Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “low dose”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Transient Copper Exposure During Embryogenesis and Temperature Affect Developmental Rate, Survival, and Fin Regeneration in Japanese Medaka ( Oryzias latipes )

Combined environmental stressors that an organism experiences can have both immediate and lasting consequences. In this paper we exposed medaka (Oryzias latipes) embryos to sublethal copper sulfate (CuSO 4 ) (0, 10, and 100 ppb) in combination with different rearing temperatures (27, 30, and 33°C) to assess acute and latent effects on development, growth, and regenerative capacity. Embryos exposed to CuSO 4 and/or higher temperatures hatched significantly earlier. At 4 months post-exposure, fish exposed to low levels of CuSO 4 during development had higher survival, while fish exposed to both 100 ppb CuSO 4 and 33°C temperatures had significantly lower survival. Additionally, a sex-specific effect of embryonic CuSO 4 exposure was observed as female mass decreased with increasing copper dose. We also assessed caudal fin regenerative capabilities in both embryo-exposed fish at 4 months of age and adult medaka that were exposed to 0, 10, and 100 ppb CuSO 4 at room temperature during a 14- day trial. Whereas fin regeneration was unaffected by adult exposure to copper, fish transiently exposed during embryogenesis displayed an initial increase in fin growth rate and an increased incidence of abnormal fin morphology following regrowth. Collectively, these data suggest that developmental copper exposure has the potential to exert long lasting impacts to organismal growth, survival, and function.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Defect annihilation in heavy ion irradiated polycrystalline gold

In this study, we explore the interaction of electron wind force (EWF) with defects originating from ion irradiation in-situ inside a transmission electron microscope. Nanocrystalline gold specimens were self-ion irradiated to a dose of 5 × 10 15 ions/cm 2 (45 displacement per atom) to generate a high density of displacement damage. We also developed a molecular dynamics simulation model to understand the associated atomic scale mechanisms. Both experiments and simulations show that the EWF can impart significant defect mobility even at low temperatures, resulting in the migration and elimination of defects in a few minutes. Overall, we propose that the EWF interacts with defects to create highly glissile Shockley partial dislocations, which makes the fast and low temperature defect annihilation possible.

36 MATERIALS SCIENCE↗

A Simple, Revolutionary Approach to Waste Packaging Utilizing Proven Technology - 20201

Historically, removing hazardous waste from gloveboxes involves the use of bags as the primary containment method. This method can prove tedious, repetitive, and time consuming to ensure the process follows all safeguards required to contain the waste and mitigate any breach of containment. Layers of bags, yards of tape, and multiple filters are added to the waste stream in order to transfer the hazardous waste from the glovebox safely into the drum package. Then, finally, it can be shipped and disposed of. The process to cut, tie, and tape each bag for disposal involves manual effort by multiple operators. Following Administrative Safety Controls, good operators are able to safely perform those tasks; but, since the bag is the only confinement layer, incidents can occur. Operators, in some cases, are also at close proximity to this waste which may increase the risk of radiation exposure. Once the waste is transferred out through these bags, it is nearly impossible to remove packaged waste that may contain higher dosage levels, thus increasing drum disposal costs incurred by the facility. Exceeding the allowable radiation levels, and drums not fully filled, both contribute significantly to excess disposal costs. Central Research Laboratories (CRL), based in Red Wing Minnesota, has developed the Waste Drum Transfer System (WDTS) building upon the proven technology and containment of the Rapid Transfer Port (RTP) as an alternate, more efficient method of waste transfer. This solution consists of an RTP Alpha port mounted inside a glovebox and Beta assembly unit composed of a drum liner fitted inside a standard 55 gallon drum. The use of the Beta drum liner bypasses the typical use of bags, sleeves or tape to provide leak tight containment. The process to connect and disconnect a drum from the glovebox is achieved by the self-docking and rotating system controls of the RTP Alpha, all done with only one operator standing in an upright ergonomic position. This system also allows for greater flexibility in available Beta connection options, expanding the overall functionality of the system. This system can be disconnected and reconnected multiple times to maximize volume containment. This will minimize drum disposal costs and reduce the overall volume of waste output by more efficiently filling the drums. Radiation levels inside each drum can be monitored and adjusted more efficiently by operators utilizing the reconnect option. Minimal As Low As Reasonably Achievable (ALARA) levels are also achievable with this system. This paper will show how highly efficient packaging and disposal of hazardous waste can be accomplished in a cost-effective manner utilizing the proven RTP technology. Maximized operator productivity and safety, as well as minimized radiation dose exposure, are all attainable through the system's engineered controls. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

