Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “load power”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Bipolar Membrane Electrodialyzers as Flexible Demand Response Resources: Co-Optimization of Cost Savings and Product Formation

Bipolar membrane electro dialyzers (BPMED) are widely used for chemical production and processing, including in the emerging ocean alkalinity enhancement (OAE) industry. In this paper, we explore the potential of BPMED devices as flexible electrochemical loads within power system operations. Using a multi-objective optimization framework, we evaluate BPMED operation across 24-hour and monthly horizons to examine how dispatch strategies respond to electricity price and grid conditions. Simulation results show that altering the relative weights of the choices in the objective function strongly shape the operating patterns, with cost-focused strategies that suppress the operation during peak prices. Furthermore, we propose alternative formulations that optimize operations to achieve both cost savings and alignment with periods of lower grid-side carbon intensity (CI), as low grid-side CI is key to maximize OAE efficiency. Additionally, a detailed sensitivity analysis highlights the importance of device properties, where low area-specific resistance (ASR) of membrane and high current efficiency (CE) are observed to jointly unlock cost-effective operation. However, even modest shunt efficiency losses are observed to erode performance and decrease system value. Importantly, the analysis demonstrates that BPMED can serve as a controllable and flexible demand response resource, shifting load to support multiple grid-side objectives, including (but not limited to) renewable integration, alleviate peak demand, and provide co-benefits for system reliability. These findings underscore BPMED’s dual role as a process technology and a grid-supporting asset, pointing to promising pathways for operational optimization of multiple objectives.

Bhattacharya, Saptarshi (ORCID:0000000308902060)↗

Solving Unit Commitment Problems with Demand Responsive Loads

This work focuses on using variations of the Frank-Wolfe (FW) algorithm for solving unit commitment problems with high volumes of demand responsive loads on the power grid. We present a formulation of the unit commitment problem with demand responsive loads. We then show through reformulation and relaxations of the problem that variations of the Frank-Wolfe algorithm can be used to determine the time series decisions for the demand responsive loads. We show through computational experiments on the IEEE Reliability Test System that the timeseries of demand responsive load decisions obtained through our approach are near optimal and describe how large-scale parallel implementations of our approach can be highly computationally efficient.

demand response↗

Application of Out-of-Plane Warping to Control Rotor Blade Twist

The goal of this ongoing study is to develop and demonstrate the feasibility of a blade actuation system to dynamically change the twist, and/or the camber, of an airfoil section and, consequently, alter the in-flight aerodynamic loading on the blade for efficient flight control. The required analytical and finite element tools are under development to enable an accurate and comprehensive aeroelastic assessment of the current Full-Blade Warping and 3D Warping Actuated Trailing Edge Flap concepts. The feasibility of the current concepts for swashplateless rotors and higher harmonic blade control is also being investigated. In particular, the aim is to complete the following objectives, some of which have been completed (as noted below) and others that are currently ongoing: i) Develop a Vlasov finite element model and validate against the ABAQUS shell models (completed). ii) Implement the 3D warping actuation concept within the comprehensive analysis code DYMORE. iii) Perform preliminary aeroelastic simulations of blades using DYMORE with 3D warping actuation: a) Investigate the blade behavior under 1 per/rev actuation. Determine whether sufficient twist can be generated and sustained to achieve primary blade control. b) Investigate the behavior of a trailing edge flap configuration under higher harmonic excitations. Determine how much twist can be obtained at the harmonics 2-5 per/rev. iv) Determine actuator specifications such as the power required, load and displacements, and identify the stress and strain distributions in the actuated blades. In general, the completion of Item ii) above will give an additional research capability in rotorcraft dynamics analyses, i.e., the capability to calculate the rotor blade twist due to warping, something that is not currently available in any of the existing comprehensive rotorcraft analyses.

