Low Q{sup 2} Measurement of g{sub 2}{sup p} and the delta{sub LT} Spin Polarizability

JLab has been at the forefront of a program to measure the nucleon spin-dependent structure functions over a wide kinematic range, and data of unprecedented quality has been extracted in all three experimental halls. Moments of these quantities have proven to be powerful tools to test QCD sum rules and provide benchmark tests of Lattice QCD and Chiral Perturbation Theory. Precision measurements of g{sub 1,2}{sup n} and g{sub 1}{sup p} have been performed as part of the highly successful 'extended GDH program', but data on the g{sub 2}{sup p} structure function remain scarce. We discuss here JLab experiment E08-027, which will measure g{sub 2}{sup p} in the resonance region at low Q{sup 2}. These data will be used to test the Burkhardt-Cottingham sum rule and to extract the higher moments delta{sub LT}{sup p}(Q{sup 2}) and d-bar{sub 2}{sup p}(Q{sup 2}). Data in the Q{sup 2} range 0.02<Q{sup 2}<0.4 GeV{sup 2} will provide unambiguous benchmark tests of chi{sup PT} calculations on the lower end, while probing the transition region at the high Q{sup 2} end where parton-like behaviour begins to emerge. This data will also have a significant impact on our theoretical understanding of the hyperfine structure of the proton, and reduce the systematic uncertainty of previous experiments which extracted the g{sub 1}{sup p} structure from purely longitudinal measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Calorimetric low temperature detectors for low-energetic heavy ions and their application in accelerator mass spectrometry

The energy-sensitive detection of heavy ions with calorimetric low temperature detectors was investigated in the energy range of E=0.1-1 MeV/amu, commonly used for accelerator mass spectrometry (AMS). The detectors used consist of sapphire absorbers and superconducting aluminum transition edge thermometers operated at T{approx}1.5 K. They were irradiated with various ion beams ({sup 13}C,{sup 197}Au,{sup 238}U) provided by the VERA tandem accelerator in Vienna, Austria. The relative energy resolution obtained was {Delta}E/E=(5-9)x10{sup -3}, even for the heaviest ions such as {sup 238}U. In addition, no evidence for a pulse height defect was observed. This performance allowed for the first time to apply a calorimetric low temperature detector in an AMS experiment. The aim was to precisely determine the isotope ratio of {sup 236}U/{sup 238}U for several samples of natural uranium, {sup 236}U being known as a sensitive monitor for neutron fluxes. Replacing a conventionally used detection system at VERA by the calorimetric detector enabled to substantially reduce background from neighboring isotopes and to increase the detection efficiency. Due to the high sensitivity achieved, a value of {sup 236}U/{sup 238}U=6.1x10{sup -12} could be obtained, representing the smallest {sup 236}U/{sup 238}U ratio measured at the time. In addition, we contributed to establishing an improved material standard of {sup 236}U/{sup 238}U, which can be used as a reference for future AMS measurements.

43 PARTICLE ACCELERATORS↗

The Neutron and {sup 3}He Spin Structure Functions at Low Q{sup 2}

Experiment E97-110 was performed at the Thomas Jefferson National Accelerator Facility in Hall A to provide a precise measurement of the moments of the neutron and {sup 3}He spin structure functions. A longitudinally-polarized electron beam was scattered from a longitudinally or transversely polarized {sup 3}He target. The extended Gerasimov-Drell-Hearn integral and other moments of the neutron and {sup 3}He spin structure functions were extracted at very low momentum transfers (0.02<Q{sup 2}<0.3 [GeV/c]{sup 2}). These data allow us to make a benchmark check of Chiral Perturbation Theory calculations in a region where they are expected to be valid. In these proceedings, the experimental details are discussed and preliminary results on the moments of the spin structure functions are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High Precision Measurement of the Proton Elastic Form Factor Ratio at Low Q{sup 2}

A high precision measurement of the proton elastic form factor ratio {mu}{sub p}G{sub Ep}/G{sub Mp} in the range Q{sup 2} = 0.3-0.7 GeV{sup 2}/c{sup 2} was performed using recoil polarimetry in Jefferson Lab Hall A. In this low Q{sup 2} range, previous data from LEDEX [5] along with many fits and calculations [2, 3, 4] indicate substantial deviations of the ratio from unity. In this new measurement, with 80% polarized electron beam for 24 days, we are able to achieve <1% statistical uncertainty. Preliminary results are a few percent lower than expected from previous world data and fits, indicating a smaller G{sub Ep} at this region. Beyond the intrinsic interest in nucleon structure, the improved form factor measurements also have implications for DVCS, determinations of the proton Zemach radius and strangeness form factors through parity violation experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

