Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “installations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Design fabrication and installation of a yaw measuring device

The results of work performed in the development and testing of a yaw measuring device are summarized. A review of the yaw measurement method; and the techniques and hardware needed for its implementation are presented. A description and summary of the tests performed at the U.S. Bureau of Mines Bruceton facility are included. Conclusions are summarized and recommendations for a unit capable of operation in a mine environment are presented.

Source record↗

Motel solar hot-water installation--Atlanta, Georgia

Analysis of hardness of local water, average insolation for site, and daily hot water requirements insures suitability of solar-energy system design. Report describes two units which are designed to supply 81 percent of motel's annual hot water demand based on hypothetical 85 percent occupancy. Report includes drawings, operating and maintenance instructions, and test results for 1 day of operation.

Source record↗

Solar energy system installed at the North Georgia APDC office building

A hydronic, automatic drain-down solar heating and cooling system is described. The system provides solar heat exchange from a 2,001 square foot effective collector area and supplies 65-70 percent of the building's cooling demand, 90-95 percent of the heating demand, and domestic hot water. The acceptance test plan and results, system operation and maintenance, and predicted system performance are presented.

Source record↗

Installation and checkout of the DOE/NASA Mod-1 2000-kW wind turbine generator

The Mod-1 machine was assembled without the blades, tested, and sent to the site at Boone, North Carolina for erection. The blades were transported directly to the site. A series of checkout tests were then conducted to evaluate performance and loads. The results of these tests compared well with the design data.

Puthoff, R. L.↗

A mechanical adapter for installing mission equipment on large space structures

A mechanical attachment adapter was designed, constructed, and tested. The adapter was was included in a simulation program that investigated techniques for assembling erectable structures under simulated zero-g conditions by pressure-suited subjects in a simulated EVA mode. The adapter was utilized as an interface attachment between a simulated equipment module and one node point of a tetrahedral structural cell. The mating performance of the adapter, a self-energized mechanism, was easily and quickly demonstrated and required little effort on the part of the test subjects.

Lefever, A. E.↗

Solar heating system installed at Telex Communications, Inc., Blue Earth, Minnesota

The solar heating system for space heating a 97,000 square foot building which houses administrative offices, assembly areas, and warehouse space is summarized. Information on system description, test data, major problems and resolutions, performance, operation and maintenance manual, manufacturer's literature, and as-built drawings is presented.

Source record↗

Solar heating and hot water system installed at office building, One Solar Place, Dallas, Texas

A solar heating on cooling system is described which is designed to provide 87 percent of the space heating needs, 100 percent of the potable hot water needs and is sized for future absorption cooling. The collection subsystem consists of 28 solargenics, series 76, flat plate collectors with a total area of 1,596 square feet. The solar loop circulates an ethylene glyco water solution through the collectors into a hot water system exchanger. The water storage subsystem consists of a heat exchanger, two 2,300 gallon concrete hot water storage tanks with built in heat exchangers and a back-up electric boiler. The domestic hot water subsystem sends hot water to the 10,200 square feet floor area office building hot water water fixtures. The building cold water system provides make up to the solar loop, the heating loop, and the hot water concrete storage tanks. The design, construction, cost analysis, operation and maintenance of the solar system are described.

Source record↗

Solar heating and cooling system installed at Leavenworth, Kansas

A solar heating and cooling is described which is designed to furnish 90 percent of the overall heating load, 70 percent of the cooling load and 100 percent of the domestic hot water load. The building has two floors with a total of 12,000 square feet gross area. The system has 120 flat-plate liquid solar panels with a net area of 2,200 square feet. Five 3 ton Arkla solar assisted absorption units provide the cooling, in conjunction with a 3,000 gallon chilled water storage tank. Two 3,000 gallon storage tanks are provided with one designated for summer use, whereas both tanks are utilized during winter.

Source record↗

Solar heating and domestic hot water system installed at Kansas City, Fire Stations, Kansas City, Missouri

The solar system was designed to provide 47 percent of the space heating, 8,800 square feet area and 75 percent of the domestic hot water (DHW) load. The solar system consists of 2,808 square feet of Solaron, model 2001, air, flat plate collector subsystem, a concrete box storage subsystem which contains 1,428 cubic feet of 0.5 inch diameter pebbles weighing 71.5 tons, a DHW preheat tank, blowers, pumps, heat exchangers, air ducting, controls and associated plumbing. Two 120 gallon electric DHW heaters supply domestic hot water which is preheated by the solar system. Auxiliary space heating is provided by three electric heat pumps with electric resistance heaters and four 30 kilowatt electric unit heaters. There are six modes of system operation.

