Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “particle filtering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Aseptic Operations for Post DHMR Processing of MOMA Mass Spectrometer

Mars Organic Molecule Analyzer - Mass Spectrometer (MOMA-MS) is an instrument in the MOMA instrument suite for the European Space Agency (ESA) ExoMars 2020 Rover. The rover is Planetary Protection Mission Category IVb, the first IVb mission since the Viking missions in the 1970s. Within the sample path of the MOMA instrument suite, the hardware surfaces of the must be sanitized to a level of less than 0.03 spore/m sq. To meet this requirement, the MS sample path was subjected to Dry Heat Microbial Reduction (DHMR) to decrease the number of viable spores by 4 orders of magnitude from a measured 88 spores/m sq to 0.009 spores/m sq. Before DHMR, the hardware is handled using standard cleanroom practices. After DHMR, planetary protection filters protect the sample path for most of integration, but when sample path exposure is required, aseptic operations are instituted and exposure times are kept to an absolute minimum. The surface area of exposure is also taken into account to determine safe exposure times. Before work begins, the ISO class 5 aseptic workspace is cleaned and tested for surface and airborne bioburden, and all tools that will contact or be used near sample path surfaces are sterilized. During the exposure activity, sterile garments are worn, sterile gloves are changed as often as necessary, and the environment is monitored with active and passive fallout for bioburden and real time airborne particle counts. Sterile tools are handled by a two person team so that the operator touches only the tool and not the exterior surfaces of the sterilization pouch, and a sterile operating field is established as a safe place to organize tools or parts during the aseptic operations. In cases where aseptic operations are not feasible, localized DHMR is used after exposure. Any breach in the planetary protection cleanliness can necessitate repeating instrument level DHMR, which not only has significant cost and schedule implications, it also become a risk to hardware that is not rated for repeated long exposures to high temperatures.

Spacecraft Design↗

Transduction-like gene transfer in the methanogen Methanococcus voltae

Strain PS of Methanococcus voltae (a methanogenic, anaerobic archaebacterium) was shown to generate spontaneously 4.4-kbp chromosomal DNA fragments that are fully protected from DNase and that, upon contact with a cell, transform it genetically. This activity, here called VTA (voltae transfer agent), affects all markers tested: three different auxotrophies (histidine, purine, and cobalamin) and resistance to BES (2-bromoethanesulfonate, an inhibitor of methanogenesis). VTA was most effectively prepared by culture filtration. This process disrupted a fraction of the M. voltae cells (which have only an S-layer covering their cytoplasmic membrane). VTA was rapidly inactivated upon storage. VTA particles were present in cultures at concentrations of approximately two per cell. Gene transfer activity varied from a minimum of 2 x 10(-5) (BES resistance) to a maximum of 10(-3) (histidine independence) per donor cell. Very little VTA was found free in culture supernatants. The phenomenon is functionally similar to generalized transduction, but there is no evidence, for the time being, of intrinsically viral (i.e., containing a complete viral genome) particles. Consideration of VTA DNA size makes the existence of such viral particles unlikely. If they exist, they must be relatively few in number;perhaps they differ from VTA particles in size and other properties and thus escaped detection. Digestion of VTA DNA with the AluI restriction enzyme suggests that it is a random sample of the bacterial DNA, except for a 0.9-kbp sequence which is amplified relative to the rest of the bacterial chromosome. A VTA-sized DNA fraction was demonstrated in a few other isolates of M. voltae.

Methanococcus/genetics/growth & development/metabo↗

HST WFC3 Observations of Uranus' 2014 Storm Clouds and Comparison with VLT/SINFONI and IRTF/Spex Observations

