Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Uncertainty Analysis of the GeoNEX Top-of-Atmospheric Reflectance Products Generated from the Third-Generation Geostationary Satellite Sensors

The GeoNEX (Geostationary-NASA Earth eXchange) Level-1G products consist of top-of-atmosphere (TOA) bi-directional reflectance factor (BRF) and brightness temperature generated with data streams from the latest geostationary (GEO) sensors including GOES-16/17 ABI, Himawari-8/9 AHI, and GK-2A AMI on a global tiled common grid (60oN-60o and 180oW-180oE) in geographic coordinates. With their 16 spectral bands, 0.01o/0.02o nadir spatial resolution, and 10-minute temporal resolutions, these products provide exciting opportunity to monitor Earth surface processes. However, the unique Sun-Target-Satellite geometry of geostationary sensors demands special attention in analyzing/interpreting these datasets. In this study we present a systematic analysis on the relationship between the radiometric uncertainties of the GeoNEX TOA reflectance and the corresponding solar/satellite zenith angles. We show that the signal-to-noise ratio (SNR) of the BRF are positively proportional to the square roots of the cosine of solar illuminating zenith angles. That is, the BRF data are noisier earlier in the morning or later in the afternoon than in the mid of the day. The cosine of satellite viewing zenith angles do not directly influence the SNR of the TOA BRF. However, they positively regulate the relative importance of the surface component in the TOA BRF. This means that variations in surface reflectance are more difficult to detect for pixels with larger view zenith angles, even when the SNR of the TOA BRF is the same. We are developing metrics to specify such illumination-view geometry related uncertainties in the GeoNEX L1G TOA BRF products so that this key information can be easily accessed by the user community.

Geostationary satellite↗

Evaluation of Carbon Dioxide Sensors for the Constellation Space Suit Life Support System for Surface Exploration

This paper presents the findings of the trade study to evaluate carbon dioxide (CO2) sensing technologies for the Constellation (Cx) space suit life support system for surface exploration. The trade study found that nondispersive infrared absorption (NDIR) is the most appropriate high Technology Readiness Level (TRL) technology for the CO2 sensor for the Cx space suit. The maturity of the technology is high, as it is the basis for the CO2 sensor in the Extravehicular Mobility Unit (EMU). The study further determined that while there is a range of commercial sensors available, the Cx CO2 sensor should be a new design. Specifically, there are light sources (e.g., infrared light emitting diodes) and detectors (e.g., cooled detectors) that are not in typical commercial sensors due to cost. These advanced technology components offer significant advantages in performance (weight, volume, power, accuracy) to be implemented in the new sensor. The exact sensor design (light source, transmitting optics, path length, receiving optics and detector) will be specific for the Cx space suit and will be determined by the performance requirements of the Cx space suit. The paper further identifies specifications for some of the critical performance parameters as well as discussing the engineering aspects of implementing the sensor into the Portable Life Support System (PLSS). The paper then presents testing results from three CO2 sensors with respect to issues important to Extravehicular Activity (EVA) applications; stability, humidity dependence and low pressure compatibility. The three sensors include two NDIR sensors, one commercial and one custom-developed by NASA (for a different purpose), and one commercial electrochemical sensor. The results show that both NDIR sensors have excellent stability, no dependence on ambient humidity (when the ambient temperature is above the dew point) and operate in low pressure conditions and after being exposed to a full vacuum. The commercial electrochemical sensor was not suitable for the Cx space suit for surface exploration. Finally, the paper identifies a number of techniques currently under development that offer significant advantages for EVA applications. These include miniaturized, room temperature, solid electrolyte systems and advanced optical detectors.

Dietrich, Daniel L.↗

Wind shear predictive detector technology study status

Among the different elements to be investigated when considering the Wind Shear hazard, the Aeronautical Navigation Technical Service (STNA/3E), whose task is to participate in the development of new technologies and equipments, focused its effort on airborne and ground sensors for the detection of low-level wind shear. The first task, initiated in 1986, consists in the evaluation of three candidate techniques for forward-looking sensors: lidar, sodar, and radar. No development is presently foreseen for an infrared based air turbulence advance warning system although some flight experiments took place in the 70's. A Thomson infrared radiometer was then installed on an Air France Boeing 707 to evaluate its capability of detecting clear air turbulence. The conclusion showed that this technique was apparently able to detect cloud layers but that additional experiments were needed; on the other hand, the rarity of the phenomenon and the difficulty in operating on a commercial aircraft were also mentioned.

