Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “injection pressure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Verification of a three-dimensional resin transfer molding process simulation model

Experimental evidence was obtained to complete the verification of the parameters needed for input to a three-dimensional finite element model simulating the resin flow and cure through an orthotropic fabric preform. The material characterizations completed include resin kinetics and viscosity models, as well as preform permeability and compaction models. The steady-state and advancing front permeability measurement methods are compared. The results indicate that both methods yield similar permeabilities for a plain weave, bi-axial fiberglass fabric. Also, a method to determine principal directions and permeabilities is discussed and results are shown for a multi-axial warp knit preform. The flow of resin through a blade-stiffened preform was modeled and experiments were completed to verify the results. The predicted inlet pressure was approximately 65% of the measured value. A parametric study was performed to explain differences in measured and predicted flow front advancement and inlet pressures. Furthermore, PR-500 epoxy resin/IM7 8HS carbon fabric flat panels were fabricated by the Resin Transfer Molding process. Tests were completed utilizing both perimeter injection and center-port injection as resin inlet boundary conditions. The mold was instrumented with FDEMS sensors, pressure transducers, and thermocouples to monitor the process conditions. Results include a comparison of predicted and measured inlet pressures and flow front position. For the perimeter injection case, the measured inlet pressure and flow front results compared well to the predicted results. The results of the center-port injection case showed that the predicted inlet pressure was approximately 50% of the measured inlet pressure. Also, measured flow front position data did not agree well with the predicted results. Possible reasons for error include fiber deformation at the resin inlet and a lag in FDEMS sensor wet-out due to low mold pressures.

Fingerson, John C.↗

Quantitative characterization of a nonreacting, supersonic combustor flowfield using unified, laser-induced iodine fluorescence

A calibrated, nonintrusive optical technique, laser-induced iodine fluorescence (LIIF) was used to quantify the steady, compressible flowfield of a nonreacting, supersonic combustor. The combustor was configured with single and staged, transverse-air injection into a supersonic-air freestream behind a rearward-facing step. Pressure, temperature, two-velocity components, and injectant mole fraction were measured with high spatial resolution in the three-dimensional flowfields. These experimental results provide a benchmark set of data for validation of computational fluid dynamic (CFD) codes being developed to model supersonic combustor flowfields.

Fletcher, D. G.↗

Numerical Investigation of Two-Stage Vapor Compression System with Simultaneous Vapor and Liquid Injection

Two-stage vapor compression systems can be advantageous over single-stage systems by providing improved system performance, lower discharge temperature and reduced throttling losses. These systems employ various intermediate configurations, such as liquid injection and vapor injection. This paper presents a configuration for a R1234ze(E) two-stage air-conditioning system using a turbo compressor with two injection ports, one for vapor injection and the second for liquid injection. The liquid injection is used to cool the motor and electronics. A component-based representation and solution approach was used to simulate the two-stage compression system with simultaneous vapor and liquid injection at steady state. The turbo compressor was represented using a customized performance map. The condenser and the evaporator were modeled using finite-volume approach. A parametric study was conducted to assess the impact of the following three variables on the system performance: vapor injection ratio, condenser air flow rate, and discharge pipe pressure drop. The simulation results show that as the vapor injection ratio increased, the system performance undergoes a tradeoff between an enhanced subcooling effect (and thus enhanced unit refrigeration capacity) and a decreased suction mass flow rate. Maximum COP occurs when the vapor injection ratio was 0.1. The results also show that as the condenser air flow rate increased, both the capacity and power consumption (including fan power) increased monotonically, and COP increased first and then decreased. At 75% load, the COP improvement at the optimum flow rate was marginally less than 0.5%. Lastly, higher discharge pipe pressure drop increased the discharge pressure. It showed very small effect on the overall system performance at the condition selected for the current study.

