At least 469 records · Page 26

Modeling Exhaust-Generated Aerodynamic Pressure Loads on Airfield Matting Repair Systems

Airfield matting systems are commonly used for rapid repair of damaged runways to facilitate continuity of critical operations. Under normal service conditions, matting repair systems are subject not only to wheel loads exerted by airfield traffic but also to aerodynamic pressure loads resulting from high-speed, turbulent exhaust plumes produced by jets during taxi and take-off. Matting systems employed by the U.S. Air Force have been tested with respect to wheel loads, but probabilities of failure because of pressure loads produced by jet exhaust have not yet been established. This study presents a numerical approach for preliminary estimation of worst-case matting anchor forces resulting from exhaust-generated pressure loads. Using a two-dimensional computational fluid dynamics model, system behavior is evaluated by means of a parametric study of six system variables, of which the most significant are: (1) distance between engine and matting, (2) depth of cavity openings at matting edges, and (3) engine exhaust velocity. The results demonstrate that matting systems are likely to experience net uplift in typical service scenarios, driven by the combined effects of flow separation and cavity pressurization. Worst-case anchor pull-out forces, computed according to a tributary-area approach, are estimated to fall in the range of 130 lb (581 N) to 979 lb (4,350 N), depending on assumed load-sharing behavior among anchors and the size of the repair site. Field testing of instrumented matting systems during jet taxi and take-off sequences is recommended as the best next step toward understanding system behavior.

Engineering↗

Predicting ductility of Mg/SiCp nanocomposite under multiaxial loading conditions based on unit cell modeling

This article presents an investigation on the ductility of Mg/SiCp under nine different multiaxial loading conditions based on a unit cell (or called representative volumetric element, RVE) finite element model. The constitutive relationship of magnesium matrix is characterized by a model combined Lode angle dependent plasticity model with the CPB06 plasticity model, which is able to describe the tension-compression asymmetry in magnesium matrix. The debonding of the matrix-particle interface and matrix fracture are considered by the modified Mohr-Coulomb (MMC) fracture model. Simulation results show that the interface debonding and subsequent matrix fracture are responsible for the ductility and fracture of nanocomposite. The computational results with parametric studies are compared and well correlated with experimental data, and it finally gives a stress-based full fracture locus of Mg/SiCp nanocomposite.

42 ENGINEERING↗

Reconfigurable Real-Time Power Grid Emulator for Systems With High Penetration of Renewables

Novel power system control and new utility devices need to be tested before their actual deployment to the power grid. To assist with such a testing need, real-time digital emulators such as RTDS and Opal-RT can be used to connect to the physical world and form a hardware in the loop (HIL) emulation. However, due to the limitations of today's computational resources, the accuracy and fidelity suffer from different levels of model reductions in purely digital simulations. CURENT has developed a reconfigurable electric grid hardware testbed (HTB) to overcome the limitations of digital emulators. The HTB has been used to develop measurement, control, modeling, and actuation techniques for a national grid with a high penetration of renewables. The power electronic-based system includes emulators for synchronous generators; photovoltaics with grid-interfacing inverter; wind turbines; induction motor loads, ZIP loads, power electronic loads; batteries; ac and dc transmission lines; short circuit faults and grid relay protection; and a multiterminal HVDC overlay including power electronics interfaces. The system contains real elements of power flow, measurement, communication, protection, and control that mimic what would be seen in an actual electric grid. This paper presents an overview of the HTB and several scenarios that have been run to determine control and actions needed for the future power grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coordination of Behind-the-Meter Energy Storage and Building Loads: Optimization with Deep Learning Models*

With the increasing penetration of renewable energy systems and energy storage systems in buildings, it is critical to optimize system operation. In this paper, we develop an optimization strategy to minimize the operation cost as well as maintain indoor thermal comfort, for a building integrated with battery and PV. A Recurrent Neural Network (RNN) is used to predict building thermal load and zone temperatures. A black-box optimization algorithm known as nonlinear optimization by mesh adaptive direct search (NOMADS) is employed in simulation to provide look-ahead optimal battery dispatch and zone temperature set-point schedules so that the operation cost is minimized. Field data collected from a medium sized office building at Pacific Northwest National Laboratory (PNNL) integrated with Photovoltaic (PV) system model and battery storage system model is used to demonstrate the proposed methodology. Compared with rule based methods, the optimization strategy obtained a lower cost of operation while satisfying comfort constraints.

