Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “liquid chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Extraterrestrial Amino Acids in the C2 Ungrouped Carbonaceous Chondrite Tarda: A Unique Distribution

Introduction: Meteorites provide a record of the chemical processes that occurred in the early solar sys-tem. The delivery of organic matter by carbonaceous chondrites to the early Earth could have been an im-portant source of amino acids and other prebiotic or-ganic molecules required for the emergence of life [1]. To date, 96 amino acids have been named in meteor-ites, most of which are rare or absent in the biosphere [2]. The variability in amino acid concentrations and isomer distributions measured in carbonaceous chon-drites can be explained by differences in parent body chemistry and alteration conditions [3]. In addition, aqueous alteration was likely important in the amplifi-cation of some left-handed amino acids over their right-handed forms (L-excesses up to ~60%) in the Tagish Lake meteorite [3], suggesting that the origin of life on Earth and possibly elsewhere in the solar sys-tem was biased towards L-amino acids. On August 25, 2020, a fireball was witnessed in southern Morocco and the first pieces of the meteorite fall were recovered the following day near the town of Tarda [4]. Thousands of individual fragments were recovered from the strewn field totaling ~4 kg [4]. Based on petrographic observations, bulk mineralogy, and chemical and O-isotopic analyses, Tarda has been classified as a C2 ungrouped carbonaceous chondrite with similarities to Tagish Lake (though more primi-tive), as well as CI, CY, and CR chondrites [4,5]. The fall and rapid recovery of the Tarda stones provide an important opportunity to investigate a C-rich meteorite using the state-of-the-art techniques that will also be used to study the samples returned from asteroids Ryugu and Bennu by the Hayabusa2 and OSIRIS-REx missions, respectively. Here, we report the first amino acid analyses of the Tarda meteorite. The total concentrations, enantio-meric ratios and relative distributions of amino acids were determined using ultrahigh performance liquid chromatography with UV fluorescence and time-of-flight mass spectrometry (LC-FD/ToF-MS) at NASA GSFC. This analytical technique was employed on extracts from two different pre-rain Tarda meteorite fragments and a sample of sand collected from the Tarda fall site for the purpose of assessing potential terrestrial contamination. Bulk H, C, and N elemental and isotopic analyses were also conducted at the Car-negie Institution for Science (CIS) to assist with petro-logic type classification using elemental analysis iso-tope ratio mass spectrometry (EA-IRMS).