CMS High Granularity Calorimeter ECON-D ASIC overview and radiation testing results

The Compact Muon Solenoid (CMS) Experiment’s High Granularity Calorimeter (HGCAL) upgrade replaces the CMS electromagnetic and hadronic endcap calorimeters in preparation for the high-rate and high-radiation environment of the High Luminosity LHC. To effectively use the over 6 million channels of this highly-segmented “imaging” calorimeter, CMS is pioneering very front-end data compression with the Endcap Concentrator (ECON) ASICs – the ECON-T for the trigger path and the ECON-D for the data path. These 65 nm CMOS ASICs are radiation tolerant (200 Mrad) and low-power (< 2.5 mW/channel). In June 2023, we received the first full-functionality prototype of the data path concentrator ASIC, the ECON-D-P1. This talk will present an overview of the ECON-D-P1, summarize functionality and system testing, and present results from both Total Ionizing Dose (TID) and Single Event Effect (SEE) testing campaigns completed in summer 2023, validating the ECON-D radiation tolerant performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

New concept of radiolytic synthesis of gold nanoparticles in continuous flow

Radiolytic synthesis has been used to produce a plethora of unsupported and supported metallic nanoparticles in batch. As proof of a new concept, we evaluated the formation of gold nanoparticles by radiolytic synthesis in continuous flow using a millifluidic reactor. A mixture of gold ions solution, branched polyethyleneimine, and ethylene glycol yielded gold nanoparticles with a mean size of 3.4 ± 1.0 nm after irradiation with an X-ray irradiator (127 Gy/min) at an absorbed dose of 5.1 kGy. The morphology and size distribution of gold nanoparticles was influenced by AgNO 3 , where its absence resulted in a mean size of 20.9 ± 15.8 nm. The radiolytic synthesis of gold nanoparticles in continuous flow was achieved in short reaction times (<60 min), at room temperature, and with low concentrations of both stabilizing and reducing agents. Furthermore, these results demonstrate the potential of radiolytic synthesis in continuous flow for high-throughput formation of metallic nanoparticles with controlled specifications in size and distribution.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical and electrical properties of proton-implanted p -GaSb for electrical isolation

The effect of proton implantation as isolation implant and subsequent annealing on the optical absorption and electrical resistivity of low-bandgap p -GaSb is reported. The measured transmittance spectra indicates that implantation creates a distribution of energy levels extending into the bandgap. Electrical measurements show that the average sheet resistance of the implanted layer increases only by an order of magnitude from its pre-implantation value at a proton dose of ~10 13 cm -2 followed by 200 °C annealing. It is also shown that annealing reduces the implantation-induced optical absorption while still retaining a high electrical resistivity.

42 ENGINEERING↗

Use of the Manuela 3D/Radiation Scanning Tool at Nuclear Facilities - 20437

Licensees, facility operators and decommissioning contractors have a need for comprehensive, accurate and precise radiological and topographical data to plan and execute safe and efficient Decontamination and Decommissioning (D and D) projects. Traditional approaches rely greatly upon labor and administratively intensive data collection methods that require considerable time and effort to glean the relevant data to plan and perform work in a radiological work area. Orano Decommissioning Services has developed and utilized at French nuclear facilities a lightweight portable scanning instrument called MANUELA (Mobile Apparatus for Nuclear Expertise Localization Assistance). Recently Orano conducted demonstrations at two United States nuclear facilities using MANUELA that may prove useful in areas of the fuel cycle including: - ALARA (As Low As Reasonably Achievable) planning during facility operations; - Scoping and site characterization during the D and D planning phase; - Remedial action support during active decommissioning work; - Radiation and modeling planning for plant modifications; - Support Final Status Survey and demonstration of 'end state' compliance for license termination. MANUELA is currently being evaluated for use during decommissioning of nuclear facilities and could aide in demonstrating compliance with end state criteria after decommissioning. Of particular interest are decommissioning projects planned for various sites across the United States. Most of these sites present unique challenges and opportunities to safely and efficiently decommission in a regulatory compliant manner. The two demonstration site's current conditions of relatively low radiation levels inside containment proved to be ideal platforms to deploy the MANUELA instrument for evaluation of the complex geometries typically found in a nuclear facility. The MANUELA instrument was able to precisely identify local hot spots of the reactor system's primary equipment and was able to simultaneously overlay the dose information onto the scanned 3D images. Using data like this, a licensee would be able to make informed technical and personnel decisions on methods to remediate, shield or properly dispose of the radioactive source term. MANUELA can be used throughout the decommissioning process to validate progress and continue to refine the work activities to optimize the efforts of the crew which reduces downtime waiting for survey results, whereas traditional survey methodology relies on a physical survey to be performed and the data transcribed onto survey maps that are only two dimensional. The traditional format tends to be inaccurate and difficult to interpret the precise location(s) of hot spots or generalized dose rates. The resultant scan also allows the user to know the exact extent of the survey versus transposing information onto a map with only a portion of the map area scanned. MANUELA also compiles all of the relevant survey data into a downloadable table format which includes the measurement identification number, time stamp, point space location on the XYZ plane, and the dose rate value. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Nitrogen addition alters the relative importance of roots and mycorrhizal hyphae in regulating soil organic carbon accumulation in a karst forest

