Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “monitoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Evaluation of a Smoke Opacity Sensor for Improving Residential Wood Heater Combustion

Residential wood heating lacks real-time particulate matter (PM) monitoring technologies capable of measuring emissions directly from flue gases. This study evaluates the performance of the Octoring, an opacity-based smoke sensor developed to monitor wood heater emissions and provide feedback for improved combustion. The device was tested on catalytic and non-catalytic cordwood heaters and a pellet heater during startup, high-burn, and low-burn phases. Performance was assessed against reference particle instruments and gravimetric measurements using concordance, correlation, and agreement analyses. Results show that temperature-dependent drift is the primary limitation affecting sensor accuracy, with systematic drift observed across ambient and combustion conditions. Agreement with reference instruments ranged from poor to good depending on operating conditions, with the strongest performance observed during pellet heater high-burn operation. These findings establish a performance baseline for opacity-based sensing technologies and identify key areas for further development before practical deployment in residential wood combustion monitoring systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Pushing the Dark-Matter Limit: The LUX-Zeplin (LZ) Experiment (Final Report)

This report highlights the accomplishments of the dark-matter group of the University of Rochester during the project period. During the grant period, all of our responsibilities for LUX were completed. Several papers describing the results of LUX analyses carried out by the Rochester group were published. The success of the Rochester trigger electronics, developed for LUX, resulted in it being selected to provide the digital platform for LZ. The PI is leading an excellent team of engineers, scientists, and students to provide the signal processing electronics, the control and monitoring system for the LZ detector, and the online computing infrastructure to process the LZ data and transfer them to the US Data Center at NERSC. During the grant period most of the R&D and prototyping of the LZ electronics was completed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural Health Monitoring of Epoxy Bond between Dissimilar Materials

Structures composed of adhesively bonded materials face many challenges when subjected to thermal loading, as adherend material(s) behave differently and can induce stresses in the glue bond. Current methods to test bond strength are limited to destructive tests, which increase costs to produce adhesively bonded structures. Strain gages are proposed to monitor the expansion profile of adhesive bonds as structures undergo thermal loading. Because resulting signals are DC in nature, no spectral quantities can be observed. Principle component analysis (PCA) is proposed to differentiate between damaged and undamaged structures. Training data are taken for various damage states and the minimum Mahalanobis distance is calculated to categorize testing data into damage state. The results indicate the potential for a strain-gage based monitoring system with PCA based decision-making, with further research necessary prior to implementation of the system.

36 MATERIALS SCIENCE↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monthly Sewer Monitoring Report for LLNL Livermore Site, April 2020

Lawrence Livermore National Laboratory (LLNL) collects effluent samples from its sewer outfall at the B196 Sewer Monitoring Station (SMS). Effluent flow-proportional composite samples are collected at the SMS on a daily (midnight-to-midnight), weekly (Thursday through Wednesday), and “monthly” (composited from daily) basis; effluent grab samples are also collected each month at that same location. Certified contract laboratories analyzes these compliance samples, and results (Tables 1–3) are used to establish LLNL compliance with the 2019–2020 Wastewater Discharge Permit (Permit 1250) granted by the City of Livermore Water Resources Division (WRD). Supplemental analyses for biochemical oxygen demand (BOD) and total suspended solids (TSS) are performed onsite and reported (Table 4) for the calculation and assessment of sewer service charges. Quarterly, effluent is sampled for metals (24-hour composite) and cyanide (grab sample) concentrations (mg/L). The results are presented in Table 5. In addition to the sampling noted above, the SMS continuously monitors LLNL sewage effluent in real-time for flow rate, pH, metals, and radioactivity. Standard measurement methods are used to monitor flow and pH to determine permit compliance. Unique nonstandard analytical methods monitor for the presence of metals and radioactivity using x-ray fluorescence (XRF) and gamma spectroscopy, respectively. If an anomalous condition is detected by the monitoring system, an alarm activates LLNL’s Sewer Diversion Facility (SDF) and Livermore Water Reclamation Plant (LWRP) operators are notified that a potential release has occurred.

