 BRDF data and gap-filled with a daily BRDF coefficient climatology created from 2002-2017 V006 MCD43GF data. The NASA’s Global Modelling Initiative hourly 0.25 x 0.25 deg Replay simulations are used for more accurate determination of pixel specific terrain pressure. To improve detection of seasonal snow/ice scenes, we use the 4-km snow cover product from the Interactive Multi-sensor Snow and Ice Mapping System (IMS). Finally, we use an improved version of the vector linearized discrete ordinate radiative transfer (VLIDORT) for update of the top-of-atmosphere (TOA) radiance look-up-tables (LUTs). We demonstrate how the use of GLER is beneficial to TROPOMI’s high spatial resolution (up to 3.5 km x 3.5 km) measurements to monitor atmospheric trace gas pollutants down to the sub-city scale.

TROPOMI↗

System and method for multi-channel pyrometer allowing non-contact temperature measurements down to 800 K on the microsecond scale

The present disclosure relates to a system for sensing temperature changes on a microsecond scale. The system uses a multi-channel pyrometer that works in the NIR spectrum to receive thermal radiation. Each channel includes an interference filter tuned to pass thermal radiation within a specified wavelength range, and a detector. Each detector detects thermal radiation focused on it. Each channel further includes an interference filter which reflects thermal radiation which does not pass through it to a subsequent downstream interference filter of a subsequent channel. Each subsequent interference filter is oriented to reflect the thermal radiation not passing through it to a next downstream one of the subsequent interference filters. A subsystem is included for receiving the output from the detectors and determining sensed temperature data therefrom, allowing measurement of temperatures down to 800 K.

Montgomery, Jeffrey↗

EcoSpec: Highly Equipped Tower-Based Hyperspectral and Thermal Infrared Automatic Remote Sensing System for Investigating Plant Responses to Environmental Changes

Despite an advanced ability to forecast ecosystem functions and climate at regional and global scales, little is known about relationships between local variations in water and carbon fluxes and large-scale phenomena. To enable data collection of local-scale ecosystem functions to support such investigations, we developed the EcoSpec system, a highly equipped remote sensing system that houses a hyperspectral radiometer (350–2500 nm) and five optical and infrared sensors in a compact tower. Its custom software controls the sequence and timing of movement of the sensors and system components and collects measurements at 12 locations around the tower. The data collected using the system was processed to remove sun-angle effects, and spectral vegetation indices computed from the data (i.e., the Normalized Difference Vegetation Index (NDVI), Normalized Difference Water Index (NDWI), Photochemical Reflectance Index (PRI), and Moisture Stress Index (MSI)) were compared with the fraction of photochemically active radiation (fPAR) and canopy temperature. The results showed that the NDVI, NDWI, and PRI were strongly correlated with fPAR; the MSI was correlated with canopy temperature at the diurnal scale. These correlations suggest that this type of near-surface remote sensing system would complement existing observatories to validate satellite remote sensing observations and link local and large-scale phenomena to improve our ability to forecast ecosystem functions and climate. The system is also relevant for precision agriculture to study crop growth, detect disease and pests, and compare traits of cultivars.

47 OTHER INSTRUMENTATION↗