HUGONIOT MEASUREMENTS AT LOW PRESSURES IN TIN USING 800 MeV PROTON RADIOGRAPHY

A 20 mm long 8 mm diameter cylindrical tin target has been shocked to a pressure just below the beta->gamma phase change, using a small, low density PETN charge mounted on the opposite side of a thin stainless steel diaphragm. The density jump and shock velocity were measured radiographically at multiple points as the shock wave moved though the sample and the pressure dropped, using the proton radiography facility at LANL. This provided a quasi-continuous record along the principal Hugoniot from a peak shock velocity of 3.27 km/sec to a minimum of 3.09 km/sec. Edge release effects were removed from the data using simple tomographic reconstruction techniques. The data and analysis are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrojet-independent ionospheric extremely low frequency/very low frequency wave generation by powerful high frequency waves

Results of extremely low frequency/very low frequency (ELF/VLF) wave generation by intensity-modulated high frequency (HF) heaters of 3.2 MHz in Gakona, Alaska, near local solar noon during a geomagnetic quiet time, are presented to support an electrojet-independent ELF/VLF wave generation mechanism. The modulation was set by splitting the HF transmitter array into two subarrays; one was run at cw full power and the other run alternatively at 50% and 100% power modulation by rectangular waves of 2.02, 5, 8, and 13 kHz. The most effective generation was from the X-mode heater with 100% modulation. While the 8 kHz radiation has the largest wave amplitude, the spectral intensity of the radiation increases with the modulation frequency, i.e., 13 kHz line is the strongest. Ionograms recorded significant virtual height spread of the O-mode sounding echoes. The patterns of the spreads and the changes of the second and third hop virtual height traces caused by the O/X-mode heaters are distinctively different, evidencing that it is due to differently polarized density irregularities generated by the filamentation instability of the O/X-mode HF heaters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shear flow-driven electrostatic instabilities in low density and low temperature pair-ion plasmas with and without electrons

The shear flow-driven electrostatic instabilities are investigated in ideal low density, low temperature pair-ion-electron and pure pair-ion plasmas in several different cases, including homogeneous and inhomogeneous density effects. In uniform pair-ion-electron plasma, when the shear flow is of the order of the acoustic speed, the purely growing D'Angelo mode can give rise to electrostatic fields. In the case of an inhomogeneous plasma, the drift wave becomes unstable. The presence of negative ions, however, reduces the growth rate. If the positive and negative ions are not in thermal equilibrium with each other, then the shear flow also gives rise to an electrostatic instability in pure pair-ion plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A low emittance and high efficiency visible light photocathode for high brightness accelerator-based X-ray light sources

Free-electron lasers and energy recovery linacs represent a new generation of ultra-high brightness electron accelerator based x-ray sources. Photocathodes are a critical performance-limiting component of these systems. Here, we describe the development of photocathodes based on potassium-cesium-antimonide that satisfy many of the key requirements of future light sources, such as robustness, high quantum efficiency when excited with visible light, and low transverse emittance.

43 PARTICLE ACCELERATORS↗

A shallow underground laboratory for low-background radiation measurements and materials development

Pacific Northwest National Laboratory recently commissioned a new shallow underground laboratory, located at a depth of approximately 30 meters-water-equivalent. This new addition to the small class of radiation measurement laboratories located at modest underground depths houses the latest generation of custom-made, high-efficiency, low-background gamma-ray spectrometers and gas proportional counters. This paper describes the unique capabilities present in the shallow underground laboratory; these include large-scale ultra-pure materials production and a suite of radiation detection systems. Reported data characterize the degree of background reduction achieved through a combination of underground location, graded shielding, and rejection of cosmic-ray events. We conclude by presenting measurement targets and future opportunities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutralization of space charge on high-current low-energy ion beam by low-energy electrons supplied from silicon based field emitter arrays

Neutralization of space charge on a high-current and low-energy ion beam was attempted to reduce the divergence with an aid of low-energy electrons supplied from silicon based field emitter arrays (Si-FEAs). An argon ion beam with the energy of 500 eV and the current of 0.25 mA was produced by a microwave ion source. The initial beam divergence and the emittance were measured at the entrance of the analysis chamber in order to estimate the intrinsic factors for beam divergence. The current density distribution of the beam after transport of 730 mm was measured by a movable Faraday cup, with and without electron supply from Si-FEAs. A similar experiment was performed with tungsten filaments as an electron source. The results indicated that the electron supply from FEA had almost the same effect as the thermionic filament, and it was confirmed that both electron sources can neutralize the ion beam.

43 PARTICLE ACCELERATORS↗

Initial Characterization of Unequal-Length, Low-Background Proportional Counters for Absolute Gas-Counting Applications

Abstract. Characterization of two sets of custom unequal length proportional counters is underway at Pacific Northwest National Laboratory (PNNL). These detectors will be used in measurements to determine the absolute activity concentration of gaseous radionuclides (e.g., 37Ar). A set of three detectors has been fabricated based on previous PNNL ultra-low-background proportional counters (ULBPC) designs and now operate in PNNL’s shallow underground counting laboratory. A second set of four counters has also been fabricated using clean assembly of OFHC copper components for use in an above-ground counting laboratory. Characterization of both sets of detectors is underway with measurements of background rates, gas gain, energy resolution, and shielding considerations. These results will be presented along with uncertainty estimates of future absolute gas counting measurements.