Chen, Yimin↗

Agro-IBIS/THMB Modeled Yield, Nitrogen Loss, and Profitability Maps for the Raccoon River Basin, Iowa, USA

This data was used to assess the potential for improving water quality in this watershed when integrating miscanthus, a bioenergy perennial grass, on to areas of low profit under current corn-soybean management and areas of high nitrogen leaching under both current and future climate conditions. This dataset includes all observations (yield, streamflow, nitrogen loads) and model simulation data used from Dr. Kelsie Ferin’s (former PhD student with Dr. Andy VanLoocke, ISU Dept. of Agronomy) dissertation and publication in Global Change Biology – Bioenergy (DOI: 10.1111/gcbb.13078). Modeled output included in this dataset includes corn, soybean, and miscanthus yields, nitrogen leaching rates, net mineralization rates, land use cover fractions with and without the inclusion of miscanthus, profitability maps, additional soil property maps, and simulated streamflow and nitrogen loads near the outlet of the Raccoon River Basin (Van Meter, Iowa) for both historical and future climate conditions. This dataset includes a mixture of netCDF, .tiff, .csv, and .xlsx files. See README.pdf for more information.

Ferin, Kelsie↗

A methodology for generating reduced-order models for large-scale buildings using the Krylov subspace method

Developing a computationally efficient but accurate building energy simulation (BES) model is important for many purposes. Model order reduction (MOR) methods are attractive and much more reliable than identification approaches, since it directly extract a lower-dimensional model from a detailed physics-based model without any pre-simulations. However, because of computational and data storage requirements, there are challenges of applying these methods to a large-scale building. To overcome the problem, this work introduces the Krylov subspace method to the building science field. Technical issues of applying the method to building applications are addressed and a suitable algorithm that overcomes those challenges is presented. Furthermore, to demonstrate the reliability of the algorithm, comparisons between the resulted reduced-order model (ROM) and a high-fidelity model from a commercial BES software for a 60-zone case study building are provided. The ROM was a factor of 100 faster than the high fidelity model but with high accuracy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Balancing Power Absorption Against Structural Loads With Viscous Drag and Power-Takeoff Efficiency Considerations

The focus of this paper is to balance power absorption against structural loading for a novel fixed-bottom oscillating surge wave energy converter in both regular and irregular wave environments. The power-to-load ratio will be evaluated using pseudospectral control (PSC) to determine the optimum power-takeoff (PTO) torque based on a multiterm objective function. This paper extends the pseudospectral optimal control problem to not just maximize the time-averaged absorbed power but also include measures for the surge-foundation force and PTO torque in the optimization. The objective function may now potentially include three competing terms that the optimizer must balance. Separate weighting factors are attached to the surge-foundation force and PTO control torque that can be used to tune the optimizer performance to emphasize either power absorption or load shedding. To correct the pitch equation of motion, derived from linear hydrodynamic theory, a quadratic-viscous-drag torque has been included in the system dynamics; however, to continue the use of quadratic programming solvers, an iteratively obtained linearized drag coefficient was utilized that provided good accuracy in the predicted pitch motion. Furthermore, the analysis considers the use of a nonideal PTO unit to more accurately evaluate controller performance. The PTO efficiency is not directly included in the objective function but rather the weighting factors are utilized to limit the PTO torque amplitudes, thereby reducing the losses resulting from the bidirectional energy flow through a nonideal PTO. Furthermore, results from PSC show that shedding a portion of the available wave energy can lead to greater reductions in structural loads, peak-to-average power ratio, and reactive power requirement.

16 TIDAL AND WAVE POWER↗

Asymptotic Representation for the Eigenvalues of a Non-selfadjoint Operator Governing the Dynamics of an Energy Harvesting Model

