Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “precision timing applications”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Performance evaluation of cosmic ray muon trajectory estimation algorithms

Muons, being elementary particles with minimal interaction with nuclear materials and abundant at sea level, have sparked interest in utilizing them for imaging various applications, such as mining [Borselli et al., Sci. Rep. 12, 22329 (2022)], volcano imaging [Nagamine et al., Nucl. Instrum. Meth. A, 356, 585(1995)], and underground tunnel detection [Guardincerri et al., Pure Appl. Geophys. 174, 2133 (2017)]. Recently, their use in nuclear nonproliferation and safeguard verification has gained attention, particularly in cargo screening for nuclear waste smuggling [Baesso et al., J. Instrum. 9, C10041 (2014)], source localization [L. J. Schultz et al., Nucl. Instrum. Meth. A 519, 687 (2004)], and locating nuclear fuel debris in reactors [Borozdin et al., Phys. Rev. Let. 109, 152501 (2012)]. However, the resolution of muon image reconstruction techniques is limited due to multiple Coulomb scattering (MCS) within the target object. To achieve robust muon tomography, it is crucial to develop efficient and flexible physics-based algorithms that can model the MCS process accurately and estimate the most probable trajectory of muons as they pass through the target object. To address this limitation, in this study, a novel algorithmic approach utilizing the Bayesian probability theory and Gaussian approximation of MCS is chosen. Different energy levels, materials, and target sizes were considered in the evaluations. The results demonstrate that the Generalized Muon Trajectory Estimation (GMTE) algorithm offers significant improvements over currently used algorithms. Across all test scenarios, the GMTE algorithm demonstrated ~50% and 38% increase in precision compared to Straight Line Path (SLP) and Point of Closest Approach (PoCA) algorithms, respectively. Furthermore, it exhibited 10%–35% and 10%–15% increases in muon flux utilization for high and medium Z materials, respectively, compared to the PoCA algorithm. In conclusion, the extensive simulations confirm the enhanced performance and efficiency of the GMTE algorithm, offering improved resolution and reduced measurement time for cosmic ray muon imaging compared to the current SLP and PoCA algorithms.

79 ASTRONOMY AND ASTROPHYSICS↗

The Timepix4 analog front-end design: Lessons learnt on fundamental limits to noise and time resolution in highly segmented hybrid pixel detectors

This manuscript describes the optimization of the front-end readout electronics for high granularity hybrid pixel detectors. The theoretical study aims at minimizing the noise and jitter. The model presented here is validated with both circuit post layout simulations and measurements on the Timepix4 Application Specific Integrated Circuit (ASIC). The analog front-end circuit and the procedure to optimize the dimensions of the main transistors are described with detail. The Timepix4 is the most recent ASIC designed in the framework of the Medipix4 Collaboration. It was manufactured in 65nm CMOS process, and consists of a four side buttable matrix of 448 × 512 pixels with 55µm pitch. The analog front-end has a gain of ~36mV/ke - when configured in High Gain Mode, and ~20mV/ke - when configured in Low Gain Mode. The Equivalent Noise Charge (ENC) is ~68e - rms and ~80e - rms in High Gain Mode and in Low Gain Mode respectively. In event driven mode the incoming hits can be time stamped within a ~ 200ps time bin and the chip can deal with a maximum flux of ~ 3.6MHzmm –2 s –1 . In photon counting mode, the chip can deal with up to ~ 5GHzmm –2 s –1 . The routine designed to optimize the Timepix4 front-end is then used to analyze the performance limits in terms of jitter and noise for Charge Sensitive Amplifiers in pixel detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using Best Basis Inventory Data to Direct Strategies for Real Time Monitoring of Hanford High Level Waste – 26226

The potential to accelerate the processing of low- and high-level tank waste by applying real-time monitoring (RTM) of chemical and physical properties has prompted research into the suitability of multiple analytical methods for that purpose. The broad variety of waste stream properties and the large number of analytes of interest (as evidenced by Waste Acceptance Criteria (WAC) and Process Control Limit (PCL) lists) lead to an overwhelming set of possible analytical scenarios. This report describes the use of Best Basis Inventory (BBI) data to find the most relevant analytical targets for the specific case of monitoring the blending of High Level Waste from multiple tanks prior to introduction into a vitrification facility. Campaigns for blending this waste to minimize the risk of exceeding WACs and PCLs have been proposed. However, the predicted compositions of the blended materials do not incorporate any uncertainties that may be associated with the representativeness of the waste layer samples or the laboratory analyses that generated the BBI data. Also, they do not include any uncertainty associated with the precision of collecting highly specific fractions of the layers during a blending campaign or any inhomogeneities that may exist in those layers. Monte Carlo methods are used to apply uncertainties to the compositions of the individual layers specified in the campaign recipes. The resulting variations in the compositions of the blended materials allow estimation of the risks of exceeding WACs and PCLs for each campaign. A critical subset of WACs/PCLs – NOx, NaK, AlFeZr, and S – are especially at risk of being exceeded in multiple campaigns. These analytes should be the focus of instrument development. We also have extracted the expected solid/supernate distribution for these analytes, which establishes important performance criteria for individual analytical methods. The BBI data also permits an understanding of the different chemical forms in which the analytes appear. Thus, the need to establish instrumental sensitivity to these forms can be gainfully addressed. Although concentrating on one specific application – the blending of tank waste - this approach should be generalizable for the analysis of other possible RTM applications for waste processing.

