Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Experimental test of instability enhanced collisional friction for determining ion loss in two ion species plasmas

Recent experiments have shown that ions in weakly collisional plasmas containing two ion species of comparable densities approximately reach a common velocity at the sheath edge equal to the bulk plasma ion sound velocity. A recent theory [S. D. Baalrud, C. C. Hegna, and J. D. Callen, Phys. Rev. Lett. 103, 205002 (2009)] suggests that this is a consequence of collisional friction between the two ion species enhanced by the two stream instability. The theory finds that the difference in velocities at the sheath edge depends on the relative concentrations of the two ions. The difference in velocities is small, with both species approaching to the bulk sound velocity, when the concentrations are comparable, and is large, with each species reaching its own Bohm velocity, when the relative concentration differences are large. To test these findings, drift velocities of Ar and Xe ions were measured with laser-induced fluorescence in Ar-Xe and He-Xe plasmas and combined with ion acoustic wave and plasma potential data. In addition, electron temperature was varied by a Maxwell demon [K. R. MacKenzie et al., App. Phys. Lett. 18, 529 (1971)]. The predictions were found to be in excellent agreement with the experimental data. The generalized Bohm criterion in two ion species plasmas is also verified in a wider variety of relative ion concentrations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The direct injection of intense ion beams from a high field electron cyclotron resonance ion source into a radio frequency quadrupole

The ion current achievable from high intensity ECR sources for highly charged ions is limited by the high space charge. This makes classical extraction systems for the transport and subsequent matching to a radio frequency quadrupole (RFQ) accelerator less efficient. The direct plasma injection (DPI) method developed originally for the laser ion source avoids these problems and uses the combined focusing of the gap between the ion source and the RFQ vanes (or rods) and the focusing of the rf fields from the RFQ penetrating into this gap. For high performance ECR sources that use superconducting solenoids, the stray magnetic field of the source in addition to the DPI scheme provides focusing against the space charge blow-up of the beam. A combined extraction/matching system has been designed for a high performance ECR ion source injecting into an RFQ, allowing a total beam current of 10 mA from the ion source for the production of highly charged {sup 238}U{sup 40+} (1.33 mA) to be injected at an ion source voltage of 60 kV. In this design, the features of IGUN have been used to take into account the rf-focusing of an RFQ channel (without modulation), the electrostatic field between ion source extraction and the RFQ vanes, the magnetic stray field of the ECR superconducting solenoid, and the defocusing space charge of an ion beam. The stray magnetic field is shown to be critical in the case of a matched beam.

43 PARTICLE ACCELERATORS↗

The role of space charge compensation for ion beam extraction and ion beam transport (invited)

Depending on the specific type of ion source, the ion beam is extracted either from an electrode surface or from a plasma. There is always an interface between the (almost) space charge compensated ion source plasma, and the extraction region in which the full space charge is influencing the ion beam itself. After extraction, the ion beam is to be transported towards an accelerating structure in most cases. For lower intensities, this transport can be done without space charge compensation. However, if space charge is not negligible, the positive charge of the ion beam will attract electrons, which will compensate the space charge, at least partially. The final degree of Space Charge Compensation (SCC) will depend on different properties, like the ratio of generation rate of secondary particles and their loss rate, or the fact whether the ion beam is pulsed or continuous. In sections of the beam line, where the ion beam is drifting, a pure electrostatic plasma will develop, whereas in magnetic elements, these space charge compensating electrons become magnetized. The transport section will provide a series of different plasma conditions with different properties. Different measurement tools to investigate the degree of space charge compensation will be described, as well as computational methods for the simulation of ion beams with partial space charge compensation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Ion temperature gradient driven turbulence with strong trapped ion resonance

A theory to describe basic characterization of ion temperature gradient driven turbulence with strong trapped ion resonance is presented. The role of trapped ion granulations, clusters of trapped ions correlated by precession resonance, is the focus. Microscopically, the presence of trapped ion granulations leads to a sharp (logarithmic) divergence of two point phase space density correlation at small scales. Macroscopically, trapped ion granulations excite potential fluctuations that do not satisfy dispersion relation and so broaden frequency spectrum. The line width from emission due only to trapped ion granulations is calculated. The result shows that the line width depends on ion free energy and electron dissipation, which implies that non-adiabatic electrons are essential to recover non-trivial dynamics of trapped ion granulations. Relevant testable predictions are summarized.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of a compact ECR ion source for various ion production