Gandolfi, C.↗

Determining robot actions for tasks requiring sensor interaction

The performance of non-trivial tasks by a mobile robot has been a long term objective of robotic research. One of the major stumbling blocks to this goal is the conversion of the high-level planning goals and commands into the actuator and sensor processing controls. In order for a mobile robot to accomplish a non-trivial task, the task must be described in terms of primitive actions of the robot's actuators. Most non-trivial tasks require the robot to interact with its environment; thus necessitating coordination of sensor processing and actuator control to accomplish the task. The main contention is that the transformation from the high level description of the task to the primitive actions should be performed primarily at execution time, when knowledge about the environment can be obtained through sensors. It is proposed to produce the detailed plan of primitive actions by using a collection of low-level planning components that contain domain specific knowledge and knowledge about the available sensors, actuators, and sensor/actuator processing. This collection will perform signal and control processing as well as serve as a control interface between an actual mobile robot and a high-level planning system. Previous research has shown the usefulness of high-level planning systems to plan the coordination of activities such to achieve a goal, but none have been fully applied to actual mobile robots due to the complexity of interacting with sensors and actuators. This control interface is currently being implemented on a LABMATE mobile robot connected to a SUN workstation and will be developed such to enable the LABMATE to perform non-trivial, sensor-intensive tasks as specified by a planning system.

Budenske, John↗

Flexible Cryogenic Temperature and Liquid-Level Probes

Lightweight, flexible probes have been developed for measuring temperatures at multiple locations in tanks that contain possibly pressurized cryogenic fluids. If the fluid in a given tank is subcritical (that is, if it consists of a liquid and its vapor), then in one of two modes of operation, the temperature measurements made by a probe of this type can be used to deduce the approximate level of the liquid. The temperature sensors are silicon diodes located at intervals along a probe. If the probe is to be used to measure a temperature gradient along a given axis in the tank, then the probe must be mounted along that axis. In the non-liquid-level-sensing temperature-measurement mode, a constant small electric current is applied to each diode and the voltage across the diode . a known function of the current and temperature . is measured as an indication of its temperature. For the purpose of this measurement, "small electric current" signifies a current that is not large enough to cause a significant increase in the measured temperature. More specifically, the probe design calls for a current of 10 A, which, in the cryogenic temperature range of interest, generates heat at a rate of only about 0.01 mW per diode. In the liquid-level-sensing mode, one applies a larger current (30 mA) to each diode so as to heat each diode appreciably (with a power of about 36 mW in the temperature range of interest). Because the liquid cools the diode faster than does the vapor, the temperature of the diode is less when diode is immersed in the liquid than when it is above the surface of the liquid. Thus, the temperature (voltage) reading from each diode can be used to determine whether the liquid level is above or below the diode, and one can deduce that the liquid level lies between two adjacent diodes, the lower one of which reads a significantly lower temperature. The aforementioned techniques for measuring temperature and deducing liquid level are not new. What is new here are the designs of the probes and of associated external electronic circuitry. In each probe, the diodes and the lead wires are embedded in a strong, lightweight, flexible polyimide strip. Each probe is constructed as an integral unit that includes a multipin input/output plug or socket for solderless connection of the lead wires to the external circuitry. The polyimide strip includes mounting tabs with holes that can accommodate rivets, screws, or other fasteners. Alternatively, a probe can be mounted by use of an epoxy. A probe can be manufactured to almost any length or width, and the diodes can be embedded at almost any desired locations along and across the polyimide strip. In designing a probe for a specific application, one seeks a compromise between (1) minimizing the number of diodes in order to minimize the complexity of input/output connections and external electronic circuitry while (2) using enough diodes to obtain the required precision. Optionally, to minimize spurious heating of the cryogenic fluid, the external circuitry can be designed to apply power to the probe only during brief measurement intervals. Assuming that the external circuitry is maintained at a steady temperature, a power-on interval of only a few seconds is sufficient to obtain accurate data on temperatures and/or the height of the liquid/vapor interface.