VanWeddingen, Yannick↗

Electromagnetic Transient Modeling of Large Data Centers for Grid-Level Studies: Beta Release

The magnitude and complexity of electricity usage patterns from large data centers are having significant impacts on the operation and dynamics of the power grid; grid operators and planners require a range of specialized data center models to properly evaluate these impacts and specify technical solutions as needed. Towards addressing this need, Pacific Northwest National Laboratory (PNNL) has developed a library of electromagnetic transient (EMT) models for grid-level studies of data centers called the data center model library (DML). This report describes how the DML was created and how it may properly be used. This report details the DML’s beta release, completed in July 2026. This is a revision and expansion of the alpha release, which was made available in January 2026 The models present in the DML are generic models; subject matter expertise and additional technical data are needed to modify these models before they can represent any real data center. However, they will significantly reduce the level of effort required to develop site-specific models and can serve as a common starting point to guide industry towards a more refined consensus. Most of the models within DML are dedicated to representing the power electronics interfaces commonly used in modern data centers, such as double-conversion uninterruptible power supplies and single-phase power factor correction converters. These models are intended for use in grid-level studies and are a simplified aggregation of many small components. That said, background material on the physical and electrical design of large data centers is provided as companion material so that users can be aware of many of the details which have been omitted or streamlined as a matter of practical necessity. Additionally, guidance on the application of EMT analysis for data center interconnection studies is provided, which aids users in identifying when the DML is necessary and what sort of additional model development may be necessary for conducting real-world studies.

electromagnetic transients↗

Secondary Networks and Protection: Implications for DER and Microgrid Interconnection

Secondary networks are used to supply power to loads that require very high reliability and are in use around the world, particularly in dense urban downtown areas. The protection of secondary network systems poses unique challenges. The addition of distributed energy resources (DERs) to secondary networks can compound these challenges, and deployment of microgrids on secondary networks will create a new set of challenges and opportunities. This report discusses secondary networks and their protection, the challenges associated with interconnecting DERs to a secondary network, issues expected to be associated with creating microgrids on secondary networks, standards that deal with these challenges and issues, and suggestions for research and development foci that would yield new means for addressing these challenges.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Techno-Economic Analysis and Optimization of a Compressed-Air Energy Storage System Integrated with a Natural Gas Combined-Cycle Plant

To address the rising electricity demand and greenhouse gas concentration in the environment, considerable effort is being carried out across the globe on installing and operating renewable energy sources. However, the renewable energy production is affected by diurnal and seasonal variability. To ensure that the electric grid remains reliable and resilient even for the high penetration of renewables into the grid, various types of energy storage systems are being investigated. In this paper, a compressed-air energy storage (CAES) system integrated with a natural gas combined-cycle (NGCC) power plant is investigated where air is extracted from the gas turbine compressor or injected back into the gas turbine combustor when it is optimal to do so. First-principles dynamic models of the NGCC plant and CAES are developed along with the development of an economic model. The dynamic optimization of the integrated system is undertaken in the Python/Pyomo platform for maximizing the net present value (NPV). NPV optimization is undertaken for 14 regions/cases considering year-long locational marginal price (LMP) data with a 1 h interval. Design variables such as the storage capacity and storage pressure, as well as the operating variables such as the power plant load, air injection rate, and air extraction rate, are optimized. Results show that the integrated CAES system has a higher NPV than the NGCC-only system for all 14 regions, thus indicating the potential deployment of the integrated system under the assumption of the availability of caverns in close proximity to the NGCC plant. The levelized cost of storage is found to be in the range of 136–145 $/MWh. Roundtrip efficiency is found to be between 74.6–82.5%. A sensitivity study with respect to LMP shows that the LMP profile has a significant impact on the extent of air injection/extraction while capital expenditure reduction has a negligible effect.

