At least 469 records · Page 26

Interference Fit Life Factors for Roller Bearings

The effect of hoop stresses in reducing cylindrical roller bearing fatigue life was determined for various classes of inner ring interference fit. Calculations were performed for up to seven interference fit classes for each of ten bearing sizes. Each fit was taken at tightest, average and loosest values within the fit class for RBEC-5 tolerance, thus requiring 486 separate analyses. The hoop stresses were superimposed on the Hertzian principal stresses created by the applied radial load to calculate roller bearing fatigue life. The method was developed through a series of equations to calculate the life reduction for cylindrical roller bearings based on interference fit. All calculated lives are for zero initial bearing internal clearance. Any reduction in bearing clearance due to interference fit was compensated by increasing the initial (unmounted) clearance. Results are presented as tables and charts of life factors for bearings with light, moderate and heavy loads and interference fits ranging from extremely light to extremely heavy and for bearing accuracy class RBEC 5 (ISO class 5). Interference fits on the inner bearing ring of a cylindrical roller bearing can significantly reduce bearing fatigue life. In general, life factors are smaller (lower life) for bearings running under light load where the unfactored life is highest. The various bearing series within a particular bore size had almost identical interference fit life factors for a particular fit. The tightest fit at the high end of the RBEC-5 tolerance band defined in ANSI/ABMA shaft fit tables produces a life factor of approximately 0.40 for an inner-race maximum Hertz stress of 1200 MPa (175 ksi) and a life factor of 0.60 for an inner-race maximum Hertz stress of 2200 MPa (320 ksi). Interference fits also impact the maximum Hertz stress-life relation.

Oswald, Fred B.↗

Interference-Fit Life Factors for Roller Bearings

The effect of hoop stresses in reducing cylindrical roller bearing fatigue life was determined for various classes of inner-ring interference fit. Calculations were performed for up to 7 fit classes for each of 10 bearing sizes. The hoop stresses were superimposed on the Hertzian principal stresses created by the applied radial load to calculate roller bearing fatigue life. A method was developed through a series of equations to calculate the life reduction for cylindrical roller bearings. All calculated lives are for zero initial internal clearance. Any reduction in bearing clearance due to interference fit would be compensated by increasing the initial (unmounted) clearance. Results are presented as tables and charts of life factors for bearings with light, moderate, and heavy loads and interference fits ranging from extremely light to extremely heavy for bearing accuracy class RBEC-5 (ISO class 5). Interference fits on the inner ring of a cylindrical roller bearing can significantly reduce bearing fatigue life. In general, life factors are smaller (lower life) for bearings running under light load where the unfactored life is highest. The various bearing series within a particular bore size had almost identical interference-fit life factors for a particular fit. The tightest fit at the high end of the tolerance band produces a life factor of approximately 0.40 for an inner-race maximum Hertz stress of 1200 MPa (175 ksi) and a life factor of 0.60 for an inner-race maximum Hertz stress of 2200 MPa (320 ksi). Interference fits also impact the maximum Hertz stress-life relation.

Oswald, Fred B.↗

Residual Gas in Closed Systems. III: Development and Reduction of Gases Generated by Source Materials

The amounts and composition of residual gases formed in sealed ampoules loaded with different sources (elements and II-VI and IV-VI compounds) after consecutive annealings were investigated. A given source was subjected to a series of heat treatments, with intermediate measurements and removal of the gas accumulated in the system. The results of these experiments are discussed in terms of the underlying thermochemical and kinetic phenomena and practical limitations of reducing the amount of residual gases in sealed ampoules.

Palosz, W.↗

Experiment K307: Vertebral body strength of rat spinal columns

The effects of space flight on vertebral body bone strength excised were investigated. Comparative biomechanical investigations of vertebral body strength for flight, synchronous, and vivarium rats following spacecraft recovery (R+0), at R+6 and R+29 days post flight recovery are presented. Statistical analyses are presented for the mechanical properties of stiffness, ultimate load, displacement to ultimate load, and energy to ultimate load. At R+0 all of the above properties show that the vertebral body exhibits an increasing susceptibility to fracture. The reduction of bone strength is inhomogeneous and dependent on vertebral level. The R+6 recovery data was inconclusive since it varied above and below the R+0 data. At R+29 ultimate load values showed a statistically significant increase in bone strength approaching that of the vivarium or control group.

