Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “micro”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Terahertz-Regime, Micro-VEDs: Evaluation of Micromachined TWT Conceptual Designs

Summary form only given. The Terahertz (THz) region of the electromagnetic spectrum (approx.300-3000 GHz) has enormous potential for high-data-rate communications, spectroscopy, astronomy, space research, medicine, biology, surveillance, remote sensing, industrial process control, etc. The most critical roadblock to full exploitation of the THz band is lack of coherent radiation sources that are powerful (0.01-10.0 W continuous wave), efficient (>1 %), frequency agile (instantaneously tunable over 1% bandwidths or more), reliable, and relatively inexpensive. Micro-machined Vacuum Electron Devices (micro-VEDs) represent a promising solution. We describe prospects for miniature, THz-regime TWTs fabricated using micromachining techniques. Several approx.600 GHz conceptual designs are compared. Their expected performance has been analyzed using SD, 2.51), and 3D TWT codes. A folded waveguide (FWG) TWT forward-wave amplifier design is presented based on a Northrop Grumman (NGC) optimized design procedure. This conceptual device is compared to the simulated performance of a novel, micro-VED helix TWT. Conceptual FWG TWT backward-wave amplifiers and oscillators are also discussed. A scaled (100 GHz) FWG TWT operating at a relatively low voltage (-12 kV) is under development at NGC. Also, actual-size micromachining experiments are planned to evaluate the feasibility of arrays of micro-VED TWTs. Progress and results of these efforts are described. This work was supported, in part by AFOSR, ONR, and NSF.

Booske, John H.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Spacecraft Micro-Vibration: A Survey of Problems, Experiences, Potential Solutions, and Some Lessons Learned

Predicting, managing, controlling, and testing spacecraft microvibrations due to on-board internal disturbance sources is a formidable multi-disciplinary systems engineering challenge, especially for those observatories hosting extremely sensitive optical sensor payloads with stringent requirements on allowable line-of-sight jitter. In this paper some specific spacecraft micro-vibration engineering challenges will be introduced and described. Technical background context is provided with the inclusion of several illustrative examples of NASA and European Space Agency missions (both past and present) where dynamic interactions have to be addressed and which have demanding payload instrument line-of-sight jitter requirements. A general modeling, analysis, simulation, and test approach to address and solve the overall problem of spacecraft micro-vibrations is outlined. Recommended rules of thumb are presented to provide guidance for analysts on where to initiate and how to approach a new spacecraft micro-vibration design problem. A set of experience-based spacecraft micro-vibration lessons learned are also presented in the hope they can be leveraged on new system development projects to help overcome unfamiliarity with previously identified microvibration technical pitfalls and challenges.

Dennehy, Cornelius↗

Second-Generation Micro-Spec: A Compact Spectrometer for Far-Infrared and Submillimeter Space Missions

Micro-Spec is a direct-detection spectrometer which integrates all the components of a diffraction-grating spectrometer onto a ≈ 10-sq.cm chip through the use of superconducting microstrip transmission lines on a single- crystal silicon substrate. The second generation of Micro-Spec is being designed to operate with a spectral re- solution of at least 512 in the far-infrared and submillimeter (420–540 GHz, 714–555 μm) wavelength range, a band of interest for NASA's experiment for cryogenic large-aperture intensity mapping called EXCLAIM. EXCLAIM will be a balloon-borne telescope that is being designed to map the emission of redshifted carbon monoxide and singly-ionized carbon lines over a redshift range 0 < z < 3.5 and it will be the first demonstration of the Micro-Spec technology in a space-like environment. This work reviews the status of the Micro-Spec design for the EXCLAIM telescope, with emphasis on the spectrometer's two-dimensional diffractive region, through which light of different wavelengths is focused on kinetic inductance detectors along the instrument focal plane. An optimization process is used to generate a geometrical configuration of the diffractive region that satisfies l range and performance. An initial optical design optimized for n terms of geometric layout, spectral purity and efficiency.

Cataldo, Giuseppe↗

Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration

The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.

