Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “integration cost”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Evaluating Utility Costs Savings and Resilience: A Case Study in Port Arthur, Texas

This study evaluates the techno-economic feasibility of integrating solar photovoltaics (PV), battery energy storage systems (BESS), and generators to enhance both cost savings and resilience in critical community facilities in Port Arthur, Texas. Using NREL's REopt model, we analyze four facilities: the Golden Triangle Empowerment Center (GTEC), Lamar State College (LSC), Port Arthur Independent School District (PAISD), and Port Arthur Transit (PAT). A key aspect of the analysis is the incorporation of the Value of Lost Load (VoLL) and microgrid upgrade costs to assess the hidden value of resilience during grid outages. While standalone PV scenarios show moderate cost reductions and a 10-15% decrease in CO2 emissions, the inclusion of resilience measures with BESS and generators significantly increases system costs. However, the hidden value of resilience - quantified through avoided outage costs - leads to a substantial improvement in financial outcomes, resulting in positive Net Present Value (NPV) at many sites. The study demonstrates that resilient solar and storage systems offer both economic and resilience benefits, particularly for underserved communities, by balancing energy savings and enhanced operational continuity during outages.

14 SOLAR ENERGY↗

Nuclear fuel irradiation testbed for nuclear security applications

The nuclear security community has long been interested in the identification and quantification of nuclear material signatures to understand a material’s provenance, use, and ultimate application. New forensics signatures and methods intended for non-traditional or advanced nuclear fuel applications require fuel irradiation experiments to demonstrate viability and validity. Integral fuel irradiations have historically required significant costs and long timelines to design, irradiate, and characterize. This paper describes how a recently developed nuclear fuel irradiation testbed can be used to provide a low cost, rapid turnaround, modular test environment for irradiation and evaluation of nuclear fuel specimens for nuclear security applications. The irradiation testbed houses six small ‘MiniFuel’ samples within hermetically sealed capsules inside targets that can be removed in between each ∼25-day operating cycle of the High Flux Isotope Reactor (HFIR). As many as nine targets can be irradiated using a single irradiation position (reflector region) in HFIR, allowing for varying irradiation temperatures and burnups. A suite of hot cell capabilities have been established to perform post-irradiation examination for measuring performance (e.g., fuel swelling, fission gas release) and facilitating experiment disassembly for subsequent property measurements, microstructural analysis, or chemical assay. This new testbed allows fuel irradiations to be conducted on an accelerated timeframe to enable rapid proof of concept testing and to provide reference material for nuclear fuel security applications. Recent applications using this testbed include the testing of isotopic taggants in UO 2 fuel (intentional forensics), testing of U-10Mo fuel for down-conversion of highly enriched uranium–fueled reactors, and the production of irradiated UO 2 fuel material for signature analysis of its isotopic composition (plutonium, fission gases, etc.).

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Development of Building Design Optimization Methodology: Residential Building Applications

Building design optimization is a highly complex problem, requiring long computational running processes because of the many options that exist when a building is being designed. This paper introduces an integrated approach through which to perform this optimization within an acceptable time frame. The approach includes the methods of variable selection, model simplification, and a sequential optimization process. Using singular value decomposition, a large number of design variables is reduced to a smaller subset that can be solved more quickly through the optimization algorithm. To expedite the variable selection process, a modeling approach that quickly simulates annual energy consumption was developed to replace full annual energy simulations. The developed methodology was applied to two residential buildings in the US, and the results are discussed herein. To assess the accuracy of the integrated optimization methodology, the optimized life cycle costs are compaa variables demonstrating the strongest contributions in the optimization study were identified. The proposed methodology significantly shortened the time requirements for the optimization processes of the two case studies by 74% and 84%; the optimized life cycle costs were within 0.05% and 0.06%, respectively, of the optimum point.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stream water sourcing from high-elevation snowpack inferred from stable isotopes of water: a novel application of d-excess values

