Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installed base”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Implementation of a Doppler-Free Saturation Spectroscopy (DFSS) Diagnostic for Helicon Wave Electric Field Vector Measurement in Edge Plasma in DIII-D

A laser-based technique known as Doppler-free saturation spectroscopy (DFSS) has been designed, fabricated, and installed on the DIII-D National Fusion Facility to measure the helicon wave electric field vector in the edge plasma. These experimental measurements quantify phenomena resulting in decreased current drive efficiency due to wave/edge plasma interactions. This implementation of DFSS on DIII-D is the first of its kind on a tokamak and thus presents unique engineering challenges, including integration of the system onto an existing multidiagnostic port flange without impacts to system serviceability, as well as maintaining precise laser alignment over a 2-m distance during disruptions and thermal drift of the vessel. Further, these challenges were resolved using innovative design approaches such as a novel decoupled shutter system to facilitate serviceability of the in-vessel mirror assemblies without the need for personnel vessel entry, as well as an ex-vessel piezo-mirror-based optical system for laser beam shaping and real-time steering of the measurement location. The solutions to these engineering challenges were demonstrated during the successful installation and operation of these diagnostic components during the 2022 DIII-D vent and subsequent experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Draft Environmental Impact Statement for Proposed Energy Conservation Standards for Manufactured Housing

This draft environmental impact statement (EIS) analyzes the impacts related to DOE’s proposed energy conservation standards for manufactured homes. DOE’s proposed energy conservation standards are based on the 2021 International Energy Conservation Code (IECC) and relate to the building thermal envelope; air sealing; installation of insulation; duct sealing; heating, ventilation and air conditioning (HVAC); service hot water systems; mechanical ventilation fan efficacy; and heating and cooling equipment sizing. The draft EIS evaluates DOE’s proposed action (energy conservation standards tiered based the manufacturers retail list price), alternatives to the proposed action (including energy conservation standards tiered based on size of the manufactured home and untiered standards), and a no action alternative. The draft EIS presents analysis of impacts related to (1) energy resources; (2) air resources (including greenhouse gases, climate change, ambient air quality and indoor air quality); (3) health and safety; (4) socioeconomics; and (5) environmental justice.

MacDonell, Margaret↗

Knowledge-Based Hazardous Waste Determinations for Solar Photovoltaic (PV) Modules: A Foundational Study

This report explores using "generator knowledge" to determine whether a solar photovoltaic (PV) module must be managed as hazardous waste prior to recycling or landfilling. Generator knowledge is a legal term and existing regulatory pathway for making a hazardous waste determination that has been used by other industries but is a relatively unknown option to the PV industry. In the United States, a hazardous waste determination often acts as a pre-requisite to recycle or landfill a PV module. The results of the hazardous waste determination dictate whether the PV module must be managed as hazardous waste or nonhazardous solid waste. Managing a PV module as hazardous waste requires compliance with stringent U.S. federal and state hazardous waste law. In addition to increased management costs, which can be ten times higher, legal liability for PV modules regulated as hazardous waste is also heightened with both civil and criminal penalties for noncompliance which includes making an inaccurate or faulty hazardous waste determination. The most common reason a PV module would be regulated as hazardous is if it contains a regulated metal in an amount that equals or exceeds the toxicity characteristic limits. To determine whether a PV module exhibits a hazardous characteristic, the regulated person/entity must "apply knowledge...in light of the materials and processes used." In the absence of adequate knowledge to determine whether the PV module is hazardous, it must be tested using Test Method 1311 Toxicity Characteristic Leaching Procedure (TCLP) or an equivalent EPA-approved method. Although TCLP is the predominant method used to today to make a hazardous waste determination for PV modules, evidence from this study concludes it is not practical to TCLP test every PV module even in a single utility-scale installation, and a scalable solution is needed. This study finds that knowledge-based hazardous waste determinations may allow a regulated person/entity to make a hazardous waste determination for more than one PV module at one time - making this regulatory pathway a potential scalable solution. Through legal analysis and interviews with 44 experts, the authors explore what it means to make an accurate knowledge-based hazardous determination for PV modules considering sources and forms of information as well as potential limitations. The work aims to provide a foundation for building consensus on whether knowledge-based hazardous determinations are a viable, scalable industry approach for solar.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Lunar Surface Position Determination using Perceived Signal Strength