D P Glavin↗

The Search for Chiral Asymmetry as a Potential Biosignature in Samples from Mars

The search for evidence of extraterrestrial life in our solar system has been guided by our under-standing of terrestrial biology and its associated biosignatures. The observed homochirality in all life on Earth, that is, the predominance of “left-handed” or L-amino acids and “right-handed” or D-sugars, is a unique property of life that is crucial for molecular recognition, enzymatic function, information storage and structure, and is thought to be a prerequisite for the origin or early evolution of life. Therefore, the detection of L- or D-excesses of chiral amino acids or sugars could be a powerful indicator of extant or extinct life on Mars or other habitable environments in our solar system. However, studies of primitive meteorites have revealed that they contain extraterrestrial amino acids and sugar acids with large enantiomeric excesses (60% and higher) that resulted from non-biological processes [1], complicating the use of chiral asymmetry by itself as a definitive biosignature. The exploration of habitable environments on Mars, including an assessment of the preservation potential for complex organics of either abiotic or biological origin, is an objective of both current and future Mars missions. Now with the unambiguous detection of indigenous organic matter in sedimentary rocks by the Sample Analysis at Mars (SAM) instrument suite on Mars [2-5], NASA’s Curiosity rover has found evidence of the preservation of potential chemical biosignatures in the martian near surface. Although amino acids have not yet been identified by in situ measurements on Mars [5], indigenous achiral amino acids have been identified in one martian meteorite [6]. It is expected that amino acid racemization would be very slow and any chiral or isotopic signatures from an extinct martian biota could be preserved for billions of years, given the extremely cold and dry surface conditions [7]. The ESA/Roscosmos ExoMars mission scheduled for launch next year includes the Rosalind Franklin rover designed to acquire samples from a depth of ~2 m and deliver them to a suite of instruments, including the Mars Organic Molecule Analyzer (MOMA). The MOMA instrument contains a wet chemistry experiment designed specifically for the detection of amino acids and measurement of their enantiomeric compositions [8]. The complexity and limited duration of spaceflight operations, and the known analytical challenges associated with in situ extraction and characterization of trace reduced organic com-pounds in ancient rocks, make it challenging to determine the origins of martian organic matter found to date. Coordinated state-of-the-art laboratory measurements of returned samples from Mars that include spatially resolved chemical, mineralogical, bulk and molecule-specific isotopic, and enantiomeric measurements will be required to firmly establish whether the complex organic matter detected on Mars derives from bio-tic or abiotic processes. Ultimately, Mars Sample Return of rock cores collected by NASA’s Perseverance rover may be our best chance of identifying chemical biosignatures, including any chiral amino acid asymmetry resulting from a past or present martian biota, if one ever existed on Mars. Here we review our current knowledge of the distributions, and enantiomeric and isotopic com-positions of amino acids found in meteorites compared to terrestrial biochemistry. We also propose a set of measurement criteria that should be used to help establish the sources of any amino acids detected in samples returned from Mars using state-of-the-art gas and liquid chromatography mass spectrometry techniques [1].

D P Glavin↗

The Spacecraft Water Impurity Monitor, a Framework for the Next Generation Complete Water Analysis System for Crewed Vehicles Beyond the ISS

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. Eventually, missions to the moon, Mars, and beyond will be equipped with analytical capabilities equaling those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. This paper discusses the challenges presented by exploration requirements and the research and development progress toward the goal of a total water analysis system. For organic analysis, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For inorganic analysis, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

water monitoring↗

Diagnosing Seasonal to Multi-decadal Phytoplankton Group Dynamics in a Highly Productive Coastal Ecosystem

The Santa Barbara Channel, CA (SBC) is a biodiverse marine ecosystem fueled largely by phytoplankton productivity, and the composition of the phytoplankton community influences the magnitude and fates of this productivity. Here, we create a 22-year monthly time series of phytoplankton biomarker pigment concentrations in the SBC by combining 12 years of high performance liquid chromatography phytoplankton pigment concentrations with bio-optical models and 10 additional years of bio-optical observations. The bio-optical models skillfully predict biomarker pigment concentrations representative of five distinct phytoplankton groups (PGs; diatoms, dinoflagellates, chlorophytes, prymnesiophytes, and picophytoplankton) and resolve seasonal responses to the annual upwelling-relaxation cycle for all PGs except the dinoflagellates. Our observations indicate that nanophytoplankton groups respond most rapidly to seasonal upwelling, followed by diatoms, and then by picophytoplankton as the water column stratifies in the summer. A Regional Ocean Modeling System (ROMS) solution is used to relate advection of different source waters to the observed PG dynamics. The ROMS simulation results suggest that, on seasonal time scales, pronounced cross-SBC differences in PG seasonality are related to cross-SBC differences in source waters. El Niño Southern Oscillation events drive interannual variability in the upwelling response of most PGs. On decadal time scales, dinoflagellate blooms are associated with the warm phase of the North Pacific Gyre Oscillation and anomalous advection of Southern California Bight source waters into the SBC. Taken together, our results provide a novel view of phytoplankton community succession in response to seasonal upwelling by considering the dynamics of pico- and nano-phytoplankton and suggest that regional surface ocean advection plays a substantial role in driving phytoplankton composition in the SBC.

