Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection rate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Experimental Investigation of Polymer Induced Fouling of Heater Tubes in the First-Ever Polymer Flood Pilot on Alaska North Slope

Mineral fouling in heat exchangers has been extensively investigated by researchers in recent times. The oil and gas industry has a long history of fouling issues in production systems as a result of produced fluids treatment. Due to decline in production rates in oilfields new technologies are being developed and field tested in pilots. Polymer flooding is one such technology that involves addition of polymers to injection fluids to enhance oil production. A polymer flood pilot has been set up in the Schrader Bluff viscous oil reservoir at Milne Point field on the Alaska North Slope (ANS). The results from the pilot are encouraging, however a major concern of the operator is the influence of polymer on the production system after breakthrough, especially the fouling in heat exchangers. This study investigates the propensity of polymer fouling on the heater tubes as a function of different variables, with the ultimate goal of determining safe and efficient operating conditions. This work applies a multi-experimental approach to study the severity of polymer-induced fouling in both dynamic and static states of produced fluids as well as studying the stability of polymer solutions at different temperatures. A unique experimental setup was designed and developed in-house to simulate the fouling process on the heating tube. The influence of heating tube skin temperature, tube material, and polymer concentration on fouling tendency was investigated. Each test was run five times with the same tube, and in each run, the freshly prepared synthetic brine and polymer solution was heated from 77°F to 122°F to mimic field-operating conditions. The heating time and fouling amount were recorded for each run. Dynamic Scale Loop (DSL) tests were conducted to study fouling due to polymer at different temperatures (165°F to 350°F) in a dynamic state of fluid flow where the fluids mimic the residence time of fluids in the heat exchanger on the field pilot. Cloud point measurement has also been conducted to find the critical temperature at which the polymer in solution becomes unstable and precipitates out. The morphology and composition of the deposit samples were analyzed by environmental scanning electron microscopy (ESEM) and X-ray diffraction (XRD), respectively. It was found that the presence of polymer in produced fluids would aggravate the fouling issues on both carbon steel and stainless-steel surfaces at all tested skin temperatures. Only higher skin temperatures of 250°F and 350°F could cause polymer-induced fouling issues on the copper tube surface, and the fouling tendency increased with polymer concentration. At the lower skin temperatures of 165°F, no polymer-induced fouling was identified on the copper tube. A critical temperature that is related to the cloud point of the polymer solution was believed to exist, below which polymer-induced fouling would not occur, and only mineral scale was deposited but above which the polymer would aggravate the fouling issue. The cloud point of the tested polymer solution was determined to be between 220°F and 230°F. In the DSL tests it was found that at higher skin temperatures of 250°F and 350°F tube blocking was observed in the DSL tests whereas the tests at 165°F and 200°F did not show any tube blocking in the same time period. These experiments also manifested the influence of cloud point of the solution as deposit rate increased significantly in both carbon steel and stainless-steel tubes when the skin temperature was higher than the solution cloud point. The results of this study have provided guidance to the operator for the field-operations.

Dhaliwal, Anshul↗

The JET hybrid scenario in Deuterium, Tritium and Deuterium-Tritium

The JET hybrid scenario has been developed from low plasma current carbon wall discharges to the record-breaking Deuterium-Tritium plasmas obtained in 2021 with the ITER-like Be/W wall. The development started in pure Deuterium with refinement of the plasma current, and toroidal magnetic field choices and succeeded in solving the heat load challenges arising from 37 MW of injected power in the ITER like wall environment, keeping the radiation in the edge and core controlled, avoiding MHD instabilities and reaching high neutron rates. The Deuterium hybrid plasmas have been re-run in Tritium and methods have been found to keep the radiation controlled but not at high fusion performance probably due to time constraints. For the first time this scenario has been run in Deuterium-Tritium (50:50). These plasmas were re-optimised to have a radiation-stable H-mode entry phase, good impurity control through edge T i gradient screening and optimised performance with fusion power exceeding 10 MW for longer than three alpha particle slow down times, 8.3 MW averaged over 5 s and fusion energy of 45.8 MJ.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation induced non-linear oscillations in ITER baseline scenario plasmas in DIII-D