The purpose of this project is to evaluate the feasibility of transmitters and receivers on the lunar surface for Position Determination (PD) without any form of lunar Global Positioning System (GPS). The early Artemis program may lack GPS satellites orbiting the Moon, and it is critical that activities with the lander, rover, and crew EVA identify their position on the lunar surface at all times. This project creates a prototype system that trilaterates user position based upon the perceived signal from at least 3 nearby transmission towers, called “Lunar Access Points”. The application of perceived signal strength for surface PD has historically been used in terrestrial systems such as Long Range Navigation (LORAN), which was popular with the maritime industry prior to the Global Positioning System (GPS). The ease of installing such a local system for early Artemis missions provides a critical resource until satellite-based position determination systems are deployed. A surface-based PD can also be used in GPS-denied environments such as deep craters or lava tubes where satellite visibility is compromised. By demonstrating the basic capability of surface PD, this student team has learned about issues with power, distance, thermal, dust, radiation, data processing, and communication problems applicable to the lunar surface. This knowledge can feed into future NASA requirements to improve the capability of a LunaNET implementation for the Artemis program. This project follows 10 years of successful collaboration between NASA JSC/ARES, Texas Space, Technology, Applications and Research (T STAR) and Texas A&M University in a Public, Private, Academic (PPA) Partnership. NASA funds T STAR to mentor undergraduate Capstone teams in the College of Engineering Department to design, built, and test prototypes meeting NASA requirements. TAMU faculty lead the student teams in their academic class, and NASA Subject Matter Experts (SMEs) provide T STAR and students insight on requirements evolution, prior design projects, and future development goals.

Position Determination↗

Lime slurry treatment of soils developing on abandoned coal mine spoil: Linking contaminant transport from the micrometer to pedon-scale

Historical and abandoned coal mine spoil continues to generate acid- and metal(loid)-rich porewaters and represents a geographically large and diffuse non-point source of contamination to local watersheds. A potentially inexpensive approach to treat these materials and soils developing on them is through the application of lime slurries, to neutralize acidity and encourage the (co)precipitation of metal(loids) with Fe(III)-(oxy)hydroxides, and potentially other metal-oxides and/or Ca-bearing phases. Here, the efficacy of this approach was evaluated through parallel field application and laboratory-based flow-through column experiments. The field site is Huff Run sub-watershed 25 located in Tuscarawas County, Ohio and was chosen in part because it was previously classified as one of the most highly AMD-impacted sub-watersheds in the region. Two locations with historical spoil were chosen and suction lysimeters were installed at 25 and 75 cm depth to monitor porewater composition on two sides at the base of each pile. Half of each slope received seven lime slurry treatments from June through October of 2017. A suite of aqueous (ICP-OES, IC, and TOC-L) and solid phase geochemical and mineralogical approaches (quantitative SEM-EDS and synchrotron μ-XRF) were used to determine how composition, texture, morphology, and spatial distribution of mineral coatings differ in pre- and post-lime treated soils, and how that impacts the distribution and transport of trace metal(loid)s. Mine spoil porewater at site 1 was slightly less alkaline (pH ranging from 7.04 to 7.37) than at site 2 (ranging from 7.55 to 7.71), and average electrical conductivity values at site 1 (316–405 μS cm —1 ) were slightly lower than at site 2 (358–464 μS cm —1 ), although differences between the sites were not significant. Porewater pH and electrical conductivity in all lysimeters decreased over the course of the field season but there was no obvious response to lime treatment at either site or any depth. At site 1, both treatment and depth were significant factors affecting Ca, K, Ni, SO 4 2— , and DOC concentrations while only treatment effects were significant for dissolved Al and Cu (p < 0.05). For all soils, there were no trends in metal concentration observed over time although DOC and SO 4 2— decreased over the field season. Pedon-scale changes in metal porewater concentrations in response to treatment were linked to micrometer-scale changes in mineral surface coatings; specifically, higher concentrations of Ca, Fe, Mn, and Zn were observed in the coatings and no changes were observed in Fe redox speciation, whereas total S decreased likely due to oxidation of S in coal fragments. In contrast to the field experiment, the column experiments exhibited a much greater response in effluent composition with respect to lime treatment. The untreated columns had approximately an order of magnitude more H + leached over the course of the experiment (p < 0.001) and resulted in greater Ca, Al, Cu, and DIC leached and less Mn, Zn, and SO 4 2— . Soils treated with the lime slurry in the column experiments exhibited larger and thicker secondary Fe-coatings, including the addition of Fe-sulfates. Despite clear trends in the laboratory-based column experiment where the lime-to-soil ratio was higher, the effects were either muted or undetected in the field pilot project, suggesting that a higher application rate of lime in the field is needed to achieve a similar effect. This work provides evidence that a less alkaline lime slurry could be a practical and inexpensive method of treating coal mine spoil-impacted soils and represents an important step in linking laboratory-based remediation studies to implemented field-based studies.