Lascola, Robert [Savannah River National Laborator↗

Precision Agriculture using Networks of Degradable Analytical Sensors (PANDAS) (Final Technical Report)

Precision agriculture, where sensing of soil, environment and crop conditions are used to precisely synchronize inputs (such as water and fertilizer) to crop needs enhances input use efficiency. This can improve yields and farm profitability while mitigating environmental losses, improving soil carbon content and substantially decreasing energy use for food, feed and fuel crops. Unfortunately, farmers are not yet able to harness the full potential of these management technologies as there is a lack of available management information, and there is therefore a need for sensors that are able to economically measure spatio-temporal variability in soil and crop properties of extremely heterogeneous farm fields precisely at high resolution and at low cost. Real-time, in-situ monitoring of agricultural soil conditions is today carried out using devices that limit the total number of nodes that can be used economically to typically one per acre or less. Higher spatio-temporal resolution sensing would enable more precise agricultural input optimization, with significant benefits to the farmer and the environment. In order to address this issue, this project focused on developing additively manufactured, biodegradable, soil sensors with predicted costs of < $\$$1 per unit to monitor crop inputs (such as water and fertilizer) that predictably, harmlessly degrade away into the soil when no longer needed. These sensor nodes should be easy to place, accurately and continuously monitor soil and crop conditions for an entire season, be read remotely using existing farm equipment, require no ongoing maintenance, not impede farm operations and produce no persistent waste. This approach could enable a >100× increase in information density over current solutions for precision farming of row and other crops, and lead to significant reductions in input energy use and provide increased yield for biofuel crops. Over the course of this project the team at the University of Colorado Boulder, University of California Berkeley, and Colorado State University/Kansas State University investigated a wide range of printable biodegradable electronic materials and sensor designs for determining soil moisture and soil nitrate concentration. These efforts expanded the available materials set for printed soil degradable electronic materials, particularly for conductors, enabling high conductivity and stability. Printed soil moisture and nitrate sensors with suitable sensitivity and selectivity were developed and characterized. Low power and passive wireless electronic systems were integrated with the soil sensors, and testing was carried out with completed sensors to understand their functionality under agricultural conditions. Additionally, other sensor types enabled by the biodegradable materials set created during this project, such as soil microbial activity sensors, were also developed and demonstrated. Project outputs include 10 peer reviewed publications, 4 patent applications, 21 technical presentations, 3 PhD thesis, 10 media reports, 8 additional grants worth over $\$$6M, and the formation of 3 start-up companies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Relocating microseismicity from downhole monitoring of the Decatur CCS site using a modified double-difference algorithm

SUMMARY The injection of CO2 at the Decatur carbon capture and storage site has generated significant microseismic activity, which occurs in distinct spatial clusters up to approximately 2.2 km from the primary injection well. Accurate and precise event locations are vital for the characterization of the microseismicity to help understand the reservoir response to the CO2 injection, whilst enabling the identification of minor faults and fractures below the resolution of conventional active seismic imaging. However, microseismic monitoring of fluid injection sites, such as Decatur, is often performed using a network of borehole sensors often from a single well. While these downhole sensors have excellent detection capabilities, their poor azimuthal coverage limits the ability to precisely determine event locations. We have developed a modified double-difference relocation algorithm suitable for both 1-D and 3-D velocity models, and which incorporates differential back azimuth observations to allow the benefits of the original double-difference algorithm to be applicable to a downhole microseismic monitoring setting. Applying the modified double-difference algorithm to the microseismicity at Decatur, we have successfully relocated 4293 events. The relocation included over 59 million observations for 757 285 event pairs, split across seven geographic regions. Despite the majority of observations being recorded in only two boreholes, with an almost identical azimuthal coverage, the results have shown to be reliable with significantly reduced residuals and low uncertainties associated with the final locations. We have analysed the residuals in terms of their association with each geographic region, data type, station and individual events, to fully appreciate their influence in the inversion and the fit of the data to the final set of event locations. For each region, the relocated seismicity has become less diffuse with improved clustering, and with newly visible linear features often orientated in a NE–SW direction. These results show the potential improvements that can be made to microseismic event locations recorded by a borehole network with a limited and variable azimuthal distribution.