In November 2014 Uranus was observed with the Wide Field Camera 3 (WFC3) instrument of the Hubble Space Telescope as part of the Hubble 2020: Outer Planet Atmospheres Legacy program, OPAL. OPAL annually maps Jupiter, Uranus and Neptune (and will also map Saturn from 2018) in several visible near- infrared wavelength filters. The Uranus 2014 OPAL observations were made on the 89th November at a time when a huge cloud complex, first observed by de Pater et al. (2015) and subsequently tracked by professional and amateur astronomers (Sayanagi et al., 2016), was present at 30-40deg N. We imaged the entire visible atmosphere, including the storm system, in seven filters spanning 467924 nm, capturing variations in the coloration of Uranus clouds and also vertical distribution due to wavelength dependent changes in Rayleigh scattering and methane absorption optical depth. Here we analyse these new HST observations with the NEMESIS radiative-transfer and retrieval code in multiple-scattering mode to determine the vertical cloud structure in and around the storm cloud system. The same storm system was also observed in the H-band (1.4-1.8 micrometers) with the SINFONI Integral Field Unit Spectrometer on the Very Large Telescope (VLT) on 31st October and 11th November, reported by Irwin et al. (2016, 10.1016j.icarus.2015.09.010). To constrain better the cloud particle sizes and scattering properties over a wide wavelength range we also conducted a limb-darkening analysis of the background cloud structure in the 30-40deg N latitude band by simultaneously fitting: a) these HSTOPAL observations at a range of zenith angles; b) the VLTSINFONI observations at a range of zenith angles; and c) IRTFSpeX observations of this latitude band made in 2009 at a single zenith angle of 23deg, spanning the wavelength range 0.8-1.8 micrometers (Irwin et al., 2015, 10.1016j.icarus.2014.12.020). We find that the HST observations, and the combined HSTVLTIRTF observations at all locations are well modelled with a three-component cloud comprised of: 1) a vertically thin, but optically thick deep tropospheric cloud at a pressure of approximately 2 bars; 2) a methane-ice cloud based at the methane-condensation level of approximately 1.23 bar, with variable vertical extent; and 3) a vertically extended tropospheric haze, also based at the methane-condensation level of 1.23 bar. We find that modelling both haze and tropospheric cloud with particles having an effective radius of approximately 0.1 micron provides a good fit the observations, although for the tropospheric cloud, particles with an effective radius as large as 1.0 micron provide a similarly good fit. We find that the particles in both the tropospheric cloud and haze are more scattering at short wave- lengths, giving them a blue color, but are more absorbing at longer wavelengths, especially for the tropospheric haze. We find that the spectra of the storm clouds are well modelled by localized thickening and vertical extension of the methane-ice cloud. For the particles in the storm clouds, which we assume to be composed of methane ice particles, we find that their mean radii must lie somewhere in the range 0. 1 1. 0 m. We find that the high clouds have low integrated opacity, and that streamers reminiscent of convective thunderstorm anvils are confined to levels deeper than 1 bar. These results argue against vigorous moist convective origins for the cloud features.

atmospheres↗

Noncontact measurement of high temperature using optical fiber sensors

The primary goal of this research program was the investigation and application of noncontact temperature measurement techniques using optical techniques and optical fiber methods. In particular, a pyrometer utilizing an infrared optical light pipe and a multiwavelength filtering approach was designed, revised, and tested. This work was motivated by the need to measure the temperatures of small metallic pellets (approximately 3 mm diameter) in free fall at the Microgravity Materials Processing Drop Tube at NASA Marshall Space Flight Center. In addition, research under this program investigated the adaptation of holography technology to optical fiber sensors, and also examined the use of rare-earth dopants in optical fibers for use in measuring temperature. The pyrometer development effort involved both theoretical analysis and experimental tests. For the analysis, a mathematical model based on radiative transfer principles was derived. Key parameter values representative of the drop tube system, such as particle size, tube diameter and length, and particle temperature, were used to determine an estimate of the radiant flux that will be incident on the face of an optical fiber or light pipe used to collect radiation from the incandescent falling particle. An extension of this work examined the advantage of inclining or tilting the collecting fiber to increase the time that the falling particle remains in the fiber field-of-view. Those results indicate that increases in total power collected of about 15 percent may be realized by tilting the fiber. In order to determine the suitability of alternative light pipes and optical fibers, and experimental set-up for measuring the transmittance and insertion loss of infrared fibers considered for use in the pyrometer was assembled. A zirconium fluoride optical fiber and several bundles of hollow core fiber of varying diameters were tested. A prototype two-color pyrometer was assembled and tested at Virginia Tech, and then tested on the Drop Tube at Marshall Space Flight Center. Radiation from 5 mm diameter niobium drops falling in the Drop Tube was successfully detected, and recorded for later analysis. Subsequent analysis indicated that the imaging of light output from the light pipe onto the detector active areas was not identical for both detectors.

