Absorbing the Sun: Operational Practices and Balancing Reserves in Florida's Municipal Utilities

The Florida Reliability Coordinating Council (FRCC) power system is comprised of multiple balancing authorities ranging in size from Gainesville Regional Utilities (GRU) with a 2019 summer net firm demand of 429 MW to Florida Power & Light with a 2019 summer net firm demand of 22,510 MW; and including cooperative, municipal, and investor-owned utilities. As all of these balancing authorities are and have plants to continue installing significant quantities of utility-scale solar photovoltaics, one relevant question is how much operating reserves they will need to hold as solar penetrations increase. While there are estimates of how regulating and flexibility reserve requirements change with solar penetration, the literature almost exclusively focuses on large balancing authorities with sub-hourly dispatch. In this work we analyze how reserve needs change not only with solar photovoltaic penetration, but also balancing authority size and operational practices. We find that, measured as a fraction of load, smaller balancing authorities with less frequent load and solar forecasts and less frequent dispatch need more reserves. Such utilities' reserve needs also increase more with increasing solar deployment as compared to larger or more frequently dispatched balancing authorities. These impacts are most acute for GRU. We find that moving from day-ahead to hour-ahead load and solar forecasting and system dispatch could enable GRU to incorporate 32% solar generation with median reserves at 20% instead of 60% of load; and that median reserve needs could drop further to about 10% of load if Florida's municipal utilities formed a reserve sharing group and moved to sub-hourly dispatch.

balancing authority↗

EMT Models to Evaluate Traveling Wave-Based Protection in Distribution System

The distribution system is going through significant changes. One of them is the high penetration of inverter-based distributed energy resources in the distribution system. Due to this high penetration, there is a need for a better protection system. Multiple organizations are working on creating novel protection techniques for distribution systems with high penetration of inverter-based DERs. One such innovative method is the use of traveling waves to detect and locate faults. Transmission system protection utilizes this approach, and commercial solutions exist for the transmission system. Using this approach in the distribution system is not straightforward and presents some challenges for implementation. This presentation will discuss the need for using wide-band models to model the traveling wave phenomenon in the distribution system.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Multi-layered Resilient Microgrid Networks

Distribution grid resilience, especially when the grid is under high penetration of Distributed Energy Resources (DER), e.g. PV and energy storage, is essential to ensure the quality of electric power services. The resiliency aspect is particularly important for critical loads that typically include hospitals, police/fire stations, and national security facilities. Networks of multiple interconnected reconfigurable microgrids help to increase renewable energy penetration and may be used as basic building blocks for implementing future resilient power grids. However, this integration requires additional layers of communications, both horizontal and vertical, which may substantially increase the potential cyber attack surfaces as well as escalate risks for wide-spread malfunctions of automation systems. The Mulit-layered Resilient Microgrid Networks project is an industry-academic collaboration between ABB, Duke Energy and the University of Illinois at Urbana-Champaign (UIUC) that has developed and demonstrated a cyber-physical resilient control and communication architecture for deployment of multiple microgrid networks, as well as retrofitting the existing distribution grids by increasing DER penetration levels.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling and Analysing the Impact of Heat Pump Water Heaters on Distribution Systems Using GridLAB-D

With the constant increase in energy demand, finding ways to reduce peak load and the energy-costs factors has become more imperative. Domestic water heating showcases a significant opportunity for such applications. Water heating is the second-highest energy consumer in the residential sector across the United States. Electric Water Heaters (EWHs), in particular, constitute nearly 43% of American household water heating energy consumption. Heat Pump Water Heater (HPWH), on the other hand, are an advanced water heating technology that has recently emerged in the United States residential market. The objectives of this work are to develop a HPWH model and build a case study that evaluates various penetration levels of HPWH in providing reduced peak load and cost-effective energy savings for both utilities and customers. The HPWH model was developed and integrated within the GridLAB-D simulation environment. The model behavior was then validated against a real HPWH unit at Portland State University (PSU). The case studies incorporated five HPWH penetration levels, ranging from 20% to 100%. In each case, EWHs were replaced with HPWHs. The results showed that a high penetration level of HPWHs can reduce the energy consumption on a distribution system to 38%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Generating Sequential PV Deployment Scenarios for High Renewable Distribution Grid Planning: Preprint