58 GEOSCIENCES↗

LiDAR-Aided Interior Orientation Parameters Refinement Strategy for Consumer-Grade Cameras Onboard UAV Remote Sensing Systems

Unmanned aerial vehicles (UAVs) are quickly emerging as a popular platform for 3D reconstruction/modeling in various applications such as precision agriculture, coastal monitoring, and emergency management. For such applications, LiDAR and frame cameras are the two most commonly used sensors for 3D mapping of the object space. For example, point clouds for the area of interest can be directly derived from LiDAR sensors onboard UAVs equipped with integrated global navigation satellite systems and inertial navigation systems (GNSS/INS). Imagery-based mapping, on the other hand, is considered to be a cost-effective and practical option and is often conducted by generating point clouds and orthophotos using structure from motion (SfM) techniques. Mapping with photogrammetric approaches requires accurate camera interior orientation parameters (IOPs), especially when direct georeferencing is utilized. Most state-of-the-art approaches for determining/refining camera IOPs depend on ground control points (GCPs). However, establishing GCPs is expensive and labor-intensive, and more importantly, the distribution and number of GCPs are usually less than optimal to provide adequate control for determining and/or refining camera IOPs. Moreover, consumer-grade cameras with unstable IOPs have been widely used for mapping applications. Therefore, in such scenarios, where frequent camera calibration or IOP refinement is required, GCP-based approaches are impractical. To eliminate the need for GCPs, this study uses LiDAR data as a reference surface to perform in situ refinement of camera IOPs. The proposed refinement strategy is conducted in three main steps. An image-based sparse point cloud is first generated via a GNSS/INS-assisted SfM strategy. Then, LiDAR points corresponding to the resultant image-based sparse point cloud are identified through an iterative plane fitting approach and are referred to as LiDAR control points (LCPs). Finally, IOPs of the utilized camera are refined through a GNSS/INS-assisted bundle adjustment procedure using LCPs. Seven datasets over two study sites with a variety of geomorphic features are used to evaluate the performance of the developed strategy. The results illustrate the ability of the proposed approach to achieve an object space absolute accuracy of 3–5 cm (i.e., 5–10 times the ground sampling distance) at a 41 m flying height.

47 OTHER INSTRUMENTATION↗

Temporal Analysis and Scene Change Detection in Multispectral Overhead Imagery

Scene change detection can be a tedious and time consuming process especially when concerning large geographical areas, and the process can be even more cumbersome when analyzing changes in an area over large spans of time. Developing a useful way to help analysts recognize at what points in time significant changes to a scene have occurred can allow them to better focus their efforts in characterizing events. Applications include: Facility monitoring, Construction chronology, Monitoring of vehicle/aircraft activity, Characterization of larger sequences of events. In large areas exceeding hundreds to thousands of square kilometers in size, it can be difficult localizing when scene changes have occurred. Analysts can spend hours going through imagery to try to identify new construction, monitor facility activities, monitor vehicle movement, etc. where the object of interest may only be a few square meters. Our goal is to help cut down this time by giving analysts change maps with hot spots of change, allowing them to focus on regions that have experienced actual change in time frames they're interested in. Additionally, by combining these change maps into layers within a data cube, analysts can examine the change maps from a temporal perspective, allowing events to be characterized over spans of time. By opening the data cube in an imaging software capable of separating the layers, we can analyze the change maps sequentially, allowing us to examine scene changes occurring over time. As an example, we examined overhead imagery from Planet Labs of what appears to be a parking lot on Fort Irwin over the course of a year using ENVI, a geospatial satellite imagery analysis software. Using ENVI, we generate a graph of changes over time, and notice a particular segment near the end of our analysis window where no changes are detected. Examination of the actual satellite imagery reveals that during this time span, the parking lot was empty. This could be due to facility shutdown for maintenance or upgrades, or possibly even total workforce/vehicle fleet movement. Information like this could help analysts better characterize events, as well as to help create clearer timelines in larger sequences of events. Workflow steps: - Collect multiple maps of the same AOI (Area of Interest) during a time span of interest; - Generate change maps from AOI maps; - Generate data cube from change maps. An analyst can use the data cube to help inspect an AOI for activities within a time span of interest. If an event of interest is discovered, the analyst can then refer to the maps corresponding to the appropriate dates and times in the data cube to see precisely what is transpiring. The biggest objective being worked on is improving the change detection methodology employed. We currently use PCA-EM (Principal Component Analysis with Expectation Maximization), but we are currently focusing on implementing IR-MAD (Iteratively Reweighted Multivariate Alteration Detection) to be used in conjunction with PCA-EM in an effort to decrease false positivity and noise in the change maps we generate.