Phytoplankton↗

Non-Protein Amino Acids Identified in Carbon-Rich Hayabusa Particles

Amino acid abundances in acid-hydrolyzed hot water extracts of gold foils containing five Category 3 (carbon-rich) Hayabusa particles were studied using liquid chromatography with tandem fluorescence and accurate mass detection. Initial particle analyses using field emission scanning electron microscopy with energy-dispersive X-ray spectrometry indicated that the particles were composed mainly of carbon. Prior to amino acid analysis, infrared and Raman microspectroscopy showed some grains possessed primitive organic carbon. Although trace terrestrial contamination, namely L-protein amino acids, was observed in all Hayabusa extracts, several terrestrially uncommon non-protein amino acids were also identified. Some Hayabusa particles contained racemic (D≈L) mixtures of the non-protein amino acids β-aminoisobutyric acid (β-AIB) and β-amino-n-butyric acid (β-ABA) at low abundances ranging from 0.09 to 0.31 nmol g −1 . Larger abundances of the non-protein amino acid β-alanine (9.2 nmol g −1 , ≈4.5 times greater than background levels) were measured in an extract of three Hayabusa particles. This β-alanine abundance was ≈6 times higher than that measured in an extract of a CM2 Murchison grain processed in parallel. The comparatively high β-alanine abundance is surprising as asteroid Itokawa is similar to amino acid-poor LL ordinary chondrites. Elevated β-alanine abundances and racemic β-AIB and β-ABA in Hayabusa grains suggested these compounds have non-biological and plausibly non-terrestrial origins. These results are the first evidence of plausibly extraterrestrial amino acids in asteroid material from a sample-return mission and demonstrate the capabilities of the analytical protocols used to study asteroid Ryugu and Bennu samples returned by the JAXA Hayabusa2 and NASA OSIRIS-REx missions, respectively.

Eric T. Parker↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Phytoplankton Diversity and Chemotaxonomy in Contrasting North Pacific Ecosystems

Background. Phytoplankton is the base of majority of ocean ecosystems. It is responsible for half of the global primary production, and different phytoplankton taxa have a unique role in global biogeochemical cycles. In addition, phytoplankton abundance and diversity are highly susceptible to climate induced changes, hence monitoring of phytoplankton and its diversity is important and necessary. Methods. Water samples for phytoplankton and photosynthetic pigment analyses were collected in boreal winter 2017, along transect in the North Pacific Subtropical Gyre (NPSG) and the California Current System (CCS). Phytoplankton community was analyzed using light and scanning electron microscopy and photosynthetic pigments by high-performance liquid chromatography. To describe distinct ecosystems, monthly average satellite data of MODIS Aqua Sea Surface temperature and Chlorophyll a concentration, as well as Apparent Visible Wavelength were used. Results. A total of 207 taxa have been determined, mostly comprised of coccolithophores (35.5%), diatoms (25.2%) and dinoflagellates (19.5%) while cryptophytes, phytoflagellates and silicoflagellates were included in the group ``others" (19.8%). Phytoplankton spatial distribution was distinct, indicating variable planktonic dispersal rates and specific adaptation to ecosystems. Dinoflagellates, and nano-scale coccolithophores dominated NPSG, while micro-scale diatoms, and cryptophytes prevailed in CCS. A clear split between CCS and NPSG is evident in dendogram visualising LINKTREE constrained binary divisive clustering analysis done on phytoplankton counts and pigment oncentrations. Of all pigments determined, alloxanthin, zeaxanthin, divinyl chlorophyll b and lutein have highest correlation to phytoplankton counts. Conclusion. Combining chemotaxonomy and microscopy is an optimal method to determine phytoplankton diversity on a large-scale transect. Distinct communities between the two contrasting ecosystems of North Pacific reveal phytoplankton groups specific adaptations to trophic state, and support the hypothesis of shift from microto nano-scale taxa due to sea surface temperatures rising, favoring stratification and oligotrophic conditions.

oceanography↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J. Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart J Pensinger↗

Progress on the Organic and Inorganic Modules of the Spacecraft Water Impurity Monitor, a Next Generation Complete Water Analysis System for Crewed Vehicles