This paper introduces a novel approach for generating solar photovoltaic (PV) plant deployment scenarios for grid integration planning. The approach guarantees consistency among scenarios of the same deployment by ensuring that higher penetration scenarios contain PV units deployed in lower penetration scenarios. It also constrains the size and spatial distribution of the PV plants and considers three placement types. A case study on a real-world distribution system proves that the precepts of scenario consistency, deployment diversity, and placement are met. The study further investigates the impact of the resulting scenarios via a stochastic hosting capacity analysis. Results indicate that the ratio between PV and load sizes, referred to as the nodal PV penetration factor (NPPF), is a key driver of the grid integration impact. By reducing the NPPF from 5 to 2, the maximum hosting capacity increased by at least 112%. The study also reveals that scenarios under random placement can lead to higher hosting capacity values.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Advanced control techniques for modern inertia based inverters

In this research three artificial intelligent (AI)-based techniques are proposed to regulate the voltage and frequency of a grid-connected inverter. The increase in the penetration of renewable energy sources (RESs) into the power grid has led to the increase in the penetration of fast-responding inertia-less power converters. The increase in the penetration of these power electronics converters changes the nature of the conventional grid, in which the existing kinetic inertia in the rotating parts of the enormous generators plays a vital role. The concept of virtual inertia control scheme is proposed to make the behavior of grid connected inverters more similar to the synchronous generators, by mimicking the mechanical behavior of a synchronous generator. Conventional control techniques lack to perform optimally in nonlinear, uncertain, inaccurate power grids. Besides, the decoupled control assumption in conventional VSGs makes them nonoptimal in resistive grids. The neural network predictive controller, the heuristic dynamic programming, and the dual heuristic dynamic programming techniques are presented in this research to overcome the draw backs of conventional VSGs. The nonlinear characteristics of neural networks, and the online training enable the proposed methods to perform as robust and optimal controllers. The simulation and the experimental laboratory prototype results are provided to demonstrate the effectiveness of the proposed techniques.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Assessment of the hydromechanical higher-order MPM for the simulation of geotechnical problems

The Material Point Method (MPM) has been increasingly used to simulate large strain deformations. Linear interpolation functions are commonly used to perform the spatial integration. It is well-known that the discontinuities in the interpolation function derivatives induce shock-like artifacts known as ‘cell-crossing’ error. These errors compound with volumetric locking errors when used with hydromechanical formulations for porous media, where different velocity fields are used for each phase. The capabilities of higher-order MPM frameworks have not been explored for real-scale geotechnical problems. As such, this paper aims to assess, validate, and further discuss a higher-order B-spline MPM (BS-MPM) framework. First, the BS-MPM framework is verified against the large-strain oedometer consolidation problem. Second, the framework is validated against a real-scale slope failure experiment triggered by pore water pressure recharge. Landslide features that are captured using the higher-order framework are specifically highlighted, and results (e.g., pore water pressure and deformation) are validated with field measurements. A generally convergent numerical solution is observed when using cubic interpolation functions. Third, a footing penetration problem is simulated using the multi-patch BS-MPM. Trends are examined with respect to penetration velocity and variation in hydraulic conductivity. The BS-MPM framework ultimately presents a stabilized numerical solution that captures plausible hydromechanical interaction trends important in geotechnical engineering applications.

