Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Infrared Computer-Generated Holograms: Design and Application for the WFIRST Grism Using Wavelength-Tuning Interferometry

Interferometers using computer-generated holograms (CGHs) have become the industry standard to accurately measure aspheric optics. The CGH is a diffractive optical element that can create a phase or amplitude distribution and can be manufactured with low uncertainty using modern lithographic techniques. However, these CGHs have conventionally been used with visible light and piezo-shifting interferometers. Testing the performance of transmissive optics in the infrared requires infrared CGHs and an infrared interferometer. Such an instrument is used in this investigation, which introduces its phase shift via wavelength-tuning. A procedure on how to design and manufacture infrared CGHs and how these were successfully used to model and measure the Wide-Field Infrared Survey Telescope grism elements is provided. Additionally, the paper provides a parametric model, simulation results, and calculations of the errors and measurements that come about when interferometers introduce a phase variation via wavelength-tuning interferometry to measure precision aspheres.

Communication↗

First Searches for Optical Counterparts to Gravitational-Wave Candidate Events

During the Laser Interferometer Gravitational-wave Observatory and Virgo joint science runs in 2009-2010, gravitational wave (GW) data from three interferometer detectors were analyzed within minutes to select GW candidate events and infer their apparent sky positions. Target coordinates were transmitted to several telescopes for follow-up observations aimed at the detection of an associated optical transient. Images were obtained for eight such GW candidates. We present the methods used to analyze the image data as well as the transient search results. No optical transient was identified with a convincing association with any of these candidates, and none of the GW triggers showed strong evidence for being astrophysical in nature. We compare the sensitivities of these observations to several model light curves from possible sources of interest, and discuss prospects for future joint GW-optical observations of this type.

gravitational waves↗

Stitching Techniques Advance Optics Manufacturing

Because NASA depends on the fabrication and testing of large, high-quality aspheric (nonspherical) optics for applications like the James Webb Space Telescope, it sought an improved method for measuring large aspheres. Through Small Business Innovation Research (SBIR) awards from Goddard Space Flight Center, QED Technologies, of Rochester, New York, upgraded and enhanced its stitching technology for aspheres. QED developed the SSI-A, which earned the company an R&D 100 award, and also developed a breakthrough machine tool called the aspheric stitching interferometer. The equipment is applied to advanced optics in telescopes, microscopes, cameras, medical scopes, binoculars, and photolithography."

Source record↗

Dual differential interferometer for measurements of broadband surface acoustic waves

A simple duel interferometer which uses two pairs of orthogonally polarized optical beams to measure both the amplitude and direction of propagation of broadband ultrasonic surface waves is described. Each pair of focused laser probe beams is used in a separate wideband differential interferometer to independently detect the component of surface wave motion along one direction on the surface. By combining the two output signals corresponding to both components, the two dimensional surface profile and its variation as a function of time is determined.

Turner, T. M.↗

System identification and structural control on the JPL Phase B testbed

The primary objective of NASA's CSI program at JPL is to develop and demonstrate the CSI technology required to achieve high precision structural stability on large complex optical class spacecraft. The focus mission for this work is an orbiting interferometer telescope. Toward the realization of such a mission, a series of evolutionary testbed structures are being constructed. The JPL's CSI Phase B testbed is the second structure constructed in this series which is designed to study the pathlength control problem of the optical train of a stellar interferometer telescope mounted on a large flexible structure. A detailed description of this testbed can be found. This paper describes our efforts in the first phase of active structural control experiments of Phase B testbed using the active control approach where a single piezoelectric active member is used as an actuation device and the measurements include both colocated and noncolocated sensors. Our goal for this experiment is to demonstrate the feasibility of active structural control using both colocated and noncolocated measurements by means of successive control design and loop closing. More specifically, the colocated control loop was designed and closed first to provide good damping improvement over the frequency range of interest. The noncolocated controller was then designed with respect to a partially controlled structure to further improve the performance. Based on our approach, experimental closed-loop results have demonstrated significant performance improvement with excellent stability margins.