42 ENGINEERING↗

Biochemical properties of glycerol kinase from the hypersaline-adapted archaeon Haloferax volcanii

ABSTRACT Extremophilic microorganisms are promising candidates for industrial and analytical biocatalysis.Haloferax volcanii, a halophilic archaeon that prefers glycerol over glucose, channels this substrate into central metabolism through glycerol kinase (GK). Here, we report the biochemical properties ofH. volcaniiGK and its potential for biotechnological applications. An N-terminal His-tagged GK was functionalin vivoand yielded 3 mg/L culture—4.5 times more enzyme than a C-terminal StrepII-tagged version. Size exclusion chromatography revealed a glycerol-induced oligomeric shift from homodimer to a dimer-dominant state with detectable tetramer. The purified enzyme showed robust activity across broad pH and salinity ranges, with optimal activity at 100 mM NaCl and 50°C–60°C. It retained catalytic activity in 5%–10% dimethyl sulfoxide (DMSO) and crude glycerol containing methanol. His-GK was freeze-thaw stable and thermotolerant in 2 M NaCl buffers. In the absence of ligands, the enzyme’s melting temperature (T m ) was 80°C. Glycerol increased the T m to 85°C, and combinations with MgCl₂ (84°C) or ATP (88°C) provided further stabilization. The highest T m (89°C) occurred with all three ligands, suggesting a cumulative stabilizing effect. Kinetic analyses revealed positive cooperativity for glycerol, ATP, and Mg² + ; Mn² + and Co² + also supported the activity.H. volcaniiGK is the first known GK to exhibit positive cooperativity with glycerol and ATP. Its high stability and substrate flexibility support its use in biodiesel waste valorization,in vitrobiocatalysis, and biosensor development—applications demanding robust, specific, and stable enzymes. IMPORTANCE This study reveals thatH. volcaniiGK exhibits positive cooperativity for glycerol, ATP, and Mg² + , a kinetic feature not previously reported for glycerol kinases. This behavior enables steep, switch-like responses to small substrate changes, offering unique advantages for biosensor design. Importantly,H. volcaniiGK also maintains high activity under extreme salinity, temperature, broad pH, and solvent conditions that typically limit enzyme use in industrial and environmental applications. These traits make this GK an ideal candidate for enzyme-based biosensors, which often suffer from poor tolerance to pH, solvent, and thermal stress. Its robustness supports its use in cross-linked enzyme crystals, an immobilization method that enhances enzyme stability and reusability under harsh conditions. Moreover, GKs are already employed in Mg² + detection kits; however,H. volcaniiGK’s ability to tolerate and respond to diverse divalent cations (e.g., Co² + , Mn² + ) broadens their potential for pollutant detection and environmental monitoring. These features collectively positionH. volcaniiGK as a valuable biocatalyst for biosensing,in vitrodiagnostics, and biotechnological applications requiring both precision and durability.

