Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “photon statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The (55)Fe X-ray Energy Response of Mercury Cadmium Telluride Near-Infrared Detector Arrays

The accurate determination of a detector's fundamental parameters, including read noise, dark current, and QE, relies on a proper measurement of a detector's conversion gain (e- ADU(exp -1)). Charge coupling effects, such as interpixel capacitance, attenuate photon shot noise and result in an overestimation of conversion gain when implementing the photon transfer technique. An approach involving (55)Fe X-rays provides a potentially straightforward measurement of conversion gain by comparing the observed instrumental counts (ADU) to the known charge (e-) liberated by the X-ray. This technique is already preferred within the CCD community, as the pair production energy for silicon is well established. In contrast, to date the pair production energy is unknown for HgCdTe, a material commonly used for near-infrared detectors. In this paper, we derive a preliminary calibration of the (55)Fe X-ray energy response of HgCdTe using 8 HST WFC3 1.7 micrometers flight grade detectors. Our conversion of the X-ray intensities from counts into electrons implements a technique that restores the 'true' gain via classical propagation of errors. For these detectors, our analysis yields preliminary results of good statistical precision: each Ka event generates 1849 +/- 46 electrons, which corresponds to a pair production energy of 3.21+/-f 0.08 eV. We are continuing to assess potential systematic effects to further refine the accuracy of this result.

Fox, Ori↗

Wavelength- and irradiance-dependent changes in intracellular nitric oxide level

Photobiomodulation (PBM) refers to beneficial effects of low energy light absorption. Although there is a large and growing body of literature describing down-stream physiological benefits of PBM, there is limited understanding of the molecular mechanisms that initiate and mediate these effects at the level of photon absorption. At present, the leading hypothesis is that light absorption induces release of nitric oxide (NO) from the active site of cytochrome c oxidase (COX), allowing it to bind O 2 instead. This is believed to increase mitochondrial respiration, and result in greater overall health of the cell due to increased ATP production. Aim: Although NO itself is a powerful signaling molecule involved in a host of biological responses, less attention has been devoted to the mechanisms of NO release and subsequent effects on cell signaling. The purpose of this work is to investigate wavelength-specific effects on intracellular NO release in living cells. Approach: We have conducted in depth dosimetry analyses of NO production and function in an in vitro retinal model in response to low energy exposure to one or more wavelengths of laser light. Results: We found statistically significant wavelength-dependent elevations (10-30%) in intracellular NO levels following laser exposures at 447, 532, 635 or 808 nm. Sequential or simultaneous exposures to light at two different wavelengths enhanced the NO modulation up to 50% of unexposed controls. Additionally, the immediate increases in cellular NO levels were independent of the function of nitric oxide synthase, depended greatly on the substrate source of electrons entering the electron transport chain, and did not result in increased levels of cGMP. Conclusions: This study concludes the simple model of light-mediated release of NO from COX is unlikely to explain the wide variety of PBM effects reported in the literature. Our multi-wavelength method provides a novel tool for studying immediate and early mechanisms of PBM, as well as exploring intracellular NO signaling networks.

59 BASIC BIOLOGICAL SCIENCES↗

Single-Particle Studies Reveal a Nanoscale Mechanism for Elastic, Bright, and Repeatable ZnS:Mn Mechanoluminescence in a Low-Pressure Regime

Mechanoluminescent materials, which emit light in response to elastic deformation, are demanded for use as in situ stress sensors. ZnS doped with Mn is known to exhibit one of the lowest reported thresholds for appearance of mechanoluminescence, with repeatable light emission under contact pressure <10 MPa. Here, the physical basis for such behavior remains as yet unclear. Here, reliable microscopic detection of mechanoluminescence of single ZnS:Mn microparticles, in combination with nanoscale structural characterization, provides evidence that the mechanoluminescent properties of these particles result from interplay between a non-centrosymmetric crystal lattice and its defects, viz., dislocations and stacking faults. Statistical analysis of the distributions of mechanoluminescence energy release trajectories reveals two distinct mechanisms of excitation: one attributable to a piezo-phototronic effect and the other due to dislocation motion. At pressures below 8.1 MPa, both mechanisms contribute to mechanoluminescent output, with a dominant contribution from the piezo-phototronic mechanism. In contrast, above 8.1 MPa, dislocation motion is the primary excitation source. For the piezo-phototronic mechanism, we propose a specific model that accounts for elastic ZnS:Mn mechanoluminescence under very low pressure. The charged interfaces in stacking faults lead to the presence of filled traps, which otherwise would be empty in the absence of the built-in electric field. Upon application of external stress, local enhancement of the piezoelectric field at the stacking faults’ interfaces facilitates release of the trapped carriers and subsequent luminescence. This field enhancement explains how <10 MPa pressure produces thousands of photons.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Limits on X-Ray Polarization at the Core of Centaurus A as Observed with the Imaging X-Ray Polarimetry Explorer