J. S. Adams↗

Predictive Modeling of Carbon Ablators Using Micro and Macro-Scale Modeling

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

Application of Micro-thrusters for Space Observatory Precision Attitude Control

This paper describes the results of a NASA investigation into the benefits of micro-thrusters compared to reaction wheels on future observatory-class missions with tight pointing stability requirements. Pointing repeatability and stability (i.e., jitter) requirements are key for space telescope missions of the future. For example, managing jitter is essential to being able to “image” planets orbiting distant stars. Jitter requirements for missions in this class are difficult to meet with current reaction wheel-based architectures. The reaction wheels are typically the largest pointing disturbance on the spacecraft. Disturbances from reaction wheels can be mitigated, typically by mechanically isolating the wheels, which imposes system complexity and cost. Thrusters capable of thrust forces in the micronewton (μN) range (referred to as micro-thrusters or micronewton thrusters) have been developed to support the Laser Interferometer Space Antenna (LISA) mission, which requires drag-free control to place a test mass in near-perfect free-fall Beyond the drag-free control application, micro-thrusters could be used as a substitute for reaction wheels or as a supplement to wheels for fine pointing control. Used in this fashion, micro-thrusters have potential for reducing the cost and technical risks of achieving demanding pointing stability performance on observatory-class missions.

Chiang, Richard Y.↗

A Preliminary Study on the Feasibility of Large Language Models for Detecting Micro-Behaviors Among Team Members in Space Missions

Large-language models (LLMs) have been recently used for spoken language understanding (SLU) to infer meaning and semantics from speech in tasks such as speaker intent and sentiment classification. Due to being trained on large amounts of data, and their ability to understand context and relationships between words, LLMs are competent, enabling them to generalize across tasks without requiring many task-specific training samples. This research examines the feasibility of few-shot learning in LLMs for detecting subtle, brief, and possibly unconscious interactions between team members, called ``micro-behaviors," and provides insights into the appropriate design of LLMs for this task. Our data came from 5 teams participating in a 45-day mission at the US National Aeronautics and Space Administration’s (NASA) Human Exploration Research Analog (HERA). More specifically we used data collected from team interaction battery (TIB) tasks teams performed five times in-mission which comprise an average 1.5 hours of conversation data per day. Micro-behaviors were coded according to an adapted version of Smith & Griffins (2022) theoretical framework in terms of Violation (i.e., presence of valenced behavior, uplifting/positive or discouraging/negative), Intensity (i.e., force of behavior in terms of how uplifting or discouraging is the behavior), and Intent (i.e., motive of the behavior in terms of whether it was deliberate or unintentional). We explore the ability of LLMs to detect the presence and intensity of micro-behaviors. We examine employing and fine-tuning readily available LLMs (i.e., RoBERTa, DistilBERT), as well as prompting state-of-the-art sequence classification models (i.e., Llama-2, Llama-3). In a total of 13,058 conversational turns (17.8% uplifting, 3.3% discouraging, 75.76% neutral, 3.14% nulls), we compute the macro F1-score of the 3-way micro-behavior classification task (i.e., classifying among uplifting, discouraging, and neutral; 33% chance). Results indicate that the RoBERTa model achieves a F1-score of 36.2% (uplift: 43.3% precision (P), 15.1% recall (R); discourage: 20% P, 0.5% R). These results significantly improve when we augment the data via paraphrasing in the RoBERTa model, reaching a 41.2% macro F1-score (uplift: 37.7% P, 86.3% R; discourage: 3.5% P, 1.8% R). Finally, the Llama-2 model with 3-shot prompting yields 38% macro F1-score (uplift: 28.7% P, 20% R; discourage: 7.2% P, 18% R), which is slightly better compared to the RoBERTa model without data augmentation, highlighting the effectiveness of sequence classification models in detecting minority classes with a small sample size. Findings indicate that LLMs hold potential to detect subtle behaviors in conversations, which could be valuable in assessing team behavior in space exploration missions. Future studies will evaluate the performance of different LLM prompting strategies or fine-tuning methods.