Biotechnology & Applied Microbiology↗

Towards Precision Photometric Type ia Supernova Cosmology With Machine Learning

The revolutionary discovery of dark energy and accelerating cosmic expansion was made with just 42 type Ia supernovae (SNe Ia) in 1999. Since then, large synoptic surveys, e.g., Dark Energy Survey (DES), have observed thousands more SNe Ia and the upcoming Rubin Legacy Survey of Space and Time (LSST) and Roman Space Telescope promise to deliver millions in the next decade. This unprecedented data volume can produce the required precision to unambiguously test concordance cosmology which could represent a monumental shift in our understanding of dark energy and its role in cosmic history. However, extracting a pure SN Ia sample with accurate redshifts for such a large dataset will be a challenge. Specifically, spectroscopic classification will not be possible for the vast majority of discovered objects, and only ~25% will have spectroscopic redshifts. This thesis presents a series of observational and methodological studies designed to address the questions associated with this new era of photometric SN Ia cosmology. First, we present a machine learning method for photometric classification of SNe, Supernova Classification with a COnvolutional Neural Network (SCONE). Photometric classification enables SNe with no spectroscopic information to be confidently categorized, and is a critical component of current and future analysis pipelines. SCONE achieves >99% accuracy distinguishing simulated SNe Ia from non-Ia SNe, and has been integrated into DES, LSST, and Roman analysis pipelines. We also demonstrate the efficacy of SCONE on early-time photometric classification, which will be vital for optimal allocation of spectroscopic resources. We show that SCONE can distinguish between 6 SN types with 75% accuracy on the night of initial discovery, comparable to results in the literature for full-phase SNe. Next, we study current methods for estimating SN Ia redshifts and propose a machine learning alternative that uses SN photometry alone to extract redshift information. Most SNe Ia inherit redshift information from their host galaxy, but the process of matching SNe to the correct host galaxy can be challenging. We systematically analyze the impact of incorrect redshifts from host galaxy mismatch on 5 years of DES SN data, and conclude that improved host matching or redshift estimation methods can reduce our systematic errors by ~10%. In response to this finding, we present a SN photometry-only method for estimating redshifts independent of host galaxy information, Photo-zSNthesis. We show that Photo-zSNthesis redshift estimates are accurate to within 2% across the full redshift range of LSST, a first in the literature. Finally, we focus on the robustness of machine learning (ML) algorithms for real-world and scientific applications. ML models generalize poorly beyond their training set and often experience severe performance degradation when deployed on new data. We demonstrate a general method for improving robustness that achieves new state-of-the-art results on astronomical object classification, wildlife identification, and tumor detection.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Direct observation of C 3 S particle dissolution using fast nano X-ray computed tomography

Tricalcium silicate (C 3 S) occupies 50 % to 70 % of ordinary portland cement (OPC) by mass and it is an important component affecting the hydration of OPC [1], [2], [3], [4], [5], [6], [7]. Generally, the hydration of C 3 S is described by two processes: the dissolution of C 3 S particles and the precipitation of hydration products. While it is understood that the dissolution rates of C 3 S vary with time, more precise measurements are needed to understand this process. Many mechanisms have been proposed to explain the time-evolving dissolution rates of C 3 S [2]. The metastable barrier hypothesis suggests that a thin metastable layer of hydrates forms around the C 3 S particle surface and prohibits the access of grains to the aqueous solution [8], [9], [10], [11], [12]. The slow dissolution step hypothesis suggests that the increased ion concentration from the initial reaction delays the C 3 S dissolution [2], [13], [14], [15], [16], [17]. More recent publications suggest that C 3 S may react differently depending on the existence of crystallographic defects [18], [19], [20]. Etch pits are thought to open on the particle surface during the initial reaction and this contributes to the C 3 S dissolution [21], [22]. As hydrates precipitate and cover these highly reactive surfaces, hydration slows down and the induction period starts [18], [23], [24], [25], [26]. Many experiments have been conducted to test the aforementioned mechanisms. Some hydration studies utilize bulk measurements, such as isothermal calorimetry [27], [28], [29], pore solution analysis [30], quasi-elastic neutron scattering [31], and nuclear magnetic resonance spectroscopy [32], [33]. One limitation of these measurements is that they do not provide direct and detailed information on the individual C 3 S particles. Some other studies utilize imaging techniques, such as scanning electron microscopy (SEM) [34], [35], [36] and transmission electron microscopy (TEM) [37]. However, SEM/TEM cannot track the evolution of individual particles throughout hydration [34], [35], [38], [39], [40] and they do not give insights into the microstructure of materials before hydration [34], [35], [39]. This makes it challenging to draw strong conclusions from only SEM or TEM observations. Synchrotron X-ray tomography techniques have been used more broadly in recent years to study cement hydration. They are not only non-destructive but also able to image a sample in full 3D with resolutions that can reach from micron to nanoscale. Nano computed tomography (nCT) is one technique that has been applied to study cement hydration at the nanoscale [26], [41]. A typical nCT can reach a pixel size from 15 to 65 nm, providing enough detail for observing features <1 μm. However, nCT often takes >0.5 h to finish one scan. This makes the application of this technique on continuous scans for in-situ observations challenging. Fast X-ray computerized tomography (fCT) is another technique that has shown success in studying the time-evolving cement microstructures [20], [42], [43], [44], [45], [46], [47], [48], [49]. Due to the high flux of the X-ray beam from the synchrotron ring, fCT allows a scan to be captured within 1 min at a pixel size of 1 μm. This allows a paste sample to be continuously scanned during the hydration process. However, the micron-sized resolutions limit does not provide detailed insights for particles <5 μm [20], [49]. Fortunately, the combination of nCT and fCT has allowed the development of fast nano X-ray computed tomography (fnCT). fnCT can capture a 3D data set in <2 min at a pixel size of 50 nm. This makes this procedure an exciting method to evaluate hydrating pastes. fnCT collects multiple X-ray radiographs at various rotation angles and generates a 3D model of the scanned sample, which is also referred to as a 3D tomography [50], [51]. In one tomography, the X-ray absorptions of different components (e.g., C 3 S and hydrates) differ as functions of density and chemistry [52], [53]. These X-ray absorption contrasts can be used to extract detailed information about the 3D microstructure [26], [54], [55]. In this paper, fnCT is used to collect time-lapse tomographs of hydrating C 3 S paste from 18 min after mixing to 7 h of hydration. The bulk measurements of anhydrous C 3 S, as well as the microstructural changes of individual C 3 S particles, are directly observed, quantified, and discussed. The dissolution behavior of C 3 S particles at various size scales is systematically analyzed and compared. This work aims to find the relationship between the size of C 3 S particle sizes and their dissolution rates. This provides significant insights into the early-age hydration of C 3 S on length and time scales not previously possible. Because of the magnitude of the data and the substantial amount of observations, this work will solely focus on the change in the anhydrous particles. Changes in the hydration products will be reported in future work.