We present measurements of the polarization of X-rays in the 2–8 keV band from the nucleus of the radio galaxy Centaurus A (Cen A), using a 100 ks observation from the Imaging X-ray Polarimetry Explorer (IXPE). Nearly simultaneous observations of Cen A were also taken with the Swift, NuSTAR, and INTEGRAL observatories. No statistically significant degree of polarization is detected with IXPE. These observations have a minimum detectable polarization at 99% confidence (MDP 99 ) of 6.5% using a weighted, spectral model-independent calculation in the 2–8 keV band. The polarization angle ψ is consequently unconstrained. Spectral fitting across three orders of magnitude in X-ray energy (0.3–400 keV) demonstrates that the SED of Cen A is well described by a simple power law with moderate intrinsic absorption (N H ~ 10 23 cm -2 ) and a Fe Kα emission line, although a second unabsorbed power law is required to account for the observed spectrum at energies below 2 keV. This spectrum suggests that the reprocessing material responsible for this emission line is optically thin and distant from the central black hole. Our upper limits on the X-ray polarization are consistent with the predictions of Compton scattering, although the specific seed photon population responsible for the production of the X-rays cannot be identified. The low polarization degree, variability in the core emission, and the relative lack of variability in the Fe Kα emission line support a picture where electrons are accelerated in a region of highly disordered magnetic fields surrounding the innermost jet.

79 ASTRONOMY AND ASTROPHYSICS↗

Constraining the High-Energy Emission from Gamma-Ray Bursts with Fermi

We examine 288 GRBs detected by the Fermi Gamma-ray Space Telescope's Gamma-ray Burst Monitor (GBM) that fell within the field-of-view of Fermi's Large Area Telescope (LAT) during the first 2.5 years of observations, which showed no evidence for emission above 100 MeV. We report the photon flux upper limits in the 0.1-10 GeV range during the prompt emission phase as well as for fixed 30 s and 100 s integrations starting from the trigger time for each burst. We compare these limits with the fluxes that would be expected from extrapolations of spectral fits presented in the first GBM spectral catalog and infer that roughly half of the GBM-detected bursts either require spectral breaks between the GBM and LAT energy bands or have intrinsically steeper spectra above the peak of the nuF(sub v) spectra (E(sub pk)). In order to distinguish between these two scenarios, we perform joint GBM and LAT spectral fits to the 30 brightest GBM-detected bursts and find that a majority of these bursts are indeed softer above E(sub pk) than would be inferred from fitting the GBM data alone. Approximately 20% of this spectroscopic subsample show statistically significant evidence for a cut-off in their high-energy spectra, which if assumed to be due to gamma gamma attenuation, places limits on the maximum Lorentz factor associated with the relativistic outflow producing this emission. All of these latter bursts have maximum Lorentz factor estimates that are well below the minimum Lorentz factors calculated for LAT-detected GRBs, revealing a wide distribution in the bulk Lorentz factor of GRB outflows and indicating that LAT-detected bursts may represent the high end of this distribution.