Claus, R. O.↗

Partial Wave Analysis of Coupled Photonic Structures

The very high quality factors sustained by microcavity optical resonators are relevant to applications in wavelength filtering, routing, switching, modulation, and multiplexing/demultiplexing. Increases in the density of photonic elements require that attention be paid to how electromagnetic (EM) coupling modifies their optical properties. This is especially true when cavity resonances are involved, in which case, their characteristics may be fundamentally altered. Understanding the optical properties of microcavities that are near or in contact with photonic elements---such as other microcavities, nanostructures, couplers, and substrates---can be expected to advance our understanding of the roles that these structures may play in VLSI photonics, biosensors and similar device technologies. Wc present results from recent theoretical studies of the effects of inter- and intracavity coupling on optical resonances in compound spherical particles. Concentrically stratified spheres and bispheres constituted from homogeneous and stratified spheres are subjects of this investigation. A new formulation is introduced for the absorption of light in an arbitrary layer of a multilayered sphere, which is based on multiple reflections of the spherical partial waves of the Lorenz-Mie solution for scattering by a sphere. Absorption efficiencies, which can be used to profile cavity resonances and to infer fluorescence yields or the onset of nonlinear optical processes in the microcavities, are presented. Splitting of resonances in these multisphere systems is paid particular attention, and consequences for photonic device development and possible performance enhancements through carefully designed architectures that exploit EM coupling are considered.

Fuller, Kirk A.↗

Properties of the clouds of Venus, as inferred from airborne observations of its near-infrared reflectivity spectrum

The shape and absolute value of Venus' reflectivity spectrum is measured in the 1.2- to 4.0 micrometer spectral region with a circular variable filter wheel spectrometer having a spectral resolution of 1.5%. Comparing these spectra with synthetic spectra generated with a multiple-scattering computer code, a number of properties of the Venus clouds are inferred. Evidence is obtained indicating that the clouds are made of a water solution of sulfuric acid in their top unit optical depth, and that the clouds are made of this material down to an optical depth of at least 25. In addition, the acid concentration is 84 plus or minus 2% H2SO4 by weight in the top unit optical depth, the total optical depth of the clouds is 37.5 plus or minus 12.5, and the cross-sectional weighted mean particle radius lies between 0.5 and 1.4 micrometers in the top unit optical depth of the clouds. It is found that the average volume mixing ratio of H2SO4 and H2O contained in the cloud material both equal approximately 2 x 10 to the -6. Employing vapor pressure arguments, the acid concentration is shown to equal 84 plus or minus 6% at the cloud bottom and the water vapor mixing ratio beneath the clouds lies between 6 x 10 to the -4 and 10 to the -2.

Pollack, J. B.↗

Aircraft sampling of the sulfate layer near the tropopause following the eruption of Mount St. Helens

Twenty-three filter sampling flights of the NASA Lewis F-106 aircraft, were conducted in the Great Lakes region between June 4 and Dec. 23, 1980, following the major eruption of Mount St. Helens on May 18. The IPC-1478 filters were exposed over an altitude range spanning the local tropopause. A filter sample exposed above the tropopause on June 5 indicated a sulfate level 50 times the baseline measurements, which is consistent with the trajectory predictions of the leading edge of the cloud on its second transit around the earth. Subsequent measurements over a period of 7 months revealed the existence of a layer of sulfate above the tropopause that decayed to a level of about 4 times previously measured background levels by the beginning of August. Concentration of nitrate above the tropopause exhibited considerable variability and showed some enhancement compared with previously measured concentration levels. On the basis of the null results of X ray fluorescence measurements, there is no evidence of ash particle concentrations of greater than 3.4 microns/cu m persisting in the layer above the tropopause following the second transit of the cloud.

Lezberg, E. A.↗

Aircraft sampling of the sulfate layer near the tropopause following the eruption of Mount St. Helens

Twenty filter sampling flights of the NASA Lewis F-106 aircraft were conducted in the Great Lakes region between June 4 and August 8, 1980, following the major eruption of Mount St. Helens, Washington on May 18. The IPC-1478 filters were exposed over an altitude range spanning the local tropopause. Quarter sections were analyzed for sulfate and nitrate by ion chromatography and selected samples were analyzed for chloride by selective ion electrode. Trace elements were searched by X-ray fluorescence analysis. A filter sample taken above the tropopause on June 5 indicated a sulfate level of 50 times the baseline measurements. Subsequent measurements over a period of 2 months showed an initial dropoff and formation of a persistent layer of sulfate above the tropopause with a concentration of 10 to 18 times previously measured background-levels. Concentrations of nitrate above the tropopause exhibited considerable variability and some enhancement compared with previously measured concentration levels. It is suggested that the source of the nitrate may also be volcanic as evidenced by its temporal relationship to the sulfate concentration changes. Based on the null results of X-ray fluorescence measurements, there is no evidence of ash particle concentrations greater than 3.4 microns g/cubic m persisting in the layer above the tropopause after the second transit of the cloud.