About 80 % of the precipitation at the Colorado River's headwaters is snow, and the resulting snowmelt-driven hydrograph is a crucial water source for about 40 million people. Snowmelt from alpine and subalpine snowpack contributes substantially to groundwater recharge and river flow. However, the dynamics of snowmelt progression are not well understood because observations of the high-elevation snowpack are difficult due to challenging access in complex mountainous terrain as well as the cost and labor intensity of currently available methods. We present a novel approach to infer the processes and dynamics of high-elevation snowmelt contributions predicated upon stable hydrogen and oxygen isotope ratios observed in streamflow. We show that deuterium-excess (d-excess) values of stream water could serve as a comparatively cost-effective proxy for a catchment-integrated signal of high-elevation snowmelt contributions to catchment runoff. We sampled stable hydrogen and oxygen isotope ratios of the precipitation, snowpack, and stream water in the East River, a headwater catchment of the Colorado River, and the stream water of larger catchments at sites on the Gunnison River and Colorado River. The d-excess of snowpack increased with elevation; the upper subalpine and alpine snowpack (> 3200 m) had substantially higher d-excess compared to lower elevations (< 3200 m) in the study area. The d-excess values of stream water reflected this because d-excess values increased as the higher-elevation snowpack contributed more to stream water generation later in the snowmelt/runoff season. End-member mixing analyses based on the d-excess data showed that the share of high-elevation snowmelt contributions within the snowmelt hydrograph was on average 44 % and generally increased during melt period progression, up to 70 %. The observed pattern was consistent during 6 years for the East River, and a similar relation was found for the larger catchments on the Gunnison and Colorado rivers. High-elevation snowpack contributions were found to be higher for years with lower snowpack and warmer spring temperatures. Thus, we conclude that the d-excess of stream water is a viable proxy to observe changes in high-elevation snowmelt contributions in catchments at various scales. Inter-catchment comparisons and temporal trends of the d-excess of stream water could therefore serve as a catchment-integrated measure to monitor if mountain systems rely on high-elevation water inputs more during snow drought compared to years of average snowpack depths.

54 ENVIRONMENTAL SCIENCES↗

Modeling Wind-Hydrogen System and Analyzing Curtailment

Low-cost green hydrogen can be achieved by integrating utility-scale wind farms to an electrolyzer. The power produced by a wind farm depends on spatial and temporal changes in the wind, and this variability can affect the electrolyzer's performance. This study examines the trade-offs between two electrolyzer configurations: a large centralized electrolyzer connected to the wind farm versus several smaller distributed electrolyzers connected directly to each wind turbine. The results show that a centralized configuration generates more hydrogen because turbines that are waked and produce less power are compensated but other un-waked turbines.

electrolyzer↗

Unsupervised Learning for Equitable DER Control: Preprint

In the context of managing distributed energy resources (DERs) within distribution networks (DNs), this work focuses on the task of developing local controllers. We propose an unsupervised learning framework to train functions that can closely approximate optimal power flow (OPF) solutions. The primary aim is to establish specific conditions under which these learned functions can collectively guide the network towards desired configurations asymptotically, leveraging an incremental control approach. The flexibility of the proposed methodology allows to integrate fairness-driven components into the cost function associated with the OPF problem. This addition seeks to mitigate power curtailment disparities among DERs, thereby promoting equitable power injections across the network. To demonstrate the effectiveness of the proposed approach, power flow simulations are conducted using the IEEE 37-bus feeder. The findings not only showcase the guaranteed system stability but also underscore its improved overall performance.

asymptotic stability↗

Demonstration of the carbon capture with building make-up air unit

Building-integrated carbon capture technology has the potential to reduce the cost of CO 2 capture while improving indoor air quality (IAQ). To promote the adoption of CO 2 capture in a building environment, this study investigated the possibility of integrating carbon capture technology with an existing rooftop make-up air unit (MAU) system to trap CO 2 . Here, in this study, a modular compact CO 2 capture system containing amine-functionalized polymer fibers was examined. The system, which was installed at the exhaust of the MAU, captures CO 2 before it leaves the building to enter the atmosphere as a greenhouse gas. The demonstrated average amount of CO 2 captured was 1.1–1.4 mmol/g of adsorbent material. Techno-economic analysis (TEA) was further performed on the CO 2 capture system, considering material costs, energy costs, as well as transportation and regeneration costs. These results were then used to estimate the levelized cost per ton CO 2 captured (LCOC). To achieve LCOC below $\$$100/t-CO 2 , adsorbents should have working capacities of 4.9 t and 3 t-CO 2 /year for 5 years and 10 years of operation, respectively. In summary, this study highlights a viable path toward the decarbonization of the commercial buildings sector and provides quantitative performance and economic insight on the suitability of building-integrated carbon capture technology.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

Predicting Switchgrass Biomass Yields Using a Spectral Vegetation Index Derived from Multispectral Satellite Imagery