Abstract This work shows how the radiation brought about by metals or metal-equivalent radiators such as Kr and Xe produces non-linear dynamics on otherwise stationary β N flattops of DIII-D ITER Baseline Scenario demonstration discharges. The Kr and Xe gases are used to reproduce the radiative loss rates of W in present machines that operate at core temperatures much lower than the expected ITER temperature. Experiments on DIII-D with injection of Kr and Xe, as well as with sources of intrinsic metals reach the range of radiated fraction values expected in the ITER core and experience slow oscillations in temperature and radiated power. In many cases of high radiated fraction, the core temperature decreases enough for the safety factor profile to rise above the 1/1 rational surface, naturally eliminating sawteeth and occasionally producing a persistent helical core. The oscillations can be reproduced by a modified Lotka–Volterra system for temperature and radiated fraction if diffusion and noise are included, which indicates that the interplay between temperature and radiation can be the main cause of the cyclic nature of the system. A new physics based model which includes equations for temperature, density and input power can also reproduce the oscillations observed in the experiments. The present results suggest that the non-linearity of the system can be increased by the inclusion of the inherently non-linear alpha heating term, which is proportional to ∼ n e 2 T i 2 , and obtains oscillations in the model when added to an otherwise more stationary system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utah FORGE 5-2615: Laboratory Data for Insights on Hydraulic Fracture Closure and Stress Measurement

This dataset includes data from injection/fall-off experiments conducted in controlled laboratory settings. The aim is to investigate the physics governing fracture closure and the associated stress measurements during hydraulic fracturing. These time series data include flow rate, pressure, and volume measurements. These experiments were conducted as part of Utah FORGE Project 5-2615: Thermo-poromechanical Response of Fractured Rock.

15 GEOTHERMAL ENERGY↗

Analytical Expression for DC Link Capacitor Current in a Cascaded H-Bridge Multi-Level Active Front-End Converter

Medium-voltage grid-tied systems often use a cascaded H-bridge multi-level active front-end. In this converter, dc link bus capacitors play an important role in stabilizing the converter and enabling both active and reactive power injections. The present work provides analytical expressions for the capacitor current, which are essential for optimizing system design (especially capacitor size vs. lifetime). Then, the expression is incorporated into the grid connected bidirectional power system model. Consequently, this work contributes to the guiding principles to choose accurate dc link capacitor ratings against grid-side power delivery requirements. The analytical results have been validated with detailed simulations and hardware results.

cascaded H-bridge, carrier-based PWM, dc-link capa↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

Thermal loading analysis of the ring injection dump for the Spallation Neutron Source facility

The ring injection dump (RID) is the largest beam dump in the Spallation Neutron Source facility at Oak Ridge National Laboratory and accepts a fraction of the beam from the ring that is not captured in the ring during injection. Thermo-fluid modeling of the RID components was performed during the initial design by using the software ANSYS CFX to characterize the power rating for the RID. From the calculations, the power rating was lowered from 200 kW to 150 kW, at 1.3 GeV beam energy due to concerns regarding the heating of the concrete structure. The Proton Power Upgrade project scope included reevaluating the power limit to the RID in anticipation that increasing it would provide more operational flexibility. The focus was on the shielding because it was the limiting factor, and data collected from thermocouples installed on the structure were used to benchmark the analysis. A three-stage process was adopted in the latest study. First, the already existing steady-state calculations were validated and extended with the latest Monte Carlo N-Particle source term calculations. Second, transient calculations were conducted to capture the dynamic state of the system in response to the energy dumped to the RID during the following operational period of the beam from 2005–2019 (14 years), and sensitivity analyses of crucial parameters were performed to benchmark the model with reasonable accuracy. Finally, an idealized transient cycle analysis was conducted with realistic duty factors to predict the temperature distribution at higher beam powers. Overall, the results confirmed the accuracy of the original steady state model but allowed the development of a new validated transient model with higher accuracy for future analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correcting beam space charge effects in Active-Target Time Projection Chamber

