Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ion source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

Investigating Covalent Bonding in f-elements using Gas-phase Ion Chemistry

Introduction In the reprocessing of f-elements present in used nuclear fuels, a variety of diglycolamides (DGA’s) are used as extractants for actinide partitioning. In particular, the Actinide-Lanthanide Separation (ALSEP) process typically utilizes either the N,N,N’,N’-tetraoctyl diglycolamide (TODGA) or N,N,N',N'-tetra-2-ethylhexyl diglycolamide (T2EHDGA) extractant ligands following the partitioning of uranium and plutonium from used nuclear fuel. To better understand fundamental interactions in these processes, covalent bonding of several f-elements with diglycolamides, primarily TODGA, is investigated in the gas phase using nanospray ionization and a quadrupole time-of-flight mass spectrometer. Further, analysis of the identity and relative strength of the cluster is enabled by MS2 isolation and collision induced dissociation. Methods Metal ion cluster analysis was completed using a Bruker mircOTOF-Q II quadrupole time-of-flight mass spectrometer equipped with a CaptiveSpray nanospray ion source. Metal:ligand solutions were prepared as 30 µM europium nitrate, samarium nitrate, cerium nitrate, or holmium nitrate and 3 µM DGA in acetonitrile or a 50:50 mixture of acetonitrile: isopropanol. Cluster mass spectra and collision-induced dissociation experiments were conducted in positive mode. Preliminary data To examine the patterns and relative strength of lanthanide: DGA interactions, MS2 experiments were completed with each lanthanide species listed above. Preliminary analyses of samarium and europium TODGA clusters suggest several combinations of TODGA and nitrate forming. The samarium cluster experiments yielded Sm(TODGA)x clusters with a samarium:TODGA ratio of up to 1:7 able to be isolated and evidence of greater ratios present in the mass spectrum. This is surprising, as metal clusters are not expected to have a coordination space able to accommodate this many ligands as large as TODGA. MS2 experiments show that, at higher ratios and with sufficient collision energy, entire TODGA ligands are removed instead of being fragmented. These experiments show that a lower collision energy is required to remove ligands as the number of bound TODGA’s increases, suggesting that in larger clusters, ligands are more delicately complexed to the metal. In addition to Sm(TODGA)x, several clusters were observed with nitrate ions bound to the metal in addition to TODGA. With a single nitrate ion, clusters with up to six TODGA’s were able to be isolated. In a similar pattern to the samarium clusters with only TODGA, less collision energy is required to eliminate one or more TODGA’s with increasing size. MS2 experiments suggest clusters with one nitrate appear to be of an equivalent or greater stability to clusters which replace the nitrate with a TODGA, as more collision energy is required to remove a TODGA ligand. These species with one nitrate are also in a higher abundance than the equivalent TODGA only cluster. With two nitrate ions, only clusters with a single TODGA were able to be isolated. Analogous europium experiments resulted in very similar clusters. Ratios of up to 1:7 Eu:TODGA were able to be isolated, and clusters with one nitrate and up to five TODGAs were isolated. In clusters with two nitrate ions, one or two TODGA’s could also be bound to the metal. MS2 experiments suggested, similarly to samarium, that larger clusters required less collision energy to eliminate TODGA. Europium clusters with one nitrate are in greater abundance and are stronger than the equivalent cluster which replaces the nitrate with TODGA. Similar analysis with cerium and holmium is ongoing, as well as analysis with other DGA ligands to compare relative strengths of the lanthanide metals with various extractant ligands.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Commissioning Status of the Linac for the Facility for Rare Isotope Beams

The Facility for Rare Isotope Beams will be completed in late 2021. Here, we report here on the current efforts to commission the first stages of the 200-MeV/u superconducting, continuous wave heavy-ion linac. The statuses of the cryogenic plant and its distribution system, the accelerator cryomodule commissioning and operations, the ion source and front end transport development, the radio-frequency quadrupole commissioning, and then beam dynamics development to support high-power operation are reviewed. Plans for commissioning the remainder of the linac systems are presented.