component-based steady-state simulation↗

Utah FORGE 2439: Well 16B(78)-32 Field-Test Data from Mini-Frac Tests

This submittal includes the field-test data collected during stress tests conducted in the Utah FORGE 16B(78)-32 wellbore to measure/characterize the stresses in the geothermal reservoir. The type of stress test performed is referred to as a mini-frac test or a micro-frac test. The test is a hydraulic fracture test that involves injecting a small volume of water into a short interval of the reservoir that is isolated by a straddle packer to create a fracture. The test provides information about the minimum and maximum horizontal stress at the test depths. A total of seven mini-frac tests were performed within the upper (vertical or nearly vertical) section of the 9-5/8-inch diameter uncased wellbore, between depths of 5,202 ft MD [5,202 ft TVD] and 5,980 ft MD [5966.18 ft TVD]. Two types of data were generated as part of the mini-frac tests. The first type of data is time-series data for each mini-frac test (e.g., injection-rate, test-interval pressure), and are contained in the "Mini-Frac Test Data.zip" file below. The second type is geophysical log data, attached below in the "Geophysical Logs.zip" file. Here, two types of image logs and acoustic logs were obtained before and after the mini-frac tests to examine each test depth for visual evidence of induced fracture(s) and to measure the azimuth (orientation) of any observed fractures. The attached Readme file includes the test depth information and contents of each data file included here. Analysis of the field-test data was conducted and is documented in the attached report below.

15 GEOTHERMAL ENERGY↗

A workflow to assess the efficacy of brine extraction for managing injection-induced seismicity potential using data from a CO 2 injection site near Decatur, Illinois

Injection of CO 2 for storage in a geologic formation increases pore pressure and alters in situ stresses. Depending on the orientation of any existing fault and fracture planes, such as critically stressed planes, this stress alteration will modify normal stresses acting on planes and could result in frictional sliding and release stored energy in the form of seismicity. Brine extraction (BE) is a technique that can be applied prior to, or during, CO 2 injection to reduce pore pressure for increasing storage capacity and, potentially, for reducing the likelihood of frictional sliding. Here a workflow is described to assess the efficacy of BE for mitigating frictional sliding (i.e., seismicity) during injection and entails: site characterization, stress calculations and failure assessment, static and dynamic modeling, and BE operational planning. Site characterization describes the stress field used to calculate the Coulomb Failure Function (CFF) that constrains allowable pore pressure changes and injection rates in the numerical simulation of CO 2 injection scenarios. The inclusion of BE in the workflow allows for determination of the potential need for pressure reduction, and evaluation of the effectiveness of this operation. Example application of the workflow using an injection field dataset near Decatur, IL, provides insight on fracture planes and stresses at the site, formation properties and the impact of variable CO 2 injection-rate targets on whether BE plans are required. The study workflow indicates that BE could enhance CO 2 injection rate by 39% and correspondingly reduce the potential for injection-induced seismicity as indicated by a reduction in CFF.

58 GEOSCIENCES↗

Transportability of exogenous microbial community correlates with interwell connectivity in deep aquifers

Subsurface resource engineering operations often utilize continuous injection of externally-sourced water into geological reservoirs for formation pressure maintenance, resource recovery or energy/waste storage. Such injected water generally contains naturally occurring microbes. Little is known, however, about how the injectate microbes transport through geological media as a community, how such transportability is affected by injector-producer connectivity, and whether such knowledge can be utilized for flowpath characterization. In this study, we analyzed daily-to-weekly timeseries microbial community data from the injected- and produced-fluids of a ten-month flow test at a deep, well-characterized engineered aquifer. We found that the injectate microbial community was distinct from the indigenous community at the amplicon sequence variant (ASV) level, and that the transportability of injectate community towards a given producer, quantified by an “nASV-Overlap” metric we propose, had strong and significant positive correlation with known injector-producer connectivities at our site. This suggests that the better the connectivity, the higher the probability for more injectate species to flow through the interwell region and arrive at a producer. Because interwell connectivity is an important yet usually unknown parameter in subsurface resource engineering, such correlation in turn points to nASV-Overlap as a useful indicator of interwell connectivity for aquifer characterization and long-term monitoring. Based on our findings, an nASV-Overlap-based microbial tracing approach was developed for characterizing and monitoring the relative connectivities across multiple producers with a given injector. A side-by-side comparison between the new nASV-Overlap approach and traditional artificial tracer methods is presented, and their respective strengths and limitations are discussed.

Deep biosphere↗

Portable Liquid-Injecting System

Portable injecting-gun system dispenses predetermined amount of liquid at moderately high pressure. Tool belt holds components of liquid-injecting system. Pump and four-way valve combined in nylon housing. Connected to injecting nozzle and other components by polyvinyl tubing.