There is a desire that a carbon-ion radiotherapy facility will produce various ion species for fundamental research. Although the present Kei2-type ion sources are dedicated for the carbon-ion production, a future ion source is expected that could provide: (1) carbon-ion production for medical use, (2) various ions with a charge-to-mass ratio of 1/3 for the existing Linac injector, and (3) low cost for modification. A prototype compact electron cyclotron resonance (ECR) ion source, named Kei3, based on the Kei series has been developed to correspond to the Kei2 type and to produce these various ions at the National Institute of Radiological Sciences (NIRS). The Kei3 has an outer diameter of 280 mm and a length of 1120 mm. The magnetic field is formed by the same permanent magnet as Kei2. The movable extraction electrode has been installed in order to optimize the beam extraction with various current densities. The gas-injection side of the vacuum chamber has enough space for an oven system. We measured dependence of microwave frequency, extraction voltage, and puller position. Charge state distributions of helium, carbon, nitrogen, oxygen, and neon were also measured.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of core ion temperature gradients and edge sheared flows in a helicon plasma device investigated by laser induced fluorescence measurements

We report experimental observation of ion heating and subsequent development of a prominent ion temperature gradient in the core of a linear magnetized plasma device, and the controlled shear de-correlation experiment. Simultaneously, we also observe the development of strong sheared flows at the edge of the device. Both the ion temperature and the azimuthal velocity profiles are quite flat at low magnetic fields. As the magnetic field is increased, the core ion temperature increases, producing centrally peaked ion temperature profiles and therefore strong radial gradients in the ion temperature. Similarly, we observe the development of large azimuthal flows at the edge, with increasing magnetic field, leading to strong radially sheared plasma flows. The ion velocities and temperatures are derived from laser induced fluorescence measurements of Doppler resolved velocity distribution functions of argon ions. These features are consistent with the previous observations of simultaneously existing radially separated multiple plasma instabilities that exhibit complex plasma dynamics in a very simple plasma system. The ion temperature gradients in the core and the radially sheared azimuthal velocities at the edge point to mechanisms that can drive the multiple plasma instabilities, that were reported earlier.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental investigation of beam-ion losses induced by magnetic perturbations using the light ion beam probe technique in the ASDEX Upgrade tokamak

The impact of externally applied magnetic perturbations (MPs) on fast-ion losses has been investigated by means of the light ion beam probe (LIBP) technique in the ASDEX Upgrade tokamak. The LIBP technique allows to experimentally infer the fast-ion orbit displacement induced by MPs via first-orbit losses using scintillator based fast-ion loss detector (FILD) measurements. The fast-ion orbit displacement against different applied MP spectra has been studied. These shots were conducted in ELM mitigated H-mode plasmas. A rigid rotation of the MP coils was applied with a frequency of 1 Hz, with an n = 2 configuration and changing the differential phase between the upper and lower set of coils (ΔΦ ul ) on a shot-to-shot basis. Beam sources Q7 (tangential) and Q8 (radial) were used to probe different fast-ion orbits with FILD1. The measured fast-ion orbit displacement ranges from 3 to 20 mm approximately, and no qualitative difference is observed between ions from beam sources Q7 and Q8. The minimum is found for a ΔΦ ul ~ 50°, which is shifted with respect to the minimum of the plasma boundary displacement, found at ΔΦ ul ~ 0°. A first attempt to validate the orbit following code ASCOT—including the plasma response calculated with the MARS-F code—against these experimental measurements is performed. Finally, while the dependence of the first-orbit fast-ion displacement with ΔΦ ul does not match the experimental measurements, these simulations do capture other features such as the order of magnitude of the orbit displacement and the importance of the toroidal spectrum of the applied perturbation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evidence for Fast-Ion Transport by Microturbulence

Cross-field diffusion of energetic ions by microturbulence is measured during neutral-beam injection into the DIII-D tokamak. Fast-ion D{sub {alpha}}, neutron, and motional Stark effect measurements diagnose the fast-ion distribution function. As expected for transport by plasma turbulence, anomalies relative to the classical prediction are greatest in high temperature plasmas, at low fast-ion energy, and at larger minor radius. Theoretical estimates of fast-ion diffusion are comparable to experimental levels.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ion-Optical System of an Ion Source with Energy Focusing in the Formed Beam

Ways to reduce ion beam intensity losses in a mass spectrometric ion source, which are caused by chromatic aberration of its immersion ion-optical system, are considered. These losses are rather significant in forming a beam from ions with a large energy spread. The reduction of aberration losses is especially important when ion sources are used jointly with mass analyzers with energy focusing. It is shown that these losses can be reduced significantly by using a new type of ion-optical system of the ion source, which includes achromatic elements. A special method for calculating such elements is given. Computer simulations have shown high efficiency of such elements in the ion-optical path of ion sources of mass spectrometers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimizing Normal Tissue Sparing in Ion Therapy Using Calculated Isoeffective Dose for Ion Selection