Haberbusch, Mark↗

Comparing Low-Cost Sensors with Ground-Based and Airborne In-Situ and Column Observations of NO2 and HCHO during the FRAPPE Field Campaign in Colorado, USA

Even in the presence of more reliable air quality tools, low-cost sensors have the benefit of recording data on highly localized spatial and temporal scales, allowing for multiple measurements within a single satellite pixel and on pixel boundaries. However, they are less accurate than their regulatory-grade counterparts, requiring regular co-locations with accepted instruments to ensure their validity. Thus, the addition of low-cost sensors to a field campaign – where reference-grade air quality instruments are abundant – not only provides ample opportunities for low-cost sensor co-location and calibration, but also allows the low-cost instruments to be used for sub-pixel validation, covering more surface area than the regulatory instruments alone with a network of sensors. During the summer of 2014, our low-cost sensor network was deployed during the Front Range Air Pollution and Photochemistry Experiment (FRAPPÉ) campaign conducted to sample the composition of air at and above ground level in northeastern Colorado, USA. The low-cost sensor platform included a suite of gas-phase sensors, notably NO2 and two generalized volatile organic compound (VOC) sensors, which were leveraged together to quantify speciated hydrocarbons such as formaldehyde. These key pollutants were chosen for their impacts on human health and climate change, as well as their inclusion on the TEMPO satellite launching this year. Airborne campaign measurements included slant column optical observations of formaldehyde (HCHO), nitrogen dioxide (NO2), and ozone (O3). Myriad additional in-situ instruments described chemical composition up to approximately 5 km above surface level. Ground-based instrumentation included both stationary and mobile regulatory-grade instruments, which were used for sensor calibration. Machine learning techniques such as artificial neural networks (ANNs) were used to match the low-cost signals to that of the reference-grade instruments. Here, we compare calibrated low-cost sensor data collected at ground level in a variety of locations along Colorado’s Front Range to various data sources from the FRAPPÉ campaign to better understand how well airborne and regulatory ground-based measurements can be extrapolated to other locations. Further, as the slant column measurements act as satellite simulators, we explore how low-cost instruments can be used for satellite validation purposes. Comparisons among these different data types also have important implications in data fusion.

Kristen Okorn↗

Integrated Hydrogen Sensor and Separator for Parabolic Trough Expansion Tanks

The National Renewable Energy Laboratory (NREL) and Acciona Energy USA Global are developing and implementing a process that addresses the issue of hydrogen buildup in parabolic trough power plants. Our method selectively removes hydrogen from the expansion tanks of the power plant to control hydrogen levels in the circulating heat-transfer fluid (HTF). As part of this effort, we developed a sensor that measures hydrogen partial pressure in the expansion-tank headspace gas. During previous work, we demonstrated that our sensor measures hydrogen levels over a wide range of partial pressure from 1.33 mbar down to 0.003 mbar. In this paper, we report our most recent work, in which we conceived and developed an integrated process module that performs both hydrogen sensing and separating functions. The sensor/separator measures hydrogen partial pressure in the headspace gas in the same way as our original sensor design. Additionally, the integrated module separates hydrogen from the headspace gas to reduce hydrogen to the level needed to maintain the performance of receivers in the collector field. Sensor data from the integrated module also provide an estimate of the rate at which hydrogen is being extracted from the headspace gas. We designed and fabricated a laboratory-scale integrated module and determined its performance in our laboratory at NREL. Testing showed that the module performed as expected in both sensing and separating modes. The accuracy of the sensing function was +/-10%. The hydrogen extraction rate for the separating mode was consistent with our modeling predictions. The primary benefit of this module is its simple design, both in terms of function and incorporation into the HTF subsystem of the power plant. The integrated module can be installed close to the HTF expansion tanks, where it draws headspace gas from the tanks, removes hydrogen, and returns the treated gas back to the tanks. We are currently installing a test-scale process at the Nevada Solar One (NSO) power plant to demonstrate this process and determine its operational performance. Results from the test-scale process will be used to specify and design the full-scale process that will be installed at NSO.

14 SOLAR ENERGY↗

Illumination control apparatus for compensating solar light

An illumination control apparatus is presented for supplementing light from solar radiation with light from an artificial light source to compensate for periods of insufficient levels of solar light. The apparatus maintains a desired illumination level within an interior space comprising an artificial light source connected to an electrical power source with a switch means for selectively energizing said light source. An actuator means for controlling the on-off operation of the switch means is connected to a light sensor which responses to the illumination level of the interior space. A limit switch carried adjacent to the actuator limits the movement of the actuator within a predetermined range so as to prevent further movement thereof during detection of erroneous illumination conditions.