25 ENERGY STORAGE↗

Space Station Freedom power supply commonality via modular design

At mature operations, Space Station Freedom will need more than 2000 power supplies to feed housekeeping and user loads. Advanced technology power supplies from 20 to 250 W have been hybridized for terrestrial, aerospace, and industry applications in compact, efficient, reliable, lightweight packages compatible with electromagnetic interference requirements. The use of these hybridized packages as modules, either singly or in parallel, to satisfy the wide range of user power supply needs for all elements of the station is proposed. Proposed characteristics for the power supplies include common mechanical packaging, digital control, self-protection, high efficiency at full and partial loads, synchronization capability to reduce electromagnetic interference, redundancy, and soft-start capability. The inherent reliability is improved compared with conventional discrete component power supplies because the hybrid circuits use high-reliability components such as ceramic capacitors. Reliability is further improved over conventional supplies because the hybrid packages, which may be treated as a single part, reduce the parts count in the power supply.

Krauthamer, S.↗

Harmonic cancellation within AC low voltage distribution for a realistic office environment

An increase of non-linear loads, primarily from power electronics, has substantially increased current harmonics in commercial buildings, which contributes to decreased transformer efficiency / lifespan and poor power quality. This study uses recorded power consumption data from common miscellaneous electric loads (MELs) seen in offices, combined with detailed characterizations of example MELs, to simulate harmonic cancellation within building circuits. Typically, harmonic cancellation studies assume that AC converters operate across their rated power range. However, this study finds that common MELs operate below 40% of rated power the majority of the time when not quiescent; 89% of sampled devices never operated above 60% of rated power. Simulations using these more realistic power levels indicate current-harmonic cancellation (3rd to 13th harmonic) is significantly lower than that predicted when using full-range power assumptions, resulting in minor errors for low-order harmonics and larger errors for higher order harmonics. Furthermore, increased MELs load diversity increases harmonic cancellation, but insufficiently to eliminate errors. In contrast, blending lighting loads with MELs on the secondaries of distribution transformers improves harmonic cancellation to near those predicted by traditional methods. These results indicate that realistic power levels, as well as better characterization of harmonics from typical MELs, should be used to estimate harmonic cancellation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Wind turbine response in waked inflow: A modelling benchmark against full-scale measurements

Predicting the power and loads of wind turbines in waked inflow conditions still presents a major modelling challenge. It requires the accurate modelling of the atmospheric flow conditions, wakes of upstream turbines and the response of the turbine of interest. Rigorous validations of model frameworks against measurements of utility-scale wind turbines in such scenarios remain limited to date. In this study, six models of different fidelity are compared against measurements from the DanAero experiment. The two benchmark cases feature a full-wake and partial-wake scenario, respectively. The simulations are compared against local pressure forces and inflow velocities measured on several blade sections of the downstream turbine, as well as met mast measurements and standard SCADA data. Regardless of the model fidelity, reasonable agreements are found in terms of the wake characteristics and turbine response. For instance, the azimuth variation of the mean aerodynamic forces acting on the blade was captured with a mean relative error of 15-20%. Additionally, while various model-specific deficiencies could be identified, the study highlights the need for further full-scale measurement campaigns with even more extensive instrumentation. Furthermore, it is concluded that validations should not be limited to integrated and/or time-averaged quantities that conceal characteristic spatial or temporal variations.

17 WIND ENERGY↗

Ultrasonic measurement of temperature distributions in extreme environments: Electrical power plants testing in utility-scale steam generators

Thermal heterogeneities within energy conversion and storage, material processing, nuclear processes, aerospace, and military applications are often inaccessible to characterization by insertion sensors. When sensor deployment is possible, conventional pointwise temperature probes quickly degrade when inserted into harsh environments typical of such processes. We developed spatially-resolved ultrasonic thermometry to noninvasively measure the spatial distributions of thermal properties in such applications, even when sizable thermal gradients are present. Our method divides the path of ultrasonic propagation into segments bound by echogenic features, which create echoes in pulse-echo mode, encoding the information about interior temperature distributions. We use the acquired ultrasonic responses to estimate the internal temperature distributions by solving an inverse problem or concatenating segmental estimates. This work describes the implementation and industrial testing of the developed method at a coal-fired electrical power generation plant. We inserted an echogenically segmented Inconel 625 waveguide into the combustion zone of the utility-scale boiler and continuously acquired ultrasonic data while keeping sensitive components away from the damaging combustion environment. The accuracy of the time-dependent temperature distributions reconstructed from the ultrasonic measurements was comparable to that of thermocouples. The resiliency of ultrasonic thermometry to harsh combustion conditions was far superior to conventional insertion sensors. The measurements obtained during plant operation captured daily steam generation cycles in response to changing customer demand and intermittent contributions of renewable power sources to the power grid. These measurements have revealed new insights into the relationship between the dynamic power generation load and the conditions inside the steam generator. As a result, the successful industrial testing of spatially-resolved ultrasonic thermometry in solids indicates that the developed technology has matured to become an attractive alternative to conventional sensing in solving challenging problems of long-term thermal characterizations in extreme environments.