Gehrels, Neil↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nonlinear wavepacket dynamics in proximity to a stationary inflection point

A stationary inflection point (SIP) in the Bloch dispersion relation of a periodic waveguide is an exceptional point degeneracy where three Bloch eigenmodes coalesce, forming the so-called frozen mode with a divergent amplitude and vanishing group velocity of its propagating component. For this work, we have developed a theoretical framework to study the time evolution of wavepackets centered at an SIP. Analysis of the evolution of the statistical moment distribution of linear pulses shows a strong deviation from the conventional ballistic wavepacket dynamics in dispersive media. The presence of nonlinear interactions dramatically changes the situation, resulting in a mostly ballistic propagation of nonlinear wavepackets with the speed and even the direction of propagation essentially dependent on the wavepacket amplitude. Such a behavior is unique to nonlinear wavepackets centered at an SIP and can be used for the realization of a novel family of beam power routers for classical waves.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Constraining the dark matter contribution of $\gamma$ rays in clusters of galaxies using Fermi -LAT data

Clusters of galaxies are the largest gravitationally bound systems in the Universe. Their dynamics are dominated by dark matter (DM), which makes them among the best targets for indirect DM searches. We analyze 12 years of data collected by the Fermi Large Area Telescope (Fermi-LAT) in the direction of 49 clusters of galaxies selected for their proximity to the Earth and their high x-ray flux, which makes them the most promising targets. We first create physically motivated models for the DM density around each cluster considering different assumptions for the substructure distribution. Then we perform a combined search for a $\gamma$-ray signal in the Fermi-LAT data between 500 MeV and 1 TeV. We find a signal of $\gamma$ rays potentially associated with DM that is at a statistical significance of 2.5⁢σ-3.0⁢σ when considering a slope for the subhalo mass distribution α =1.9 and minimum mass of M min =10 -6⁢ M ⊙ . The best-fit DM mass and annihilation cross sections for a b⁢$\overline{b}$ annihilation channel are m X =40–60 GeV and $\langle$σ⁢ν$\rangle$=(2–4)×10 -25 cm 3 /s. When we consider α =2.0 and M min =10 -9⁢ M ⊙ , the best fit of the cross section reduces to $\langle$σ⁢ν$\rangle$=(4–10)×10 -26 cm 3 /s. For both DM substructure models there is a tension between the values of $\langle$σ⁢ν$\rangle$ that we find and the upper limits obtained with the nondetection of a $\gamma$-ray flux from Milky Way dwarf spheroidal galaxies. In conclusion, this signal is thus more likely associated with $\gamma$ rays produced in the intracluster region by cosmic rays colliding with gas and photon fields.

79 ASTRONOMY AND ASTROPHYSICS↗

Low-dosage micronized 17 beta-estradiol prevents bone loss in postmenopausal women

With the use of a double-blind, randomized, dose-ranging design, we tested during an 18-month period the degree of protection against postmenopausal bone loss afforded by micronized 17 beta-estradiol in dosages of 0.5, 1.0, and 2.0 mg. All subjects received supplementation to ensure a minimum of 1500 mg calcium daily. Fifty-one subjects completed at least 1 year of follow-up bone density measurements by quantitative computed tomography and by single- and dual-photon absorptiometry. In the placebo group spinal trabecular bone density decreased 4.9% annually (p less than 0.001), whereas in those taking micronized 17 beta-estradiol bone density tended to increase (annual increases of 0.3% in the 0.5 mg micronized 17 beta-estradiol group, 1.8% in the 1.0 mg micronized 17 beta-estradiol group, and 2.5% in the 2.0 mg micronized 17 beta-estradiol group). After completing the double-blind phase, 41 subjects completed an additional 18 months of follow-up while taking 1.0 mg micronized 17 beta-estradiol. During this time one third of the subjects were randomly assigned to discontinue calcium supplements. Among those who previously received placebo, trabecular bone density increased 4.3% annually, whereas among those who had used micronized 17 beta-estradiol, trabecular bone density response was inversely related to the dosage previously used. Additionally and independently, the level of calcium intake showed a statistically significant correlation with the change in spinal trabecular bone density (r = 0.37, p = 0.02). We conclude that micronized 17 beta-estradiol has a continuous skeletal dose-response effect in the range of 0.5 to 2.0 mg and that calcium intake positively modifies the skeletal response to 1.0 mg micronized 17 beta-estradiol.