54 ENVIRONMENTAL SCIENCES↗

Screening IMS Seismic Detections using Dynamic Correlation Processor: Progress report for 2020

LLNL completed the FY20 workplan entailing application of the Dynamic Correlation Processor (DCP) to International Monitoring System (IMS) primary seismic data in 2019 and 2020. The effective analysis period was curtailed to January 1 through November 12, 2019 due to a data compression change that rendered later data unusable. Fixing the data compression error is a priority for our data source, and we plan to extend the period of data analysis when the fix is implemented. We found that the percentage overlap between detections generated by the International Data Centre (IDC) DFX software and detections generated by DCP varied widely by station. Overlap is 30-40% at some stations, suggesting that a large percentage of DFX detections could be screened (removed) from the detection-event association algorithm. However, detection overlap was much lower, a few percent, at many stations and the percentage overlap was low at stations known to have many mines and other local sources of seismicity. Unexpectedly low detection overlap at many stations prompted us to examine results for the ARCES station in detail. There is considerable mine activity near ARCES, but our initial FY20 analysis found only ~2% DCP/DFX detection overlap. Differences in the pre-processing (e.g. beam recipes) used by DCP and DFX appear to be the cause of low detection overlap at ARCES. DCP uses wideband filters to improve detector robustness and the IDC uses narrow-band pre-filtering to improve sensitivity. After reprocessing ARCES using the IDC beam recipe, DCP/DFX overlap increased to ~74%. This result shows that we must reprocess the IMS network using the IDC station-specific beam recipes if we are to effectively screen DFX detections and improve automatic event building performance at the IDC.

58 GEOSCIENCES↗

Microseismic Event Denoising: Removal of Borehole Waves

The vertical borehole array at Farnsworth Unit, TX is used to monitor microseismic activity in the subsurface around the Carbon Capture and Sequestration (CCS) reservoir. The array consists of 16 3-component seismometers spaced vertically in a single borehole. Tube or borehole waves traveling up or down the borehole can corrupt signals of interest, such as microseismic events. A denoising convolutional neural network (DCNN) was trained to remove borehole waves from seismic waveforms of microseismic events for the purpose of reducing unwanted signal detections and better characterizing events of interest. This R&D leverages the work of Sandia colleague Rigo Tibi, who used a DCNN developed by Greg Beroza at Stanford University to improve the signal-to-noise ratio (SNR) of teleseismic events detected by the International Monitoring System.

58 GEOSCIENCES↗

Technical Issues in the Comprehensive Nuclear Test Ban Treaty (CTBT) Ratification Debate: A 20 Year Retrospective

Two decades after the U.S. Senate declined in 1999 to give its consent to ratification of the Comprehensive Nuclear Test Ban Treaty (CTBT), the treaty remains in legal and political limbo. Legally, the treaty cannot enter into force without U.S. ratification. However, the Senate’s rejection does not strip the treaty of its force as an element of customary international law or alter the will of other signatories to see it enter into force. Politically, the debate over the virtues and flaws of the treaty remains as strong as ever, with some CTBT advocates pushing energetically for U.S. re-review while some opponents seek ways to “un-sign” the treaty. Meanwhile, despite the Senate’s rejection of the treaty, the United States acts in a manner consistent with its main obligations by maintaining a moratorium on explosive nuclear testing and providing financial support (as well as technical expertise) to the CTBT Organization (CTBTO)—in particular the CTBTO’s International Monitoring System (IMS). The CTBT may well remain in such limbo for a long time to come, unless some catalytic event comes along to re-shape national perceptions and priorities, one way or the other. The treaty’s future, whatever it might be, will be determined in part by how much perspectives might have changed in light of interim developments. Our purpose is to shed light on some of those developments and to assess their relevance. The 1999 ratification debate addressed a large number of issues. Rejection was driven by various policy and technical judgments. The purpose of this paper is to re-examine those technical judgments in light of what has been learned over the following two decades. On some technical matters, there was explicit recognition of extant uncertainties, as well as a conviction and hope that time would dispel them. To be doubly clear, our purpose is not to recommend a way forward on CTBT ratification. The policy judgments of 1999 and 2020 are beyond the scope of this paper. This technical re-examination proceeds as follows. It begins with a short background section to introduce the key technical matters in discussion in the U.S. ratification process. Then it moves systematically through each of those topics with a review of relevant background information, a discussion of key points in debate, an analysis of subsequent experience, and a current assessment. The historical analysis draws on many sources including the primary documents of the Congressional debate, the official article-by-article interpretation by the Department of State, and the statements of key players in the process. We also relied on key technical reports and publications by subject matter experts that have addressed in more detail many of the issues in our focus. These sources include the 2002 and 2012 reports of the National Academy of Sciences as well as publications by senior technical staff of Lawrence Livermore National Laboratory (LLNL) who were actively involved in the ratification debate, including then-Laboratory Director Bruce Tarter. We also conducted several interviews with government officials from the 1990s, past laboratory directors, and other members of the scientific community. But, except where individuals are specifically cited by name, the judgments offered here are our own and should not be attributed to any other individual or to LLNL as such.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Installation of Lysimeters Near Engineered Trench 3