42 ENGINEERING↗

Techno-Economic Analysis of Repurposing Natural Gas Transmission Pipeline Networks to Accommodate Hydrogen Blends

Blending hydrogen into natural gas infrastructure could supplement natural gas supply and increase resilience for applications such as ammonia production, peaking and load-following power plants, and heating. The United States has an extensive network of natural gas pipelines, but the feasibility of employing this infrastructure to transport hydrogen is unclear. We analyze the costs associated with repurposing three distinct natural gas transmission pipelines in different locations within the United States to carry blends of hydrogen up to 100% via three different pipeline network modification methods and compare against the cost of building a new dedicated hydrogen pipeline. We conduct a sensitivity analysis on the hoop stress limit of the existing pipe, techno-economic parameters, emissions, and relative capacity. The results show that the capital costs required to upgrade a pipeline can vary from tens of millions to billions of dollars depending on the length and capacity of the existing pipeline section, whether the existing pipeline already operates at or below its maximum allowable operating pressure, whether future demand is expected to increase or decrease, the network modification method selected, and pipe material costs. The delivered cost of energy to end users is impacted less by the levelized cost of transporting hydrogen blends than by the cost of the natural gas and hydrogen fuels being transported. The emissions impact of blending hydrogen into natural gas transmission networks scales proportionally with the amount of energy displaced with low-emission hydrogen (such as from natural gas with carbon capture and sequestration or electrolysis powered by nuclear, renewable, or geothermal electricity), therefore low blend ratios (e.g., < 20% vol. hydrogen) will result in low emissions impacts. Factors such as permitting and right-of-way costs, the proximity of the pipeline to hydrogen demand and production, and the compatibility of and/or retrofitting costs of end-use gas-fueled technologies will likely be greater drivers in determining whether converting a particular natural gas pipeline to carry hydrogen makes economic sense.

08 HYDROGEN↗

Ion temperature anisotropy in the tokamak scrape-off layer

Understanding tokamak exhaust-power heat loads on divertor plates depends critically on having a realistic model of the scrape-off layer (SOL) plasma. The Braginskii fluid model is often solved to understand the SOL plasma behavior. This model is based on the collisional limit for transport along the magnetic field B → . The ions and electron gyrofrequencies are assumed to be much larger than the Coulomb collision frequencies, which are nonetheless, sufficiently large to yield common parallel and perpendicular temperatures for each species, i.e. the temperatures are assumed to be isotropic. Additionally, in certain circumstances such as encountered for the tokamak H-mode, the ion temperature can be quite anisotropic. In this work, the anisotropy effects are implemented in the two-dimensional (2D) transport code UEDGE. Various geometries (1D slab, 2D slab and a toroidal tokamak geometry) are used to study the 2D structure of ion temperature anisotropy and its effects on plasma transport in detail. Results show that the effects of ion temperature anisotropy on the plasma parallel transport are substantial near the magnetic X-point, which leads to different steady state density profiles in the divertor regions. The extra mirror force introduced by ion temperature anisotropy can be one of the main forces contributing to the plasma flow in the SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Benchmarks for Model Validation based on LiDAR Wake Measurements