Randomized Controlled Trial↗

Cloud Structure and Cloud-Radiation Interaction: From Smallest Observable Scales (Less than 10 m) to GCM Grid Scales (More than 100 km)

In this presentation we review the fractal nature of internal cloud structure from cm- to km-scales as captured by in-situ probes during long horizontal penetrations by aircraft. We uncover the non-Poissonian spatial distribution of cloud droplets at submeter scales and confirm scale-invariant behavior for large scales. Based on these structural characteristics, we generate simple fractal cloud models that reproduce statistical scaling properties of real clouds. These stochastic models represent a link between nonlinear science, in general, and cloud-radiation interaction, in particular. Next we run three-dimensional radiative transfer computations on these synthetic fractal clouds and compare the structure of the resulting radiation fields with the known structure of the cloud model and with satellite images of real clouds. The different behaviors observed for small and large-scale variabilities will be discussed in detail. We find that while the large-scale fluctuations of the resulting radiation fields resemble those in the original scale-invariant cloud structure, the radiation at small scales is much smoother than its cloud liquid water counterpart. This violates scale-invariance and produces a scale-break at 0.2-0.5 km that is clearly observed in high-resolution satellite data such as from Landsat. Finally, we show how radiative transfer Green function theory in the photon diffusion limit explains (and predicts) the above phenomena of "radiative smoothing."

Marshak, Alexander↗

Low-dose high-resolution $\mathrm{TOF}$-$\mathrm{PET}$ using ionization-activated multi-state low-$\mathrm{Z}$ detector media

We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a ‘Switchillator’, that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Noise from undetected sources in Dark Energy Survey images

ABSTRACT For ground-based optical imaging with current CCD technology, the Poisson fluctuations in source and sky background photon arrivals dominate the noise budget and are readily estimated. Another component of noise, however, is the signal from the undetected population of stars and galaxies. Using injection of artifical galaxies into images, we demonstrate that the measured variance of galaxy moments (used for weak gravitational lensing measurements) in Dark Energy Survey (DES) images is significantly in excess of the Poisson predictions, by up to 30 per cent, and that the background sky levels are overestimated by current software. By cross-correlating distinct images of ‘empty’ sky regions, we establish that there is a significant image noise contribution from undetected static sources (US), which, on average, are mildly resolved at DES resolution. Treating these US as a stationary noise source, we compute a correction to the moment covariance matrix expected from Poisson noise. The corrected covariance matrix matches the moment variances measured on the injected DES images to within 5 per cent. Thus, we have an empirical method to statistically account for US in weak lensing measurements, rather than requiring extremely deep sky simulations. We also find that local sky determinations can remove most of the bias in flux measurements, at a small penalty in additional, but quantifiable, noise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RTN-056: Study of the Photon Transfer Curve in the CCD detectors of the Vera C. Rubin Observatory

The RECA internship program provides Colombian students with an opportunity to enhance their research skills in Astronomy, Astrophysics, and Cosmology. During this three-month program, our main objective was to study the Photon Transfer Curves (PTC) of the Vera C. Rubin Observatory, specifically the gain, and to compare it with the gain obtained through pairs of flats. Overall, the study of PTCs is crucial in understanding the performance of detectors and instruments used in Astronomy. The Vera C. Rubin Observatory is an important facility that will enable researchers to carry out a wide range of studies in this field, making it essential to investigate its gain performance. We used run 13144 to construct the PTCs and 13186 to analyze the crosstalk. We employed the LSST Science Pipelines (also known as the DM stack), a software under development for this observatory, which performs all the necessary reductions for the construction of the PTCs. We also used simulations to replicate the observed effects. Initially, we found a 5% difference between the gain calculated by PTC and pairs of flats for a flow range between 5000 and 10000 ADU. Simulations showed that this difference was due to the handling of statistics and the assumption that the distribution following the Lupton equation is Gaussian. We found an error interval for this flow region based on the vendor, with (1.8 ± 0.7, 4.1 ± 0.9) % for E2V and (0.85 ± 0.7, 2.2 ± 0.9) % for ITL. From the PTC, we also obtained the average Full Well Capacity of LSSTCam as 130000 ± 10000$ electrons. We identified a list of segments where we found differences with the results obtained by SLAC National Acceleration Laboratory in PTC parameters, low saturation level, or other defects. We detected and corrected the effect of statistics in the gain calculation using pairs of flats and proposed a code change, which was implemented in the pipeline software. We do not recommend correcting for crosstalk as it does not significantly affect the parameters and does not change the shape of the PTC. However, the opposite is true for the nonlinearity correction.