Plant belowground carbon (C) inputs from roots and associated mycorrhizal hyphae are increasingly recognized as critical drivers impacting soil organic C (SOC) pool. However, whether roots and mycorrhizal hyphae differentially regulate SOC formation and accumulation under elevated nitrogen (N) deposition remains to be addressed. Using an ingrowth-core technique, the relative contributions of roots and mycorrhizal hyphae to SOC accumulation were distinguished and quantified in a karst forest receiving three levels of N additions (control (0 kg N ha -1 yr -1 ), low N (150 kg N ha -1 yr -1 ) and high N (300 kg N ha -1 yr -1 )). Here our results showed that N addition stimulated SOC accumulation (indicated by the increase of both bulk SOC and mineral associated organic C fraction) influenced by both roots and hyphae, especially for higher N doses. Moreover, N addition increased the contribution of the root effect relative to the hyphal effect in the SOC accrual. The correlation analysis showed that, for the hyphal effect, the change in SOC content was solely and positively correlated with the change in protective mineral phases of SOC, but not with the microbial necromass. In contrast, for the root effect, the change in SOC content was significantly and positively correlated with the changes in both soil microbial C pump efficacy and protective mineral phases of SOC. These results suggest that roots and mycorrhizal hyphae may influence the accumulation of microbial necromass and the formation of mineral-organic associations in a different magnitude under enhanced N supply. These findings advance our understanding of the root-mycorrhizal interactions in mediating SOC dynamics in forests under future N deposition scenarios.

54 ENVIRONMENTAL SCIENCES↗

A multiscale model of the action of a capsid assembly modulator for the treatment of chronic hepatitis B

Chronic hepatitis B virus (HBV) infection is strongly associated with increased risk of liver cancer and cirrhosis. While existing treatments effectively inhibit the HBV life cycle, viral rebound frequently occurs following treatment interruption. Consequently, functional cure rates of chronic HBV infection remain low and there is increased interest in a novel treatment modality, capsid assembly modulators (CAMs). Here, we develop a multiscale mathematical model of CAM treatment in chronic HBV infection. By fitting the model to participant data from a phase I trial of the first-generation CAM vebicorvir, we estimate the drug’s dose-dependent effectiveness and identify the physiological mechanisms that drive the observed biphasic decline in HBV DNA and RNA, and mechanistic differences between HBeAg-positive and negative infection. Finally, we demonstrate analytically and numerically that the relative change of HBV RNA more accurately reflects the antiviral effectiveness of a CAM than the relative change in HBV DNA.