Mace, Emily K.↗

Low temperature spin dynamics in Cr{sub 7}Ni-Cu-Cr{sub 7}Ni coupled molecular rings

Proton Nuclear Magnetic Resonance (NMR) relaxation measurements have been performed down to very low temperature (50 mK) to determine the effect of coupling two Cr{sub 7}Ni molecular rings via a Cu{sup 2+} ion. No difference in the spin dynamics was found from nuclear spin lattice relaxation down to 1.5 K. At lower temperature, the {sup 1}H-NMR line broadens dramatically indicating spin freezing. From the plot of the line width vs. magnetization, it is found that the freezing temperature is higher (260 mK) in the coupled ring with respect to the single Cr{sub 7}Ni ring (140 mK)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low temperature crystal structure and magnetic properties of RAl{sub 2}

Low temperature crystal structure and magnetic properties of RAl{sub 2} (R = Pr and Nd) have been studied using temperature dependent powder x-ray diffraction, magnetization, and heat capacity measurements. Unlike PrAl{sub 2}, NdAl{sub 2} retains cubic MgCu{sub 2}-type structure from room temperature down to 5 K, which is also confirmed from first principles electronic structure calculations. The magnetization measurements show both PrAl{sub 2} and NdAl{sub 2} order ferromagnetically at T{sub C} = 32 K and 77 K, respectively. However, the magnetization measurements show the former is a hard ferromagnet compared to the latter which is a soft ferromagnetic material. The magnetic entropy change obtained from heat capacity measurements at ΔH = 30 kOe for PrAl{sub 2} and NdAl{sub 2} are 3.15 J mol{sup −1} K{sup −1} and 1.18 J mol{sup −1} K{sup −1}, respectively.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Generalizing the self-healing diffusion Monte Carlo approach to finite temperature: A path for the optimization of low-energy many-body bases

A statistical method is derived for the calculation of thermodynamic properties of many-body systems at low temperatures. This method is based on the self-healing diffusion Monte Carlo method for complex functions [F. A. Reboredo, J. Chem. Phys. 136, 204101 (2012)] and some ideas of the correlation function Monte Carlo approach [D. M. Ceperley and B. Bernu, J. Chem. Phys. 89, 6316 (1988)]. In order to allow the evolution in imaginary time to describe the density matrix, we remove the fixed-node restriction using complex antisymmetric guiding wave functions. In the process we obtain a parallel algorithm that optimizes a small subspace of the many-body Hilbert space to provide maximum overlap with the subspace spanned by the lowest-energy eigenstates of a many-body Hamiltonian. We show in a model system that the partition function is progressively maximized within this subspace. We show that the subspace spanned by the small basis systematically converges towards the subspace spanned by the lowest energy eigenstates. Possible applications of this method for calculating the thermodynamic properties of many-body systems near the ground state are discussed. The resulting basis can also be used to accelerate the calculation of the ground or excited states with quantum Monte Carlo.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In situ examination of oxygen non-stoichiometry in La{sub 0.80}Sr{sub 0.20}CoO{sub 3−δ} thin films at intermediate and low temperatures by x-ray diffraction

Structural evolution of epitaxial La{sub 0.80}Sr{sub 0.20}CoO{sub 3−δ} thin films under chemical and voltage stimuli was examined in situ using X-ray diffraction. The changes in lattice parameter (chemical expansivity) were used to quantify oxygen reduction reaction processes and vacancy concentration changes in lanthanum strontium cobaltite. At 550 °C, the observed lattice parameter reduction at an applied bias of −0.6 V was equivalent to that from the reducing condition of a 2% carbon monoxide atmosphere with an oxygen non-stoichiometry δ of 0.24. At lower temperatures (200 °C), the application of bias reduced the sample much more effectively than a carbon monoxide atmosphere and induced an oxygen non-stoichiometry δ of 0.47. Despite these large changes in oxygen concentration, the epitaxial thin film was completely re-oxidized and no signs of crystallinity loss or film amorphization were observed. This work demonstrates that the effects of oxygen evolution and reduction can be examined with applied bias at low temperatures, extending the ability to probe these processes with in-situ analytical techniques.

36 MATERIALS SCIENCE↗

Ultra-low noise high electron mobility transistors for high-impedance and low-frequency deep cryogenic readout electronics

We report on the results obtained from specially designed high electron mobility transistors at 4.2 K: the gate leakage current can be limited lower than 1 aA, and the equivalent input noise-voltage and noise-current at 1 Hz can reach 6.3 nV/Hz{sup 1∕2} and 20 aA/Hz{sup 1∕2}, respectively. These results open the way to realize high performance low-frequency readout electronics under very low-temperature conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