Lezberg, E. A.↗

Postperihelion interference filter photometry of the 'annual' Comet P/Encke

Interference filter photometry was taken of Comet Encke on June 14, 1974 (1.07 AU heliocentric distance, postperihelion) at the CTIO (Cerro Tololo Interamerican Observatory) 150-cm reflector. Production rates were calculated as 4.1 x 10 to the 23nd power mol/sec for CN, 5.3 x 10 to 23nd power mol/sec for C3, and 4.3 x 10 to the 24th power mol/sec for C2. These are about three times smaller than at comparable heliocentric distance preperihelion, assuming a value of 100 for the ratio H2O/(C2 + C3 + CN). An upper limit was placed on the production of nonvolatiles at about one-third that of volatiles in mass by assuming a bulk density of 1 g/cu cm, a particle geometric albedo of 0.1, and a phase function of 0.2.

Newburn, R. L., Jr.↗

Observations of enhanced sub-iron (Sc-Cr) to Iron abundance ratios in the low energy galactic cosmic rays in Spacelab-3 and their implications

The Anuradha cosmic ray experiment in Spacelab-3, flown in the orbit at 350 km with an inclination of 57 deg for about six days, was used to measure the low energy galactic cosmic ray (GCR) heavy ions using a specially designed CR-39 detector module incorporating the arrival time information of the particles. The abundances of sub-iron (Sc-Cr) and iron particles in the low energy interval of 30-300 MeV/N were determined from the measurements made in four different depths of the Cr-39 detector module of 150 layers. From these studies we obtained sub-iron (Sc-Cr) to iron abundance ratios of 0.8 to 1.2 in 30-300 MeV/N energy range. It is found that these ratios are enhanced by a factor of two as compared to interplanetary ratios of about 0.5. It is shown that the enhancement of the ratio inside the earth's magnetosphere is probably due to the degree of ionization of low energy Sc to Cr and Fe ions in the galactic cosmic rays and to the rigidity filtering effects of the geomagnetic field. Further studies are needed to understand fully the phenomena and their implications.

Biswas, S.↗

Improved Cloud Condensation Nucleus Spectrometer

An improved thermal-gradient cloud condensation nucleus spectrometer (CCNS) has been designed to provide several enhancements over prior thermal- gradient counters, including fast response and high-sensitivity detection covering a wide range of supersaturations. CCNSs are used in laboratory research on the relationships among aerosols, supersaturation of air, and the formation of clouds. The operational characteristics of prior counters are such that it takes long times to determine aerosol critical supersaturations. Hence, there is a need for a CCNS capable of rapid scanning through a wide range of supersaturations. The present improved CCNS satisfies this need. The improved thermal-gradient CCNS (see Figure 1) incorporates the following notable features: a) The main chamber is bounded on the top and bottom by parallel thick copper plates, which are joined by a thermally conductive vertical wall on one side and a thermally nonconductive wall on the opposite side. b) To establish a temperature gradient needed to establish a supersaturation gradient, water at two different regulated temperatures is pumped through tubes along the edges of the copper plates at the thermally-nonconductive-wall side. Figure 2 presents an example of temperature and supersaturation gradients for one combination of regulated temperatures at the thermally-nonconductive-wall edges of the copper plates. c) To enable measurement of the temperature gradient, ten thermocouples are cemented to the external surfaces of the copper plates (five on the top plate and five on the bottom plate), spaced at equal intervals along the width axis of the main chamber near the outlet end. d) Pieces of filter paper or cotton felt are cemented onto the interior surfaces of the copper plates and, prior to each experimental run, are saturated with water to establish a supersaturation field inside the main chamber. e) A flow of monodisperse aerosol and a dilution flow of humid air are introduced into the main chamber at the inlet end. The inlet assembly is designed to offer improved (relative to prior such assemblies) laminar-flow performance within the main chamber. Dry aerosols are subjected to activation and growth in the supersaturation field. f) After aerosol activation, at the outlet end of the main chamber, a polished stainless-steel probe is used to sample droplets into a laser particle counter. The probe features an improved design for efficient sampling. The counter has six channels with size bins in the range of 0.5- to 5.0-micron diameter. g) To enable efficient sampling, the probe is scanned along the width axis of the main chamber (thereby effecting scanning along the temperature gradient and thereby, further, effecting scanning along the supersaturation gradient) by means of a computer-controlled translation stage.