Kazarian, L. E.↗

The Use of Doublers in Delamination Toughness Testing

In this paper, the data reduction equations for common delamination toughness tests are rederived for use with specimens which have bonded doublers. The common toughness tests considered here are the double cantilever beam (DCB) for mode I toughness; the end notch flexure (3ENF) and 4 point ENF (4ENF) for mode II toughness; and the mixed mode bending (MMB) test for testing under combined mode I and mode II loading. Because the addition of the doublers changes the bending stiffness of the specimens, these data reduction equations may need to be corrected. Doublers were added to the delamination test specimens to solve a premature failure problem. Delamination toughness is normally tested using a beam with an imbedded insert so that one end of the specimen is split into two arms. If the specimen is too thin, or if the toughness of the material is too high, an arm of the specimen may fail in bending before the delamination grows. When this occurs, the toughness of the material cannot be determined. To delay the bending failure so that delamination growth occurs, doubler plates were bonded to both top and bottom surfaces of the specimen. A doubler parameter, beta, which describes how much the use of doubler plates changed the ratio of full thickness to delaminated bending stiffnesses, was defined. When changes to the data reduction equations were required, the changes were minor when written in terms of the beta parameter. The doubler plate technique was demonstrated by measuring the mixed-mode fracture toughness of a carbon-carbon composite using test specimens which would otherwise have failed before delamination growth occurred. The doubler plate technique may solve several problems that can be encountered when testing delamination fracture toughness.

Reeder, James R.↗

Design Space Exploration of Pericyclic Transmission with Counterbalance and Bearing Load Analysis

The pericyclic transmission provides the opportunity to vastly impact transmission design in rotorcraft due to its ability to provide exceedingly high reduction ratios in a single stage that would normally require multiple gear stages to produce. This could lead to lighter transmissions with fewer components, increased range, reliability, efficiency, speed and decreased cost to maintain. While many previous studies have focused upon the gearing within the pericyclic transmission, this work focused on what influences pericyclic geometry, and how changes in geometry impacts bearing loads. Specifically the loading of bearings that must deliver power from the input shaft to the nutating and rotating gears of the system were of primary concern. A comprehensive look at dynamic loads generated by nutating bodies was performed. Methods to address these dynamic loads via application of counterbalances and deviation from conventional pericyclic transmission designs were utilized to negate the dynamic moment of concern. Finally a static solver was used to determine the bearing loads with updated component geometries and mass moment of inertias that included the required counterbalances.

Pericyclic↗

Design Space Exploration of Pericyclic Transmission with Counterbalance and Bearing Load Analysis

The pericyclic transmission provides the opportunity to vastly impact transmission design in rotorcraft due to its ability to provide exceedingly high reduction ratios in a single stage that would normally require multiple gear stages to produce. This could lead to lighter transmissions with fewer components, increased range, reliability, efficiency, speed and decreased cost to maintain. While many previous studies have focused upon the gearing within the pericyclic transmission, this work focused on what influences pericyclic geometry, and how changes in geometry impacts bearing loads. Specifically the loading of bearings that must deliver power from the input shaft to the nutating and rotating gears of the system were of primary concern. A comprehensive look at dynamic loads generated by nutating bodies was performed. Methods to address these dynamic loads via application of counterbalances and deviation from conventional pericyclic transmission designs were utilized to negate the dynamic moment of concern. Finally a static solver was used to determine the bearing loads with updated component geometries and mass moment of inertias that included the required counterbalances.

Pericyclic↗

Dynamically Tuned Blade Pitch Links for Vibration Reduction

A passive vibration reduction device in which the conventional main rotor blade pitch link is replaced by a spring/damper element is investigated using a comprehensive rotorcraft analysis code. A case study is conducted for a modern articulated helicopter main rotor. Correlation of vibratory pitch link loads with wind tunnel test data is satisfactory for lower harmonics. Inclusion of unsteady aerodynamics had little effect on the correlation. In the absence of pushrod damping, reduction in pushrod stiffness from the baseline value had an adverse effect on vibratory hub loads in forward flight. However, pushrod damping in combination with reduced pushrod stiffness resulted in modest improvements in fixed and rotating system hub loads.