Three new lysimeter stations were installed on the north rim of Engineered Trench 3 (Figure ES-1)at the E-Area Low Level Waste Facility (ELLWF). These stations were designated as ET3-VL-3, ET3-VL-4, and ET3-VL-5. The stations were installed in a line with the two existing stations (ET3-VL-1 and ET3-VL-2) and spaced approximately 100 ft apart. Two lysimeters were installed at each station at the depths shown in Table ES-1. Lysimeter placement was based on borehole lithology and was comparable to the existing lysimeter stations. The deepest lysimeter at each of the three new lysimeter stations was designated as the action-level lysimeter.Following installation, the lysimeters were purged and placed under vacuum for sampling. Sampling occurred in December 2020 with each lysimeter producing 1000 ml of water for tritium analysis. All lysimeters were below the administrative limit for ET3 (43.7 pCi/ml) with all but ET3-VL-5 (222) at background levels. ET3-VL-5 (222) had a tritium concentration of 27.5 pCi/ml.With the addition of the new lysimeters at ET3, the vadose zone monitoring system is now comprised of 309 active lysimeters at 102 lysimeter stations. There are 93 action-level lysimeters at 102 stations

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Monitoring Radiochemical Processing Streams for the 238 Pu Supply Program with Process Pulse II

Oak Ridge National Laboratory (ORNL) is developing advanced spectroscopic and real-time monitoring capabilities to improve the timeliness of analytical measurements and process decisions for the 238Pu Supply Program. Reducing the time, resources, and costs associated with each production campaign is critical because overlapping campaigns will be required to meet the production goals of the National Aeronautics and Space Administration. Real-time, in situ analytical measurements in the heavily shielded hot cells at the Radiochemical Engineering Development Center (REDC) will allow for rapid process information feedback and operational benefits that help the 238Pu supply program scale-up production efforts. Noteworthy steps were taken during Campaign 5 to establish the ability to monitor processing streams in real time with spectrophotometry and a commercially available online monitoring software called The Unscrambler X Process Pulse II (PP) multivariate statistical process monitoring system by Camo Analytics (version 5.60). PP automates univariate-type calculations within the software itself and executes multivariate models built using The Unscrambler X (version 10.4 or newer). The Unscrambler is a commercially available data analysis software made by the same company. PP is composed of easy-to-use-tools for all personnel, including data scientists and technicians. The software can be used to plot analyte concentration profiles, spectral data, and other process variables in real time. All process data are represented in a single view with interactive charts useful for viewing how a process evolves over time.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the PhaseNet Model Applied to the IMS Seismic Network

Producing a complete and accurate set of signal detections is essential for automatically building and characterizing seismic events of interest for nuclear explosion monitoring. Signal detection algorithms have been an area of research for decades, but still produce large quantities of false detections and misidentify real signals that must be detected to produce a complete global catalog of events of interest. Deep learning methods have shown promising capabilities in effectively characterizing seismic signals for complex tasks such as identifying phase arrival times. We use the PhaseNet model, a UNet-based Neural Network, trained on local distance data from northern California to predict seismic arrivals on data from the International Monitoring System (IMS) global network. We use an analyst-curated bulletin generated from this data set to compare the performance of PhaseNet to that of the Short-Term Average/Long-Term Average (STA/LTA) algorithm. We find that PhaseNet has the potential of outperforming traditional processing methods and recommend the training of a new model with the IMS data to achieve optimal performance.