By providing a large gaseous volume for nuclear interactions while simultaneously recording the tracks of resulting reaction products, an active target serves as both a thick target and a detector. Once a reaction occurs, the emitted charged fragments strip electrons from the target gas along their path as they transverse the detector. Collection of these stripped electrons allow for detection of the product tracks. As beam intensity increases, the resulting ionization in the active target can significantly distort this collection of electrons. If left uncorrected, the resulting measurements could be wrong. In this paper, we investigate the impact of the space charge produced by heavy radioactive beams within the Active Target - Time Projection Chamber at Michigan State University. The beams are injected parallel to the electric field of the time projection chamber which is operated without a magnetic field for this experiment. Furthermore, we analyze the rate dependence of the space charge effects and demonstrate that they can be modeled and effectively corrected.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Conceptual design report: a ring-based electron cooling system for the EIC

This report describes a concept of an EIC cooling system, based on a proven induction-linac technology with a DC electron beam. The system would operate in a full energy range of proton beams (100–270 GeV) and would provide 50–100 A electron beams, circulating in a cooler ring for 5 ms. Every 5 ms a new electron pulse would be injected into the cooler ring to provide continuous cooling at collisions. Operations with a 10-ms cycle is possible but it will reduce the cooling rates by ~30%. The system is capable of delivering the required performance in the entire EIC energy range with emittance cooling times of less than 1–2 hours.

43 PARTICLE ACCELERATORS↗

Experimental Characterization of Hydrocarbons and Nitrogen Oxides Production in a Heavy-Duty Diesel–Natural Gas Reactivity-Controlled Compression Ignition Engine

Reactivity-Controlled Compression Ignition (RCCI) combustion is considered one of the most promising Low-Temperature Combustion (LTC) concepts aimed at reducing greenhouse gases for the transportation and power generation sectors. Due to the spontaneous combustion of a lean, nearly homogeneous mixture of air and low-reactivity fuel (LRF), ignited through the direct injection of a small quantity of high-reactivity fuel (HRF), RCCI (dual-fuel) shows higher efficiency and lower pollutants compared to conventional diesel combustion (CDC) if run at very advanced injection timing. Even though a HRF is used, the use of advanced injection timing leads to high ignition delays, compared to CDC, and generates high cycle-to-cycle variability, limited operating range, and high pressure rise rates at high loads. This work presents an experimental analysis performed on a heavy-duty single-cylinder compression ignited engine in dual-fuel diesel–natural gas mode. The objective of the present work is to investigate and highlight the correlations between combustion behavior and pollutant emissions, especially unburned hydrocarbons (HC) and oxides of nitrogen (NOx). Based on the analysis of crank-resolved pollutants measurements performed through fast FID and fast NOx systems under different engine operating conditions, two correlations were found demonstrating a good accordance between pollutant production and combustion behavior: Net Cyclic Hydrocarbon emission—cyclic IMEP variations (R 2 = 0.86), and Cyclic NOx—maximum value of the Rate of Heat Released (R 2 = 0.82).

33 ADVANCED PROPULSION SYSTEMS↗

Mitigation of plasma–wall interactions with low-Z powders in DIII-D high confinement plasmas