Purpose: To investigate how the selection of ion type affects the calculated isoeffective dose to the surrounding normal tissue as a function of both normal tissue and target tissue {alpha}/{beta} ratios. Methods and Materials: A microdosimetric biologic dose model was incorporated into a Geant4 simulation of parallel opposed beams of protons, helium, lithium, beryllium, carbon, and neon ions. The beams were constructed to give a homogeneous isoeffective dose to a volume in the center of a water phantom for target tissues covering a range of cobalt equivalent {alpha}/{beta} ratios of 1-20 Gy. Concomitant normal tissue isoeffective doses in the plateau of the ion beam were then compared for different ions across the range of normal tissue and target tissue radiosensitivities for a fixed isoeffective dose to the target tissue. Results: The ion type yielding the optimal normal tissue sparing was highly dependent on the {alpha}/{beta} ratio of both the normal and the target tissue. For carbon ions, the calculated isoeffective dose to normal tissue at a 5-cm depth varied by almost a factor of 5, depending on the {alpha}/{beta} ratios of the normal and target tissue. This ranges from a factor of 2 less than the isoeffective dose of a similar proton treatment to a factor of 2 greater. Conclusions: No single ion is optimal for all treatment scenarios. The heavier ions are superior in cases in which the {alpha}/{beta} ratio of the target tissue is low and the {alpha}/{beta} ratio of normal tissue is high, and protons are superior in the opposite circumstances. Lithium and beryllium appear to offer dose advantages similar to carbon, with a considerably lower normal tissue dose when the {alpha}/{beta} ratio in the target tissue is high and the {alpha}/{beta} ratio in the normal tissue is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigations of the emittance and brightness of ion beams from an electron beam ion source of the Dresden EBIS type

We have characterized ion beams extracted from the Dresden EBIS-A, a compact room-temperature electron beam ion source (EBIS) with a permanent magnet system for electron beam compression, using a pepper-pot emittance meter. The EBIS-A is the precursor to the Dresden EBIS-SC in which the permanent magnets have been replaced by superconducting solenoids for the use of the source in high-ion-current applications such as heavy-ion cancer therapy. Beam emittance and brightness values were calculated from data sets acquired for a variety of source parameters, in leaky as well as pulsed ion extraction mode. With box shaped pulses of C{sup 4+} ions at an energy of 39 keV root mean square emittances of 1-4 mm mrad and a brightness of 10 nA mm{sup -2} mrad{sup -2} were achieved. The results meet the expectations for high quality ion beams generated by an electron beam ion source.

43 PARTICLE ACCELERATORS↗

Laser ion source with a double pulse laser system

To extend an ion beam pulse of a laser ion source, multiple laser shots could be used. To check the feasibility of this idea, we tested double laser irradiations on an iron target. When the interval of the two laser shots is longer than 10 {mu}s, the obtained ion current profile was expressed as a sum of two individual expanded laser plasmas. However, if the interval is too close, a current reduction was observed. This technique can be effectively applied to low charge state ion production.

43 PARTICLE ACCELERATORS↗

Investigation of an ion-ion hybrid Alfven wave resonator

A theoretical and experimental investigation is made of a wave resonator based on the concept of wave reflection along the confinement magnetic field at a spatial location where the wave frequency matches the local value of the ion-ion hybrid frequency. Such a situation can be realized by shear Alfven waves in a magnetized plasma with two ion species because this mode has zero parallel group velocity and experiences a cut-off at the ion-ion hybrid frequency. Since the ion-ion hybrid frequency is proportional to the magnetic field, it is expected that a magnetic well configuration in a two-ion plasma can result in an Alfven wave resonator. Such a concept has been proposed in various space plasma studies and could have relevance to mirror and tokamak fusion devices. This study demonstrates such a resonator in a controlled laboratory experiment using a H{sup +}-He{sup +} mixture. The resonator response is investigated by launching monochromatic waves and impulses from a magnetic loop antenna. The observed frequency spectra are found to agree with predictions of a theoretical model of trapped eigenmodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A double-plasma source of continuous bipolar ion-ion beam

A double-plasma source capable of the generation of a continuous bipolar ion-ion beam is described. The quasi-neutral ion-ion flow to an extraction electrode is formed in the system containing primary inductively coupled plasma separated from a secondary plasma by an electrostatic grid-type filter. The total current of each ion species to the 250 mm diameter extraction electrode is about 80 mA; the electron current does not exceed 30% of the ion current. Method of positive/negative ion current ratio control is proposed, allowing the ion currents ratio variation in wide range.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operation of Lanzhou all permanent electron cyclotron resonance ion source No. 2 on 320 kV platform with highly charged ions

The 320 kV platform for multi-discipline research with highly charged ions is a heavy ion beam acceleration instrument developed by Institute of Modern Physics, which is dedicated to basic scientific researches such as plasma, atom, material physics, and astrophysics, etc. The platform has delivered ion beams of 400 species for 36 000 h. The average operation time is around 5000 h/year. With the beams provided by the platform, lots of outstanding progresses were made in various research fields. The ion source of the platform is an all-permanent magnet electron cyclotron resonance ion source, LAPECR2 (Lanzhou All Permanent ECR ion source No. 2). The maximum axial magnetic fields are 1.28 T at injection and 1.07 T at extraction, and the radial magnetic field is up to 1.21 T at the inner wall of the plasma chamber. The ion source is capable to produce low, medium, and high charge state gaseous and metallic ion beams, such as H{sup +}, {sup 40}Ar{sup 8+}, {sup 129}Xe{sup 30+}, {sup 209}Bi{sup 33+}, etc. This paper will present the latest result of LAPECR2 and the routine operation status for the high voltage platform.