36 MATERIALS SCIENCE↗

Data assimilation for combustion ignition delay time simulation using schlieren image velocimetry

This study sought to improve the accuracy of simulating spray penetration and combustion ignition delay by means of data assimilation (DA). The simulations were conducted using the Reynolds-averaged Navier–Stokes (RANS) equations and assimilating the schlieren image data. In DA, an ensemble square root filter (EnSRF) was used to build the statistical model, making the simulation results more accurate without any change in the governing equations. Recognizing that the spray-cone injection angle has a large effect on penetration, we created ensemble members with different injection angles. And we applied the two-component velocity distribution calculated via SIV and updated both velocity and temperature by using a DA statistical model derived from RANS ensemble simulations. The ignition delay time is generally known to vary even under the same experimental conditions because it is influenced by many factors. In this study, we attempted the transient DA-assisted RANS simulation to predict the ignition delay time even when the temporal resolution and accuracy of the observation data ware insufficient. Our trials offer an example of how a combination of techniques can be effectively used to assimilate experimental data obtained under restricted conditions.

Combustion simulation↗

Exploring the potential of hydrogen in decarbonizing China's light-duty vehicle market

The Chinese government has pledged to achieve overall carbon neutrality by 2060. Currently, the transportation sector contributes to about 10% of total greenhouse gas (GHG) emissions in China. Hence, China has created a well-defined energy vehicle development strategy to reduce GHG emissions from the transportation sector, further expanding into hydrogen vehicle technologies. In this study, the Transportation Energy Analysis Model (TEAM) investigates the potential of hydrogen internal combustion engine vehicles (H2- ICEVs) and fuel cell vehicles (FCEVs) as a reliable pathway towards the government's aspiration of carbon neutrality in the transportation sector. According to TEAM, by adopting FCEVs and H2-ICEVs in the vehicle market, hydrogen demand could reach 25% of the total light-duty transportation energy demand in 2050. Consequently, this will lead to an annual reduction of more than 35 million tons GHG compared to only counting on the electrification pathway in the decarbonization task. Besides, FCEVs would take longer to penetrate the light-duty vehicle market compared to H2-ICEVs, as the current fuel cell technology still requires much improvement to attain a competitive vehicle cost of production.

Life cycle analysis↗

Analysis of the laser welding keyhole using inline coherent imaging

Laser beam welding is a widely used fusion welding process in many industrial applications such as automotive, aerospace, energy, defense, and medical products. Industry has a fundamental need to model the laser welding process to minimize experimental testing and improve confidence in production welds. However, computational models attempting to predict weld formation are limited by an incomplete understanding of the beam-material interactions. As a consequence, these models do not accurately predict the mechanisms associated with laser weld formation. To improve the current state of prediction capabilities, it is vital to better detect/measure the physical aspects of the weld pool during high energy density welding. In this work, a novel real-time laser weld monitoring device using inline coherent imaging (ICI) was used to provide a fundamental understanding of laser weld formation via vaporization. The objective of this work was to investigate and quantify the relationship relating laser weld parameters and the vapor capillary (keyhole) through a state-of-the-art measurement technique. Bead-on-plate laser beam welds were produced with partial penetration on 304L stainless steel, 2205 duplex stainless steel, and Ti-6Al-4V. Keyhole monitoring was performed using a commercially available ICI system to collect keyhole penetration data in real time. These measurements were reconstructed to generate the vapor capillary shape at different welding parameters. Process parameters significantly influenced the keyhole shape and the keyhole root position relative to the process beam. Finally, the keyhole geometry showed distinct differences between the stainless steel alloys and Ti-6Al-4V.

2205↗

Tuning the Intrinsic Anisotropy with Disorder in the Ca K Fe 4 As 4 Superconductor