Experiments with low-Z powder injection in DIII-D high confinement discharges demonstrated increased divertor dissipation and detachment while maintaining good core energy confinement. Lithium (Li), boron (B), and boron nitride (BN) powders were injected in H-mode plasmas (I p = 1 MA, B t = 2 T, P NB = 6 MW, < n e > = 3.6–5.0 · 10 19 m –3 ) into the upper small-angle slot divertor for 2 s intervals at constant rates of 3–204 mg s –1 . The multi-species BN powders at a rate of 54 mg s –1 showed the most substantial increase in divertor neutral compression by more than an order of magnitude and lasting detachment with minor degradation of the stored magnetic energy W mhd by 5%. Rates of 204 mg s –1 of boron nitride powder further reduce edge localized mode-fluxes on the divertor but also cause a drop in confinement performance by 24% due to the onset of an n = 2 tearing mode. The application of powders also showed a substantial improvement of wall conditions manifesting in reduced wall fueling source and intrinsic carbon and oxygen content in response to the cumulative injection of non-recycling materials. Furthermore, the results suggest that low-Z powder injection, including mixed element compounds, is a promising new core-edge compatible technique that simultaneously enables divertor detachment and improves wall conditions during high confinement operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Gas Stopper Developments for Improved Purity and Intensity of Low-Energy, Rare Isotope Ion Beams (Final Technical Report)

This final technical report summarizes the work of the Michigan State University (MSU) team supported by grant # DE-SC0021423 awarded by the Office of Nuclear Physics, Department of Energy. Objectives: The successful fulfillment of the FRIB science mission hinges on ensuring the availability of fast, stopped, and reaccelerated beams consisting of rare isotopes. This project's research and development focus was dedicated to supporting the advancement and creation of a cutting-edge linear gas stopper. The primary aim is to efficiently convert the high-intensity fast beams of rare isotopes provided by FRIB into high-quality, low-energy beams. These beams are essential for conducting stopped beam experiments or for subsequent reacceleration. The overarching goal is to advance technology, aiming to increase the beam rate capability of the linear gas stopper for medium-to-heavy-mass rare isotopes by more than tenfold compared to the currently most effective gas stopper in operation, and to improve the purity of the delivered beams. Project Description: The existing technology employed in gas stopping devices designed for low-energy, rare-isotope beams presents limitations in both the purity of extracted beams and the intensities of injected beams. These limitations are incompatible with the requirements of the recently commissioned rare isotope beam facility, FRIB. Our research and development efforts, aligned with the previously outlined objectives, focused on addressing the most critical aspects for enhancing beam-rate capability and purity. Specifically, advanced particle-in-cell simulations were developed and integrated into a simulation pipeline to explore the efficacy of multi-layer RF carpets on increasing ion transport efficiency with high incoming beam rates that generate space charge fields which can limit it. We also explored the possibility of using a collision-induced-dissociation (CID) gas cell to break up molecular contaminant ions that are generated during the stopping process. A prototype CID gas cell was constructed and tested with beams from an offline ion source, validating the concept with the successful demonstration of breaking of molecular ions. The outcome of this research enabled the formulation a conceptual design for a next-generation linear gas stopping device specifically tailored for FRIB. This device is envisioned to deliver rare-isotope-ion beams at a rate of 10 8 particles per second or higher, accompanied by advancements in purity. Methods employed: This project leverages advancements in technologies initially designed for the Advanced Cryogenic Gas Stopper (ACGS), the current state-of-the-art linear gas stopper, through the use of new simulations and beam purification via collision-induced-dissociation. The methods include: 1. Development of a prototype low-energy, low-pressure CID gas stopper. This prototype features a thin, approximately 20 nm, Si 3 N 4 entrance window designed for dissociating stable and rare-isotope molecular ions. The goal is to enhance beam purification and overall efficiency. 2. Creation of Particle-in-cell (PIC) simulations to assess the advantages of multi-layer RF carpets and multi-point extraction for ion transport efficiency. These simulations rely on the 3DCylPIC package, specifically designed for studying devices of this nature. The goal is to quantify and mitigate ion transport losses due to space charge generated in the stopping process of large numbers of ions. 3. Perform ion transport simulations across an RF carpet using an 8-phase travelling wave and evaluate its performance. Compared to the 4-phase RF carpets used in ACGS, the 8-phase carpets will double the wavelength of the generated traveling wave allowing for larger maximum RF amplitudes that could result in improved ion transport efficiency for high-intensity incoming beams when large space charge fields are present. Impact: Tackling the primary challenges associated with transforming high-energy projectile fragment beams into low-energy beams—specifically, addressing efficiency and purity—holds significant promise for advancing FRIB science. This advancement will particularly impact precision mass measurements, laser spectroscopy of short-lived nuclei, and studies in astrophysics and nuclear reactions using reaccelerated beams. These domains play a crucial role in addressing key questions outlined in the 2023 NSAC long-range plan, spanning nuclear structure, nuclear astrophysics, and fundamental symmetries. Additionally, they contribute to addressing 10 out of the 17 benchmarks identified by the NRC RISAC. The development of a next-generation gas stopping device capable of delivering low-energy, rare-isotope beams at a rate of 10 8 particles per second, or more, with high purity holds the potential to unlock experiments that would otherwise be unfeasible. Furthermore, it is expected to reduce the time required for experiments at FRIB, thereby maximizing scientific output. The research and development activities performed as part of this project bolstered essential competencies at FRIB in beam physics and ion source technologies, provided valuable training opportunities for junior scientists.