Owens, L. J.↗

Ag-LaFeO3 nanoparticles using molecular imprinting technique for selective detection of xylene

Highlights: • Ag-LaFeO{sub 3} based gas sensor using molecular imprinting technique has been successfully applied to the detection of xylene. • Ultrahigh response (resistance ratio = 36.2) to 5 ppm xylene is achieved. • The optimal operating temperature (99 °C) is extremely low. - Abstract: Xylene is a hazardous volatile organic compound, however, the selective detection of ppm-level xylene using oxide semiconductor gas sensor remains a challenging issue. In this study, Ag-LaFeO{sub 3} was modified with molecular imprinting technique, in which methacrylic acid and hydroxyethyl methylacrylate are used as functional monomers, respectively. Based on XRD, EDS, XPS, SEM, TEM, BET nitrogen adsorption observations, the structure and morphology of the samples are characterized. The as-prepared molecularly imprinted nanoparticles with methacrylic acid as functional monomer exhibit high selectivity and response to xylene gas, and the response is dependent on the type and content of the functional monomer. To 5 ppm xylene, the optimal response is 36.2 at the operating temperature of 99 °C. In addition, low cross-responses to the other test gases were observed. The remarkable enhancement in the gas-sensing properties of the samples is attributed to their high specific surface area and molecular imprinting structure.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

An RF Sensor for Gauging Screen-Channel Liquid Acquisition Devices for Cryogenic Propellants

A key requirement of a low-gravity screen-channel liquid acquisition device (LAD) is the need to retain 100% liquid in the channel in response to propellant outflow and spacecraft maneuvers. The point at which a screen-channel LAD ingests vapor is known as breakdown, and can be measured several different ways such as: visual observation of bubbles in the LAD channel outflow; a sudden change in pressure drop between the propellant tank and LAD sump outlet; or, an indication by wet-dry sensors placed in the LAD channel or outflow stream. Here we describe a new type of sensor for gauging a screen-channel LAD, the Radio Frequency Mass Gauge (RFMG). The RFMG measures the natural electromagnetic modes of the screen-channel LAD, which is very similar to an RF waveguide, to determine the amount of propellant in the channel. By monitoring several of the RF modes, we show that the RFMG acts as a global sensor of the LAD channel propellant fill level, and enables detection of LAD breakdown even in the absence of outflow. This paper presents the theory behind the RFMG-LAD sensor, measurements and simulations of the RF modes of a LAD channel, and RFMG detection of LAD breakdown in a channel using a simulant fluid during inverted outflow and long-term stability tests.

microwave sensor↗

DIRECT SIMULTANEOUS MEASUREMENT OF PARTICULATE MATTER AND AMMONIA STORAGE ON COMBINED SELECTIVE CATALYTIC REDUCTION FILTER SYSTEMS USING RADIO FREQUENCY SENSORS

Tightening global emissions regulations are motivating interest in the development and implementation of Selective Catalytic Reduction + Filtration (SCRF) systems, which are designed to reduce the concentration of tailpipe particulate matter (PM) and NO x emissions. These systems allow designers to combine the NO x reduction capability of an SCR with the filtration capability of a particulate filter on a single unit. Practical implementation of these systems requires reliable measurement and diagnosis of their state – both with respect to trapped particulate matter as well as adsorbed ammonia. Currently, these systems rely on a variety of gas sensors, mounted upstream or downstream of the system, that only provide an indirect inference of the operation state. In this study, a single radio frequency (RF) sensor was used to perform simultaneous measurements of soot loading and ammonia inventory on an SCRF. Several SCRF core samples were tested at varying soot and ash loads in a catalyst reactor bench. Soot levels were measured by monitoring changes in the bulk dielectric properties within the catalyst using the sensor, while ammonia levels were determined by feeding selected regions of the RF spectrum into a pretrained generalized regression neural network model. Results show the RF sensor is able to directly measure the instantaneous ammonia inventory, while simultaneously providing soot loading measurements within 0.5 g/L. These results confirm that simultaneous measurements of both the PM and ammonia loading state of an SCRF are possible using a single RF sensor via analysis of specific features in the full RF spectrum. The results indicate significant potential to remove the control barriers typically associated with the implementation of advanced SCRF systems.