Technology development and design decisions in wind energy are often based on results from simulations performed for individual wind turbines or entire wind plants. It is therefore critical to ensure that the models being used for research and industry applications in wind energy be thoroughly validated against measurements. A full-system validation of wind plant simulations must consider the atmospheric inflow, the response of the wind turbines, and their wakes. This task is complicated by the lack of freely available, quality-controlled, high-quality measurements. Here, such measurements are used to offer a validation exercise that can be used to assess the accuracy of models of any fidelity level. When it comes to real-world measurements, the dataset considered herein is simple in terms of terrain but exhibits pronounced diurnal cycles. Instead of a full-scale wind plant, we consider an individual research-scale, utility wind turbine instrumented for power and loads measurements. Three benchmarks are defined, with increasing levels of complexity: near neutral, slightly unstable, and very stable atmospheric stratification. Through comparisons between observations and simulations, the benchmarks provide complementary information about the model performance and its ability to reproduce mean and dynamic wake characteristics. This article describes the measurements and methodology used to define these benchmarks and provides the information required to perform simulations and conduct the model-measurement comparison. The objective is to provide a robust wake model validation exercise open to anyone, which will serve to minimize uncertainty in model validation practices related to varying methodologies across simulation tools and users.

17 WIND ENERGY↗

Do ambient shear and thermal stratification impact wind turbine tip-vortex breakdown?

Modern wind turbines experience uneven inflow conditions across the rotor, due to the ambient flow’s shear and thermal stratification. Such conditions alter the shape and length of turbine wakes and thus impact the loads and power generation of downstream turbines. To this end, understanding the spatial evolution of the individual wakes under different atmospheric conditions is key to controlling and optimising turbine arrays. With this numerical study we aim to obtain a better understanding of the fundamental physics governing the near-wake dynamics of wind turbines under shear and thermal stability, by examining their tip-vortex breakup mechanisms. Our approach considers scale-resolving simulations of a single turbine wake under a linear shear profile as well as the application of harmonic tip perturbations to trigger flow instabilities. For the subsequent analysis we use the proper orthogonal decomposition (POD) method to extract coherent structures from the flow, and we also calculate mean kinetic energy fluxes to quantify each coherent structure’s contribution to wake recovery. The wake’s helical spiral is found to hinder wake recovery for all studied ambient flow conditions, whereas the mutual inductance instability has positive MKE flux leading to an enhanced wake recovery. Finally, the ambient shear has the largest impact on the local MKE flux with respect to downstream location by changing the shape of the curve and location of extrema, whereas thermal stratification has only a minimal impact on the magnitude of the near-wake local MKE flux distribution.

17 WIND ENERGY↗

Direct Envelope Modeling of Load-Resonant Inverter for Wireless Power Transfer Applications

This paper presents the application of direct envelope modeling technique to primary side LCC tuned resonant wireless power transfer system. The method adapted here decomposes the HF resonant inverter output to a fundamental component and two dominant sidebands. The small-signal dutycycle-to-primary-coil-current-envelope transfer function of a primary side LCC tuned WPT system is then derived as the summation of the responses to the fundamental and the sideband components. The theoretical and simulation results are in good agreement indicating the validity of the approach to be applied to WPT systems.

Galigekere, Veda Prakash↗

Hierarchical Model-Free Transactive Control of Residential Building Loads: An Actual Deployment

The transformation of electricity systems into more sustainable configurations brought some new challenges. The uncertain, intermittent, and variable nature of renewable energy sources require a significant amount of load demand flexibility, in which grid-interactive buildings (GEBs) are important flexible assets for electricity systems. In this regard, many demand response (DR) tools have been developed to harness this demand flexibility. However, such tools are mostly simulation-based or deal with a single load, which may not be sufficient to demonstrate their effectiveness. Towards this end, this paper presents a real-world field implementation and testing of a hierarchical model-free transactive DR control approach on actual GEBs. The control implementation incorporates elements of virtual battery, game theory, and model-free control mechanisms. The proposed approach was tested using a total of five GEBs, each having three zones. The results show that the proposed approach can mostly achieve all intended objectives, including flexibility estimation, peak load reduction, power tracking, and controlling GEBs while maintaining occupants’ comfort.

Amasyali, Kadir↗