79 ASTRONOMY AND ASTROPHYSICS↗

Reduced vertebral bone density in hypercalciuric nephrolithiasis

Dual-energy x-ray absorptiometry and single-photon absorptiometry were used to determine bone density at the lumbar spine and radial shaft in 62 patients with absorptive hypercalciuria, 27 patients with fasting hypercalciuria, and 31 nonhypercalciuric stone formers. Lumbar bone density was significantly lower in patients with absorptive (-10%) as well as in those with fasting hypercalciuria (-12%), with 74 and 92% of patients displaying values below the normal mean, whereas only 48% of the nonhypercalciuric stone formers had bone density values below the normal mean. In contrast, radial bone density was similar in all three groups of renal stone formers investigated. The comparison of urinary chemistry in patients with absorptive hypercalciuria and low normal bone density compared to those with high normal bone density showed a significantly increased 24 h urinary calcium excretion on random diet and a trend toward a higher 24 h urinary uric acid excretion and a higher body mass index in patients with low normal bone density. Moreover, among the patients with absorptive hypercalciuria we found a statistically significant correlation between the spinal bone density and the 24 h sodium and sulfate excretion and the urinary pH. These results gave evidence for an additional role of environmental factors (sodium and animal proteins) in the pathogenesis of bone loss in absorptive hypercalciuria. In conclusion, our data suggest an osteopenia of trabecular-rich bone tissues in patients with fasting and absorptive hypercalciurias.

Non-NASA Center↗

Characterization of a SiPM-based monolithic neutron scatter camera using dark counts

The Single Volume Scatter Camera (SVSC) Collaboration aims to develop portable neutron imaging systems for a variety of applications in nuclear non-proliferation. Conventional double-scatter neutron imagers are composed of several separate detector volumes organized in at least two planes. A neutron must scatter in two of these detector volumes for its initial trajectory to be reconstructed. As such, these systems typically have a large footprint and poor geometric efficiency. We report on the design and characterization of a prototype monolithic neutron scatter camera that is intended to significantly improve upon the geometrical shortcomings of conventional neutron cameras. The detector consists of a 50 mm×56 mm× 60 mm monolithic block of EJ-204 plastic scintillator instrumented on two faces with arrays of 64 Hamamatsu S13360-6075PE silicon photomultipliers (SiPMs). The electronic crosstalk is limited to < 5% between adjacent channels and < 0.1% between all other channel pairs. SiPMs introduce a significantly elevated dark count rate over PMTs, as well as correlated noise from after-pulsing and optical crosstalk. In this article, we characterize the dark count rate and optical crosstalk and present a modified event reconstruction likelihood function that accounts for them. We find that the average dark count rate per SiPM is 4.3 MHz with a standard deviation of 1.5 MHz among devices. The analysis method we employ to measure internal optical crosstalk also naturally yields the mean and width of the single-electron pulse height. Here, we calculate separate contributions to the width of the single-electron pulse-height from electronic noise and avalanche fluctuations. We demonstrate a timing resolution for a single-photon pulse to be (128 ± 4) ps. Finally, coincidence analysis is employed to measure external (pixel-to-pixel) optical crosstalk. We present a map of the average external crosstalk probability between 2×4 groups of SiPMs, as well as the in-situ timing characteristics extracted from the coincidence analysis. Further work is needed to characterize the performance of the camera at reconstructing single- and double-site interactions, as well as image reconstruction.