Successful scaling of perennial bioenergy crop production requires a landscape design that optimizes the benefits of finite lands for people, communities, and environments. Utilizing marginal areas is the key to sustainable bioenergy crop production (Ssegane et al., 2015, 2016). Marginal areas are often small-sized lands and unevenly distributed across the agricultural landscape (Ssegane et al., 2016); thus, a systematic, semi-automated remote sensing method is needed as an effective means of estimating bioenergy crop yields across landscapes. Argonne National Laboratory (Argonne) is currently developing a tool, Scaling Up Perennial Bioenergy Economics and Ecosystem Services Tool (SUPERBEEST), to identify marginal agricultural lands and quantify environmental and economic effects of perennial bioenergy crop production systems. The tool aims to provide users a path to foster the sustainable and productive integration of bioenergy crops in the Midwestern agricultural landscape. Reliable, cost-effective, and timely estimation of bioenergy crop yields using remote sensing would help calculate and track the success of integrated bioenergy crops in the landscape for those communities. Argonne previously conducted feasibility studies for estimating biomass yields for bioenergy feedstock, corn and perennial grass using spectral vegetation indices (SVIs)1 derived from optical imagery (Hamada et al., 2015, 2021). In both studies, SVIs, more specifically those sensitive to plant chlorophyll or nitrogen contents, showed potential for estimating or predicting biomass yields with a correlation of determination (R2) ranging from 0.54 to 0.96, indicating a value for further investigation as a viable means of quantifying bioenergy feedstock production across large landscapes. Thus, the goal of this study is to evaluate the feasibility of use of SVIs as a means of estimating or predicting switchgrass biomass yields at harvest using publicly available multispectral satellite imagery. The feasibility analysis was performed using four study areas of mature switchgrass located in Virginia. Objectives are to (1) examine the SVIs and establish their relationships with switchgrass biomass yields at harvest, (2) develop a parsimonious image processing model for predicting at-harvest yields by applying the relationships with the most promising spectral index and (3) map switchgrass yields predicted by the image processing model across the study sites. The calibration to field data will rely on switchgrass biomass yields determined by the baling method, representing a potential challenge to the analysis but an important practical aspect for future applications. With this research design, the study aimed to gain insights into enabling remote sensing-based estimation of bioenergy crop yields in a reliable, cost- effective, and timely manner across large, heterogeneous landscapes.

09 BIOMASS FUELS↗

Intersections of Disadvantaged Communities and Renewable Energy Potential: Data Set and Analysis to Inform Equitable Investment Prioritization in the United States

Renewable energy development can bolster local economies through job creation, local tax revenues, and reduced energy costs; however, communities most in need of economic development and employment opportunities often see lower levels of renewable energy deployment. We sought to identify areas where disadvantaged community indicators and high generation potential from cost-effective renewable energy opportunities intersect and deployment could lead to economic development and job creation. This presentation will highlight several of our findings. This research and the associated county-level data set are intended to inform national- and state-level energy-related assistance programs, economic development efforts, and infrastructure programs seeking to prioritize investments in disadvantaged communities.

community energy planning↗

Ten questions concerning low-cost indoor air quality sensors: Perspectives from research and practice

Low-cost indoor air quality (IAQ) sensors are increasingly being used in homes and commercial and public buildings, driven by growing concerns about the impact of air on health, cognitive performance, and occupant wellbeing. These sensors offer a potentially transformative opportunity to increase spatial and temporal coverage of IAQ monitoring at a fraction of the cost of conventional reference instruments. However, their widespread use raises questions around accuracy, calibration, placement, data handling and interpretation, and integration into existing standards and workflows. This paper presents ten critical questions concerning the use of low-cost IAQ sensors in buildings, drawing on the latest empirical research, field deployments, and emerging practice. It discusses potential frameworks for deployment and evaluation, examines current sensor capabilities for measuring common pollutants, identifies methodological gaps in validation and uncertainty quantification, and outlines the extent to which existing IAQ standards can accommodate sensor-based evidence. The paper also explores how monitoring needs and deployment models vary by building type, the potential of real-time IAQ data to support building operations, and the ethical and legal implications of widespread sensor use. While significant challenges remain in ensuring data quality and building stakeholder trust, new applications are emerging through open data initiatives and advances in analytics and visualization. As the technology, science, and standards co-evolve, low-cost IAQ sensors are poised to become integral to routine building operation, building science, and environmental health research.