59 BASIC BIOLOGICAL SCIENCES↗

SRS Composite Analysis Monitoring Plan (FY2019 Model Validation)

Using a projected end-state date of 2065 (SRNS 2015b), the Savannah River Site (SRS) Composite Analysis (CA) modeling for each facility and waste site began on the inventory year assigned to it so that source depletion and radionuclide transport out of the system could be appropriately captured. Some SRS waste sites that have already achieved their end states (i.e. end-state inventories and end-state configuration) are currently contributing to the potential off-site public dose through source release, groundwater transport, discharge to on-site surface streams, and stream transport to the CA point of assessments (POAs). The inventory year assigned to these waste sites is 2002 or before. This means that SRS CA results from 2002 and beyond are a reasonable representation for these waste sites that have already achieved their end states and are currently contributing to the potential off-site public dose. The SRS Annual Environmental Report (AER) monitoring can differentiate and separate liquid pathway data allowing the data representing only waste sites at their end state to be produced. Because the SRS CA has projected reasonable end-state impacts from 2002 and beyond, and the AER monitoring can differentiate and separate operating and end-state contributions to annual liquid pathway release, an opportunity exists to use the AER monitoring data to validate the SRS CA model. The CA model validation program uses a graded and systematic approach for taking corrective action, starting with an SRS established administrative dose limit of 15 mrem/yr, below which no action is required. Based on the location of the 2010 SRS CA POAs, the only potential exposure pathway for the public is through surface water. The completion of the FY2019 CA model validation indicates that the SRS CA projected dose, while generally conservative, provides a reasonable representation of the maximum annual doses. These doses are well below the administrative limit; therefore, no additional action is required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A fusion relevant data-driven engineering void swelling model for 9Cr tempered martensitic steels

The UCSB database on cavity evolution in 9-12Cr tempered martensitic steels (TMS), includes the results for both dual heavy and helium ion (DII), and High Flux Isotope Reactor (HFIR) in situ helium injection (ISHI) neutron irradiations at 500°C. These results were combined with literature single ion and fission neutron irradiation data to derive a model for the void volume fraction, f v , as a function of displacements per atom (dpa) and transmutant helium concentrations in atomic parts per million (appm). The scientific foundation for the paper is described in a companion paper entitled “Cavity Evolution and Void Swelling in Dual Ion Irradiated Tempered Martensitic Steels”. Here, in this study, we show that f v (dpa, He/dpa) is described by the incubation dose, dpa i , for the onset of void growth, and the post-incubation growth rate, f v ’(%/dpa). Both dpa i and f v ’ decrease with increasing He/dpa at > ~ 5. The dpa i is also lower for the ISHI neutron irradiations at the same He/dpa. Single heavy ion and fission reactor neutron irradiations, with low He/dpa ratios, have a much larger dpa i . Based on a combined analysis of DII, single ion, ISHI and fission neutron data, we further show that the post-incubation f v data analyzed here have a common empirical curve shape, with f v ’ reaching up to ~ 0.2%/dpa at very high dpa. We also show that f v ’ can be predicted based on a physical model of defect partitioning between evolving sinks. At 500°C and fusion relevant He/dpa ≈ 10, the best-fit model predicts nominal swelling, S = f v /(1-f v ), of ~ 1.1, 4.9 and 16% at 50, 100 and 200 dpa, respectively. The physically motivated, data-driven model includes estimated uncertainties for both dpa i and f v ’.

36 MATERIALS SCIENCE↗

Imaging and dosimetric characteristics of 67 Cu

In recent years the use of beta-emitting radiopharmaceuticals for cancer therapy has expanded rapidly following development of therapeutics for neuroendocrine tumors, prostate cancer, and other oncologic malignancies. One emerging beta-emitting radioisotope of interest for therapy is 67 Cu (t 1/2 : 2.6 d) due to its chemical equivalency with the widely-established positron-emitting isotope 64 Cu (t 1/2 : 12.7 h). Here we evaluate both the imaging and dosimetric characteristics of 67 Cu, as well as producing the first report of SPECT/CT imaging using 67 Cu. To this end, 67 Cu was produced by photon-induced reactions on isotopically-enriched 68 Zn at the Low-Energy Accelerator Facility (LEAF) of Argonne National Laboratory, followed by bulk separation of metallic 68 Zn by sublimation and radiochemical purification by column chromatography. Gamma spectrometry was performed by efficiency-calibrated high-purity germanium (HPGe) analysis to verify absolute activity calibration and establish radionuclidic purity. Absolute activity measurements corroborated manufacturer-recommended dose-calibrator settings and no radionuclidic impurities were observed. Using the Clinical Trials Network anthropomorphic chest phantom, SPECT/CT images were acquired. Medium Energy (ME) SPECT collimation was found to provide the best image quality from the primary 185 keV gamma emission of 67 Cu. Reconstructed images of 67 Cu were similar in quality to images acquired using 177 Lu. Recovery coefficients were calculated and compared against quantitative images of 99m Tc, 177 Lu, and 64 Cu within the same anthropomorphic chest phantom. Production and clinical imaging of 67 Cu appears feasible, and future studies investigating the therapeutic efficacy of 67 Cu-based radiopharmaceuticals are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