Milgram, Judah↗

Effect of at-the-source noise reduction on performance and weights of a tilt-rotor aircraft

Reduction of far-field acoustic signature through modification of basic design parameters (tip speed, number of blades, disc loading and rotor blade area) was examined, using a tilt-rotor flight research aircraft as a baseline configuration. Of those design parameters, tip speed appeared as the most important. Next, preliminary design of two aircraft was performed, postulating the following reduction of noise level from that of the baseline machine, at 500 feet from the spot of OGE hover. In one aircraft, the PNL was lowered by 10 PNdB and in the other, OASPL decreased by 10 dB. The resulting weight and performance penalties were examined. Then, PNL and EPNL aspects of terminal operation were compared for the baseline and quieter aircraft.

Gibs, J.↗

Effect of reducing rotor blade inlet diameter on the performance of a 11.66-Centimeter radial-inflow turbine

The effect of increased rotor blade loading on turbine performance was investigated by reducing rotor blade inlet diameter. The reduction was made in four stages. Each modification was tested with the same stator using cold air as the working fluid. Results are presented in terms of equivalent mass flow and efficiency at equivalent design rotative speed and over a range of pressure ratios. Internal flow characteristics are shown in terms of stator exit static pressure and the radial variation of local loss and rotor-exit flow angle with radius ratio. Included are velocity diagrams calculated from the experimental results.

Kofskey, M. G.↗

Analytical and experimental study of high phase order induction motors

Induction motors having more than three phases were investigated to determine their suitability for electric vehicle applications. The objective was to have a motor with a current rating lower than that of a three-phase motor. The name chosen for these is high phase order (HPO) motors. Motors having six phases and nine phases were given the most attention. It was found that HPO motors are quite suitable for electric vehicles, and for many other applications as well. They have characteristics which are as good as or better than three-phase motors for practically all applications where polyphase induction motors are appropriate. Some of the analysis methods are presented, and several of the equivalent circuits which facilitate the determination of harmonic currents and losses, or currents with unbalanced sources, are included. The sometimes large stator currents due to harmonics in the source voltages are pointed out. Filters which can limit these currents were developed. An analysis and description of these filters is included. Experimental results which confirm and illustrate much of the theory are also included. These include locked rotor test results and full-load performance with an open phase. Also shown are oscillograms which display the reduction in harmonic currents when a filter is used with the experimental motor supplied by a non-sinusoidal source.

Klingshirn, Eugene A.↗

Short Turnbuckle

Offset turnbuckle provides overlap between end fasteners, with consequent reduction in length. Tighten by turning nut. Offset prevents eyebolts from loosening when load applied.

Macmartin, Malcolm J.↗

Miniaturized Wilkinson Power Dividers Utilizing Capacitive Loading

This letter reports the miniaturization of a planar Wilkinson power divider by capacitive loading of the quarter wave transmission lines employed in conventional Wilkinson power dividers. Reduction of the transmission line segments from lambda/4 to between lambda/5 and lambda/12 are reported here. The input and output lines at the three ports and the lines comprising the divider itself are coplanar waveguide (CPW) and asymmetric coplanar stripline (ACPS), respectively. The 10 GHZ power dividers are fabricated on high resistivity silicon (HRS) and alumina wafers. These miniaturized dividers are 74% smaller than conventional Wilkinson power dividers, and have a return loss better than +30 dB and an insertion loss less than 0.55 dB. Design equations and a discussion about the effect of parasitic reactance on the isolation are presented for the first time.

Scardelletti, Maximilian C.↗

Improved load distribution in parallel sparse Cholesky factorization

Compared to the customary column-oriented approaches, block-oriented, distributed-memory sparse Cholesky factorization benefits from an asymptotic reduction in interprocessor communication volume and an asymptotic increase in the amount of concurrency that is exposed in the problem. Unfortunately, block-oriented approaches (specifically, the block fan-out method) have suffered from poor balance of the computational load. As a result, achieved performance can be quite low. This paper investigates the reasons for this load imbalance and proposes simple block mapping heuristics that dramatically improve it. The result is a roughly 20% increase in realized parallel factorization performance, as demonstrated by performance results from an Intel Paragon system. We have achieved performance of nearly 3.2 billion floating point operations per second with this technique on a 196-node Paragon system.