Parkinson, Thomas↗

Adopting occupancy-based HVAC controls in commercial building energy codes: Analysis of cost-effectiveness and decarbonization potential

Recent research has shown the energy-saving potential of occupancy-based HVAC controls (OBCs) in commercial buildings. However, building energy codes have not fully adopted this technology. This study aims to evaluate the cost-effectiveness and decarbonization benefits of OBCs and provide guidance for integrating occupancy sensors into building energy code development. To this end, a parametric simulation using EnergyPlus and a nationwide cost-effectiveness analysis are carried out considering three building types and 40 representative cities in the U.S. Here, the findings reveal that the current cost-effectiveness performance of OBCs is limited due to the high cost of occupancy sensors. However, incorporating the societal cost of carbon factor in future energy and environmental policy could greatly enhance the actual cost-effectiveness performance. Besides, a reduction in the cost of occupancy sensors to approximately 60% of the current price level could also greatly shorten the discounted payback period of OBCs. Additionally, OBCs demonstrate significant potential in building decarbonization, with potential CO 2 emissions savings of more than 5.56 million metric tons across the three building types and 40 selected cities. Finally, policy implications are provided to guide the incorporation of occupancy-based HVAC controls in future energy codes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technoeconomic Analysis of the Electrochemically Mediated Amine Regeneration CO 2 Capture Process

The electrochemically mediated amine regeneration (EMAR) process presents an alternative route to the conventional thermal amine regeneration for carbon capture from a flue gas source. In this study, we conducted an economic analysis on the EMAR system for postcombustion CO2 capture from a 550 MWe power plant capturing 3.1 MtCO2 annually and from a mini steel mill with annual capture close to 170 ktCO2. We followed the recommendation of the National Energy Technology Laboratory (NETL) 2010 report to estimate the cost of CO2 avoided ([$/tCO2]). Detailed cost modeling of the electrochemical separation stage was conducted. This is integrated with the entire process flowsheet (e.g., including absorber, compressor, pumps, and other auxiliary equipment). Here, we identified the membrane cost as the dominant capital cost for the electrochemical separation train. At a membrane unit price of less than 10/m2, the CO2 capture cost can be reduced to below 50/tCO2 with optimized process conditions (e.g., desorption pressure and utilization of waste heat). Improvements in process design, cell construction, and solvent formulation may lead to additional reductions in the CO2 capture cost.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamic optimization and economic evaluation of flexible heat integration in a hybrid concentrated solar power plant

Hybridization of concentrated solar power (CSP) plants provides flexibility in operation that can drastically improve the solar-to-electric (STE) efficiency and levelized cost of electricity (LCOE) relative to standalone CSP plants. Flexible heat integration (FHI) is a novel concept where the collection and integration of CSP within a power plant is modified relative to the amount of solar energy available. FHI improves the thermal efficiency of a hybrid solar tower steam Rankine cycle power plant but leads to increased pumping needs due to continuously elevated molten salt flow rates through the collection system, which can negatively impact STE efficiency. The present work is carried out to maximize the STE efficiency of a hybrid CSP plant utilizing FHI by employing a dynamic optimization framework where a genetic algorithm optimizes the operation of the plant over a given solar irradiance profile. The study concerns a plant hypothetically located in Salt Lake City, Utah. Here, the optimization results confirm the accuracy of a predictive heuristic where the preferred operation of the plant can be estimated relative to local peaks in the incident power generated by the heliostat collection field. The optimized FHI operation demonstrates a yearly STE efficiency of 13.8%, whereas the equivalent base-level hybrid and solar-only plants exhibit solar efficiencies of 13.4% and 11.2%, respectively. Economic analysis shows that FHI reduces yearly natural gas costs, leading to a $\$0.5$/MWh reduction in LCOE relative to the base-level hybrid configuration. Overall, the results show that hybrid FHI schemes exhibit economic benefits along with observed thermodynamic improvements.

14 SOLAR ENERGY↗

LED Lighting: A Global Enterprise

Focused on integrated luminaires using a 2x2 troffer as example: Understand manufacturing costs and value-add along the supply chain Investigate trade flows How can R&D investments in a product manufactured not domestically benefit a domestic economy.

domestic economy↗

An economic assessment of behind-the-meter photovoltaics paired with batteries on the Hawaiian Islands.