State Policies on Access to Vaccination Services for Low-Income Adults

Importance State vaccination benefits coverage and access for adult Medicaid beneficiaries vary substantially. Multiple studies have documented lower vaccination uptake in publicly insured adults compared with privately insured adults. Objective To evaluate adult Medicaid beneficiaries’ access to adult immunization services through review of vaccination benefits coverage in Medicaid programs across the 50 states and the District of Columbia. Design, Setting, and Participants A public domain document review with supplemental semistructured telephone survey was conducted between June 1, 2018, and June 14, 2019, to evaluate vaccination services benefits in fee-for-service and managed care organization arrangements for adult Medicaid beneficiaries in the 50 states and the District of Columbia (total, 51 Medicaid programs). Exposures Document review of benefits coverage for adult immunization services and supplemental survey with validation of document review findings. Main Outcomes and Measures Benefits coverage for adult Medicaid beneficiaries and reimbursement amounts for vaccine purchase and administration. Results Public domain document review was completed for all 51 jurisdictions. Among these, 44 Medicaid programs (86%) validated document review findings and completed the survey. Only 22 Medicaid programs (43%) covered all 13 Advisory Committee on Immunization Practices–recommended adult immunizations under both fee-for-service and managed care organization arrangements. Most fee-for-service arrangements (37 of 49) reimbursed health care professionals using any of the 4 approved vaccine administration codes; however, 8 of 49 programs did not separately reimburse for vaccine administration to adult Medicaid beneficiaries. Depending on administration route, median reimbursement for adult vaccine administration ranged from $\$9.81$ to $\$13.98$ per dose. Median per-dose reimbursement for adult vaccine purchase was highest for 9-valent human papillomavirus vaccine ($\$204.87$) and lowest for Haemophilus influenzae type b vaccine ($\$18.09$). Median reimbursement was below the private sector price for 7 of the 13 included vaccines. Conclusions and Relevance Even in programs with complete vaccination benefits coverage, reimbursement amounts to health care professionals for vaccine purchase and administration may not fully cover vaccination provision costs. Reimbursement amounts below costs may reduce incentives for health care professionals to vaccinate low-income adults and thereby limit Medicaid adult beneficiary access to vaccination.

60 APPLIED LIFE SCIENCES↗

Exposure to ionizing radiation disrupts normal epigenetic aging in Japanese medaka

Alterations to the epigenome are a hallmark of biological aging and age-dependent patterning of the DNA methylome (“epigenetic aging”) can be modeled to produce epigenetic age predictors. Rates of epigenetic aging vary amongst individuals and correlate to the onset of age-related disease and all-cause mortality. Yet, the origins of epigenetic-to-chronological age discordance are not empirically resolved. Here, we investigate the relationship between aging, DNA methylation, and environmental exposures in Japanese medaka (Oryzias latipes). We find age-associated DNA methylation patterning enriched in genomic regions of low CpG density and that, similar to mammals, most age-related changes occur during early life. We construct an epigenetic clock capable of predicting chronological age with a mean error of 61.1 days (~8.4% of average lifespan). To test the role of environmental factors in driving epigenetic age variation, we exposed medaka to chronic, environmentally relevant doses of ionizing radiation. Because most organisms share an evolutionary history with ionizing radiation, we hypothesized that exposure would reveal fundamental insights into environment-by-epigenetic aging interactions. Radiation exposure disrupted epigenetic aging by accelerating and decelerating normal age-associated patterning and was most pronounced in cytosines that were moderately associated with age. These findings empirically demonstrate the role of DNA methylation in integrating environmental factors into aging trajectories.