Ankush Raut↗

XRD micro-XANES EMPA and SIMS investigation on phlogopite single crystals from Mt. Vulture (Italy)

Selected phlogopite flakes from Mt. Vulture in southern Italy were studied using a combination of single-crystal techniques: electron microprobe analysis (EMPA), secondary ion mass spectrometry (SIMS), single-crystal X-ray diffraction (SCXRD), and micro-X-ray absorption near-edge spectroscopy (XANES). The latter technique was employed to analyze the structure of the Fe-K absorption edge over the region from 7080-8100 eV and to determine Fe{sup 3+}/{Sigma}Fe at a micrometer scale, albeit with large error bars due to known effects of orientation on pre-edge energy. The annite component, Fe/(Mg+Fe), of the samples studied ranged from 0.16 to 0.31, the Ti content from 0.11 to 0.27 atoms per formula unit (apfu) and the Ba content from 0.03 to 0.09 apfu. SIMS analysis showed H{sub 2}O (wt%) = 1.81-3.30, F (wt%) = 0.44-1.29, and Li{sub 2}O (wt%) = 0.001-0.027. The intra single-crystal chemical variability for major/minor elements (Mg, Fe, Al, Ba, Ti, and K) was found particularly significant for samples VUT191{_}11 and PG5{_}1, less significant for the other samples of the set. SIMS data relative to crystals VUT187{_}24, VUT191{_}10, VUT191{_}11, and VUT187{_}28 showed a noteworthy variation in the concentrations of some light elements (H, Li, and F) with coefficient of variation CV (as 1{sigma}%) up to {approx}18% for H{sub 2}O. The analyzed micas belong to the 1M polytype. Structure refinements using anisotropic displacement parameters were performed in space group C2/m and converged at 3.08 {<=} R {<=} 3.63, 3.32 {<=} R{sub w} {<=} 3.98%. Micro-XANES results yielded Fe{sup 3+}/{Sigma}Fe from 51-93%. Previous Moessbauer data from powdered samples suggested Fe{sup 3+}/{Sigma}Fe values ranging from 49-87%. However, the Fe{sup 3+} content determined by both techniques is sometimes remarkably different, in part because of the large errors ({+-}10-15%) presently associated with the micro-XANES technique and in part because the Fe{sup 3+} content of a single crystal may significantly depart from the average value obtained from routine Moessbauer analysis. The combination of EMPA, SIMS, and micro-XANES resulted in the characterization of the samples at a comparable spatial scale. By means of in-situ data and the results of crystallographic investigations, the occurrence of different relative amounts of M{sup 3+}-oxy [{sup VI}M{sup 2+} + (OH){sup -} {leftrightarrow} {sup VI}M{sup 3+} + O{sup 2-} + {1/2}H{sub 2}{up_arrow}], Ti-oxy substitutions [{sup VI}M{sup 2+} + 2(OH){sup -} {leftrightarrow} {sup VI}Ti{sup 4+} + 2O{sup 2-} + H{sub 2}{up_arrow}], and Ti-vacancy ({open_square}) substitution (2{sup VI}M{sup 2+} {leftrightarrow} {sup VI}Ti{sup 4+} + {sup VI}{open_square}) was ascertained for the studied samples.

58 GEOSCIENCES↗

Performance Bounds on Micro-Doppler Estimation and Adaptive Waveform Design Using OFDM Signals

We analyze the performance of a wideband orthogonal frequency division multiplexing (OFDM) signal in estimating the micro-Doppler frequency of a target having multiple rotating scatterers (e.g., rotor blades of a helicopter, propellers of a submarine). The presence of rotating scatterers introduces Doppler frequency modulation in the received signal by generating sidebands about the transmitted frequencies. This is called the micro-Doppler effects. The use of a frequency-diverse OFDM signal in this context enables us to independently analyze the micro-Doppler characteristics with respect to a set of orthogonal subcarrier frequencies. Therefore, to characterize the accuracy of micro-Doppler frequency estimation, we compute the Cram er-Rao Bound (CRB) on the angular-velocity estimate of the target while considering the scatterer responses as deterministic but unknown nuisance parameters. Additionally, to improve the accuracy of the estimation procedure, we formulate and solve an optimization problem by minimizing the CRB on the angular-velocity estimate with respect to the transmitting OFDM spectral coefficients. We present several numerical examples to demonstrate the CRB variations at different values of the signal-to-noise ratio (SNR) and the number of OFDM subcarriers. The CRB values not only decrease with the increase in the SNR values, but also reduce as we increase the number of subcarriers implying the significance of frequency-diverse OFDM waveforms. The improvement in estimation accuracy due to the adaptive waveform design is also numerically analyzed. Interestingly, we find that the relative decrease in the CRBs on the angular-velocity estimate is more pronounced for larger number of OFDM subcarriers.