Due to natural variability and uncertainty, the ever-increasing penetration of solar generation in Hawaii presents challenges to power grid operators to maintain reliable system operation. Demand response (DR) has the potential to be a cost-effective tool for Hawaii to reach its aggressive renewable energy goals while maintaining the reliability of power grids. The Hawaii Public Utilities Commission has approved the Hawaiian Electric Company's revised portfolio of DR programs. The companies have released a grid services purchase agreement and subscribed an initial tranche of load into their DR programs. This paper presents innovative analytical methods and comprehensive economic assessment for distributed photovoltaics (PV) paired with battery energy storage systems (BESSs) for two new DR programs, including fast frequency response and capacity grid service. Optimal dispatch and sizing methods are proposed for the paired system considering different tariff schedules and PV compensation programs across five islands. It was found that while the best resource configuration and potential economic benefits vary with tariff structure, a BESS paired with PV can be optimally dispatched to generate multiple value streams simultaneously. Compensation from DR programs is an important value stream to help increase the cost-effectiveness of the integrated system.

Battery energy storage system↗

Battery asset management with cycle life prognosis

We report Battery Asset Management problem determines the minimum cost replacement schedules for each individual asset in a group of battery assets that operate in parallel. Battery cycle life varies under different operating conditions including temperature, depth of discharge (DOD), charge rate, etc., and a battery deteriorates due to usage, which cannot be handled by current asset management models. This paper presents a new battery asset management methodology where battery cycle life prognosis is integrated with parallel asset management to reduce lifecycle cost of the Battery Energy Storage Systems (BESS). For the battery failure time prognosis, a nonlinear physics-based battery capacity fade model is developed and incorporated in parallel asset management model to update battery capacity over time. Experiment results have shown that the developed battery asset management methodology can be conveniently used to facilitate BESS asset management decision making thereby decreasing asset lifecycle costs.

25 ENERGY STORAGE↗

The future of subsurface monitoring: AEC’s breakthroughs in CCS technology

Carbon capture and storage (CCS) has emerged as a key solution in the fight against climate change. However, for CCS to succeed, it is crucial to ensure that the sequestered CO2 stays safely trapped underground. The U.S. Department of Energy (DOE) has emphasized the need for advancements in subsurface monitoring, measurement, reporting, and verification. Aside from caprock integrity failure, the other primary failure points usually involve defective cement in the casing annulus of wellbores or plugged and abandoned wells. In addition, many energy producers (e.g., oil and gas, geothermal) and storage and disposal operators (e.g., H2 and water) must deal with the same issue. Poorly placed or degraded cement can create pathways for gas or fluid to escape from casing annuli and in plugged and abandoned or orphan wells, posing environmental risks. Yet, a reliable and cost-effective way to monitor cement and well integrity over multiple decades is still unavailable. Traditional geophysical methods like 4D seismic imaging and surface-based electromagnetic monitoring lack the resolution and accuracy for detecting these types of failures (Vasco et al., 2022; Fawad and Mondol, 2021). Wireline logging is expensive to run continuously and is obtrusive to the operation. While fiber optics can potentially be a solution, its bulkiness can significantly compromise the cement's integrity. To address these challenges, the Advanced Energy Consortium (AEC) at The University of Texas at Austin’s Bureau of Economic Geology (the Bureau) has been pioneering research in subsurface monitoring using its portfolio of distributed autonomous microfabricated sensors for harsh subsurface environments since 2008. A class of these microsensors [System on a Chip (SoC)] can be mixed in cement and permanently placed without compromising the cement column; the sensors would then communicate with each other or a data acquisition (DAQ) master node. Another class of the AEC microsensors can be fully autonomous, with rechargeable micro-batteries capable of exceeding 100°C, flash memory, and, currently, a pressure and temperature sensor. They are designed to circulate in mud, geothermal fluids, U-loops, or pipelines. They can log data into memory and are unobtrusive to operations. Our team has been working on a multi-year DOE-funded project (DE-FE0031856)—supported by $2.95M in federal funding and $0.75M in cost-matching from the AEC—to demonstrate SoC sensor utility for CO2 leakage monitoring in CCS applications. This multi-institutional collaboration developed a novel sensing architecture utilizing radiofrequency (RF) microsensors embedded within the cement sheath. These sensors detect CO2 migration and are interrogated via a Smart Casing Collar (SCC).

58 GEOSCIENCES↗