42 ENGINEERING↗

Measurement of Neutron Multiplicity in Charged Current Neutrino Interactions on Oxygen

The Accelerator Neutrino Neutron Interaction Experiment (ANNIE) is a 26-ton gadolinium-doped water Cherenkov detector located 100~meters downstream in the Booster Neutrino Beam (BNB) at the Fermi National Accelerator Laboratory (Fermilab). Its primary goals are to (1) measure the neutron yield from $\nu_\mu$ interactions as a function of momentum transfer $Q^2$ so that neutrino-nucleus interaction models can be better constrained, and (2) demonstrate the power of novel, fast-timing detectors with the first deployment of Large Area Picosecond PhotoDetectors (LAPPDs). Current knowledge of neutrino-nucleus interactions fall short in modeling the topologies of such interactions, leading to inaccurate reconstruction of event kinematics such as particle energy, direction, and vertex. As a consequence, the accuracy of cross section measurements is impacted, which is necessary for precise physics measurements. Neutrons are an indication of inelasticity and affect the determination of the energy of the parent neutrino. Quantifying the neutron yield is a step towards reducing the associated uncertainties, and thus improving our understanding of these complex interactions and benefiting the next generation of long-baseline neutrino experiments. ANNIE will make use of LAPPDs to measure neutron multiplicity of CC-0$\pi$ $\nu_\mu$ interactions on oxygen, making it the first experiment to deploy an array of these photodetectors. Because the LAPPD is a novel photodetection technology, much customization is required to integrate it into existing electronics. The first half of this thesis covers the significant progress made towards the first deployment of the LAPPD system. From its test stand at Fermilab, the LAPPD system was systematically tested and put together until deployment readiness was achieved. I present my contributions to the design, fabrication, and testing of the waterproof housing and cables, and the commissioning of the LVHV board that powers the LAPPD and its readout electronics. These efforts brought the LAPPD system significantly closer to deployment, and eventually first data. The second half of this thesis presents the vertex and energy reconstruction algorithms developed to analysis the beam data with PMT-only information. While much progress has been made towards the deployment of LAPPDs, with several in the detector tank, efforts to integrate the LAPPD datastream are in progress. Thus, I developed a ring edge detection technique using PMT data to fit the muon vertex and determine its energy. The analysis in this thesis finds average neutron yields of $\Bar{n}_{data} = 0.452 \pm 0.039 (\text{stat}) \pm 0.27 (\text{sys})$ for a selection of muon neutrino candidates in the fiducial volume of ANNIE and corrected with an averaged neutron detection efficiency. An equivalent analysis for simulated beam data results in an average neutron yield of $\Bar{n}_{MC} = 0.582 \pm 0.018 (\text{stat}) \pm 0.25 (\text{sys})$. Future work includes application of efficiency corrections at a positional level, quantification of all systematic uncertainties, and neutron multiplicity measurements with other event topologies.