43 PARTICLE ACCELERATORS↗

Investigations into EGR dilution tolerance in a pre-chamber ignited GDI engine

EGR is a useful means to improve fuel economy in spark-ignited gasoline engines, especially under part-load conditions by means of reducing throttling losses. There is also a significant reduction in NOx emissions due to the reduced peak cylinder temperatures. However, the ability of conventional spark ignition systems to reliably ignite dilute mixtures limits the dilution tolerance due to the onset of combustion instability. In this study, an active pre-chamber system was evaluated at part load condition with various EGR rates using a regular grade full boiling range gasoline. A premixed air-fuel mixture was supplied to the pre-chamber, which assists in scavenging the residual mass fractions to enable reliable ignition of EGR dilute mixtures in the main combustion chamber. A range of pre-chamber injection, air-fuel mixture formulation, and ignition timing strategies were evaluated during the EGR sweeps. In addition, 0-D and 1-D simulations were conducted in GT-Power to assess the thermodynamic state and composition in the pre-chamber, as well as estimate the jet momentum at the various dilution rates. The active pre-chamber extended the EGR dilution limit from 20% for conventional SI to above 30%, with a higher pre-chamber flow rate (more scavenging) resulting in increased combustion stability. A tradeoff between the jet momentum and spark timing was observed when analyzing the GT-Power simulations and the pre-chamber jet momentum was found to decrease with increasing EGR rate. At unstable high EGR operation, no relation could be found between the pre-chamber indicated data and main chamber combustion stability.

33 ADVANCED PROPULSION SYSTEMS↗

Core-scale numerical simulation and comparison of breakdown of shale and resulting fractures using sc-CO 2 and water as injectants

Supercritical carbon dioxide (sc-CO 2 ) is an alternative to water for stimulation of low permeability systems such as shale gas and geothermal resources. Previously core-scale experimental studies have compared the behavior of CO 2 to water injection for sample breakdown. Due to differences in experimental setup and core sample preparation, inconsistent or even apparently contradictory conclusions have resulted. To reconcile this contradiction, a phase-field numerical model is applied to understand hydraulic fracturing experiments using Green River shale found in the literature. The finite element numerical model incorporates a rate-dependent phase-field fracture model developed separately to describe fracture initiation and growth. We investigate the impact of various material and fluid properties on the resulting fractures. Most importantly, we study the effect of fluid properties and boundary conditions on the breakdown pressure, including the direction of the resulting fracture plane. Model results predict that (1) sc-CO 2 injection in the laboratory may result in greater breakdown pressure than that of water under no-flow boundary conditions because lower viscosity sc-CO 2 may result in pressure build up at the core boundary that opposes fracture initiation and (2) lower viscosity sc-CO 2 also produces fast-propagating fractures that are less influenced by the bedding plane on their resulting fracture topology. Here our model offers a straightforward explanation and reconciliation of existing experimental observations, as well as a means to extrapolate to new conditions. Exploration of field-scale conditions suggests less pronounced or no elevation in breakdown pressure when sc-CO 2 is injected because the pressure build up effect at the system boundary is significantly less or absent at field length scales.