60 APPLIED LIFE SCIENCES↗

Evaluation of silicon and indium gallium arsenide photodiodes as direct timing detectors for pulsed x-ray systems

Benchtop pulsed x-ray systems are commonly used to record dynamic material data on the order of nanoseconds, but pulse timing is often difficult to accurately determine. This study demonstrates that commercially available photodiodes can be used effectively for direct x-ray pulse detection without the need for visible light scintillators. X-ray pulses from four commercially available flash x-ray systems were quantified using one silicon and two indium gallium arsenide (InGaAs) photodiodes. The measured InGaAs pulse durations were strongly dependent on radiation dose in the non-linear operating regime, so the photodiodes were shielded to operate below the 2.5 V non-linear regime threshold. The average pulse duration and pulse arrival time jitter of the photodiodes for each x-ray source were within several nanoseconds with the exception of two sets of measurements that were affected by low instrument sensitivity and electrical noise. These results show that InGaAs photodiodes can be used as effective and repeatable stand-alone timing diagnostics for x-ray pulses as short as 20 ns or less.

47 OTHER INSTRUMENTATION↗

Comparison of time-resolved photoluminescence and deep-level transient spectroscopy defect evaluations in an InAs nBn detector subjected to in situ and ex situ 63 MeV proton irradiation

Deep-level transient spectroscopy and temperature-dependent time-resolved photoluminescence experiments are performed on identical InAs nBn photodetector structures as a function of in situ and ex situ 63 MeV proton irradiation to assess their generation and recombination dynamics. Pre-irradiation, the n-type InAs absorbing region, exhibits a steadily increasing minority carrier lifetime with increasing temperature, providing evidence that excited minority carriers may be recombining via shallow defect levels. From deep-level transient spectroscopy, two features are found between 10 and 275 K: a low temperature broad “shoulder,” which suggests emission from multiple shallow electron defect levels with energies <29 meV and a high temperature minimum occurring at ∼230 K with an activation energy of 539 meV, which suggests a defect in the barrier layer in the device. Two similar nBn detectors are then subjected to 63 MeV proton irradiation in step doses and measured between steps. One experiment is performed in situ with an nBn held at ∼10 K during dosing, and the other experiment is performed ex situ with a similar nBn held at room temperature for dosing. The ex situ dosing results in an evaluation of the defect introduction rate that is three to four times lower than in situ due to partial annealing of the proton-induced displacement damage at room temperature. The results of these two experiments are then compared with the dose-dependent recombination rate analysis, resulting in an estimated recombination defect cross section of 1.6 × 10 −13 cm 2 for the shallow shoulder defect.

Carrasco, Rigo A. [Air Force Research Laboratory (↗

A radiation tolerant clock generator for the CMS endcap timing layer readout chip

Here, we present the test results of a low jitter Phase Locked Loop (PLL) prototype chip for the CMS Endcap Timing Layer readout chip (ETROC). This chip is based on the improved version of a clock synthesis circuit named ljCDR from the Low Power Gigabit Transceiver (lpGBT) project. The ljCDR is tested in its PLL mode. An automatic frequency calibration (AFC) block with the Triple Modular Redundancy (TMR) register is developed for the LC-oscillator calibration. The chip was manufactured in a 65 nm CMOS process with 10 metal layers. The chip has been extensively tested, including Total Ionizing Dose (TID) testing up to 300 Mrad and Single Event Upset (SEU) testing with heavy ions possessing a Linear Energy Transfer (LET) from 1.3 to 62.5 MeV × cm 2 /mg.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On the Radiation Effects of Strontium Ions on Satellite Solar Cells in Low Earth Orbits

This study focuses on the radiation effects 19 of Sr + ions—generated from high-altitude nuclear explosions (HANE)—on satellite solar cells in low-Earth orbits (LEO). Along four selected satellite orbits, ion fluences are sampled inside the evolving Sr + distributions for days, determined from our newly developed HANE environment model. These fluences, along with the help of radiation transport codes including the MULASSIS and SRIM models, enable us to quantify the radiation damages by determining the values of total ionizing doses and the equivalent 1 MeV electron fluences for displacement damages. Comparing the dose values to existing experimental data, we conclude that HANE-generated Sr + ions have limited darkening effects to quartz solar cell coverglasses in LEO with apogees of 100s to 1000 km. In addition, with the extremely high equivalent fluences, we also conclude that these Sr+ ions may cause severe or even fatal displacement damage to exposed solar photovoltaic (PV) cells on satellites in LEO. The radiation effects of Sr + ions are much less significant for the orbits with high apogees beyond ten thousand km. We also conducted model parameter sensitivity studies on the charge exchange cross-sections, neutral atmosphere density profiles and explosion local time positions, and the above conclusions stay unchanged. The methodology developed in this study can be extended to other HANE-generated heavy ion species in the future.

14 SOLAR ENERGY↗