Rothberg, Edward↗

Frequency and load ratio effects on critical strain energy release rate Gc thresholds of graphite/epoxy composites

Graphite/epoxy composite laminates of T300/BP907 and AS6/HST-7 were axial-tension fatigue tested. Tests were conducted at 5 and 10 Hz, and at loading ratios of R = 0.1 and R = 0.5. Edge delamination was monitored as a function of number of fatigue cycles by monitoring stiffness reduction during fatigue testing. Delamination was confirmed and documented using dye-enhanced X-ray and optical photography. Critical strain energy release rates were then calculated. The composites delaminated readily, with loading ratio having a significant influence. Frequency effects were negligible.

Adams, Donald F.↗

Progress Toward the Critical Design of the Superconducting Rotor for NASA's 1.4 MW High-Efficiency Electric Machine

NASA Glenn Research Center is developing a 1.4 MW high-efficiency electric machine for future electrified aircraft to reduce energy consumption, emissions, and noise. This wound-field, synchronous machine employs a self-cooled, superconducting rotor to achieve excellent specific power and efficiency. This paper presents the progress made over the past year toward a critical design of the superconducting rotor, including refined analysis and risk reduction testing on prototype superconducting coils. A 3D finite element model of the rotor is developed to simulate the combined loading imposed by the initial cool down of the rotor from room temperature to cryogenic temperature and the subsequent rotation of the rotor up to the design speed. The model is evaluated to better predict the stress state in the critical components and the reduction in physical gap between the stator and rotor due to the resulting radial deflections. This model includes an enhanced model of the superconducting coil that considers the coil as an assembly of four individual coil layers. An improved coil fabrication process is described in detail. Two sub-scale test coils are fabricated and then tested under repeated thermal cycling between room temperature and liquid nitrogen temperature (77 K). It is demonstrated that the proposed coil fabrication procedure can produce no-insulation, high temperature superconducting coils that can survive several thermal cycles without apparent degradation.

electric machines↗

Progress Toward the Critical Design of the Superconducting Rotor for NASA's 1.4 MW High Efficiency Electric Machine

NASA Glenn Research Center is developing a 1.4 MW high-efficiency electric machine for future electrified aircraft to reduce energy consumption, emissions, and noise. This wound-field, synchronous machine employs a self-cooled, superconducting rotor to achieve excellent specific power and efficiency. This paper presents the progress made over the past year toward a critical design of the superconducting rotor, including refined analysis and risk reduction testing on prototype superconducting coils. A 3D finite element model of the rotor is developed to simulate the combined loading imposed by the initial cool down of the rotor from room temperature to cryogenic temperature and the subsequent rotation of the rotor up to the design speed. The model is evaluated to better predict the stress state in the critical components and the reduction in physical gap between the stator and rotor due to the resulting radial deflections. This model includes an enhanced model of the superconducting coil that considers the coil as an assembly of four individual coil layers. An improved coil fabrication process is described in detail. Two sub-scale test coils are fabricated and then tested under repeated thermal cycling between room temperature and liquid nitrogen temperature (77 K). It is demonstrated that the proposed coil fabrication procedure can produce no-insulation, high temperature superconducting coils that can survive several thermal cycles without apparent degradation.

Scheidler, Justin↗

Coupled rotor-flexible fuselage vibration reduction using open loop higher harmonic control

A fundamental study of vibration prediction and vibration reduction in helicopters using active controls was performed. The nonlinear equations of motion for a coupled rotor/flexible fuselage system have been derived using computer algebra on a special purpose symbolic computer facility. The trim state and vibratory response of the helicopter are obtained in a single pass by applying the harmonic balance technique and simultaneously satisfying the trim and the vibratory response of the helicopter for all rotor and fuselage degrees of freedom. The influence of the fuselage flexibility on the vibratory response is studied. It is shown that the conventional single frequency higher harmonic control is capable of reducing either the hub loads or only the fuselage vibrations but not both simultaneously. It is demonstrated that for simultaneous reduction of hub shears and fuselae vibrations a new scheme called multiple higher harmonic control is required.

Papavassiliou, I.↗