Shuck, T.↗

Propulsion Simulations with the Unstructured-Grid CFD Tool TetrUSS

A computational investigation has been completed to assess the capability of the NASA Tetrahedral Unstructured Software System (TetrUSS) for simulation of exhaust nozzle flows. Three configurations were chosen for this study: (1) a fluidic jet effects model, (2) an isolated nacelle with a supersonic cruise nozzle, and (3) a fluidic pitchthrust- vectoring nozzle. These configurations were chosen because existing data provided a means for measuring the ability of the TetrUSS flow solver USM3D for simulating complex nozzle flows. Fluidic jet effects model simulations were compared with structured-grid CFD (computational fluid dynamics) data at Mach numbers from 0.3 to 1.2 at nozzle pressure ratios up to 7.2. Simulations of an isolated nacelle with a supersonic cruise nozzle were compared with wind tunnel experimental data and structured-grid CFD data at Mach numbers of 0.9 and 1.2, with a nozzle pressure ratio of 5. Fluidic pitch-thrust-vectoring nozzle simulations were compared with static experimental data and structured-grid CFD data at static freestream conditions and nozzle pressure ratios from 3 to 10. A fluidic injection case was computed with the third configuration at a nozzle pressure ratio of 4.6 and a secondary pressure ratio of 0.7. Results indicate that USM3D with the S-A turbulence model provides accurate exhaust nozzle simulations at on-design conditions, but does not predict internal shock location at overexpanded conditions or pressure recovery along a boattail at transonic conditions.

Deere, Karen A.↗

Pressure falloff testing to characterize CO 2 plume and dry-out zone during CO 2 injection in saline aquifers

The fluid mobilities and the lateral extent of the CO 2 plume and the dry-out zone are among important unknowns required to effectively manage CO 2 storage in saline aquifers projects. These unknowns can be derived from pressure falloff testing which has been widely used to characterize the subsurface. This paper provides a three-region analytical solution for falloff pressure during the infinite-acting period of CO 2 injection in saline aquifers. The solution is derived using Laplace transformation technique of the governing diffusivity equations and the accompanying initial and boundary conditions. The exact solution is validated against numerical results obtained from a black-oil reservoir simulator for two cases. The solution is approximated into simple forms in real-time domain considering different time periods. Then, a graphical semi-log analysis technique based on the approximate solutions is provided as an interpretation tool of falloff tests where the fluid mobilities and the extents of dry-out zone and CO 2 plume can be inferred. The interpretation technique is applied to synthetic falloff test data to investigate its potential and reliability.

02 PETROLEUM↗

NRAP-Open-IAM Analytical Reservoir Model: Development and Testing

Geological carbon sequestration (GCS) is a key technology for reducing global carbon dioxide (CO 2 ) emissions. Over the last decade, the U.S. Department of Energy has invested in understanding the science base, developing practical implementation methods, and demonstrating secure GCS technologies to mitigate the environmental impacts associated with the atmospheric release of CO 2 . As part of the National Risk Assessment Partnership, a systems-level risk assessment tool, called the NRAP-Open-IAM, has been developed to conduct risk assessment and enable safe operations at a GCS site. The current NRAP-Open-IAM contains a simple reservoir model component that calculates the evolution of CO 2 saturation and fluid pressure in a storage reservoir during CO 2 injection operations. This report presents the development and testing of a new analytical reservoir reduced-order model (ROM), which is extended from an existing semi-analytical model for estimation of CO 2 and brine leakage along legacy wells, and enhances the capability of the NRAP-Open-IAM to simulate more types of reservoir conditions. The developed model is validated against three reference studies, and the results indicate that the new ROM predicts the behavior of the two-phase fluids (brine and injected CO 2 ) well and is applicable to different reservoir simulation boundary conditions (i.e., constant pressure boundary and infinite-acting boundary) without a priori user specification of the boundary type. Sensitivity analysis for a set of model parameters is performed using 4,000 synthetic cases prepared via a fully automated process and using machine-learning-based feature selection. The stochastic analysis identifies gravitational number (i.e., ratio of gravitational forces to viscous force) and distance between the injection well and observation location as the most impactful parameters for matching the pressure and CO 2 saturation, respectively, between the numerical simulations and the ROM. This report details the possible ROM uncertainties and serves as a guide for users to understand the use and limitations of this ROM. The code implementation of the model will be released as a module within the NRAP-Open-IAM.