In this paper, we report on the anisotropy of the London penetration depth of CaKFe 4 As 4 , discussing how it relates to its electronic structure and how it modifies under introduction of disorder, both chemically induced (by Ni substitution) and irradiation induced (by 3.5-MeV protons). Indeed, CaKFe 4 As 4 is particularly suitable for the study of fundamental superconducting properties due to its stoichiometric composition, exhibiting clean-limit behavior in the pristine samples and having a fairly high critical temperature, T c ≈35 K. The London penetration depth λ L is measured with a microwave-coplanar-resonator technique that allows us to deconvolve the anisotropic contributions λ L,ab and λ L,c and obtain the anisotropy parameter γλ=λ L,c /λ L,ab . The γλ(T) found for the undoped pristine sample is in good agreement with previous literature and is here compared to ab initio density-functional-theory and Eliashberg calculations. The dependence of γλ(T) on both chemical and irradiation-induced disorder is discussed to highlight which method is more suitable to decrease the direction dependence of the electromagnetic properties while maintaining a high critical temperature. Lastly, the relevance of an intrinsic anisotropy such as γλ on application-related anisotropic parameters (critical current, pinning) is discussed in light of the recent employment of CaKFe 4 As 4 in the production of wires.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Scanning SQUID characterization of extremely overdoped La 2-x Sr x CuO 4

Recently, advances in film synthesis methods have enabled a study of extremely overdoped La 2 - x Sr x Cu O 4 . This has revealed a surprising behavior of the superfluid density as a function of doping and temperature, the explanation of which is vividly debated. One popular class of models posits electronic phase separation, where the superconducting phase fraction decreases with doping, while some competing phase (e.g., ferromagnetic) progressively takes over. A problem with this scenario is that all the way up to the dome edge the superconducting transition remains sharp, according to mutual inductance measurements. However, the physically relevant scale is the Pearl penetration depth Λ P , and this technique probes the sample on a length scale L that is much larger than Λ P . In the present paper, we use local scanning superconducting quantum interference device (SQUID) measurements that probe the susceptibility of the sample on the scale L << Λ P . Our SQUID maps show uniform landscapes of susceptibility and excellent overall agreement of the local penetration depth data with the bulk measurements. Overall, these results contribute an important piece to the puzzle of how high-temperature superconductivity vanishes on the overdoped side of the cuprate phase diagram.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Microwave Meissner screening properties of proximity-coupled topological-insulator / superconductor bilayers

The proximity-coupled topological-insulator / superconductor (TI/SC) bilayer system is a representative system to realize topological superconductivity. In order to better understand this unique state and enable future applications of the TI/SC bilayer, a comprehensive characterization and understanding of the microscopic properties of the bilayer are required. In this work, a microwave Meissner screening study, which exploits a high-precision microwave resonator technique, is conducted on the SmB 6 /YB 6 thin-film bilayers as an example TI/SC system. The study reveals spatially dependent electrodynamic screening response of the TI/SC system that is not accessible to other techniques, from which the corresponding microscopic properties of a TI/SC bilayer can be obtained. The TI thickness dependence of the effective penetration depth suggests the existence of a bulk insulating region in the TI layer. The spatially dependent electrodynamic screening model analysis provides an estimate for the characteristic lengths of the TI/SC bilayer: normal penetration depth, normal coherence length, and the thickness of the surface states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Soil architecture and subsurface stratigraphic heterogeneities across land-lake interfaces along Lake Erie.

Uploaded raw datasets from electrical resistivity tomography (ERT), ground penetrating radar (GPR), electromagnetic induction (EMI) and insitu sensors were acquired across land-lake interfaces along Lake Erie. These datasets were useful to delineate the soil architecture and subsurface stratigraphic heterogeneities. We combined multiple geophysical methods with lithostratigraphic logs from borehole cores and data from soil and borehole sensors to investigate spatial heterogeneities across land-lake interfaces. The apparent electrical conductivity (Eca) maps matched closely with the soil maps from public database and also detected additional soil units that were missing in the traditional soil maps. This implies that electromagnetic induction (EMI) could be relied upon for non invasive characterization of soils in sampling restricted sites where only non-invasive measurements are feasible. Results from electrical resistivity tomography (ERT) and Ground penetrating radar (GPR) are consistent with the surficial geology of the study area, and revealed that the vertical variabilities at the sites are mainly driven by stratigraphy.The ERT data (.stg) were acquired from three different sites portage river (PTR), crane creek (CRC) and old woman creek (OWC). The ".stg" files can be opened with ERT inversion software such as EarthImager, ResIpy or Res2DInv. The GPR data (.GPZ) were also acquired from the three sites, and the ".GPZ" data files can be opened with EKKO_project 5 software from Sensors & Software Inc., or with any other standard GPR software. The EM data (.csv) were acquired from the three sites while the soil sensor data (.csv) here were acquired only from crane creek site. The ".csv) files can be opened with MS Excel or any other spread sheet software.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Conservation Voltage Reduction under Inverter-Based VAR-Support [Slides]