Source record↗

Solar Water-Heater Design and Installation

Solar/Water heater system works as follows: Solar--heated air is pumped from collectors through rock bin from top to bottom. Air handler circulates heated air through an air-to-water heat exchanger, which transfers heat to incoming well water. In one application, it may reduce oil use by 40 percent.

Harlamert, P.↗

Economic Evaluation of Single-Family-Residence Solar-Energy Installation

Long-term economic performance of a commercial solar-energy system was analyzed and used to predict economic performance at four additional sites. Analysis described in report was done to demonstrate viability of design over a broad range of environmental/economic conditions. Report contains graphs and tables that present evaluation procedure and results. Also contains appendixes that aid in understanding methods used.

Source record↗

Two-Story-Dwelling Solar Installation

Report covers system description of a roof mounted solar energy system in Georgia. Includes study approach, economic analysis, results of analysis and economic uncertainty analysis. Elaboration on some of equations, procedures, and parameters used in analysis is found in report appendixes.

Source record↗

Solar heating and hot water system installed at Shoney's Restaurant, North Little Rock, Arkansas

A solar heating system designed to supply a major portion of the space and water heating requirements for a restaurant is described. The restaurant has a floor space of approximately 4,650 square feet and requires approximate 1500 gallons of hot water daily. The solar energy system consists of 1,428 square feet of Chamberlain flat plate liquid collector subsystem, and a 1500 gallon storage subsystem circulating hot water producing 321 x 10 to the 6th power Btu/Yr (specified) building heating and hot water heating.

Source record↗

Solar hot water system installed at Day's Inn Motel, Dallas, Texas (Valley View)

The solar system was designed to provide 65 percent of the total domestic hot water (DHW) demand. A liquid (water) flat plate collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank when the solar pump is not running. Heat is transferred from the DHW tanks through a shell and tube heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up standby losses. All pumps are controlled by differential temperature controllers.

Source record↗

Solar hot water system installed at Day's Inn Motel, Savannah, Georgia

The Solar System was designed to provide 50 percent of the total Domestic Hot Water (DHW) demand. Liquid Flat Plate Collectors (900 square feet) are used for the collector subsystem. The collector subsystem is closed loop, using 50 percent Ethylene Glycol solution antifreeze for freeze protection. The 1,000 gallon fiber glass storage tank contains two heat exchangers. One of the heat exchangers heats the storage tank with the collector solar energy. The other heat exchanger preheats the cold supply water as it passes through on the way to the Domestic Hot Water (DHW) tank heaters. Electrical energy supplements the solar energy for the DHW. The Collector Mounting System utilizes guy wires to structurally tie the collector array to the building.

Source record↗

Solar hot water system installed at Days Inn Motel, Jacksonville, Florida

The solar system was designed to provide 65 percent of the hot water demand. Water in the liquid flat plate collector (900 square feet) system automatically drains into the 1000 gallon lined and vented steel storage tank when the pump is not running. Heat is transferred from storage to Domestic Hot Water (DHW) tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and heat exchanger enables solar heated water to help make up DHW standby losses. All pumps are controlled by differential temperature.

Source record↗

Solar hot water system installed at Days Inn Motel, Dallas, Texas (Forrest Lane)

The solar system was designed to provide 65 percent of the total Domestic Hot Water (DHW) demand. The liquid flat plate (water) collector (1,000 square feet) system automatically drains into the 1,000 gallon steel storage tank located in the mechanical room when the pump is not running. Heat is transferred from the storage tank to DHW tanks through a tube and shell heat exchanger. A circulating pump between the DHW tanks and the heat exchanger enables solar heated water to help make DHW tank standby losses. All pumps are controlled by differential temperature.

Source record↗

Full-scale aerodynamic characteristics of a propellar installed on a small twin-engine aircraft wing panel

Full-scale measurements of shaft thrust and torque were made. Wind-tunnel speeds and blade angles were set for full-scale flight conditions. Excellent quality measurements were obtained of the thrust coefficient, the power coefficient, and the propeller efficiency for various values of the advance ratio and the blade incidence angle at 3/4-blade radius. A conventional propeller theory found in the literature was applied to the present results. Although thrust, power, and efficiency were somewhat overpredicted, the advance ratio for maximum efficiency was predicted quite accurately. It was found that, for some conditions, spinner drag could be significant. A simple correction that was based on the spinner base pressure substantially accounted for the changes in efficiency that resulted from this cause.

Barlow, P. R.↗