The Spacecraft Water Impurity Monitor (SWIM) is a joint collaboration to develop an instrument platform that will perform in-flight measurements and deliver a more complete picture of water quality to decision makers. For exploration missions, returned water samples will not be an option, so spacecraft and habitats will need to be equipped with advanced water monitoring capabilities. Eventually, missions to the moon, Mars, and beyond should be equipped with analytical capabilities roughly analogous to those found in terrestrial labs. Based on what we know about current and future spacecraft environments, SWIM will seek to provide enhanced analytical capability that enables NASA to confidently send astronauts on distant missions without the possibility of returned water samples. The SWIM architecture can be broken down in an Organic Water Module (OWM) and an Inorganic Water Module (IWM), independent of each other but can be flown together if desired; an integrated system may share some commonality, e.g., single sample injection, sampling consumables, waste, etc. Each of these main modules can be broken down further into separation (if required) and detection modules. And, each separation module can be paired with one or more detection module depending on mission, spacecraft, customer needs, and size/mass/power constraints. This paper discusses the research and development progress toward the goal of a total water analysis system. For OWM, one of the analysis technologies that the SWIM team have been developing is a liquid-injection gas chromatograph mass spectrometer system; these systems are the workhorses of analytical chemistry laboratories world-wide. For IWM, the team is exploring a number of technologies ranging from traditional liquid chromatography technologies (e.g. ion chromatography, capillary electrophoresis) to flight-heritage technology such as ion-specific electrodes.

Stuart Pensinger↗

Enantioselective Three-Dimensional High-Performance Liquid Chromatographic Determination of Amino Acids in the Hayabusa2 Returned Samples from the Asteroid Ryugu

The chirality of amino acids in extraterrestrial materials may provide an insight into the origin of the essential L-enantiopure amino acids in the terrestrial biosphere. In 2020, the Hayabusa2 mission succeeded in bringing back surface materials from the C-type asteroid (162173) Ryugu to the Earth. Amino acids were one of the targeted organic molecules to be studied in the Ryugu samples. To analyze the various structural isomers of amino acids, which were expected to be present, from the limited amount of the returned samples, the development of a highly-sensitive and selective analytical method was necessary. In the present study, a three-dimensional high-performance liquid chromatography (3D-HPLC) system has been developed for the enantioselective determination of five proteinogenic and three non-proteinogenic amino acids in the Ryugu samples, in which amino acids in the sample were separated by reversed-phase, anion-exchange and enantioselective columns after the fluorescence derivatization with 4-fluoro-7-nitro-2,1,3-benzoxadiozole. The applicability of the analytical system to the extraterrestrial samples was evaluated by analyzing several types of carbonaceous meteorites before applying the system to the Ryugu samples. In the analysis of the Ryugu samples, all of the target amino acids were successfully determined quantitatively. Non-proteinogenic amino acids including 2-amino-n-butyric acid, isovaline and norvaline, rarely present in the terrestrial environment, were found as almost racemic mixtures with 47.1 to 55.2%L.

Amino acids↗

Characterizing intracellular proteomes for microbes: An experimental approach using label-free protein quantitation

Genomic and transcriptomic studies generate a rich source of molecular information; however, neither a static genome nor the presence of a messenger RNA provides the most direct insight into the functional state of a microbial cell at any given time. Rather, it is the ensemble of proteins (i.e., proteome) that is the primary workhorse for most biological processes that are concurrent and coordinately active in a living cell. Currently, mass-spectrometry-based (MS) technologies provide unprecedented information into the composition of the proteome, shedding light on the numerous complex biological processes actively shaping observed phenotypes. Herein, we detail a protocol for the exploration of intracellular proteomes through the large-scale, unbiased identification of proteins and their relative abundances using liquid chromatography (LC) coupled to tandem mass spectrometry (MS/MS). In general, this protocol is applicable to both microbial and eukaryotic systems.