Chu, Cheng-Chih↗

Optical figure testing of prototype mirrors for JPL's Precision Segmented Reflector (PSR) program

JPL's PSR program is developing enabling technologies for large space telescopes employing segmented optics, and in particular, lightweight, thermally stable mirrors for telescopes operating at sub-mm wavelengths. JPL's vacuum cryointerferometric optical test facility includes a computer-controlled phase shifting interferometer operating at 10.59 microns and laser metrology for measurement of piston and absolute radius of curvature. The optical metrology has been integrated with a large vacuum chamber including a liquid nitrogen shroud capable of radiatively cooling 1.5 meter aperture mirrors down to 150 K. The facility is now being used to characterize prototype mirrors in both their room-temperature 'as-replicated' condition, and under orbital temperature conditions. The performance and limitations of the optical metrology hardware and software components are noted. Representative test results on prototype one meter-class composite mirrors being developed for PSR and related ground-based programs are also presented.

Hochberg, Eric B.↗

Review of image correlation systems - Hybrid and optical

The operating principles, design, and development histories of three image correlation systems, the Portable Correlator Unit (PCU), the Miniature Correlator Unit (MCU), and the Coherence Interferometer (CI) are reviewed. The PCU and MCU are compact versions of the classical Vander Lught filter optical correlator, essentially parallel optical processors by light valve; the CI is a white-light correlator which functions entirely by interfering light waves, with electronic detection only at the final output, and thus represents a parallel optical processor by rotational-shear interferometer. Details of the design and construction are discussed and illustrated with drawings and photographs. Also considered are applications of the MCU to NASA tasks such as rendezvous and docking on the Mars Rover and Sample Return mission, autonomous robotic exploration of planetary surfaces, and compression and pattern-recognition of remote-sensing data.

Breckinridge, James B.↗

An optical heterodyne densitometer

Researchers are developing an optical heterodyne densitometer with the potential to measure optical density over an unprecedented dynamic range with high accuracy and sensitivity. This device uses a Mach-Zender interferometer configuration with heterodyne detection to make direct comparisons between optical and RF attenuators. Researchers expect to attain measurements of filter transmittance down to 10 to the minus 12th power with better than 1 percent uncertainty. In addition, they intend to extend the technique to the problem of measuring low levels of light scattering from reflective and transmissive optics.

Migdall, A. L.↗

Spectrally Resolved Synthetic Aperture Imaging Interferometer: Final Report of NASA Innovative Advanced Concepts - Phase 1 Study

The Spectrally Resolved Synthetic-Aperture Imaging Interferometer (SRSAII) is a system proposed to provide high-resolution and high-sensitivity measurements of astronomical objects. SRSAII uses long baseline interferometric methods to achieve the resolution and low-noise, high time-precision detection to achieve the sensitivity. The primary goal of the SRSAII study was to lay out a framework for using new optical physics technologies to directly resolve, both spatially and spectrally, the disk of an exoplanet. In addition to the ambitious goal of directly resolving an exoplanet, the SRSAII team also sought to identify science opportunities achievable with intermediate system configurations which may offer resolution significantly higher than the current state of the art, but insufficient for direct resolution of an exoplanetary disk. An operational SRSAII system can function with essentially arbitrarily large baselines, achieving correspondingly high angular resolution. The primary limitation occurs in the system sensitivity, which became the major technical focus for study. In this report, we compare the predicted performance (sensitivity in SNR (Signal-to-Noise Ratio) along with angular resolution) of three interferometric techniques: direct detection (also known as homodyne interferometry), multi-channel intensity interferometry (using the Hanbury Brown and Twiss effect), and multi-channel heterodyne interferometry (using an optical frequency comb as a local oscillator). Additionally, quantum-assisted interferometry is also explored as a prospective enhancement of established methods. This report presents a survey of the technologies that enable the SRSAII techniques - optical frequency combs, single photon detectors, and photonic integrated circuits. These technologies are the basis of methods critical to SRSAII's success: precision timing, length and frequency metrology, sensitive photodetection, fine-scale wavelength filtering, and dense multi-channel operation. Lastly, we give some notional performance metrics and propose some possible experimental observations.