42 ENGINEERING↗

Analysis of neoclassical tearing mode stabilization experiment by electron cyclotron injection in KSTAR

We report the neoclassical tearing mode (NTM) stabilization experimental results by injection of the electron cyclotron (EC) beam in KSTAR, and its analysis with integrated modelling. In the KSTAR experiment, NTM was intentionally induced and the EC beam was injected by the plasma control system (PCS) to stabilize it. Here, the EC angle was controlled based on the minimum seeking algorithm for the island growth rate. Although the EC angle was not changed significantly, the island width significantly decreased towards the end of the experiment followed by the recovery of plasma performance. To assess the NTM stabilization experiment from a stability perspective, we performed integrated modelling with TRIASSIC utilizing the reconstructed equilibrium with magnetic diagnostics and motional stark effect diagnostics. As a result, we observed that the NTM is stabilized by EC.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pressure Transient Analyses and Poroelastic Modeling of Hydraulic Fracture Dilation for Multiple Injections at the Devine Fracture Pilot Site

Our team has conducted electromagnetic (EM) surveys for the past six years to monitor hydraulic-fracture behavior at the Devine Fracture Pilot Site (DFPS). The sub-horizontal orientation of a shallow hydraulic fracture at the DFPS provides uniform access to the fracture area for interrogation and data collection. Ahmadian et al. (2023) suggested a possible correlation between spatiotemporal changes in the flow rate, bottomhole pressure (BHP), and the observed surface recorded electric field at the DFPS. In this paper, we present the development of poroelastic forward models and pressure transient analyses (PTAs) to support the development of a multiphysics inverse model for these EM surveys. First, we conducted PTAs of the shut-in periods after six injections out of 10 to determine the fracture closure pressure (FCP) or the overburden pressure used in a poroelastic fracture reopening model. Second, we developed a finite-element poroelastic model throughout five injection cycles to include the effect of the cumulative injected volumes due to the previous injections on current fracture dilation in the presence of highly permeable unpropped and propped zones adjacent to the cohesive layer that models fracture reopening. Fracture reopening in this poroelastic model is based on a calibrated traction-separation response using the bottomhole pressure collected in two injection campaigns in 2020 and 2022. We used the outcomes of a previous simulation study of the primary hydraulic-fracturing stimulation to define the dimension of an unpropped fracture zone ahead of the propped fracture area. The PTAs led to FCPs consistent with those obtained using the injection data collected at the DFPS in 2020. Further, these analyses showed that at later injections, the fracture closure occurred at a later time with respect to the shut-in time, inferring the effect of cumulative injected volumes in previous injections. The simulation results show that considering the propped and unpropped fracture zones improves our poroelastic model in predicting the injection-well BHP. The numerical simulation results demonstrate a significant excess pore pressure near the fracture because of the preceding formation loadings by the previous injections. The obtained fracture dilation area and fluid pressure distribution provide a basis to improve the development of a multiphysics inverse model. Furthermore, in an iteratively coupled scheme, this pressure distribution can be introduced into EM models to render a holistic view of the causative mechanisms for the surface signal anomalies.

02 PETROLEUM↗

Erosion-Corrosion Detection in Carbon Steel Pipe Loops using SRNLs Thickness and Mass Loss Measurement Coupons - 20464