Leu, Ming-Taun↗

Stacked-disc structure for fluid filter or valve silencer

A stacked-disc structure is comprised of a stack of annular discs (13) scalloped along the outer edge to provide lobes (13a) and etched on one side to provide lands (13a). A web (13d) is retained in the lobes to strengthen the discs so that they will not collapse due to high fluid pressure. The stack of discs is retained by a housing (10) having a fluted interior wall to retain the ends of the lobes. End plates (11 and 12) secure the stack of discs with a spacer (14) at one end having lands (14a) on lobes which match the lobes of the stacked discs to allow fluid to flow into, or out of, the spaces between the lobes of the stacked discs. The spaces between the lands on the etched discs provide passages for fluid flow into or out of the hollow core of the stack. The height of the lands (i.e., depth of the etch) determines the size of the smallest particle that will be permitted to flow through. The stacked-disc structure may be connected to the inlet of a valve, or be incorporated into the valve housing on the inlet side of the valve seat to assure substantially constant fluid velocity, and thereby reduce valve noise when the valve is operated.

Hagler, Jr., Ray↗

X-Ray Spectroscopy of Optically Bright Planets using the Chandra Observatory

Since its launch in July 1999, Chandra's Advanced CCD Imaging Spectrometer (ACIS) has observed several planets (Venus, Mars, Jupiter and Saturn) and 6 comets. At 0.5 arc-second spatial resolution, ACIS detects individual x-ray photons with good quantum efficiency (25% at 0.6 KeV) and energy resolution (20% FWHM at 0.6 KeV). However, the ACIS CCDs are also sensitive to optical and near-infrared light, which is absorbed by optical blocking filters (OBFs) that eliminate optical contamination from all but the brightest extended sources, e.g., planets. .Jupiter at opposition subseconds approx.45 arc-seconds (90 CCD pixels.) Since Chandra is incapable of tracking a moving target, the planet takes 10 - 20 kiloseconds to move across the most sensitive ACIS CCD, after which the observatory must be re-pointed. Meanwhile, the OBF covering that CCD adds an opt,ical signal equivalent to approx.110 eV to each pixel that lies within thc outline of the Jovian disk. This has three consequences: (1) the observatory must be pointed away from Jupiter while CCD bias maps are constructed; (2) most x-rays from within the optical image will be misidentified as charged-particle background and ignored; and (3) those x-rays that are reported will bc assigned anomalously high energies. The same also applies to thc other planets, but is less serious since they are either dimmer at optical wavelengths, or they show less apparent motion across the sky, permitting reduced CCD exposure times: the optical contamination from Saturn acids approx.15 eV per pixel, and from Mars and Venus approx.31 eV. After analyzing a series of short .Jupiter observations in December 2000, ACIS parameters were optimized for the February 2003 opposition. CCD bias maps were constructed while Chandra pointed away from Jupiter, and the subsequent observations employed on-board software to ignore any pixel that contained less charge than that expected from optical leakage. In addition, ACIS was commanded to report 5 x 5 arrays of pixel values surrounding each x-ray event, and the outlying values were employed during ground processing to correct for the optical contamination.