58 GEOSCIENCES↗

Fuel cell technology program

A fuel cell technology program was established to advance the state-of-the-art of hydrogen-oxygen fuel cells using low temperature, potassium hydroxide electrolyte technology as the base. Program tasks are described consisting of baseline cell design and stack testing, hydrogen pump design and testing, and DM-2 powerplant testing and technology extension efforts. A baseline cell configuration capable of a minimum of 2000 hours of life was defined. A 6-cell prototype stack, incorporating most of the scheme cell features, was tested for a total of 10,497 hours. A 6-cell stack incorporating all of the design features was tested. The DM-2 powerplant with a 34 cell stack, an accessory section packaged in the basic configuration anticipated for the space shuttle powerplant and a powerplant control unit, was defined, assembled, and tested. Cells were used in the stack and a drag-type hydrogen pump was installed in the accessory section. A test program was established, in conjunction with NASA/JSC, based on space shuttle orbiter mission. A 2000-hour minimum endurance test and a 5000-hour goal were set and the test started on August 8, 1972. The 2000-hour milestone was completed on November 3, 1972. On 13 March 1973, at the end of the thirty-first simulated seven-day mission and 5072 load hours, the test was concluded, all goals having been met. At this time, the DM-2 was in excellent condition and capable of additional endurance.

Source record↗

A Microsoft Project-Based Planning, Tracking, and Management Tool for the National Transonic Facility's Model Changeover Process

The removal and installation of sting-mounted wind tunnel models in the National Transonic Facility (NTF) is a multi-task process having a large impact on the annual throughput of the facility. Approximately ten model removal and installation cycles occur annually at the NTF with each cycle requiring slightly over five days to complete. The various tasks of the model changeover process were modeled in Microsoft Project as a template to provide a planning, tracking, and management tool. The template can also be used as a tool to evaluate improvements to this process. This document describes the development of the template and provides step-by-step instructions on its use and as a planning and tracking tool. A secondary role of this document is to provide an overview of the model changeover process and briefly describe the tasks associated with it.

Vairo, Daniel M.↗

HBET V3.0 Installation Manual

The Hydropower Biological Evaluation Toolset (HBET) V3.0 now requires Python v3.11.0 to be installed, following the addition of the absolute fish injury rate prediction feature. This version introduces two new strike metrics—based on velocity and pressure—to provide a more precise understanding of the biological effects of fish collisions with rigid structures within the fish passage system. Additionally, SQL Server 2019 is the supported database for this release. This installation guide will walk users through the process of installing HBET V3.0 along with all necessary dependencies.

13 HYDRO ENERGY↗

Low-Cost, Light Weight, Thin Film Solar Concentrator

This research addresses a cost barrier towards achieving a solar thermal collector system with an installed cost of $75/sq m and meet the Department of Energy's (DOE's) performance targets for optical errors, operations during windy conditions and lifetime. Current concentrators can cost as much as 40-50% of the total installed costs for a CSP plant. In order to reduce the costs from current $200-$250/sq m, it is important to focus on the overall system. The reflector surface is a key cost driver, and our film-based polymer reflector will help significantly in achieving DOE's cost target of $75/sq m. The ease of manufacturability, installation and replacement make this technology a compelling one to develop. This technology can be easily modified for a variety of CSP options including heliostats, parabolic dishes and parabolic troughs.