We consider a well known model of a piezoelectric energy harvester. The harvester is designed as a beam with a piezoceramic layer attached to its top face (unimorph configuration). A pair of thin perfectly conductive electrodes is covering the top and the bottom faces of the piezoceramic layer. These electrodes are connected to a resistive load. The model is governed by a system consisting of two equations. The first of them is the equation of the Euler–Bernoulli model for the transverse vibrations of the beam and the second one represents the Kirchhoff’s law for the electric circuit. Both equations are coupled due to the direct and converse piezoelectric effects. The boundary conditions for the beam equations are of clamped-free type. We represent the system as a single operator evolution equation in a Hilbert space. The dynamics generator of this system is a non-selfadjoint operator with compact resolvent. Our main result is an explicit asymptotic formula for the eigenvalues of this generator, i.e., we perform the modal analysis for electrically loaded (not short-circuit) system. We show that the spectrum splits into an infinite sequence of stable eigenvalues that approaches a vertical line in the left half plane and possibly of a finite number of unstable eigenvalues. This paper is the first in a series of three works. In the second one we will prove that the generalized eigenvectors of the dynamics generator form a Riesz basis (and, moreover, a Bari basis) in the energy space. In the third paper we will apply the results of the first two to control problems for this model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-F-16A-02: Simulation of a Medical Linear Accelerator for Teaching Purposes

Purpose: Detailed functioning of linear accelerator physics is well known. Less well developed is the basic understanding of how the adjustment of the linear accelerator's electrical components affects the resulting radiation beam. Other than the text by Karzmark, there is very little literature devoted to the practical understanding of linear accelerator functionality targeted at the radiotherapy clinic level. The purpose of this work is to describe a simulation environment for medical linear accelerators with the purpose of teaching linear accelerator physics. Methods: Varian type lineacs were simulated. Klystron saturation and peak output were modelled analytically. The energy gain of an electron beam was modelled using load line expressions. The bending magnet was assumed to be a perfect solenoid whose pass through energy varied linearly with solenoid current. The dose rate calculated at depth in water was assumed to be a simple function of the target's beam current. The flattening filter was modelled as an attenuator with conical shape, and the time-averaged dose rate at a depth in water was determined by calculating kerma. Results: Fifteen analytical models were combined into a single model called SIMAC. Performance was verified systematically by adjusting typical linac control parameters. Increasing klystron pulse voltage increased dose rate to a peak, which then decreased as the beam energy was further increased due to the fixed pass through energy of the bending magnet. Increasing accelerator beam current leads to a higher dose per pulse. However, the energy of the electron beam decreases due to beam loading and so the dose rate eventually maximizes and the decreases as beam current was further increased. Conclusion: SIMAC can realistically simulate the functionality of a linear accelerator. It is expected to have value as a teaching tool for both medical physicists and linear accelerator service personnel.

43 PARTICLE ACCELERATORS↗

Analysis & Tools to Spur Increased Deployment of “Waste Heat” Rejection/Recycling Hybrid Ground-source Heat Pump Systems in Hot, Arid or Semiarid Climates Like Texas

This project team analyzed supplemental heat rejection/recovery (SHR) devices or systems that could be used in hybrid ground source heat pump (HGHP) systems located in arid or semi-arid regions in southwestern U.S. Identification of effective SHR solutions would enhance the deployment of ground source heat pumps (GHP) in these regions. In a parallel effort, the team developed integrated GHP models that coupled the building load, heat pump, and ground loop subsystems and which could be applied to residential and commercial office buildings. Then GHP and HGHP performances could be compared in terms of operational performance and life-cycle costs. Several potential SHR devices were analyzed by applying two strategies: 1) to remove heat directly from the water in the ground loop before it enters the ground and 2) to remove heat in the refrigerant loop of the vapor compression cycle (VCC) of the heat pump so less heat is transferred to the water loop at the condenser of the VCC. Cooling towers, adsorption coolers, and thermoelectric liquid coolers were included in strategy 1, and expanded desuperheaters, thermosyphons, and an optimized VCC were included in strategy 2. Of all SHR devices analyzed, only the cooling tower provided a cost-effective performance enhancement. For the integrated GHP model, the project team selected the building load model HAMBASE and its powerful computational Simulink/MatLab platform, empirical performance map models of the heat pumps based upon manufacturers’ performance data, and a ground loop model developed by Oklahoma State University and rewritten for this project in Simulink/MatLab. The design process used GLHEPRO, also from Oklahoma State University, to size the borehole fields. The building load and ground loop models were compared with simulations from eQuest, ASHRAE 140-2008 standards, EnergyPlus, and GLHEPRO and were found to predict those subsystems’ performance well. The integrated GHP model was applied to a 195m 2 (2100ft 2 ) residential building and a 4,982m 2 (53,628ft 2 ) three-story commercial office building, and it ran 10-15 year simulations. The integrated GHP model and its Simulink platform provided residential data, ranging from seconds to years, and commercial office building data, ranging from minutes to years. A cooling tower model was coupled to the base case integrated GHP model for the residential building and the resulting HGHP system provided a cost-effective solution for the Austin, TX location. Simulations for both the residential and commercial building models were run with varying degrees of SHR (device/system not identified) and the results were found to significantly decrease installation costs, increase heat pump efficiency (lower entering water temperature), and prolong the lifetime of the borehole field. Lifetime cycle costs were estimated from the simulation results. Sensitivity studies on system operating performance and lifetime costs were performed on design parameters, such as construction materials, borehole length, borehole configuration and spacing, grout conductivity, and effects of SHR. While some of the results are intuitive, these studies provided quantitative estimates of improved performance and cost. One of the most important results of this sensitivity study is that overall system performance is very sensitive to these design parameters and that modeling and simulation are essential tools to design cost-effective systems.