Structural health of waste transfer infrastructure is of utmost importance to DOE and communities surrounding their active sites. A Fitness-for-Service (FFS) program for the Waste Transfer System has been implemented by the US Department of Energy (DOE) for the purposes of evaluating and quantifying the degradation of critical components. Currently, the method of approach is to section and evaluate pipelines that have been removed at end service. In order to augment data collection methods applied to making lifespan estimates of waste transfer system components, Florida International University (FIU) has been investigating new-technology based strategies for quantifying the rate of degradation. Present research considers the option of a coupon system installed on a section of pipe at points of interest that will provide easy access to high resolution measurements of erosion/corrosion rates during operation. Researchers at Savannah River National Laboratory (SRNL) have developed this novel solution for in situ erosion and corrosion measurements in many applicable locations such as tanks, pipes, ducts, and injection points. The coupons are approximately 12.7 mm (1/2 inch) in diameter and 25.4 mm (1 inch) in length and can be placed in the pipe sections using Swagelok compression fittings. The coupon design allows for monitoring of the total degradation resulting from corrosion and erosion. High-resolution Ultrasonic Thickness (UT) testing allows in-situ monitoring of both degradation mechanisms. When removed from the system mass loss resulting from corrosion and erosion may also be evaluated. Experimental testing at FIU implemented the SRNL coupon system in a 6.10 meter (20 foot) pipe loop system comprised of 50.8 mm (2 inch) and 76.2 mm (3 inch) pipe sections in order to replicate expected use cases at the sites. Operational conditions were emulated by pumping abrasive materials through the pipeline at full capacity and collecting measurements from the SRNL coupons. Initial testing was conducted by circulating water followed by a mixture of sand and water for uniform wear rates. Thickness changes and mass loss were measured, and the surface exposed to the process fluid was observed for visual evidence of characteristic wear patterns resulting from an erosive environment. The test matrix consisted of several hours of operation and using fine, medium and coarse grain sands. Test results were analyzed to check for all three parameters (mass loss/gain, thickness change and surface patters) which could provide estimates of the remaining useful life of the pipe sections. Thus, the research presents the findings of this evaluation of the SRNL coupons as a means for conducting high accuracy, cost effective in-situ analysis of pipeline and waste transfer systems for erosion and corrosion susceptibility. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantifying Properties for a Mechanistic, Predictive Understanding of Aqueous Impact on Aging of Medium and Low Voltage AC and DC Cabling in Nuclear Power Plants