54 ENVIRONMENTAL SCIENCES↗

Active Flow Separation Control of a Stator Vane Using Surface Injection in a Multistage Compressor Experiment

Micro-flow control actuation embedded in a stator vane was used to successfully control separation and improve near stall performance in a multistage compressor rig at NASA Glenn. Using specially designed stator vanes configured with internal actuation to deliver pulsating air through slots along the suction surface, a research study was performed to identify performance benefits using this microflow control approach. Pressure profiles and unsteady pressure measurements along the blade surface and at the shroud provided a dynamic look at the compressor during microflow air injection. These pressure measurements lead to a tracking algorithm to identify the onset of separation. The testing included steady air injection at various slot locations along the vane. The research also examined the benefit of pulsed injection and actively controlled air injection along the stator vane. Two types of actuation schemes were studied, including an embedded actuator for on-blade control. Successful application of an online detection and flow control scheme will be discussed. Testing showed dramatic performance benefit for flow reattachment and subsequent improvement in diffusion through the use of pulsed controlled injection. The paper will discuss the experimental setup, the blade configurations, and preliminary CFD results which guided the slot location along the blade. The paper will also show the pressure profiles and unsteady pressure measurements used to track flow control enhancement, and will conclude with the tracking algorithm for adjusting the control.

Culley, Dennis E.↗

Pellet triggering of edge localized modes in low collisionality pedestals at DIII-D

Edge localized modes (ELMs) are triggered using deuterium pellets injected into plasmas with ITER-relevant low collisionality pedestals, and the resulting peak ELM energy fluence is reduced by approximately 25%–50% relative to natural ELMs destabilized at similar pedestal pressures. Cryogenically frozen deuterium pellets are injected from the low-field side of the DIII-D tokamak at frequencies lower than the natural ELM frequency, and heat flux is measured by infrared cameras. Ideal MHD pedestal stability calculations show that without pellet injection, these low collisionality pedestals were limited by their current density (peeling-limited) rather than their pressure gradient (ballooning-limited). ELM triggering success correlates strongly with pellet mass, consistent with the theory that a large pressure perturbation is required to trigger an ELM in low collisionality discharges that are far from the ballooning stability boundary. For sufficiently large pellets, both instantaneous and time-integrated ELM energy deposition measured by infrared cameras is reduced with respect to naturally occurring ELMs at the inner strike point, which is the position where it is largest for natural ELMs. Energy fluence at the outer strike point is less effected. Cameras observing both heat flux and D-alpha emission often find significant toroidally asymmetric striations in the outboard far scrape-off layer resulting from ELMs that are triggered by pellets. Toroidal asymmetries at the inner strike point are similar between natural and pellet-triggered ELMs, indicating that the reduction in peak heat flux and total fluence at that location is robust for the conditions reported here.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploratory development of foams from liquid crystal polymers

Two types of liquid crystal polymer (LCP) compositions were studied and evaluated as structural foam materials. One is a copolymer of 6-hydroxy-2-naphthoic acid, terephthalic acid, and p-acetoxyacetanilide (designed HNA/TA/AAA), and the other is a copolymer of p-hydroxybenzoic acid and 6-hydroxy-2-naphthoic acid (designated HBA/HNA). Experimental results showed that the extruded HNA/TA/AA foams have better mechanical quality and appearance than HBA/HNA foams. Heat treatment improved foam tensile strength and break elongation, but reduced their modulus. The injection molding results indicated that nitrogen foaming agents with a low-pressure process gave better void distribution in the injection molded LCP foams than those made by the conventional injection-molding machine and chemical blowing agents. However, in comparing LCP foams with other conventional plastic foams, HBA/HNA foams have better mechanical properties than foamed ABS and PS, but are comparable to PBT and inferior to polycarbonate foams, especially in heat-deflection temperature and impact resistance energy. These deficiencies are due to LCP molecules not having been fully oriented during the Union-Carbide low-pressure foaming process.

Chung, T. S.↗

Multi-injection investigation of a high-volatility diesel in advanced compression ignition combustion for NO x control

Traditional selective catalytic reduction aftertreatment technologies used to reduce [Formula: see text] are very limited at exhaust temperatures below [Formula: see text]. Therefore, under these low engine load conditions, having effective in-cylinder control of [Formula: see text] emissions is important. Previous work by the authors explored the effect of fuel physical properties on the ability to control [Formula: see text] in-cylinder. That work was limited to one direct injection near top dead center. Modern diesel high-pressure fuel systems have the capability of five or more injections in one engine cycle. A higher-volatility diesel fuel and high amounts of exhaust gas recirculation to delay ignition could provide an opportunity for reduction in engine-out [Formula: see text] through an increased level of fuel premixing. By appropriately timing multiple short injections, a more optimal distribution of fuel in-cylinder may be achieved, which could reduce [Formula: see text] while maintaining an efficient combustion phasing. A computational fluid dynamics model previously validated against experimental data was used to explore several injection strategies with increased levels of fuel premixing to assess the potential trade-offs between [Formula: see text] and CO/unburned hydrocarbon (UHC) emissions and thus reduce reliance on the aftertreatment system for [Formula: see text] control. The results show that the devised injection strategies resulted in an increased level of fuel premixing. However, none of the attempted injection strategies resulted in significant [Formula: see text] reductions, and all strategies showed a significant increase in CO and UHC emissions.