43 PARTICLE ACCELERATORS↗

Sulfur Pellets Responses to a Bare and Steel Reflected Pulse of the Oak Ridge National Laboratory Health Physics Research Reactor

The experiments analyzed in this report were conducted at the Health Physics Research Reactor (HPRR), also known as the $\textit{Fast Burst Reactor}$. The reactor was designed and built at Oak Ridge National Laboratory (ORNL) in 1961. The HPRR was an unmoderated, unshielded fast reactor that used highly enriched uranium and molybdenum alloy as fuel. The reactor was initially sent to the Nevada Test Site in 1962, where it was used to evaluate radiation doses received as a result of the Hiroshima and Nagasaki bombings during World War II. A few years later, the reactor was sent back to ORNL to be part of the Dosimetry Application Research (DOSAR) facility shown in Figure 1, which included a reactor building shown on the left (west) of the picture and a control and laboratory building in the upper right corner (northeast). The critical assembly was used for numerous technical studies, including systems calibration, dosimetry, radiobiology of plants and animals, testing of radiation alarms, as well as teaching and training in radiation dosimetry and nuclear engineering. Between 1963 and 1987, the HPRR was operated for thousands of hours, achieving criticality close to 10,000 times and motivating many publications. The HPRR was decommissioned in 1987. The goal of this effort was to use historical data from operation of the HPRR to create a criticality accident alarm system (CAAS) benchmark to be included in the $\textit{International Handbook of Evaluated Criticality Safety Benchmark Experiments}$ (ICSBEP Handbook). A thorough inspection was performed of all available documentation and information available. The most promising experiments that were selected for evaluation were those described in the 1987 ORNL report entitled $\textit{Health Physics Research Reactor Reference Dosimetry}$, ORNL-6240. The report includes reference dosimetry results of the shielded and unshielded configurations of the HPRR after burst operations. Because of changes to the reactor positioning and storage systems that were made in 1985, the previous dosimetry reports became obsolete, and the newly designed experiments were needed to create the HPRR’s adjusted dosimetry data. The various results reported in ORNL-6240 include reference doses and dose equivalents from different conventions at different distances and elevations as determined using the detected neutron fluence and conversion factors. The HPRR neutron fluence was obtained through different methods, including sulfur pellet analysis and threshold detector unit data. Information about the HPRR spectrum was also obtained through Bonner sphere measurements. This benchmark is focused on a part of the measured sulfur fluences reported in Appendix H of ORNL-6240. Standard commercial sulfur pellets were placed at different distances from the HPRR centerline during burst operation and were activated due to the 32 S(n,p) 32 P reaction. The resulting 32 P activity was then measured and the information about the corresponding sulfur fluence and/or neutron dose could be extracted. Many of those measurements have 7 been performed with the HPRR in its bare configuration or with different shields (combinations of Lucite, concrete, steel). All the necessary, precise information about material and/or dimensions of the different shields was not found, so it was decided to focus only on the unshielded and steel-shielded configurations to minimize the benchmark uncertainty. A total of 31 cases (24 unshielded and 7 shielded cases at different positions) of sulfur fluence were selected before evaluation to develop the benchmark.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Design for Thermal/Epithermal eXperiments (TEX) with Chloride Absorbers to Provide Validation Benchmarks for Y-12 Electrorefining Facility