58 GEOSCIENCES↗

Test Plan for Investigation of Hydrogen Generation in SNF Canisters

This report presents a test plan to investigate radiolytic hydrogen generation in spent nuclear fuel (SNF) canisters containing Zr-based cladding materials. The initial primary contributor to the generation of radiolytic hydrogen is estimated to be the residual physisorbed water on the ZrO 2 film, post-dry out. Over the longer term the primary hydrogen source is associated with the aluminum hydroxides and water vapor. The proposed testing to be conducted in FY22 would consist of lab-scale testing on non-radioactive surrogates of oxidized ZIRLO tubing and unalloyed zirconium using a miniature steel canister (“mini-canister") designed to allow intermittent, in-situ sampling of the canister gas during irradiation. The mini-canister approach for irradiation with in-situ monitoring system was used in a recent and on-going study [McNamara and Verst, 2020a & 2020b; Verst et al., 2021] to measure radiolytic hydrogen generation from aluminum SNF cladding surrogate materials. This proposed testing will form part of the overall materials performance evaluation of the commercial SNF-in-canister system and is part of the technical bases for their continued safe dry storage

08 HYDROGEN↗

ESH-ASI-2021-004 DOE Annual Letter (redacted markings)

File LLNL2020_DOE_GI_ANNUAL.txt was submitted electronically to the REIRS file submission. The file contains positive and zero doses for 3,308 Lawrence Livermore National Security (LLNS) and subcontractor employees. There were 96 individuals with a collective Total Effective Dose (TED) of 6,886 mrem. The 2020 data follow the DOE Radiation Exposure Monitoring Systems (REMS) format per instructions in the REMS Reporting Guide.

61 RADIATION PROTECTION AND DOSIMETRY↗

In-Sodium Testing of a Prototype Thermoacoustic Power Sensor for Sodium-Cooled Fast Reactors

The ultimate goal of this project is to develop and demonstrate a thermoacoustic power sensor (TAPS) for Sodium-Cooled Fast Reactors (SFRs), with potential application also envisioned to other nuclear technologies such as Lead-Cooled Fast Reactors (LFRs), Molten Salt Reactors (MSRs), in addition to Light Water Reactors (LWRs). The project was led by Westinghouse Electric Company, LLC (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and the University of Pittsburgh. A TAPS is a passive (self-powered), non-invasive (wireless) sensor envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. The sensor generates pressure waves (i.e., sound waves) with a frequency and amplitude dependent upon nuclear operating conditions (coolant temperature or power changes). The acoustic waves are able to travel through the core and associated structures, and reach to the sensor network placed outside and/or inside of the reactor vessel. These sensors require a very small amount of power which, during loss of power events, can be provided, for example, by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. Westinghouse and the University of Pittsburgh designed and fabricated TAPS prototypes for Argonne National Laboratory (ANL) to carry out in-sodium testing to evaluate the effects of sodium on the TAPS and the performance of the TAPS technique in sodium. Argonne received a TAPS prototype from Westinghouse, and the prototype was modified such that it can be installed into a test vessel and function in sodium at elevated temperature without potentially leaking. A water mockup test apparatus was constructed to validate proper working of the prototype. An instrumentation and control (I&C) system, running on the National Instruments (NI) LabView platform, was developed to: 1) operate both the water mockup test and the in-sodium test facility; and 2) process and analyze the received acoustic signals from an array of accelerometers and the Argonne sodium-submersible high-temperature acoustic sensor. The prototype was successfully tested in a water bath at different temperatures. Water mockup tests demonstrated that the TAPS prototype is working properly and its resonance frequency changes linearly with the coolant (water) temperature. A TAPS test apparatus was constructed and integrated with the upgraded Under-Sodium Viewing (USV) sodium test facility. The integrated USV-TAPS sodium test facility has been operational. The TAPS prototype and a high-temperature sodium-submersible acoustic sensor (SSAS) developed by Argonne were both installed inside the TAPS test vessel. Being operated within argon cover gas under ambient conditions, the TAPS prototype demonstrated that it was functioning properly with a resonance frequency at 1407.2 Hz, which was successfully detected by the accelerometers mounted on the external wall of the vessel and the high-temperature SSAS installed inside the vessel. After successfully transferring sodium into the vessel, in-sodium tests of the prototype were conducted. Tests of the TAPS prototype demonstrated that the resonance frequency of the TAPS changes linearly with respect to the temperature difference between the interior of the TAPS and bulk sodium. The early tests showed that the TAPS prototype could not establish a continuous and consistent resonance in sodium. The resonance diminished before the prototype reached its operating temperature. A signal postprocessor was added to the DAQ module latterly to isolate interferences, enhance signal conditioning, improve peak detection, and generate resonance frequency versus temperature plots. After testing in molten sodium and immersion at higher temperature for several weeks, the TAPS prototype was able to establish a continuous resonance. Performance evaluation of the TAPS prototype was then conducted in sodium. The tests included the investigation of 1) the effects of the temperature difference between the TAPS and bulk sodium, 2) the effects of sodium flowrate; and 3) the performance of the different sensor-receiver systems positioned inside or outside the vessel. Results of a test demonstrated that, with limited sodium circulation, a continuous and consistent resonance of the TAPS prototype was established occasionally. The tests also demonstrated that, because of the nature of detection principles and mounting methods, the high temperature SSAS is more affected by acoustic noise, while accelerometers are more affected by vibrations, in the test environment. It is unknown why the TAPS prototype only occasionally established a continuous and consistent resonance when the TAPS temperature reached its operating temperature in molten sodium, and why it ultimately failed to resonate at all. A failure modes assessment was conducted and a few potential causes of failure were identified. Different post in-sodium tests were conducted to obtain additional information potentially relevant to the cause of the failure. Nondestructive evaluation techniques are suggested to examine the internal integrity as well as the gas mixture of the prototype. If they prove inconclusive, the prototype should be cut open to conduct a thorough inspection of its internal integrity and determine the state of the gas mixture.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Fusion to Enhance Quality Control and Analysis with Instruments at the Marine and Coastal Research Laboratory