Ford, P. G.↗

A Combined Very Large Telescope and Gemini Study of the Atmosphere of the Directly Imaged Planet, Beta Pictoris b

We analyze new/archival VLT/NaCo and Gemini/NICI high-contrast imaging of the young, self-luminous planet Beta Pictoris b in seven near-to-mid IR photometric filters, using advanced image processing methods to achieve high signal-to-noise, high precision measurements. While Beta Pic b's near-IR colors mimic those of a standard, cloudy early-to-mid L dwarf, it is overluminous in the mid-infrared compared to the field L/T dwarf sequence. Few substellar/planet-mass objects-i.e., κ And b and 1RXJ 1609B-match Beta Pic b's JHKsL photometry and its 3.1 micron and 5 micron photometry are particularly difficult to reproduce. Atmosphere models adopting cloud prescriptions and large (approx. 60 micron)dust grains fail to reproduce the Beta Pic b spectrum. However, models incorporating thick clouds similar to those found forHR8799 bcde, but also with small (a fewmicrons) modal particle sizes, yield fits consistent with the data within the uncertainties. Assuming solar abundance models, thick clouds, and small dust particles (a = 4 micron), we derive atmosphere parameters of log(g) = 3.8 +/- 0.2 and Teff = 1575-1650 K, an inferred mass of 7+4 −3 MJ, and a luminosity of log(L/L) approx. −3.80 +/- 0.02. The best-estimated planet radius, is approx. equal to 1.65 +/- 0.06 RJ, is near the upper end of allowable planet radii for hot-start models given the host star's age and likely reflects challenges constructing accurate atmospheric models. Alternatively, these radii are comfortably consistent with hot-start model predictions if Beta Pic b is younger than is approx. equal to 7 Myr, consistent with a late formation well after its host star's birth approx. 12+8 −4 Myr ago.

overluminous↗

Nanophase, Low-Ni Metal Grains in Fine-grained Rims in the Murchison CM2 Chondrite: Insights into the Survival of Metal Grains During Aqueous Alteration

Aqueous alteration has played a significant role in the geological evolution of almost all the chondrite groups and attests to the importance of water during the earliest history of the solar system. Among the chondrites that show evidence of aqueous alteration the CM chondrites, in particular, have received considerable attention, because of their primitive composition and the fact that they preserve a record of incomplete hydration. Petrologic studies of this group of meteorites have helped provide important insights into aqueous alteration processes and the nature of the alteration products. However, due to the complex history of these chondrites, important details of the alteration remain enigmatic. Among the major problems to be resolved are the location and timing of aqueous alteration as well as the relationship between alteration and brecciation. Although many authors favor aqueous alteration within a parent body environment, there is also evidence that some of the components of CM chondrites may have experienced aqueous alteration prior to accretion. One of the key lines of evidence for alteration in a pre-accretionary environment is the presence of unaltered metal grains associated with hydrated phases. Low-Ni metal (kamacite) is typically one of the first phases in CM chondrites that alters in the presence of water. However, in some CM chondrites, such as Yamato 791198, micron-sized metal grains are present within the hydrated fine-grained rim material around chondrules. In addition, nanometer-sized grains that have been interpreted as being unaltered metal particles have been reported in the relatively heavily altered CM chondrite, ALH 81002. In most cases, these occurrences have been interpreted as being the result of mixing of anhydrous and hydrous materials prior to accretion. According to this hypothesis, the metal grains remain unaltered because little or no post-accretionary alteration took place. Whilst such a scenario is plausible, no alternative explanations such as the presence of submicron protective layers or a minor element chemistry that might inhibit oxidation have been investigated in detail. During a study of the distribution of carbonaceous material in fine-grained rims on chondrules in Murchison, previously unidentified, nanometer-sized metal grains were observed. These grains were characterized in detail using high resolution TEM and energy filtered TEM (EFTEM) and provide important insights into how metal grains in CM chondrites may survive aqueous alteration.

Brearley, Adrian J.↗

In-Situ Measurements of Aerosol Optical Properties using New Cavity Ring-Down and Photoacoustics Instruments and Comparison with more Traditional Techniques