43 PARTICLE ACCELERATORS↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ion Manipulation from Liquid Xe to Vacuum: Ba-Tagging for a nEXO Upgrade and Future 0 νββ Experiments

Neutrinoless double beta decay (0𝜈𝛽𝛽) provides a way to probe physics beyond the Standard Model of particle physics. The upcoming nEXO experiment will search for 0𝜈𝛽𝛽 decay in 136 Xe with a projected half-life sensitivity exceeding 10 28 years at the 90% confidence level using a liquid xenon (LXe) Time Projection Chamber (TPC) filled with 5 tonnes of Xe enriched to ∼90% in the 𝛽𝛽-decaying isotope 136 Xe. In parallel, a potential future upgrade to nEXO is being investigated with the aim to further suppress radioactive backgrounds and to confirm 𝛽𝛽-decay events. This technique, known as Ba-tagging, comprises extracting and identifying the 𝛽𝛽-decay daughter 136 Ba ion. One tagging approach being pursued involves extracting a small volume of LXe in the vicinity of a potential 𝛽𝛽-decay using a capillary tube and facilitating a liquid-to-gas phase transition by heating the capillary exit. The Ba ion is then separated from the accompanying Xe gas using a radio-frequency (RF) carpet and RF funnel, conclusively identifying the ion as 136 Ba via laser-fluorescence spectroscopy and mass spectrometry. Simultaneously, an accelerator-driven Ba ion source is being developed to validate and optimize this technique. The motivation for the project, the development of the different aspects, along with the current status and results, are discussed here.

a-tagging↗

An international laboratory comparison of dissolved organic matter composition by high resolution mass spectrometry: Are we getting the same answer?

Since the first detailed compositional analysis of dissolved organic matter (DOM) in 1995, high resolution mass spectrometry (HRMS) has become a vital tool for DOM characterization. While the upward trend in HRMS for molecular level analysis of DOM continues, so do the challenges of data comparison and interpretation between laboratories operating instruments of differing performance and user operating conditions. It is therefore essential that the community establishes whether data and trends can be compared robustly between research groups. To this end, 4 identically prepared DOM samples were each studied by 16 laboratories, representing 17 commercially-purchased instruments located across 8 countries, using positive- and negative-mode electrospray ionization (ESI) HRMS analysis. Despite the widely reported sensitivity of ESI experiments to sample matrix, preparation, ion source operation and instrument tuning parameters, the instruments used in this study showed relatively low variability between results for the same samples, particularly H/C and AI metrics. The variation in O/C and m/z metrics was relatively higher, although z-score graphs and %BCD demonstrated that the relative difference in general chemical composition between samples was the same for each instrument included in the study. As such, these metrics can be used for fingerprinting of DOM samples and as a benchmark for quality control in participating laboratories, with future strides in environmental science building upon these efforts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Complete resolution across the neodymium/samarium isotopic envelope with a liquid sampling‐atmospheric pressure glow discharge — Orbitrap mass spectrometer

Rationale Nd and Sm isotope ratios play an important role in geological dating and as nuclear forensic signatures; however, the overlap of the respective 144, 148, 150 Nd/Sm isobars requires prior separations to be performed before analysis on typical MS platforms. The work presented here overcomes these isobaric interferences using ultrahigh‐mass resolution to alleviate interference without prior chemical separations. Methods A liquid sampling‐atmospheric pressure glow discharge ion source was coupled to a standard, QExactive Focus Orbitrap mass spectrometer, providing a mass resolution of ~80 k. A Spectroswiss FTMS booster X2 data acquisition package was used to collect extended transients, providing much higher mass resolution; ~230 k and ~600 k are employed here for Nd and Sm isotopes. Results While the standard Orbitrap resolution is far greater than typical “atomic” MS platforms, it was insufficient to alleviate all isobars. The use of a resolution of ~230 k resulted in baseline separation across the entire isotopic envelope for both Nd and Sm. Isotope ratios obtained from Nd:Sm mixtures using high‐resolution were equivalent to those found for individual‐element solutions, while isotope ratios obtained at a resolution of ~80 k (standard for the OEM data system) showed large deviations. Conclusions Use of ultrahigh‐resolution is an attractive alternative to extensive chemical separations to alleviate severe isobaric interferences. Sufficient mass resolution greatly reduces/eliminates the need for sample manipulations (separations) before analysis while reducing costs and total analysis times.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High efficiency laser resonance ionization of plutonium

Three-step resonance photoionization spectra of plutonium have been studied with Ti:Sapphire lasers for the development of efficient laser ionization schemes for ultra-trace analysis of Pu isotopes by resonance ionization mass spectrometry. We observed eighteen intermediate excited states of even parity in the energy range 35568–36701 cm -1 , thirteen of them have not been previously documented, and a larger number of high-lying excited states and autoionizing states of odd-parity between 48238 and 49510 cm -1 . Three-color, three-photon ionization schemes via six intermediate states were evaluated under similar ion source operating conditions. This led to a highly efficient three-step scheme with an overall ionization efficiency of 51.1±1.3%, which is an order of magnitude improvement over the previously reported ionization efficiency for Pu.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental and computational investigation of the bond energy of thorium dicarbonyl cation and theoretical elucidation of its isomerization mechanism to the thermodynamically most stable isomer, thorium oxide ketenylidene cation, OTh + CCO