47 OTHER INSTRUMENTATION↗

Measuring the Beam-Spin Asymmetry of Hard Exclusive ¿0 Production off the Neutron with CLAS12

Over the course of the last couple of decades, Generalised Parton Distributions (GPDs) have become a compelling area of focus in both theoretical and experimental research in the ?eld of hadronic structure. GPDs can be indirectly accessed via observables in hard exclusive reactions such as Deeply Virtual Compton Scattering (DVCS) and Deeply Virtual Meson Production (DVMP). In these reactions, an incident lepton scatters o? an individual quark within the target nucleon via the exchange of a virtual photon, and a real photon (DVCS) or a meson (DVMP) are emitted as a result. This thesis presents an analysis of Deeply Virtual ?0 Meson Production o? the neutron in the deuteron (nDV?0P). The data were taken with the CLAS12 detector, which is housed in the experimental Hall B at the Je?erson National Laboratory (JLab) in Virginia, USA. A longitudinally polarised electron beam delivered by JLab?s Continuous Electron Beam accelerator Facility (CEBAF), at an energy of 10.2 and 10.6 GeV, was incident on a liquid deuterium target housed within the CLAS12 detector assembly. The nDV?0P channel is sensitive to the lesser-studied chiral-odd transversity GPDs. GPDs are accessed indirectly via observables related to the cross-sections of hard exclusive processes. One such example is the beam-spin asymmetry (?LU) as a function of Trento-?, the angle between the leptonic plane and the hadronic plane which are de?ned with the beam and scattered electron, and with the recoiling neutron and reconstructed ?0, respectively. Despite the limited statistics, the observable ?LU was successfully extracted for eight kinematic bins (four in Mandelstam ?, and two in ??). This is a ?rst measurement for nDV?0P in the phase-space which is now available with CLAS12 in the 12 GeV era of JLab.

Naidoo, Paul↗

Sensitivity and uncertainty analysis of PWR spent fuel observables to operational and model parameters

Sensitivity and uncertainty analyses of spent nuclear fuel (SNF) observables - decay heat, neutron and γ-ray emission rate - to operational and model parameters have been performed. A 2D model representing a typical PWR 17x17 UO{sub 2} fuel assembly has been taken as reference. The Serpent code and ENDF/B-VII.1 evaluated nuclear data library have been used for the analyses. Relative uncertainty of decay heat, neutron and γ-ray emission rates due to Monte Carlo counting statistics, as well as the number of fuel pin radial regions required for an accurate characterization of SNF neutron emission, have been estimated. A parametric study has been carried out to investigate the impact of the homogenization to an average value of the fuel and moderator temperature, boron concentration power and burnup on the prediction of the selected observables. In addition, linear sensitivity coefficients have been calculated. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Optimizing Science Return from Plato's Observations of the Kepler Field

The Plato mission could substantially enhance its scientific yield by focusing a significant fraction of its observations with all 24 cameras viewing the Kepler Field of View (FOV). Kepler, while exceptionally productive, did not accomplish its goal of providing a direct measurement of the abundance of Earth-analog planet around sunlike stars. On this issue, Plato observations centered on the Kepler FOV would enable planet searches using the combined data sets to achieve more precise estimates of planetary occurrence rates than obtainable using data from either mission alone. The ecliptic latitude of the Kepler FOV is too low for Plato to observe with 24 cameras year-round, so current plan’s for Plato’s Northern Stare places the Kepler FOV in the periphery, reducing the number of photons collected from Kepler targets by factors of 2 or 4. We propose instead four ~6 - 8 month Plato stares with 24 cameras observing the Kepler FOV during the Plato primary mission, instead of a single 2 year stare with the Kepler FOV located to the periphery. This change would greatly increase the amount of 'Plato glass’ dedicated to the continued study of the Kepler FOV, while still enabling Plato to observe other parts of the sky during the majority of its prime mission. In addition to discovering planets below Kepler's detection threshold, this change would yield transit follow-up of thousands of known exoplanets with an effective throughput of a 0.6 m space telescope. It would also extend the observing baseline of the Kepler FOV to timescales of decades, providing key data for stellar cycles, the analysis of transit timing variations, and other decade-timescale variations. Such a campaign enhances the likelihood of the detection of true Earth-analog transiting planet candidates around sunlike stars, provide the best statistical study of exoplanet systems with transit timing variations and duration variations, and open up the study of stellar variability to new time-domains with precision on large numbers of faint targets that only 24 Plato cameras can provide.

Jack Lissauer↗