Sen, Satyabrata↗

Micro-channel long molecule manipulation system

Laminar flow of a carrier liquid and polymeric molecules through micro-channels is used to straighten, align, separate, and/or sort the polymeric molecules. The polymeric molecules may be analyzed and/or manipulated in the carrier liquid or attached to a wall of the micro-channel for subsequent treatment and analysis. Micro-channels can be manufactured using an elastic molding material. One micro-channel embodiment provides fluid flow using a standard laboratory centrifuge.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Micro fluidic system for single molecule imaging

Laminar flow of a carrier liquid and polymeric molecules through micro-channels is used to straighten the polymeric molecules and attach the straightened molecules to a wall of the micro-channel for subsequent treatment and analysis. Micro-channels can be manufactured using an elastic molding material. One micro-channel embodiment provides fluid flow using a standard laboratory centrifuge.

59 BASIC BIOLOGICAL SCIENCES↗

Practical Challenges and Failure Modes During Fabrication of Haynes 230 Micro-Pin Solar Receivers for High Temperature Supercritical Carbon Dioxide Operation

Printed circuit heat exchangers (PCHX) fabricated from high nickel alloys have shown promise as primary heat exchangers, recuperators, and solar receivers for high temperature and pressure supercritical carbon dioxide power cycles. There are numerous challenges in fabricating these devices including forming channel features, joining via diffusion or transient liquid phase bonding, and brazing/welding of headers. Commercial entities are understandably hesitant to share propriety best practices, and both commercial and non-commercial entities working on these components tend not to publically share failures and mistakes. However, sharing of this information could prevent similar costly errors and further the understanding of the coupled manufacturing, materials and mechanics issues in creating these components. Thus, in this paper, we document the challenges, failures, and mitigation methods uncovered in fabrication of prototype micro-pin based solar thermal receivers constructed of Haynes 230 and fabricated through a combination of photochemical machining (PCM), wire electrical discharge machining (EDM), transient liquid phase (TLP) bonding, vacuum brazing, and gas tungsten arc welding (GTAW). The receiver is designed to absorb concentrated solar fluxes greater than 140 W cm-2, while heating supercritical carbon dioxide from 550 °C to 720 °C at a pressure of 20 MPa to 25 MPa. The prototype receiver consists of a thin (~ 450 µm), Haynes 230 coversheet bonded to a 15 cm × 15 cm Haynes 230 micro-pin plate. The pieces are joined using a TLP bonding process with a nickel-phosphorus interlayer. Prior to bonding, micro-pins with height ~150 µm and diameter 300 µm are fabricated using PCM in the plate, and through slot features are made using wire EDM. Finally, flow headers are joined to the microchannel plate through a combination of vacuum brazing and GTAW. During hydrostatic proof testing, the prototype device failed when the coversheet delaminated from the pin array at a pressure of 290 bar. A failure analysis including scanning electron microscopy (SEM) to view failure sites and energy-dispersive X-ray spectroscopy (EDS) to evaluate elemental analysis of the failed areas was conducted. The failure modes can be broadly categorized as (1) failures potentially relating to reliquification of the transient liquid phase bonds between the micro-pins plate and coversheet during post-processing, (2) failures related to manufacturing defects, and (3) failures attributed to design.

14 SOLAR ENERGY↗

Design and Operation of a Multi-Bed Catalytic Micro-Reactor for the Study of Co-Processing of Bio-Oils with VGO

An industry wide shift from fossil-based fuel to renewable fuel sources including biomass, municipal waste, and plastics will require new process monitoring methods to minimize transitional risks including off specification product formation and catalyst deactivation. This project aims to provide a machine learning based process monitoring tool composed of online, slipstream mass spectra for use in biomass refineries and co-processing in existing refineries allowing operators to monitor product qualities and adjust process conditions accordingly. In order to maximize the robustness of the tool, large volumes of data must be collected to fine tune model parameters which consists of both micro and pilot scale mass spectral data. Micro-scale data is collected with a multi-tube micro-reactor housing up to six catalysts in horizontal beds, coupled with a molecular beam mass spectrometer. A pyrolizer equipped with an auto-sampler streamlines the micro-scale data collection process. This type of pyrolizer/micro-reactor configuration does not exist on the market, and therefore had to be created for the purposes of this project. The design and commissioning of this reactor will be presented in detail. This reactor set-up is highly flexible and increases throughput of analysis. For catalyst testing, each bed can be individually selected simply by turning valves. For catalyst reduction and regeneration, simultaneous flow through all six beds is used. The reproducibility of the system was first assessed with whole biomass pyrolysis along with pyrolysis of calibration standards. Initial work on this system evaluated two FCC catalysts, equilibrium catalyst (E-cat), and a proprietary catalyst from Johnson Matthey specifically design for co-processing of bio-oil with vacuum gas oil (VGO). This work used model compounds and VGO which illuminated differences in products produced by the catalysts.