Carbonaceous species (BC and OC) are responsible for most of the absorption associated with aerosol particles. The amount of radiant energy an aerosol absorbs has profound effects on climate and air quality. It is ironic that aerosol absorption coefficient is one of the most difficult aerosol properties to measure. A new cavity ring-down (CRD) instrument, called Cadenza (NASA-ARC), measures the aerosol extinction coefficient for 675 nm and 1550 nm light, and simultaneously measures the scattering coefficient at 675 nm. Absorption coefficient is obtained from the difference of measured extinction and scattering within the instrument. Aerosol absorption coefficient is also measured by a photoacoustic (PA) instrument (DRI) that was operated on an aircraft for the first time during the DOE Aerosol Intensive Operating Period (IOP). This paper will report on measurements made with this new instrument and other in-situ instruments during two field recent field studies. The first field study was an airborne cam;oaign, the DOE Aerosol Intensive Operating Period flown in May, 2003 over northern Oklahoma. One of the main purposes of the IOP was to assess our ability to measure extinction and absorption coefficient in situ. This paper compares measurements of these aerosol optical properties made by the CRD, PA, nephelometer, and Particle Soot Absorption Photometer (PSAP) aboard the CIRPAS Twin-Otter. During the IOP, several significant aerosol layers were sampled aloft. These layers are identified in the remote (AATS-14) as well as in situ measurements. Extinction profiles measured by Cadenza are compared to those derived from the Ames Airborne Tracking Sunphotometer (AATS-14, NASA-ARC). The regional radiative impact of these layers is assessed by using the measured aerosol optical properties in a radiative transfer model. The second study was conducted in the Caldecott Tunnel, a heavily-used tunnel located north of San Francisco, Ca. The aerosol sampled in this study was characterized by fresh automobile and diesel exhaust. Measurements from Cadenza and from an aethalometer are presented. The aethalometer is a filter-based photometer and the infrared channel is calibrated to produce a measure of BC mass loading.

Strawa, A. W.↗

Sensitivity of Marine Warm Cloud Retrieval Statistics to Algorithm Choices: Examples from MODIS Collection 6

The optical and microphysical structure of warm boundary layer marine clouds is of fundamental importance for understanding a variety of cloud radiation and precipitation processes. With the advent of MODIS (Moderate Resolution Imaging Spectroradiometer) on the NASA EOS Terra and Aqua platforms, simultaneous global/daily 1km retrievals of cloud optical thickness and effective particle size are provided, as well as the derived water path. In addition, the cloud product (MOD06/MYD06 for MODIS Terra and Aqua, respectively) provides separate effective radii results using the l.6, 2.1, and 3.7 ~m spectral channels. Cloud retrieval statistics are highly sensitive to how a pixel identified as being "notclear" by a cloud mask (e.g., the MOD35/MYD35 product) is determined to be useful for an optical retrieval based on a 1-D cloud model. The Collection 5 MODIS retrieval algorithm removed pixels associated with cloud'edges as well as ocean pixels with partly cloudy elements in the 250m MODIS cloud mask - part of the so-called Clear Sky Restoral (CSR) algorithm. Collection 6 attempts retrievals for those two pixel populations, but allows a user to isolate or filter out the populations via CSR pixel-level Quality Assessment (QA) assignments. In this paper, using the preliminary Collection 6 MOD06 product, we present global and regional statistical results of marine warm cloud retrieval sensitivities to the cloud edge and 250m partly cloudy pixel populations. As expected, retrievals for these pixels are generally consistent with a breakdown of the ID cloud model. While optical thickness for these suspect pixel populations may have some utility for radiative studies, the retrievals should be used with extreme caution for process and microphysical studies.

Platnick, Steven↗

Development of a Submillimeter/Far-Infrared Radiometer for Cirrus Measurements

We introduce a low-cost, lightweight and compact polarisation-sensitive radiometer for the measurement of Cirrus clouds in the submillimeter and far-infrared region (10 150 cm-1). It is widely recognised that enhanced global measurements of cirrus properties are essential to the development of General Circulation and Climate Prediction Models since cirrus clouds have a strong effect on the Earth's Global Radiation Budget. The purpose of this project is to design and build a novel instrument suitable for aircraft deployment in order to measure Ice Water Path (IWP) along with cirrus particle size and shape. This airborne instrument, which is currently under development in Cardiff, will serve as a prototype for a future satellite-based radiometer. The radiometer will capitalize on the ongoing measurements of the NASA-led, Fourier Transform interferometer-based, FIRSC (Far-Infrared Sensor for Cirrus) instrument for which Cardiff has been closely associated. Data from FIRSC campaigns is being used to select optimum radiometer channels that exhibit good sensitivity to specific cirrus. This new multichannel radiometer will, however, have some key advantages over similar spectroscopic instruments, for example, portability, increased optical efficiency, a multi-angle field of view and a reduced integration period leading to an improved spatial resolution. The radiometer will benefit from the application of state-of-the-art submm/FIR polarizer and solid filter technology currently being developed in Cardiff. The instrument will require a detector array that is robust enough to withstand aircraft/space deployment.

Hayton, Darren↗