Ragaller, Paul↗

A Vibrational Energy Harvesting Sensor Based on Linear and Rotational Electromechanical Effects

In this investigation, a magnetically coupled double-spring design is presented for harvesting low-level non-stationary random vibrational energy. The sensor relies on multimodal coupling between the translation and rotation of a two-spring magnet and coil system to widen the harvesting bandwidth. Energy methods are used to develop a model to characterize the electromechanical response of the system, the solution of which is obtained using stochastic techniques based on a particle swarm algorithm. This approach provides an efficient method to estimate system parameters that otherwise are difficult or impossible to determine with independent measurements. The experimental results demonstrate agreement with the theoretical predictions over a limited bandwidth. The sensor can effectively harvest non-stationary vibration energy down to 10 -4 g within a limited bandwidth of 130–150 Hz. The sensor prototype has an operational volume of 2.6 cm 3 with a calculated power density of 0.2 W/cm 3 . The sensor’s small size results in a coupling efficiency of approximately 6% across the tested bandwidth.

42 ENGINEERING↗

Development of a Magneto-Resistive Angular Position Sensor for Space Mechanisms

Magnetic microsystems in the form of magneto-resistive (MR) sensors are firmly established in automobiles and industrial applications. They are used to measure travel, angle, electrical current, or magnetic fields. MR technology opens up new sensor possibilities in space applications and can be an enabling technology for optimal performance, high robustness and long lifetime at reasonable costs. In some science missions, the technology is already applied, however, the designs are proprietary and case specific, for instance in case of the angular sensors used for JPL/NASA's Mars rover Curiosity [1]. Since 2013 HTS GmbH and Sensitec GmbH have teamed up to develop and qualify a standardized yet flexible to use MR angular sensor for space mechanisms. Starting with a first assessment study and market survey performed under ESA contract, a very strong industry interest in novel, contactless position measurement means was found. Currently a detailed and comprehensive development program is being performed by HTS and Sensitec. The objective of this program is to advance the sensor design up to Engineering Qualification Model level and to perform qualification testing for a representative space application. The paper briefly reviews the basics of magneto-resistive effects and possible sensor applications and describes the key benefits of MR angular sensors with reference to currently operational industrial and space applications. The key applications and specification are presented and the preliminary baseline mechanical and electrical design will be discussed. An outlook on the upcoming development and test stages as well as the qualification program will be provided.

Hahn, Robert↗

Multi-Sensor Aerosol Products Sampling System

Global and local properties of atmospheric aerosols have been extensively observed and measured using both spaceborne and ground-based instruments, especially during the last decade. Unique properties retrieved by the different instruments contribute to an unprecedented availability of the most complete set of complimentary aerosol measurements ever acquired. However, some of these measurements remain underutilized, largely due to the complexities involved in analyzing them synergistically. To characterize the inconsistencies and bridge the gap that exists between the sensors, we have established a Multi-sensor Aerosol Products Sampling System (MAPSS), which consistently samples and generates the spatial statistics (mean, standard deviation, direction and rate of spatial variation, and spatial correlation coefficient) of aerosol products from multiple spacebome sensors, including MODIS (on Terra and Aqua), MISR, OMI, POLDER, CALIOP, and SeaWiFS. Samples of satellite aerosol products are extracted over Aerosol Robotic Network (AERONET) locations as well as over other locations of interest such as those with available ground-based aerosol observations. In this way, MAPSS enables a direct cross-characterization and data integration between Level-2 aerosol observations from multiple sensors. In addition, the available well-characterized co-located ground-based data provides the basis for the integrated validation of these products. This paper explains the sampling methodology and concepts used in MAPSS, and demonstrates specific examples of using MAPSS for an integrated analysis of multiple aerosol products.

Petrenko, M.↗

Modeling non-gravitational forces acting on TOPEX/POSEIDON: The early days

TOPEX/POSEIDON is a satellite mission that will use altimetry to make precise measurements of sea-level. The principal goal is to measure sea-level with unprecedented accuracy such that small-amplitude, basin wide sea-level changes caused by large-scale ocean circulation can be detected. To reach this goal, the sensor system and orbit must measure sea-level with decimeter accuracy. This requires that the radial component of the orbit be known to the decimeter level. Orbital errors are dominated by mismodelled gravitational and non-gravitational forces. This paper presents our analysis of non-gravitational forces acting on the satellite during the early days of the mission. Studies were conducted by comparing direct estimates of these forces with observed perturbations in the mean orbital elements. The results show that the satellite is experiencing an unexpected along-track acceleration. Hypotheses range from out-gassing to thruster leaks and drag forces to radiative force. Currently, these issues have not been resolved; however, the evidence suggests that out-gassing was dominant during the first weeks of the mission and that thermal imbalances persist.