Collision-induced dissociation (CID) of [Th,2C,2O] + with Xe is performed using a guided ion beam tandem mass spectrometer (GIBMS). The only products observed are ThCO + and Th + by sequential loss of CO ligands. The experimental findings and theoretical calculations support that the structure of [Th,2C,2O] + is the bent homoleptic thorium dicarbonyl cation, Th + (CO) 2 , having quartet spin, which is both thermodynamically and kinetically stable enough in the gas phase to be observed in our GIBMS instrument. Analysis of the kinetic energy-dependent cross sections for this CID reaction yields the first experimental determination of the bond dissociation energy (BDE) of (CO)Th + –CO at 0 K as 1.05 ± 0.09 eV. A theoretical BDE calculated at the CCSD(T) level with cc-pVXZ (X = T and Q) basis sets and a complete basis set (CBS) extrapolation is in very good agreement with the experimental result. Although the doublet spin bent thorium oxide ketenylidene cation, OTh + CCO, is calculated to be the most thermodynamically stable structure, it is not observed in our experiment where [Th,2C,2O] + is formed by association of Th + and CO in a direct current discharge flow tube (DC/FT) ion source. Potential energy profiles of both quartet and doublet spin are constructed to elucidate the isomerization mechanism of Th + (CO) 2 to OTh + CCO. The failure to observe OTh + CCO is attributed to a barrier associated with C–C bond formation, which makes OTh + CCO kinetically inaccessible under our experimental conditions. Furthermore, chemical bonding patterns in low-lying states of linear and bent Th + (CO) 2 and OTh + CCO isomers are also investigated.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An uncertainty-aware strategy for plasma mechanism reduction with directed weighted graphs

In this work, we present a framework for the analysis and reduction of plasma mechanisms by means of weighted directed graphs, in which reactions and species are both treated as nodes. The methodology consists of two distinct analyses. The first, which is qualitative, relies on graph spatializations via force-directed algorithms to discover the predominant global patterns in the chemical model. The second ranks the reactions based on their shortest paths' lengths from/to the species of interest and their relative contributions to the power balance. Further, this quantitative investigation enables a strategy for mechanism reduction that is fully automatized, as it does not require any expert knowledge, highly effective, as it generates reduced mechanisms that are highly accurate while relying on a small number of processes, and easily interpretable, as the algorithm justifies the importance of the retained reactions by outputting their related chemical pathways. Additionally, the work proposes a methodology extension that employs ensembles of graphs to improve the robustness of the reduced mechanism to reaction parameter uncertainties. The approach, here tested for steady-state predictions of a plasma system characterizing negative hydrogen ion sources, is general and can be used in a wide variety of applications outside the particular nuclear fusion context demonstrated in this work.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Investigation of divertor detachment induced through neon seeding and density ramp on HL-3

A new self-consistent 1D scrape-off layer model has been recently developed in BOUT++ framework, named SD1D, which includes equations for various particle species (e.g. main plasma, neutrals and impurities) and couples open databases like ADAS and AMJUEL. It is able to quickly and effectively simulate divertor detachment experiments. In this work, a typical detachment experiment (shot #6270) on HL-3 with neon seeding is simulated using the SD1D code. It is found that the target electron temperature and the target ion saturation current in the simulations are consistent with experimental results measured by Langmuir probes on the target plate. The variation of D α radiation intensity in the divertor is qualitatively similar to the measured D α signal. Following the experimental validations, different upstream densities are set in the simulations to study the impurity distribution under different plasma density conditions. It is found that increasing upstream density can be helpful for the control of the neon radiation front (closer to the target). In this work we also compare two detachment regimes in simulations. Based on the same initial experimental parameters (shot #6270) on HL-3, a scan of upstream density and a scan of neon seeding rate are carried out respectively. It is found that the role of atomic and molecular processes is different in the two detachment regimes. The current density roll-over is ascribed to a drop in the divertor ion source, and the variation of D α radiation intensity via different excitation channels is associated with the relevant collisional reaction sources.