Conservation voltage reduction (CVR) is a common technique used by utilities to strategically reduce demand during peak periods. As penetration levels of distributed generation (DG) continue to rise and advanced inverter capabilities become more common, it is unclear how the effectiveness of CVR will be impacted and how CVR interacts with advanced inverter functions. In this work, we investigated the mutual impacts of CVR and DG from photovoltaic (PV) systems (with and without autonomous Volt-VAR enabled). The analysis was conducted on an actual utility dataset, including a feeder model, measurement data from smart meters and intelligent reclosers, and metadata for more than 30 CVR events triggered by the utility over the year. The installed capacity of the modeled PV systems represented 66% of peak load, but reached instantaneous penetrations reached up to 2.5x the load consumption over the year. While the objectives of CVR and autonomous Volt-VAR are opposed to one another, this study found that their interactions were mostly inconsequential since the CVR events occurred when total PV output was low.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Large-Scale Hardware Experiment Demonstration of Operating High Inverter-Based Resource Power Systems With Grid-Forming Inverters

This paper presents experimental hardware results from a microgrid system as the penetration level of grid-forming (GFM) inverters increases. The experiment aims to showcase the advantages of GFM inverters in enhancing system stability and to investigate the operational challenges in systems relying entirely on inverter-based resources (IBRs). Five test scenarios are devised to progressively increase GFM inverter penetration levels: 0% (S1), 19% (S2), 37% (S3), 68% (S4), and 100% (S5). To ensure consistency, identical loading conditions and dynamic events are applied across all scenarios. The conducted tests include load step changes, output variation of grid-following (GFL) inverters during islanded mode, transition operations (such as synchronization to the grid and islanding), and rateof- change-of-frequency (ROCOF) and voltage jump tests during grid-connected mode. Key findings from the tests are summarized as follows: (1) Scenario S1 proved most challenging for load steps, and GFL variations because of insufficient GFM capacity, leaving the diesel generator unable to handle transient ridethrough; (2) Scenario S5 was the most difficult for transition operations, because the lack of a diesel generator to maintain stiff bus voltage resulted in unexpected reactive power flows during synchronization, causing the point of common coupling (PCC) breaker to trip; (3) Scenarios S4 and S5 were particularly challenging for ROCOF tests because of minimal system inertia, leading to large transients that triggered breaker trips; and (4) Scenario S4 exhibited the strongest voltage recovery capability because of the presence of the diesel generator and a higher number of GFM inverters, both of which possess the highest capacity for reactive power injection.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electromagnetic response of disordered superconducting cavities

We present the results for the resonant frequency shift and quality factor of disordered niobium (Nb) superconducting radio-frequency cavities driven out of equilibrium by the resonant microwave field. The theory is based on the non-equilibrium theory of superconductivity for the current response to the electromagnetic field at the vacuum–metal interface. We are able to accurately predict the observed frequency shifts with a precision of order fractions of kHz over the full temperature range 0 < T ≤ T c , including the negative frequency shift anomalies that are observed very near T c . The origin of these anomalies is shown to be the competition between the normal metal skin depth and the London penetration depth, which diverges as T→T c ⁻. An analytical approximation to the full current response, valid for |T-Tc| $\ll$ Tc, accounts for the negative frequency shift near T c . The non-monotonic dependence of the quality factor on the quasiparticle scattering rate is related to the pair-breaking effect of disorder on the superfluid fraction and, thus, the London penetration depth.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