Abraham, Paul↗

Mass spectrometry-based proteomics for analysis of hydrophilic phosphopeptides

Protein phosphorylation is a critical post-translational modification (PTM), with cell signaling networks being tightly regulated by protein phosphorylation. Despite recent technological advances in reversed-phase liquid chromatography (RPLC)-mass spectrometry (MS)-based proteomics, comprehensive phosphoproteomic coverage in complex biological systems remains challenging, especially for hydrophilic phosphopeptides that often have multiple phosphorylation sites. Herein we describe an MS-based phosphoproteomics protocol for effective quantitative analysis of hydrophilic phosphopeptides. This protocol was built upon a simple tandem mass tag (TMT)-labeling method for significantly increasing peptide hydrophobicity, thus effectively enhancing RPLC-MS analysis of hydrophilic peptides. Through phosphoproteomic analyses of MCF7 cells, this method was demonstrated to greatly increase the number of identified hydrophilic phosphopeptides and improve MS signal detection. With the TMT labeling method, we were able to identify a previously unreported phosphopeptide from the G protein-coupled receptor (GPCR) CXCR3, QPpSSSR, which is thought to be important in regulating receptor signaling. This protocol is easy to adopt and implement, and thus should have broad utility for effective RPLC-MS analysis of the hydrophilic phosphoproteome as well as other highly hydrophilic analytes.

Hydrophilic phosphopeptide, Phosphoproteomics, TMT↗

Mapping Influenza-Induced Posttranslational Modifications on Histones from CD8+ T Cells

T cell function is determined by transcriptional networks that are regulated by epigenetic programming via posttranslational modifications (PTMs) to histone proteins and DNA. Bottom-up mass spectrometry (MS) can identify histone PTMs, whereas intact protein analysis by MS can detect species missed by bottom-up approaches. We used a novel approach of online two-dimensional liquid chromatography-tandem MS with high-resolution reversed-phase liquid chromatography (RPLC), alternating electron transfer dissociation (ETD) and collision-induced dissociation (CID) on precursor ions to maximize fragmentation of uniquely modified species. The first online RPLC separation sorted histone families, then RPLC or weak cation exchange hydrophilic interaction liquid chromatography (WCX-HILIC) separated species heavily clad in PTMs. Tentative identifications were assigned by matching proteoform masses to predicted theoretical masses that were verified with tandem MS. We used this innovative approach for histone-intact protein PTM mapping (HiPTMap) to identify and quantify proteoforms purified from CD8 T cells after in vivo influenza infection. Activation significantly altered PTMs following influenza infection, histone maps changed as T cells migrated to the site of infection, and T cells responding to secondary infections had significantly more transcription enhancing modifications. Thus, HiPTMap identified and quantified proteoforms and determined changes in CD8 T cell histone PTMs over the course of infection.

mass spectrometry↗

On-Chip Microfluidic Components for In Situ Analysis, Separation, and Detection of Amino Acids

The Astrobiology Analytical Laboratory at GSFC has identified amino acids in meteorites and returned cometary samples by using liquid chromatography-electrospray ionization time-of-flight mass spectrometry (LCMS). These organic species are key markers for life, having the property of chirality that can be used to distinguish biological from non-biological amino acids. One of the critical components in the benchtop instrument is liquid chromatography (LC) analytical column. The commercial LC analytical column is an over- 250-mm-long and 4.6-mm-diameter stainless steel tube filled with functionized microbeads as stationary phase to separate the molecular species based on their chemistry. Miniaturization of this technique for spaceflight is compelling for future payloads for landed missions targeting astrobiology objectives. A commercial liquid chromatography analytical column consists of an inert cylindrical tube filled with a stationary phase, i.e., microbeads, that has been functionalized with a targeted chemistry. When analyte is sent through the column by a pressurized carrier fluid (typically a methanol/ water mixture), compounds are separated in time due to differences in chemical interactions with the stationary phase. Different species of analyte molecules will interact more strongly with the column chemistry, and will therefore take longer to traverse the column. In this way, the column will separate molecular species based on their chemistry. A lab-on-chip liquid analysis tool was developed. The microfluidic analytical column is capable of chromatographically separating biologically relevant classes of molecules based on their chemistry. For this analytical column, fabrication, low leak rate, and stationary phase incorporation of a serpentine microchannel were demonstrated that mimic the dimensions of a commercial LC column within a 5 10 1 mm chip. The microchannel in the chip has a 75- micrometer-diameter oval-shaped cross section. The serpentine microchannel has four different lengths: 40, 60, 80, and 100 mm. Functionized microbeads were filled inside the microchannel to separate molecular species based on their chemistry.