43 PARTICLE ACCELERATORS↗

Ion Generation Using Frozen Xenon Target for Laser Ion Source

A frozen laser target that is in the gaseous phase at room temperature is advantageous for a laser ion source because it can avoid the accumulation of damage from laser irradiation by regeneration of the target surface by additional gas freezing. In this study, the possibility of forming a xenon ion beam with a current sufficient for heavy-ion inertial fusion (HIF) was investigated. The relationship between the frozen target growth and resulting ion current was analyzed to determine the optimal condition of laser irradiation that ensures stable supply of ion beams for a long time. A frozen target of xenon was formed on a mount cooled to 20 K using a Gifford McMahon cryocooler, and plasma was generated using a Nd:YAG laser. Here, the results showed that it is possible to supply a sufficient ion current for application of singly charged ions as a driver for HIF. Additionally, it was indicated that the xenon responsible for forming the plasma existed only at a certain depth from the target surface. The results imply that it is possible to obtain a stable ion supply for a long time by irradiating the target with a laser after the frozen xenon grows to a sufficient thickness.

43 PARTICLE ACCELERATORS↗

Analysis of the Ion Conversion Mechanisms in the Effluent of Atmospheric Pressure Plasma Jets in Ar with Admixtures of O 2 , H 2 O and Air

Ionic species in atmospheric pressure plasma jets (APPJs) play an important role in plasmasurface and plasma-liquid interactions, nonetheless, they have not received the same attention as their neutral reactive species counterparts. In this work, a molecular beam mass spectrometer (MBMS) was used to characterize the ion compositions in the effluent of an APPJ operating in ambient air for different feed gases including Ar + O 2 , Ar + air and Ar + H 2 O mixtures inspired by gas compositions used for biomedical applications. Changes in compositions of positive and negative ions as a function of nozzle-to-substrate distance along the plasma plume were analyzed and compared with a pseudo-1D plug flow model. Positive and negative ions were detected up to distances of 12 mm from the visible plasma plume tip. The measurements enable to follow the ion conversion pathways in the effluent of the APPJs as a function of distance from the nozzle. The trends in ion yield obtained from a pseudo-1D plug flow model showed generally a good agreement with the experimentally observed trends after addition of ionic reactions to the previously reported reaction set but also some distinctive differences were observed. The dominant positive ions in the far effluent are water ion clusters, the most stable ion for all gas mixtures investigated, while a large variety of negative ions was found for different gas mixtures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of fast-ion losses measured in MAST-U via infrared thermography and a Fast Ion Loss Detector

Fast-ion losses need to be monitored to avoid damage to plasma facing components. In existing experimental devices, the scintillator-based fast-ion loss detector (FILD) is the most advanced diagnostic for measuring fast-ion losses. However, FILDs provide only local information about the losses. Infrared (IR) thermography can be used as a complementary tool for more global monitoring of the deposition of fast-ion losses on the wall, at the expense of no velocity-space resolution. IR cameras measure the temperature of the plasma facing components. This measurement, determined by a combined effect of the thermal plasma, radiation, neutrons and fast-ion losses, can be decomposed to infer the fast-ion load on the tokamak wall. In this manuscript, a workflow to estimate fast-ion losses via IR thermography is applied to the MAST-U spherical tokamak, using a 1D approximation to extract the experimental heat flux on the FILD front face from IR data. To numerically estimate the different contributions to this total heat flux, the field-line tracing environment SMITER is used to calculate the thermal plasma contribution, the orbit-following Monte-Carlo code ASCOT to estimate the fast-ion losses, and bolometry measurements for the radiation. To validate the workflow, two discharges, L-mode plasmas with low MHD activity, were executed using on and off-axis beams, respectively. The experimentally and numerically estimated heat flux are of the same order of magnitude for the on-axis heated scenario, with a strong dependence of the estimated fast-ion losses contribution on the fit to the kinetic profiles used as input. This is also true for the off-axis heated scenario, where the total numerically estimated heat flux is 2.1 or 1.3 times higher than the maximum experimentally estimated heat flux, depending on the ASCOT input used.

FILD↗