Uranium electrorefining operations at Y-12 require validation for chlorine absorption and reflection. Plutonium chloride solution operations at Los Alamos National Laboratory require chlorine absorption validation. The growing need for chlorine validation is evident to the wider criticality safety community, with multiple attendees at the recent TEX 2.0 meeting at Lawrence Livermore National Laboratory (May 2023) requesting validation for chlorine (Idaho National Laboratory (INL), Institute de radioprotection et de surete nucleaire (IRSN), Savannah River Nuclear Site (SRNS), LANL, and Y-12). Los Alamos National Laboratory has recently performed, and benchmarked, an experiment titled Chlorine Worth Study (CWS) for the internal operations at the lab, but due to the difficulties in precisely characterizing the material compositions of the chlorine absorbers it is advantageous to perform a complimentary study with a different chlorine-based absorber material. Furthermore, having a uranium-based vs plutonium-based experiment provides a separate and important validation basis for criticality safety and nuclear data evaluation. The original final design report for the study of chlorine absorption using the TEX-HEU experimental base was presented in 2022, but used the same chlorine-bearing materials that were found to be difficult to characterize in the LANL benchmark. A complete redesign of the experiment has been performed looking at alternative absorber materials in various forms to produce an experiment that is fully characterizable. This report presents five novel chlorine experiments using the TEX-HEU test bed which provides direct comparison to the Y-12 and INL/Terrapower application needs, utilizing sodium chloride (NaCl) absorber plates. The absorber plates will consist of granulated NaCl (≥99.5% pure), which will be fully encapsulated in aluminum tins, providing a simple but effective chlorine-based absorber material that can be completely characterized. Of the five configurations presented in this report, it is expected that two or three configurations will be down selected for the actual experiment, with the other configurations being alternates. Three of the configurations are in the standard configuration, where the absorber is placed directly on the HEU fuel plates, and two in the sandwich configuration, where the absorber is surrounded by polyethylene moderators to force additional neutron thermalization prior to reaching the absorber. There are two thicknesses of NaCl absorber plates: 3/16” and 1/4” active thicknesses (i.e. not including the encapsulation). Both variations of the absorbers have an active absorber radius of 6” and a total radius of 7.5” to match the diameter of the HEU plates, with the outer 1.5” being aluminum encapsulation. The high-density polyethylene (HDPE) moderators are of the thicknesses: 27/16”, 7/4”, 1/8”, 11/16”, and 3/4”. The final configurations have six (one sandwich and one standard configuration), eight (one sandwich and one standard configuration), and 18 total fuel layers (standard configuration). The standard and sandwich configurations were designed such that the differences in moderator thicknesses are 1” HDPE, which were already procured for the original CED-2. The proposed configurations were precisely tuned to closely match the sensitivity profiles and neutron spectra of the Y-12 upset cases and were also compared to the INL/Terrapower upset cases. The assessment of experimental uncertainties of the non-absorber components was predicted to be 0.00114 Δk eff . The assessment of uncertainties resulting from the absorbers was predicted to be 0.00029 Δk eff . This results in a total uncertainty of 0.00118 Δk eff . Many of the largest uncertainties, namely the moderator densities, may be reduced with precision dimensional inspection of the components. The 1” HDPE moderators as well as the HDPE reflectors from the original CED-2 were incorporated in the final designs presented here. Additional HDPE moderator plates must be fabricated to complete the configurations. NaCl absorber plates will by fabricated at LLNL. The total additional cost is expected to be $\$$54,250 for the remaining components. Precise inspection, including dimensional, mass, density, and impurity, is recommended for all components. LLNL estimates that these costs are around $\$$12,000. It is expected, based on previous TEX-HEU experiments, that three weeks of experimental facility time is needed to complete the experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Use of Lignin-Based Admixture as Water Reducer (WRA) for Tailoring the Rheological Properties of Mortars for 3D-Printing

Efforts towards decarbonizing construction materials and industrial processes related to cement and concrete can be aided via multifaceted approaches that target alternative admixtures as well as precision control of fabrication. Chemical admixtures for water reduction have played a crucial role in the development of advanced mortar and concrete mixtures. Newer biomass processing techniques developed for aviation fuel production from corn stover biomass produce a highly reactive lignin byproduct that is suitable for chemical modifications to mimic the properties of commonly used polycarboxylate ethers (PCEs) with a smaller carbon footprint. These lignin-based plasticizers developed at NREL can be used in place of petrochemical-derived superplasticizers to tailor the rheological properties of cement-based systems for applications such as additive manufacturing while reducing the carbon intensity of the concrete mix. Lignosulfonates derived from paper pulping were historically used as water reducers only to be displaced with the rise of PCEs. The present study examines the use of a NREL produced lignin-based water reducing admixture (WRA), in cement pastes and mortar mixtures for 3D-printing at small- (mm) scale. The experimental program consisted of different formulations of oxidized lignin-based WRAs added in variable dosages to cement pastes with a fixed water-to-cement ratio. The objective is to achieve an appropriate workability, extrudability and buildability of mortar mixtures to produce 3D-printed specimens. The rheological characterization was performed to compare the initial yield stress and viscosity of the different mixtures with lignin-based admixture with respect to conventional PCE superplasticizers. The rheological characterization shows that the proposed material act as an effective water-reducer in cement systems, affecting the yield stress, plastic viscosity, and structuration rate of the mixtures evaluated. On the other hand, the effect on early hydration process of the cement pastes containing lignin-based admixtures is comparable to conventional superplasticizers.

3D-printing↗

Integration of the FastIC front-end electronics into the Picosec MicroMegas detector

The Picosec MicroMegas collaboration aims to develop gaseous fast-timing detectors; experimentally, intrinsic time resolutions from around 50 ps to better than 20 ps are obtained, depending on the exact detector configuration. Parts of developments focus on exploring various options of fast-timing multi-channel front-end electronics, to meet the data processing demands of experimental applications. One option is the FastIC, which was developed for reading out positive and negative input polarity sensors with intrinsic amplification. In this paper, the first results from reading out the gaseous Picosec MicroMegas detector with the FastIC are presented. In laboratory studies, a basic description of the data processing chain was performed using a function generator. The results from test beam measurements are used to characterise the timing performance and the charge processing of the combination of FastIC and Picosec MicroMegas, as well as to demonstrate the possibility of a multi-channel detector readout. Although the timing-at-threshold level of the FastIC introduces a time walk of around 1.5 ns, time resolutions of around 50 ps have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