Concentrating Solar Power (CSP)↗

Rotational Millimeter-Wave Shoe Scanner Using the Discrete Fourier Transform for Backprojection-Based Image Reconstruction

An active 3D microwave / millimeter-wave shoe scanner was previously developed at the Pacific Northwest National Laboratory (PNNL) using two linear arrays scanned over a rectilinear aperture. The radar system chirps a frequency sweep from 10-40 GHz. These frequencies allow imaging through optically opaque material such as leather, rubber, plastics, and other dielectrics. The system was designed to detect concealed items in the soles of shoes while allowing people to leave their shoes on through a security checkpoint. To shrink the footprint of the system, a new iteration of the design has been developed that scans the two linear arrays over a circular aperture. This new footprint opens the possibility of it being installed in the floor of a cylindrical millimeter-wave body scanner. The backprojection-based multilayer dielectric image reconstruction developed at PNNL can easily handle arbitrary spatial sampling, accommodating the new rotational shoe scanner design. Commonly, the fast Fourier transform (FFT) is used to efficiently compute the range response from the data collected by the system as a preprocessing step to the backprojection algorithm. It was found that converting to range using the discrete Fourier transform (DFT) directly has some advantages over the FFT. For example, nonlinear and non-uniform frequency sweeps can easily be compensated for during the computation of the DFT and only the range bins of interest need to be computed and their spacing can be chosen arbitrarily. Because the range conversion step of the image reconstruction is the fastest part of the process there is very little speed penalty for using the DFT over the FFT and it can even increase the speed of image reconstruction when the ranges of interest are fewer than the total span that is calculated in the FFT.

Millimeter-wave imaging, microwave imaging, shoe s↗

Control, Fault Management, and Grid Support Functionality of an MV AC-DC Solid State Transformer based EV Extreme Fast Charging Station

Electric vehicles (EVs) have become increasingly popular in recent times while revolutionizing the consumer and commercial transportation market. The development of charging infrastructure has become one of the priorities for increasing the adoption of EVs. Extreme fast charging (XFC) technology can reduce the so-called ’range anxiety’ of consumers as they significantly reduce the charging time. With the advent of wide band-gap (WBG) power devices and improvement in power electronic converters, medium voltage (MV) solid state transformer (SST) based XFC system has the potential to replace the traditional XFC stations because of the lower footprint, ease of installation, enhanced control feature, and better system efficiency. The control system design is one of the critical aspects of the SST development process. Careful consideration and detailed analysis are required to find out suitable control method for the SST based on its topology among different centralized and decentralized control architectures. Also, the control parameters selection and potential improvement to the transient response of the controller ought to be investigated. Another major concern of the SST is different types of internal fault which reduces the overall reliability of the XFC system. As a result, designing a robust protection system is essential. Among different fault modes, open circuit switch faults have received significant attention as an active research area because of their likelihood and severe effects on converters. Therefore, the power stages used in the XFC system require functional and accurate open circuit switch fault management methods. An equally significant aspect of this SST based XFC is its compatibility in a microgrid where there is no synchronous generator present. When the grid is not available, the XFC SSTs can provide grid forming capability and continue supplying the critical loads in islanded mode. The transition between grid connected and islanded mode, especially the grid resynchronization process has to be carefully performed for the safety of the microgrid components. The challenges posed by the aforementioned issues have inspired the work done in this dissertation. Here, a 13.2 kV, 1 MVA, AC/DC SST for the XFC system is examined and a comparative analysis is conducted to select the control architecture based on feasibility of implementation and performance. A detailed control parameter design process is demonstrated considering the sensor dynamics and delay. The selected decentralized control method is augmented by introducing a novel sensor-less load current feedforward method to provide better voltage regulation at the DC bus during a change of load. Next, in the fault management section, a hierarchical failure mode effect analysis (FMEA) is proposed to enable a systematic design of the internal fault protection of the XFC SST as there are limited examples in the literature regarding the analysis of the safety and design of the protection of a power electronic converter system. Novel open circuit switch fault management methods for the converters in the system are presented. Finally, XFC SST based MV microgrid operations in grid connected mode and islanded mode are explored. A secondary control method for grid resynchronization is presented and a design process of control parameters is shown to ensure the stability of the secondary voltage and frequency regulation.