biomass↗

Micro Baselines for Operational Technology Environments

Critical infrastructure stakeholders need to baseline their networks to understand expected communications. Top-down approaches to baselining rely on observables that are generally available but lack properties upon which traditional statistical tools depend. We propose to construct micro-baselines: signatures within operational networks based on observables associated with specific events. Such observables are informed by precursor analysis reports of historical cyber attacks on operational environments developed by Cybersecurity for Operational Technology Environments (CyOTE). Baseline measurements depend upon context beyond the cyber domain. An energy plant's baseline running in the summer may statistically differ from a similar facility in a colder region. Domain knowledge must be integrated to apply general micro-baselining algorithms to a facility-specific context. Therefore, we propose to explore the feasibility of transferring micro baselining algorithms across different facilities. Facilities that implement the same processes in different geographic locations will be compared relative to observable measurements used in micro-baselining for comparable events. One evaluation approach would condition or augment dynamic observables measured within a facility network testbed with additional observables derived from geographic context or infrastructure dependencies such as those provided by the All-Hazards Analysis tool.

97 MATHEMATICS AND COMPUTING↗

System and method for additively manufacturing porous parts via salt micro-spheres

A system and method of additively manufacturing a part via salt micro-spheres. The method includes mixing salt micro-spheres with an additive manufacturing material to form an additive manufacturing material mixture. The additive manufacturing material mixture is deposited on a build platform layer by layer and cured so as to create a structure having pores formed by the salt micro-spheres. The salt micro-spheres may then be dissolved and flushed from the pores.

LaPlant, Steven Todd↗

Diagnostic system for profiling micro-beams

An apparatus for characterization of a micro beam comprising a micro modified Faraday cup assembly including a first layer of material, a second layer of material operatively connected to the first layer of material, a third layer of material operatively connected to the second layer of material, and a fourth layer of material operatively connected to the third layer of material. The first layer of material comprises an electrical conducting material and has at least one first layer radial slit extending through the first layer. An electrical ground is connected to the first layer. The second layer of material comprises an insulating material and has at least one second layer radial slit corresponding to the first layer radial slit in the first layer of material. The second layer radial slit extends through the second layer. The third layer of material comprises a conducting material and has at least one third layer radial slit corresponding to the second layer radial slit in the second layer of material. The third layer radial slit extends through the third layer. The fourth layer of material comprises an electrical conducting material but does not have slits. An electrical measuring device is connected to the fourth layer. The micro modified Faraday cup assembly is positioned to be swept by the micro beam.

47 OTHER INSTRUMENTATION↗

USE OF MICRO X-RAY ABSORPTION SPECTROSCOPY AND DIFFRACTION TO DELINEATE Cr(VI) SPECIATION IN COPR

The speciation of Cr(VI) in Cromite Ore Processing Residue was investigated by means of bulk XRD, and a combination of micro-XRF, -XAS and -XRD at the Advanced Light Source (ALS), Berkeley, CA, U.S.A.. Bulk XRD yielded one group of phases that contained explicitly Cr(VI) in their structure, Calcium Aluminum Chromium Oxide Hydrates, accounting for 60% of the total Cr(VI). Micro-analyses at ALS yielded complimentary information, confirming that hydrogarnets and hydrotalcites, two mineral groups that can host Cr(VI) in their structure by substitution, were indeed Cr(VI) sinks. Chromatite (CaCrO4) was also identified by micro-XRD, which was not possible with bulk methods due to its low content. The acquisition of micro-XRF elemental maps enabled not only the identification of Cr(VI)-binding phases, but also the understanding of their location within the matrix. This information is invaluable when designing Cr(VI) treatment, to optimize release and availability for reduction.

54 ENVIRONMENTAL SCIENCES↗