15 GEOTHERMAL ENERGY↗

Development of a Dynamic Model and Control System for Load-Following Studies of Supercritical Pulverized Coal Power Plants

Traditional energy production plants are increasingly forced to cycle their load and operate under low-load conditions in response to growth in intermittent renewable generation. A plant-wide dynamic model of a supercritical pulverized coal (SCPC) power plant has been developed in the Aspen Plus Dynamics® (APD) software environment and the impact of advanced control strategies on the transient responses of the key variables to load-following operation and disturbances can be studied. Models of various key unit operations, such as the steam turbine, are developed in Aspen Custom Modeler® (ACM) and integrated in the APD environment. A coordinated control system (CCS) is developed above the regulatory control layer. Three control configurations are evaluated for the control of the main steam; the reheat steam temperature is also controlled. For studying servo control performance of the CCS, the load is decreased from 100% to 40% at a ramp rate of 3% load per min. The impact of a disturbance due to a change in the coal feed composition is also studied. The CCS is found to yield satisfactory performance for both servo control and disturbance rejection.

20 FOSSIL-FUELED POWER PLANTS↗

THERMAL MODELING OF HANFORD CESIUM AND STRONTIUM CANISTERS DURING SIMULATED LOADING

A computational fluid dynamics (CFD) model was built to simulate planned testing of heater assemblies within a canister and overpack for the Hanford Lead Canister (HLC) project. The HLC is a canister storage system that will contain heaters to simulate the decay heat of nuclear material and provide the canister storage system with environmental conditions equivalent to the operating conditions on a dry storage pad. The HLC will be equipped with long-term data collection and monitoring systems to provide an early warning of corrosion, pitting, cracking, or other signs of canister degradation that might threaten the integrity of the containment boundary over the potentially long term of dry storage. An important part of the HLC development is to make pretest numerical predictions for the behavior of the heated canister during the simulated radiolytic decay heat testing, which simulates the dry storage system during loading operations. The simulated radiolytic decay heat test is planned for mid-2024 in a configuration that includes the heater assembly, overpack, and canister, but with the lids removed to allow loading cesium and strontium capsules into the canister. One of the goals of the test is to evaluate the thermal behavior of the canister and overpack assembly in the ambient air of the test facility, which will provide data critical to validating the thermal models and understanding how the HLC will perform as a system once deployed. To best approximate real-world conditions, the CFD model includes the full air volume of the mock-up truck bay the heated canister test will be performed in, enabling detailed investigation of how the heated canister affects airflow around it. Rigorous pre-deployment testing of the complete HLC cask and canister system is intended to be completed before the HLC is deployed in the 2028 timeframe. This study presents the pre-test temperature predictions of the simulated radiolytic decay heat test. A description of the heater assembly, canister, and overpack system is presented. The model was developed with the commercial CFD software STAR-CCM+. An uncertainty analysis was run with the CFD model to determine the uncertainty in the temperature predictions and provide a range over which the predicted temperatures are expected to vary. The uncertainty analysis was preformed by coupling STAR-CCM+ with the software Dakota, which provides advanced parametric analyses, including quantification of margins and uncertainty with computational models. This work is expected to provide insight into SNF canister behavior.