Deploying environmental monitoring instruments in the marine environment can be challenging, facing challenges around device survivability, biofouling and corrosion, and consistent data collection. This project explores the use of data fusion – the process of integrating multiple data sources to produce more consistent, accurate, and useful information – to build a consistent long-term monitoring system at the Marine and Coastal Research Laboratory (MCRL) in Sequim, Washington. Unused instruments that had been acquired from past projects were inventoried and deployments planned on the MCRL pier and floating dock. A total of 8 instruments were deployed including a tide gauge, hydrophone, acoustic Doppler current profiler (ADCP), photosynthetically active radiation (PAR) sensors, meteorological station, and three water quality sensors. Deployments were planned to be well-protected around the pier structure and a maintenance schedule was created for cleaning and recalibration. An automated data pipeline was created to aggregate data on edge computers that push data to Amazon Web Services (AWS) cloud storage every 15 minutes, performing automated quality control and data transformations using the Time Series Data Analytical Toolkit (TSDAT). Continued efforts are underway to maintain this system into the future, take a data-driven approach to maintenance scheduling, improve the reliability of the system, and share the data with a variety of end-users.

54 ENVIRONMENTAL SCIENCES↗

Applying Waveform Correlation and Waveform Template Metadata to Aftershocks in the Middle East to Reduce Analyst Workload

Organizations that monitor for underground nuclear explosive tests are interested in techniques that automatically characterize recurring events such as aftershocks to reduce the human analyst effort required to produce high-quality event bulletins. Waveform correlation is a technique that is effective in finding similar waveforms from repeating seismic events. In this study, we apply waveform correlation in combination with template event metadata to two aftershock sequences in the Middle East to seek corroborating detections from multiple stations in the International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization. We use waveform templates from stations that are within regional distance of aftershock sequences to detect subsequent events, then use template event metadata to discover what stations are likely to record corroborating arrival waveforms for recurring aftershock events at the same location, and develop additional waveform templates to seek corroborating detections. We evaluate the results with the goal of determining whether applying the method to aftershock events will improve the choice of waveform correlation detections that lead to bulletin-worthy events and reduction of analyst effort.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Applying Waveform Correlation and Waveform Template Metadata to Mining Blasts to Reduce Analyst Workload

Organizations that monitor for underground nuclear explosive tests are interested in techniques that automatically characterize mining blasts to reduce the human analyst effort required to produce high - quality event bulletins. Waveform correlation is effective in finding similar waveforms from repeating seismic events, including mining blasts. In this study we use waveform template event metadata to seek corroborating detections from multiple stations in the International Monitoring System of the Preparatory Commission for the Comprehensive Nuclear-Test-Ban Treaty Organization. We build upon events detected in a prior waveform correlation study of mining blasts in two geographic regions, Wyoming and Scandinavia. Using a set of expert analyst-reviewed waveform correlation events that were declared to be true positive detections, we explore criteria for choosing the waveform correlation detections that are most likely to lead to bulletin-worthy events and reduction of analyst effort.

47 OTHER INSTRUMENTATION↗