BOUT++↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

Nanoscale dynamics during self-organized ion beam patterning of Si. II. Kr + bombardment

Understanding the self-organized ion beam nanopatterning of elemental semiconductors, particularly silicon, is of intrinsic scientific and technological interest. This is the second component of a two-part coherent x-ray scattering and x-ray photon correlation spectroscopy (XPCS) investigation of the kinetics and fluctuation dynamics of nanoscale ripple development on silicon during 1 keV Ar + (part I) and Kr + bombardment at 65° polar angle. Here it is found that the ion-enhanced viscous flow relaxation is essentially equal for Kr + -induced patterning as previously found for Ar + patterning despite the difference in ion masses. However, the magnitude of the surface curvature-dependent roughening rate in the early-stage kinetics is larger for Kr + than for Ar + , consistent with expectations that the heavier ion gives an increased mass redistributive contribution to the initial surface instability. As with the Ar + case, fluctuation dynamics in the late stage show a peak in correlation times at the length scale corresponding to the dominant structural feature on the surface—the ripples. Finally, it is shown that speckle motion during the surface evolution can be analyzed to determine spatial inhomogeneities in erosion rate and ripple velocity. This allows the direction and speed of ripple motion to be measured in a real time experiment. In the present case, ripple motion is found to be into the projected direction of the ion source, in contrast to expectations from an existing sputter erosion driven model with parameters derived from binary collision approximation simulations.

36 MATERIALS SCIENCE↗

First direct 7 Be electron-capture $\mathrm{Q}$-value measurement toward high-precision searches for neutrino physics beyond the Standard Model

Here, we report the first direct measurement of the nuclear electron-capture (EC) decay Q value of 7 Be → 7 Li via high-precision Penning trap mass spectrometry (PTMS). This was performed using the LEBIT Penning trap located at the National Superconducting Cyclotron Laboratory/Facility for Rare Isotope Beams (NSCL/FRIB) using the newly commissioned Batch-Mode Ion-Source (BMIS) to deliver the unstable 7 Be + samples. With a measured value of Q EC = 861.963(23) keV, this result is three times more precise than any previous determination of this quantity. This improved precision and accuracy of the 7 Be EC decay Q value is critical for ongoing experiments that measure the recoiling nucleus in this system as a signature to search for beyond the Standard Model (BSM) neutrino physics using 7 Be-doped superconducting sensors. This experiment has extended LEBIT capabilities, using the first low-energy beam delivered by BMIS at FRIB for PTMS, as well as measuring the lightest-mass isotopes so far with LEBIT.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of 3He Solenoid Power Supply at BNL

The design of the 3He solenoid power supply at Brookhaven National Laboratory (BNL) has been completed and construction is underway. The power supply is an upgrade of the existing Electron Beam Ion Source (EBIS) solenoid power supply and thus can be used as an operational spare. It is also capable of driving a solenoid magnet that rotates the 3He spin direction. The design is based on the original EBIS solenoid power supply, incorporating bipolar output and short circuit protection features to address the expanded requirements for spin rotation. The output current is a half sine wave of 13ms duration at the repetition rate of 5Hz, with the amplitude of 1900A. This paper will discuss the design and construction status of the 3He solenoid power supply.

Tan, Yugang↗

Ion-beam-assisted growth of cesium-antimonide photocathodes

We report on the novel use of a Cs+ ion gun for an ion-beam-assisted molecular-beam-epitaxy (IBA-MBE) method to sequentially deposit Cs-Sb cathodes on room temperature substrates as opposed to the standard technique of thermal evaporation on elevated-temperature substrates. The details of the ultrahigh-vacuum chamber, the Cs+ ion source, and the growth technique are elaborated. The final quantum efficiency (QE) is reasonably good for Cs-Sb cathodes grown on two different substrates—Si (100) and strontium titanate—and is comparable to the QE of cathodes grown using thermal sources. This suggests that IBA-MBE could be a viable alternative to grow alkali-antimonides without substrate heating, paving the way for the growth of epitaxial alkali-antimonides in a more reproducible fashion, which may help improve the efficiency of photon detectors and accelerator applications that use alkali-antimonides as electron sources.

Engineering↗

Beam Dynamics Studies at the PIP-II Injector Test Facility

A series of beam dynamic studies were performed in 2020-2021 at the PIP-II Injector Test Facility (PIP2IT) that has been built to validate the concept of the front-end of the PIP-II linac being constructed at Fermilab. PIP2IT is comprised of a 30-keV H- ion source, a 2 m-long Low Energy Beam Transport (LEBT), a 2.1- MeV CW RFQ, followed by a 10-m Medium Energy Beam Transport (MEBT), 2 cryomodules accelerating the beam to 16 MeV and a High-Energy Beam Transport (HEBT) bringing the beam to a dump. This paper presents beam dynamics - related measurements performed at PIP2IT such as the Twiss parameters with Allison scanners, beam envelopes along the injector, and transverse and longitudinal rms emittance reconstruction. These measurements are compared with predictions from the beam dynamics code Tracewin.

43 PARTICLE ACCELERATORS↗