Christensen, E. J.↗

Microbial potentiometric sensor: A new approach to longstanding challenges

The underlying hypothesis of this study is that simple potentiometric measurements between sensing electrodes and a shared reference electrode - Microbial Potentiometric Sesnor (MPS) system - can be employed in a long-term, continuous mode of operation to resolve the spatial and temporal changes in environmental systems. To address the hypothesis, (1) a conceptual description of the MPS system and its postulated principle of operation are provided; (2) the MPS system performance is documented under controlled laboratory conditions; and (3) the capabilities of the MPS system are documented under quiescent and dynamic field condition. In a laboratory setting, the variability among different MPS signals was insignificant confirming the postulated high accuracy and reproducibility of the sensor performance. It also demonstrated statistically significant correlations with dissolved oxygen (DO) and oxidation-reduction potential (ORP) sensors, while showing capabilities of operating under anoxic and anaerobic conditions. Regardless of their locations in the model wetland system, three MPS sensors functioned without interruption and cleaning for a period >2 years, and thus demonstrating long-term durability of the MPS technology. In real batch-wastewater treatment facility, the deployed MPS system signals were able to describe the organic carbon trends and correlate with each treatment phase in a cycle. Data reproducibility and reliability exceeded the expectations better describing the carbon treatment levels than the DO and ORP sensors (p < 4.4 × 10 –162 vs phase adjusted p < 3.0 × 10 –58 ). While MPS signals correlate with specific parameters that describe the local process or environments, it is more prudent to employ both the magnitude and pattern of a composite signal like the MPS signal describe the change to reflect any shift in the local environment. Finally, when compared to a baseline pattern, this change in signal magnitude and pattern reveals important information that can be employed to tailor and optimize any condition or process which involves microorganisms.

47 OTHER INSTRUMENTATION↗

Analysis of a Runtime Data Sharing Architecture over LTE for a Heterogeneous CAV Fleet

This paper describes a lightweight runtime architecture for telemetry, communication, and control of cars deployed with advanced driver assistance systems where a human is in the loop with the car, via an LTE connection. The system architecture supports both local control decisions based on car sensors and safety algorithms as well as high-level input from external systems that may provide insight into traffic state ahead of sensor data. Implementation of the architecture is done in ROS and depends on open-source software packages for runtime decoding of information from the vehicle’s controller area network (CAN) and integration of GPS data from accompanying sensors. The contribution of the paper is to describe the overall architecture, the data it can communicate to other systems, performance of the system at runtime, and challenges faced when deploying the architecture across a heterogeneous fleet. Preliminary results from analysis of test data will provide insights into whether the use of high-latency communication can be effective for societal-scale intelligent transportation systems when applied in future scenarios

Richardson, Alex↗

Photosynthetically Active Radiation (PAR) Instrument Handbook

Three photosynthetically active radiation (PAR) measurement instruments were deployed at the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility’s Bankhead National Forest (BNF) observatory, installed on three different instrument towers within the forest. Each of the three instruments comprises an enclosure at the base of the tower, containing a datalogger and internal humidity sensor, connected to external PAR sensors mounted at various heights and vertical orientations on the same tower. PAR sensors measure radiation reaching the sensor with wavelengths from 400-700 nm, per unit area, per unit time, or the photosynthetic photon flux density (PPFD, µmol photons m -2 s -1 ). On the 43-meter tower of BNF supplemental site S10, sensors are located 43 m, 22 m, 10 m, and 5 m from ground level. Downwelling radiation is measured with upward-facing sensors at all heights, and upwelling radiation is measured with downward-facing sensors at 43 m and 5 m. On the two 10-m towers of BNF supplemental sites S13 and S14, upwelling radiation is measured at 8 m and 2 m, and downwelling radiation is measured at 8 m.

54 ENVIRONMENTAL SCIENCES↗