30 DIRECT ENERGY CONVERSION↗

Mapping and Characterizing the Visual Impacts of the Existing US Wind Turbine Fleet

Visual impacts of wind turbines have been a persistent concern for wind energy development in the United States (US) for decades and remain a major source of project delays and cancellations. Assessments of visual impacts are frequently performed at a local scale for individual projects, but a comprehensive understanding of broader geographic patterns in visual impacts across the US is lacking. This paper presents a visual impact assessment of the existing land-based wind turbine fleet of the contiguous United States (CONUS). The assessment combines geographic information systems and 3D simulation methods to account for key factors driving the visual magnitude of impacts from the installed turbines. The results indicate that, despite the deployment of approximately 70,000 turbines and over 144 gigawatts of land-based wind in the CONUS, the visual impacts are very small when measured as a proportion of land area, population, and sensitive visual resources. Nonetheless, visual impacts are not evenly distributed: people experience a concentrated share in a small number of natural settings, primarily including plains, prairies, and deserts. Finally, we find that although increased density of wind development consistently leads to visual impacts across a greater proportion of land, it does not always lead to impacts to a greater share of the population. These findings suggest that visual impacts from wind energy are generally well-mitigated across the CONUS to date but also highlight the need for a deeper understanding of landscape sensitivity and individual perceptions of wind turbines in the most heavily impacted natural settings.

3D simulation↗

Johnson Space Center's Solar and Wind-Based Renewable Energy System

The NASA Johnson Space Center (JSC) in Houston, Texas has a Sustainability Partnership team that seeks ways for earth-based sustainability practices to also benefit space exploration research. A renewable energy gathering system was installed in 2007 at the JSC Child Care Center (CCC) which also offers a potential test bed for space exploration power generation and remote monitoring and control concepts. The system comprises: 1) several different types of photovoltaic panels (29 kW), 2) two wind-turbines (3.6 kW total), and 3) one roof-mounted solar thermal water heater and tank. A tie to the JSC local electrical grid was provided to accommodate excess power. The total first year electrical energy production was 53 megawatt-hours. A web-based real-time metering system collects and reports system performance and weather data. Improvements in areas of the CCC that were detected during subsequent energy analyses and some concepts for future efforts are also presented.

Vasquez, A.↗

Contraction design for small low-speed wind tunnels

An iterative design procedure was developed for 2- or 3-dimensional contractions installed on small, low speed wind tunnels. The procedure consists of first computing the potential flow field and hence the pressure distributions along the walls of a contraction of given size and shape using a 3-dimensional numerical panel method. The pressure or velocity distributions are then fed into 2-dimensional boundary layer codes to predict the behavior of the boundary layers along the walls. For small, low speed contractions, it is shown that the assumption of a laminar boundary layer originating from stagnation conditions at the contraction entry and remaining laminar throughout passage through the successful designs is justified. This hypothesis was confirmed by comparing the predicted boundary layer data at the contraction exit with measured data in existing wind tunnels. The measured boundary layer momentum thicknesses at the exit of four existing contractions, two of which were 3-D, were found to lie within 10 percent of the predicted values, with the predicted values generally lower. From the contraction wall shapes investigated, the one based on a 5th order polynomial was selected for newly designed mixing wind tunnel installation.

Bell, James H.↗

Wellbore integrity assessment with casing-based advanced sensing

Wellbore integrity is of paramount importance to subsurface resource extraction, energy storage 1 and waste disposal. After installation, well casing and cement are subject to mechanical stress due to near-well pressure changes and fluid induced corrosion. This is exacerbated for geothermal wells where produced fluid is at high temperature and corrosive. The current state-of-the-art technologies for wellbore integrity assessments are an array of cased hole logging tools. Wireline deployed acoustic, electromagnetic and mechanical tools are all available to inspect steel casing corrosion and casing-cement bond and these tools can provide high-resolution assessment of borehole conditions. They are intrusive, however, in terms of borehole preparation and interruption to the normal operation of the wells, and not suitable for high temperature or highly deviated well deployments. In addition, these measurements are performed infrequently due to high cost, and are therefore incapable of providing frequent data to better predict borehole degradation trajectory, which can help provide early warning of potential borehole failures. For this project we are developing a suite of novel, non-invasive, casing based tools for wellbore integrity assessment, combining fast/low cost screening with higher-precision investigation. Our approach is based on monitoring the response of the casing when energized at the wellhead, thereby interrogating the casing without well intervention. Lab, field and numerical approaches are used in our study. During the early stage of the research, we focus on numerical simulations, which have shown the sensitivity of the low frequency electromagnetic (EM) signals to changes in borehole depths and have successfully tested the concept at a field site with different length well casings. Initial seismic modeling efforts have also demonstrated our capability to simulate seismic tube wave and seismic field alterations due to borehole breakage and associated fluid leakage. Further numerical, laboratory and field experiments are underway for additional technology sensitivity analysis, particularly the transient EM/Seismic reflectometry methods, data acquisition optimization, and numerical simulation improvements.