33 ADVANCED PROPULSION SYSTEMS↗

Lewis Research Center's coal-fired, pressurized, fluidized-bed reactor test facility

A 200-kilowatt-thermal, pressurized, fluidized-bed (PFB) reactor, research test facility was designed, constructed, and operated as part of a NASA-funded project to assess and evaluate the effect of PFB hot-gas effluent on aircraft turbine engine materials that might have applications in stationary-power-plant turbogenerators. Some of the techniques and components developed for this PFB system are described. One of the more important items was the development of a two-in-one, gas-solids separator that removed 95+ percent of the solids in 1600 F to 1900 F gases. Another was a coal and sorbent feed and mixing system for injecting the fuel into the pressurized combustor. Also important were the controls and data-acquisition systems that enabled one person to operate the entire facility. The solid, liquid, and gas sub-systems all had problems that were solved over the 2-year operating time of the facility, which culminated in a 400-hour, hot-gas, turbine test.

Kobak, J. A.↗

Modeling of fluid injection-induced fault reactivation using coupled fluid flow and mechanical interface model

The present study is aimed at developing a numerical model to reproduce coupled hydro-mechanical processes associated with fault reactivation by fluid injection in low permeability rock, as part of the DECOVALEX-2019 project Task B. We proposed a modeling approach for simulating the processes using the TOUGH-FLAC simulator, and modeled a fault reactivation experiment conducted at Mont Terri Rock Laboratory in Switzerland. The first step of the study involved benchmark calculations considering a simplified fault plane and geometry. Fluid flow along a fault was modeled using elements of aperture-sized thickness on the basis of Darcy's law and the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by zero-thickness interface elements in FLAC3D upon which a slip and/or separation is allowed. A methodology to connect a TOUGH2 volume element to a FLAC3D interface element was developed for handling the hydro-mechanical interactions on the fault during fluid injection. Two different fault models for describing the evolutions of hydraulic aperture by elastic fracture opening and failure-induced aperture increase were considered in the benchmark calculations. In the coupling process, the changes in geometrical features and hydrological properties induced by mechanical deformation were continuously updated. The transient responses of the fault and host rock to stepwise pressurization were examined during the simulation. The hydro-mechanical behavior, including the injection flow rate, pressure distribution around the borehole, stress conditions, and displacements in normal and shear directions were monitored in the surrounding rock and along the fault. The results of benchmark calculations suggest that the developed model reasonably represents the hydro-mechanical behavior of a fault and the surrounding rock. This modeling approach was applied to the fault reactivation experiment of the Mont Terri Rock Laboratory. In this interpretive modeling, a parametric study was conducted to examine the effects of input parameters regarding in situ stress and fault properties on the hydro-mechanical responses of the fault to water injection. Then, an optimal parameter set to reproduce the field experiment results was chosen by trial-and-error. The injection flow rate and pressure response during fault reactivation closely matched those obtained at the site, which indicates the capability of the model to appropriately capture the progressive pathway evolution during fault reactivation tests at the site. Finally, the anchor displacements were overestimated by the model, but a fair agreement was obtained in terms of the order of magnitude and the variation tendency.

58 GEOSCIENCES↗

Fluidic Control of Nozzle Flow: Some Performance Measurements

Results are presented of an experimental program that investigated the use of a secondary air stream to control the amount of flow through a convergent-divergent nozzle. These static tests utilized high pressure, ambient temperature air that was injected at the throat of the nozzle through an annular slot. Multiple injection slot sizes and injection angles were tested. The introduction of secondary flow was made in an opposing direction to the primary flow and the resulting flow field caused the primary stream to react as though the physical throat size had been reduced. The percentage reduction in primary flow rate was generally about twice the injected flow rate. The most effective throttling was achieved by injecting through the smallest slot in an orientation most nearly opposed to the approaching primary flow. Thrust edliciency, as measured by changes in nozzle thrust coefficient, was highest at high nozzle pressure ratios, NPR. The static test results agreed with predictions obtained prior from PABSD, a fully viscous computational fluid dynamics program. Since use of such an injection system on gas turbine engine exhaust nozzles would be primarily at high NPRs, it was concluded that fluidic control holds promise for reducing nozzle weight and complexity on future systems.

Federspiel, John↗