High Resolultion↗

Multi-Segment Radius Measurement Using an Absolute Distance Meter Through a Null Assembly

This system was one of the test methods considered for measuring the radius of curvature of one or more of the 18 segmented mirrors that form the 6.5 m diameter primary mirror (PM) of the James Webb Space Telescope (JWST). The assembled telescope will be tested at cryogenic temperatures in a 17-m diameter by 27-m high vacuum chamber at the Johnson Space Center. This system uses a Leica Absolute Distance Meter (ADM), at a wavelength of 780 nm, combined with beam-steering and beam-shaping optics to make a differential distance measurement between a ring mirror on the reflective null assembly and individual PM segments. The ADM is located inside the same Pressure-Tight Enclosure (PTE) that houses the test interferometer. The PTE maintains the ADM and interferometer at ambient temperature and pressure so that they are not directly exposed to the telescope s harsh cryogenic and vacuum environment. This system takes advantage of the existing achromatic objective and reflective null assembly used by the test interferometer to direct four ADM beamlets to four PM segments through an optical path that is coincident with the interferometer beam. A mask, positioned on a linear slide, contains an array of 1.25 mm diameter circular subapertures that map to each of the 18 PM segments as well as six positions around the ring mirror. A down-collimated 4 mm ADM beam simultaneously covers 4 adjacent PM segment beamlets and one ring mirror beamlet. The radius, or spacing, of all 18 segments can be measured with the addition of two orthogonally-oriented scanning pentaprisms used to steer the ADM beam to any one of six different sub-aperture configurations at the plane of the ring mirror. The interferometer beam, at a wavelength of 687 nm, and the ADM beamlets, at a wavelength of 780 nm, pass through the objective and null so that the rays are normally incident on the parabolic PM surface. After reflecting off the PM, both the ADM and interferometer beams return to their respective instruments on nearly the same path. A fifth beamlet, acting as a differential reference, reflects off a ring mirror attached to the objective and null and returns to the ADM. The spacings between the ring mirror, objective, and null are known through manufacturing tolerances as well as through an in situ null wavefront alignment of the interferometer test beam with a reflective hologram located near the caustic of the null. Since total path length between the ring mirror and PM segments is highly deterministic, any ADM-measured departures from the predicted path length can be attributed to either spacing error or radius error in the PM. It is estimated that the path length measurement between the ring mirror and a PM segment is accurate to better than 100 m. The unique features of this invention include the differential distance measuring capability and its integration into an existing cryogenic and vacuum compatible interferometric optical test.

Merle, Cormic↗

Diffusivity Measured as a Function of Concentration

Optical diagnostic techniques have become an integral part of many measurements in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used to measure optical wave fronts for lens testing and combustion and fluid flow diagnostics. One such instrument is the point diffraction interferometer (PDI), which is considered to be robust because it has a common-path design. However, the PDI is difficult to align and has limited measurement range for liquid phase applications. Interferometry and schlieren techniques have been widely used for many years for gas flow visualization.

Rashidnia, Nasser↗

Development of a Broadband Achromatic Twyman-Green Interferometer

A modified Twyman-Green interferometer is in use that makes possible wavefront testing of optical filters at any wavelength from 200 to 1100 nanometers. The use of mirrors for collimation and pupil imaging makes the intrument achromatic, and therefore the focus is fixed over the entire bandwidth.

interferometer↗

Optical device for measuring a surface characteristic of an object by multi-color interferometry

An interferometer having a light beam source that produces a plurality of separate and distinct wavelengths of light. Optic fibers are used to transport the wavelengths of light toward an object surface and to allow light reflected from the object to pass through a polarizer to improve the polarization ratio of the reflected light to determine a characteristic of the object surface.

Meyer, William V.↗

Deep optically thin cirrus clouds in the polar regions. I - Infrared extinction characteristics

The spectral data obtained by the infrared interferometer Spectrometer (IRIS) flown on Nimbus 4 satellite in 1970 indicated the existence of optically thin ice clouds in the upper troposphere that probably extended into lower stratosphere, in the polar regions, during winter and early spring. The spectral features of these clouds differ somewhat from that of the optically thin cirrus clouds in the tropics. From theoretical simulation of the infrared spectra in the 8-25 micron region, it is inferred that these polar clouds have a vertical stratification in particle size, with larger particles (about 12 microns) in the bottom of the cloud and smaller ones (less than 1 micron) aloft. Radiative transfer calculations also suggest that the equivalent ice-water content of these polar clouds is of the order of 1 mg/sq cm.