Wilt, Michael↗

CCSI Toolset 3.18 Release

CCSI Toolset 3.18 Release Highlights FOQUS was updated to allow installation for users using MacOS on Apple silicon. FOQUS Cloud support was added for user plugins. The Optimality-Based Design of Experiments tutorials were updated to reflect the latest changes in the user interface flow. The plot discrete sliders were fixed for CDF and 3D plots within Uncertainty Quantification, which were not working due to a matplotlib depreciation. The installation was updated to set the default location for the PSUADE executable if found in the environment. Updates were made to allow compatibility with NumPy 1.25. Additional documentation changes were made to fix typographical errors and fix a broken link to optional software.

AS↗

Key Drivers for Offshore Wind Deployment in the Western United States

The western coast of the United States has abundant natural resources, including wind, sun, and water. Despite strong ocean winds, offshore wind energy (OSW) in the Western United States is in the early stages of technology development due largely to the deep water off the coast, which requires floating platforms rather than fixed‐bottom turbines. Floating OSW increases the technical difficulty of installation and thus the cost relative to both fixed‐bottom OSW and land‐based turbines. OSW is a potential generation option to help meet increasing demand on the west coast of the United States because it likely has fewer land‐use conflicts than other technologies and complements sources in the existing electricity supply by providing energy during times of high system stress. This paper examines the possible drivers and barriers to OSW deployment on the West Coast using the National Laboratory of the Rockies' state‐of‐the‐art capacity expansion model and the Regional Energy Deployment System (ReEDS) model. We use ReEDS to explore a multitude of future scenarios looking at key drivers for OSW deployment, including variations on the cost of OSW, electricity demand growth, and the availability of competing technologies to examine the factors that may play a role in OSW growth. Assuming coastal state policies such as renewable portfolio and clean energy standards remain in place, we find that OSW can play a role in meeting electricity demand and provide energy during stressful grid conditions and find that deployment from the least‐cost investment model ranges from 7.6 to 38 GW by 2045.

17 WIND ENERGY↗

Development of Miniaturized High Temperature Multi Process Monitoring System

The main objective of this research program is to design, manufacture, and demonstrate a miniaturized, multi-process, monitoring system (mMPMS) for boiler condition management and easy system deployment to obtain a higher spatial resolution. This system will facilitate a Condition-Based Maintenance (CBM) philosophy that actively monitors the health of assets to predict and prevent failures and maximize availability and generating capacity at a reduced cost. CBM systems can provide boiler data that the advanced process control (APC) system can utilize for plant performance optimization, which is increasingly relevant as coal power plants shift from predominantly base-load operation to predominantly transient operation involving large load swings. The mMPMS is based on an electrochemical sensor that provides a real-time indication of the risk of damage to key locations in the radiant or convective section of a coal-fired boiler such as metal loss rates, heat flux, metal surface temperature, and deposit thickness. These indications can be utilized to optimize boiler performance as well as improve boiler availability in conjunction with corresponding operating conditions. This monitoring system was developed and tested in the high-temperature regions of coal-fired utility boilers in this project but can be applied to many other industries and applications as well. This project leveraged the existing electrochemical noise-based monitoring system and the new sensor design is small enough to be installed through the webbing of the waterwalls without the need for long shut-downs to bend tubes and to make it feasible to obtain high spatial resolution in the boiler. Data is transferred to the plant distributed control system (DCS) and any other control system. The sensor body that houses the sensor assembly was designed to ensure good conductive contact with boiler tubes to ensure the sensor is held at an identical temperature to the tube surface temperature. The data acquisition and signal conditioning modules were redesigned into a small footprint with optimized cooling of the module. System software was developed specifically for the new signal conditioning module and is compatible with plant PLCs. After the preliminary testing at a pilot-scale facility, the three mMPMS were installed at a full-scale pulverized coal-fired plant, PacifiCorp’s Hunter 3. The systems were demonstrated over 20,000 hours at the plant during regular operation. Also, the sensor data was fed to the plant’s advanced process control system to evaluate the corrosion control by the operation changes and utilized to understand the impacts of load cycling with different ramping up and down speeds. At the end of the project, the systems were converted to the permanent installation at the power plant to be used with the advanced process control system installed at the plant.

Advanced Sensors, Corrosion, Ash Deposition, Optim↗