To address the gap in knowledge in understanding degradation in relevant service conditions, this project aimed to develop a mechanistic, predictive model of medium and low voltage cable failure based on the primary environmental degradation parameters of aqueous immersion time, temperature, and the oxidation extent. To do so, we took a two-fold approach toward evaluating degradation as related to the aqueous condition. First, we evaluated the chemical, mechanical, and electrical properties of polymers that comprise the cabling insulation under varied aqueous conditions at different temperatures. Secondly, we evaluated the performance of insulation materials under similar accelerated aging conditions in addition to the dielectric breakdown of the cabling under submersion conditions. Thermal oxidation and immersion of LDPE thin films were done using a Parr vessel and the extent of oxidation was monitored using the carbonyl index from ATR-FTIR spectrum, a ratio quantifying the carbonyl functionality produced on the LDPE film surface. Increasing the temperature, oxidation time, and oxygen pressure increased the water-vapor permeability and the carbonyl content. Thermogravimetric analysis of the films confirmed that there is indeed an initial weight loss of the smaller molecular weight molecules and volatiles. At higher temperatures, there is a secondary mass loss. Up to 70°C, the mass loss curves were similar until 80°C, when the aged films decreased at a much greater rate with respect to increasing temperature. This was seen in the 10, 50, 90% weight loss temperatures. The mechanical properties of sheet PP and HDPE as well as injection molded LDPE, HDPE, HDPP dog bones were plotted with respect to the time spent in the Parr vessel during thermal oxidation. For the sheet PP and HDPE, the UTS and the modulus of elasticity decreased while the elongation increased. The injection-molded LDPE, HDPE, and HDPP dog bones experienced a similar trend where the changes in the properties were within experimental uncertainty. This analysis of LDPE in dry and immersive oxygen-rich environments is an important baseline for future experiments looking at other degradation mechanisms. A predictive aging model for low-density polyethylene insulative cable housings was developed. This model revealed a combination of physical and chemical processes which lead to an increase in permeability and a decrease in strength of the insulator. In creating this predictive model, a gap of knowledge in the literature was revealed in two areas: understanding how the crystallinity of a polymer changes with time and visualizing the predicted pores formed through the insulator which leads to failure. Developing and using an adapted ATR-FTIR method, crystallinity was monitored and compared to bulk crystallinity found via DSC. Inhomogeneity in crystallinity changes were observed but the FTIR method but was found to be less reliable. Pore visualization was found utilizing electrical impedance spectroscopy saturated aged polyethylene films with synthesized citrate-capped gold nanoparticles, and chloroauric acid precursor. results indicate a decreasing impedance of the polyethylene films caused by the transport of ions through the film. SEM imaging was then performed for elemental analysis of the films and counter electrodes for the presence of ions. Chloride and gold ions were detected; however, no nanoparticles were found. This gives an estimated pore size of at least 0.3 nm through the aged film. Cyclic submergence of polyethylene and polypropylene in aqueous solutions of copper sulfate and Harrison’s solution were examined. It was discovered that aging in these mixed conditions and at 90°C did cause a small, yet significant increase to tensile strength for both unaged polyethylene and polypropylene. The PE and PP in cycled and submerged conditions did not have tensile strengths significantly different from dry-aged after 16 weeks. For both solutions, it was determined that capacitance increases with both water tree depth and cable temperature and is relatively independent of changing water tree AR. As for resistance, there is no apparent change between depth percentages of 10 and 80 for both solutions. This is because the water tree has not yet entered the conductor and thus there is no shorting current flowing through the tree yet. Between 80 and 100% water tree depth, it is observed that for both solutions there is a rapid decrease in resistance because the tree is now impacting the conductor shield and allowing shorting current to flow through it. The relationship between resistance and temperature was found to be inversed. As temperature increases, resistance decreases for both water tree solutions with distilled water having the most apparent difference across the range of temperatures simulated. With regards to water tree AR, resistance was found to be relatively independent at depth percentages of 10, 50, and 70, but there was some relationship at 100% depth for both solutions. At this depth, as water tree AR increased, resistance was found to also increase. Through the examination of voltage and electric field distribution plots, it was confirmed for EPR cables that increasing water tree depth leads to increasing distortion. The increase in shorting current at 100% depth for aqueous copper sulfate compared to distilled water was also visualized. Lastly, the relationship between shorting current and temperature for narrow water trees was visualized and validated using the distribution plots. This study has led to a better understanding of the effect of cable temperature, water tree solution, and geometry of the tree region on cable degradation. Furthermore, this study has documented simulation results of water tree degradation in EPR MV cables, which had been previously lacking in information. Future work in this area will add frequency into the mix and examine what effect it has on the rate of cable degradation as a result of water treeing. To compliment the work being carried by UMD on different polymer chemistries, harvested medium voltage (MV) cables were selected for accelerated aging study at ORNL. These medium voltage cables are representative of the vintages and materials that are currently in use at existing nuclear power plants (NPPs). These cables were immersed in water at 90°C and energized for a period of two years at elevated voltage. Partial discharge was measured during this period of time to track potential degradation. Unfortunately, due to the absence of failure, the extent of integration between the UMD techniques and the harvested MV insulation was limited. However, based on the findings and from the UMD research in the previous sections on polyethylene and polypropylene, follow-on characterization for harvested MV cable insulation should focus on sample preparation to take advantage of the UMD techniques to better understand mechanistic degradation in MV cable insulations. This would include: 1.) Utilization of solutions and impedance measurement insulation to track permeability in harvested and accelerated aging insulation samples, 2.) Adaptation of gold nanoparticle synthesis for electrical impedance spectroscopy with supporting SEM characterization to study pore formation in harvested and accelerated aged insulation samples, & 3.) ATR-FTIR crystallinity with multiple temperature dependent harvested MV cable insulation under different air and submerged accelerated aging. In addition, low voltage dielectric spectroscopy and high voltage dissipation factor, tan δ, could be implemented as a condition monitoring tool for harvested MV cable insulation in submerged environments.

24 POWER TRANSMISSION AND DISTRIBUTION↗