Carpenter-Graffy, Dina E.↗

End-Use Load Profiles for the U.S. Building Stock: Market Needs, Use Cases, and Data Gaps

This report serves as the first-year deliverable for a multiyear project that intends to produce a set of highly resolved electricity end-use load profiles (EULPs) of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End Use Load Profiles for the U.S. Building Stock

End Use Load Profiles for the U.S. Building Stock is a multiyear project to produce a set of highly resolved electricity end-use load profiles (EULPs) of the U.S. residential and commercial building stock. The project team, made up of researchers from the National Renewable Energy Laboratory (NREL), Lawrence Berkeley National Laboratory (LBNL), and Argonne National Laboratory, ultimately will use calibrated physics-based building energy models to create these EULPs. This presentation provides an overview of the project approach, status, goals, and challenges, and discusses what the project means for the Northeast region.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Load Control Using Distributionally Robust Chance-Constrained Programs with Right-Hand Side Uncertainty and the Risk-Adjustable Variants

Aggregation of heating, ventilation, and air conditioning (HVAC) loads can provide reserves to absorb volatile renewable energy, especially solar photo-voltaic (PV) generation. In this paper, we decide HVAC control schedules under uncertain PV generation, using a distributionally robust chance-constrained (DRCC) building load control model under two typical ambiguity sets: the moment-based and Wasserstein ambiguity sets. We derive mixed integer linear programming (MILP) reformulations for DRCC problems under both sets. Especially, for the Wasserstein ambiguity set, we use the right-hand side (RHS) uncertainty to derive a more compact MILP reformulation than the commonly known MILP reformulations with big-M constants. All the results also apply to general individual chance constraints with RHS uncertainty. Furthermore, we propose an adjustable chance-constrained variant to achieve tradeoff between the operational risk and costs. We derive MILP reformulations under the Wasserstein ambiguity set and second-order conic programming (SOCP) reformulations under the moment-based set. Using real-world data, we conduct computational studies to demonstrate the efficiency of the solution approaches and the effectiveness of the solutions. Summary of Contribution: The problem studied in this paper is motivated by a building load control problem that uses the aggregation of heating, ventilation, and air conditioning (HVAC) loads as flexible reserves to absorb uncertain solar photovoltaic (PV) generation. The problem is formulated as distributionally robust chance-constrained (DRCC) programs with right-hand side (RHS) uncertainty. In addition, we propose a risk-adjustable variant of the DRCC programs, where the risk level, instead of being predetermined, is treated as a decision variable. The paper aims to provide tractable reformulations and solution algorithms for both the (general) DRCC and the (general) adjustable DRCC models with RHS uncertainty.

97 MATHEMATICS AND COMPUTING↗

Network-Cognizant Model Reduction of Grid-Tied Three-Phase Inverters

Power-electronics inverters are expected to satisfy a significant fraction of system load in next-generation power networks with the growing integration of renewable resources and flexible loads. Typical dynamical models for grid-tied inverters are nonlinear and composed of a large number of states; therefore it is impractical to study systems with many inverters when their full dynamics are retained. In our previous work, we have shown that a system of parallel-connected grid-tied three-phase inverters can be modeled as one aggregated inverter unit with the same structure and state-space dimension as any individual inverter in the system. Here, we extend this result to networks with arbitrary topologies by leveraging a classical aggregation method for coherent synchronous generators in transmission networks, and a linear approximation of the AC power-flow equations to ease computational burden. Numerical simulation results for a prototypical distribution feeder demonstrate the accuracy and computational benefits of the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Feasibility Study for Disposal Control Rod Assemblies Using UNF-ST&DARDS As-Loaded Zion Dual Purpose Cask Models

This report documents an initial evaluation to support future use of disposal control rod assemblies (DCRAs) for post-closure criticality control in dual purpose canisters (DPCs). The work described herein is an extension of previous efforts performed by Walker using inputs generated by the Used Nuclear Fuel-Storage, Transportation & Disposal Analysis Resource and Data System (UNFST&DARDS) for the Zion site DPCs with as-loaded isotopic compositions. The results of this analysis demonstrate that there are multiple pathways to using DCRA for post-closure criticality control. Various configurations of DCRA material, diameter, number of rods per DCRA, and number and location of DCRAs within a DPC were shown to be effective in varying degrees for the set of DPCs analyzed by Walker. Because of the variations in DPC as-loaded isotopic compositions considered in an array of DCRA parametric sweeps, it can be concluded that a DPC-specific methodology is feasible (i.e., a one-size-fits-all approach may not be needed). Instead, the utility program created for this work can be expanded to develop capabilities to provide DPC-specific DCRA arrangements to limit cost and weight and to allow for operational considerations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