Prabhakara, C.↗

Processing of Signals from Fiber Bragg Gratings Using Unbalanced Interferometers

Fiber Bragg gratings (FBG) have become preferred sensory structures in fiber optic sensing system. High sensitivity, embedability, and multiplexing capabilities make FBGs superior to other sensor configurations. The main feature of FBGs is that they respond in the wavelength domain with the wavelength of the returned signal as the indicator of the measured parameter. The wavelength is then converted to optical intensity by a photodetector to detect corresponding changes in intensity. This wavelength-to-intensity conversion is a crucial part in any FBG-based sensing system. Among the various types of wavelength-to-intensity converters, unbalanced interferometers are especially attractive because of their small weight and volume, lack of moving parts, easy integration, and good stability. In this paper we investigate the applicability of unbalanced interferometers to analyze signals reflected from Bragg gratings. Analytical and experimental data are presented.

Adamovsky, Grigory↗

NASA Tech Briefs, February 2010

Topics covered include: Insulation-Testing Cryostat With Lifting Mechanism; Optical Testing of Retroreflectors for Cryogenic Applications; Measuring Cyclic Error in Laser Heterodyne Interferometers; Self-Referencing Hartmann Test for Large-Aperture Telescopes; Measuring a Fiber-Optic Delay Line Using a Mode-Locked Laser; Reconfigurable Hardware for Compressing Hyperspectral Image Data; Spatio-Temporal Equalizer for a Receiving-Antenna Feed Array; High-Speed Ring Bus; Nanoionics-Based Switches for Radio-Frequency Applications; Lunar Dust-Tolerant Electrical Connector; Compact, Reliable EEPROM Controller; Quad-Chip Double-Balanced Frequency Tripler; Ka-Band Waveguide Two-Way Hybrid Combiner for MMIC Amplifiers; Radiation-Hardened Solid-State Drive; Use of Nanofibers to Strengthen Hydrogels of Silica, Other Oxides, and Aerogels; Two Concepts for Deployable Trusses; Concentric Nested Toroidal Inflatable Structures; Investigating Dynamics of Eccentricity in Turbomachines; Improved Low-Temperature Performance of Li-Ion Cells Using New Electrolytes; Integrity Monitoring of Mercury Discharge Lamps; White-Light Phase-Conjugate Mirrors as Distortion Correctors; Biasable, Balanced, Fundamental Submillimeter Monolithic Membrane Mixer; ICER-3D Hyperspectral Image Compression Software; and Context Modeler for Wavelet Compression of Spectral Hyperspectral Images.

Source record↗

Optical testing cryogenic thermal vacuum facility

The construction of a turnkey cryogenic vacuum test facility was recently completed. The facility will be used to measure and record the surface profile of large diameter and 540 kg optics under simulated space conditions. The vacuum test chamber is a vertical stainless steel cylinder with a 3.5 diameter and a 7 m tangent length. The chamber was designed to maximize optical testing quality by minimizing the vibrations between the laser interferometer and the test specimen. This was accomplished by designing the chamber for a high natural frequency and vibration isolating the chamber. An optical test specimen is mounted on a movable presentation stage. During thermal vacuum testing, the specimen may be positioned to + or - 0.00025 cm accuracy with a fine adjustment mechanism. The chamber is evacuated by a close coupled Roots-type blower and rotary vane pump package and two cryopumps. The chamber is equipped with an optically dense gaseous nitrogen cooled thermal shroud. The thermal shroud is used to cool or warm the optical test specimen at a controlled rate. A control system is provided to automatically evacuate the chamber and cooldown the test specimen to the selected control temperature.

Dohogne, Patrick W.↗

MEMS AO for Planet Finding

This slide presentation reviews a method for planet finding using microelectromechanical systems (MEMS) Adaptive Optics (AO). The use of a deformable mirror (DM) is described as a part of the instrument that was designed with a nulling interferometer. The strategy that is used is described in detail.

calibration interferometer↗