Zheng, Yun↗

Organosiloxane working fluids for the liquid droplet radiator

Siloxane-based working fluids for advanced space radiators requiring direct fluid exposure to the space environment are evaluated. Isolation of five candidate fluids by vacuum distillation from existing siloxane polymers is discussed. The five fluids recovered include a polydimethylsiloxane, three phenyl-containing siloxanes, and a methylhexylsiloxane. Vapor pressures and viscosities for the five fluids are reported over the temperature range of 250 to 400 K. Use of thermal-gravimetric analysis to reliably estimate vapor pressures of 10 to the -8 power Pascals is described. Polydimethylsiloxane (PDMS) and polymethylphenylsiloxane (PMPS) are selected from the five candidate fluids based on favorable vapor pressure and viscosity, as well as perceived stability in low-Earth orbit environments. Characterization of these fluids by infrared spectroscopy, Si-29 NMR, gel-permeation chromatography, and liquid chromatography is presented. Both fluids consist of narrow molecular weight distributions, with average molecular weights of about 2500 for PDMS and 1300 for PMPS.

Buch, R. R.↗

Extraction, purification, and reuse of dyes from coloured polyester textiles

The removal of dyes from coloured textile waste represents a sustainable approach to textile recycling, enabling the recovery of valuable chemical, and material resources that would otherwise be discarded. Up to 40% of the greenhouse gas emissions from textiles originate from dye production, making efficient recycling of dyes a major opportunity for curbing emissions and minimizing waste in both textile manufacturing and recycling. Here, in this study, we demonstrate a process for the extraction, purification, and reuse of mixed dyes from polyester textiles using bio-based, non-hazardous solvents selected on the basis of computational predictions for polyester and dye solubilities. Extracted dyes are purified to individual compounds using counter-current chromatography and analysed via liquid chromatography-mass spectrometry. Post-extraction characterization of the extracted dyes and polymer substrate confirms dye colour retention and polyester fabric property preservation. Dye recycling is demonstrated by redyeing colour-free fabrics with the recovered dyes. We further show a potential process configuration for dye removal using a flow-through reactor packed with a textile substrate. The proposed dye removal process produces reusable, recyclable dyes, and dye-free fabrics, thus facilitating textile recycling.

36 MATERIALS SCIENCE↗

Characterizing Olefin Selectivity and Stability of Silver Salts in Ionic Liquids Using Inverse Gas Chromatography

Separation systems utilizing silver(I) ion-olefin complexation have limitations since silver(I) ions can be poisoned or reduced to metallic silver. Ionic liquids (ILs) are used as solvents for silver(I) ions to facilitate separations since their physico-chemical properties can be easily tuned. To develop separation systems with sustainable olefin selectivity, factors that affect silver(I) ion stability need to be understood. In this study, a total of 13 silver salt/IL mixtures were examined by inverse gas chromatography to identify the effects of silver salt anion and IL cation/anion combination on silver(I) ion stability. The effects of temperature and three different exposure gases on silver(I) ion stability were systematically studied. Exposing silver salt/IL mixtures to hydrogen at high temperatures had a greater effect on decreasing silver(I) ion-olefin complexation. Silver(I) ions from the silver bis[(trifluoromethyl)sulfonyl]imide ([NTf 2 – ]) salt were more stable in [NTf 2 – ]-containing ILs than in [BF 4 – ]-containing ILs. Optimum mixtures exhibited high olefin selectivity and were stable beyond 90 h when exposed to hydrogen gas.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