Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “image understanding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Atomic Force Microscopy to Characterize Antimicrobial Peptide-Induced Defects in Model Supported Lipid Bilayers

Antimicrobial peptides (AMPs) interact with bacterial cell membranes through a variety of mechanisms, causing changes extending from nanopore formation to microscale membrane lysis, eventually leading to cell death. Several AMPs also disrupt mammalian cell membranes, despite their significantly different lipid composition and such collateral hemolytic damage hinders the potential therapeutic applicability of the AMP as an anti-microbial. Elucidating the mechanisms underlying the AMP–membrane interactions is challenging due to the variations in the chemical and structural features of the AMPs, the complex compositional variations of cell membranes and the inadequacy of any single experimental technique to comprehensively probe them. (1) Background: Atomic Force Microscopy (AFM) imaging can be used in combination with other techniques to help understand how AMPs alter the orientation and structural organization of the molecules within cell membranes exposed to AMPs. The structure, size, net charge, hydrophobicity and amphipathicity of the AMPs affect how they interact with cell membranes of differing lipid compositions. (2) Methods: Our study examined two different types of AMPs, a 20-amino acid, neutral, α-helical (amphipathic) peptide, alamethicin, and a 13-amino acid, non-α-helical cationic peptide, indolicidin (which intramolecularly folds, creating a hydrophobic core), for their interactions with supported lipid bilayers (SLBs). Robust SLB model membranes on quartz supports, incorporating predominantly anionic lipids representative of bacterial cells, are currently not available and remain to be developed. Therefore, the SLBs of zwitterionic egg phosphatidylcholine (PC), which represents the composition of a mammalian cell membrane, was utilized as the model membrane. This also allows for a comparison with the results obtained from the Quartz Crystal Microbalance with Dissipation (QCM-D) experiments conducted for these peptides interacting with the same zwitterionic SLBs. Further, in the case of alamethicin, because of its neutrality, the lipid charge may be less relevant for understanding its membrane interactions. (3) Results: Using AFM imaging and roughness analysis, we found that alamethicin produced large, unstable defects in the membrane at 5 µM concentrations, and completely removed the bilayer at 10 µM. Indolicidin produced smaller holes in the bilayer at 5 and 10 µM, although they were able to fill in over time. The root-mean-square (RMS) roughness values for the images showed that the surface roughness caused by visible defects peaked after peptide injection and gradually decreased over time. (4) Conclusions: AFM is useful for helping to uncover the dynamic interactions between different AMPs and cell membranes, which can facilitate the selection and design of more efficient AMPs for use in therapeutics and antimicrobial applications.

Swana, Kathleen W.↗

Image interpretation and prediction in microwave diversity imaging

The microwave image of a metallic object is interpreted from a point of view based on the understanding of the interconnection between the scattering mechanisms, the data acquisition system, and the image reconstruction algorithm. From this understanding it is possible to interpret and predict microwave images reconstructed from data collected over specified and angular windows. The connection between a special scattering mechanism, edge diffraction, and its reconstructed image is established. The microwave image of an edge is two bright points whose locations correspond to the end points of the edge if the normal aspect angle is not included in the angular windows; otherwise a line joining the two end points and representing the edge will appear in the image. Experimental images of a trihedral reflector constructed from data collected over different angular windows support this approach to image interpretation and prediction.

Li, Hsueh-Jyh↗

3D X-Ray Luggage-Screening System

A three-dimensional (3D) x-ray luggage- screening system has been proposed to reduce the fatigue experienced by human inspectors and increase their ability to detect weapons and other contraband. The system and variants thereof could supplant thousands of xray scanners now in use at hundreds of airports in the United States and other countries. The device would be applicable to any security checkpoint application where current two-dimensional scanners are in use. A conventional x-ray luggage scanner generates a single two-dimensional (2D) image that conveys no depth information. Therefore, a human inspector must scrutinize the image in an effort to understand ambiguous-appearing objects as they pass by at high speed on a conveyor belt. Such a high level of concentration can induce fatigue, causing the inspector to reduce concentration and vigilance. In addition, because of the lack of depth information, contraband objects could be made more difficult to detect by positioning them near other objects so as to create x-ray images that confuse inspectors. The proposed system would make it unnecessary for a human inspector to interpret 2D images, which show objects at different depths as superimposed. Instead, the system would take advantage of the natural human ability to infer 3D information from stereographic or stereoscopic images. The inspector would be able to perceive two objects at different depths, in a more nearly natural manner, as distinct 3D objects lying at different depths. Hence, the inspector could recognize objects with greater accuracy and less effort. The major components of the proposed system would be similar to those of x-ray luggage scanners now in use. As in a conventional x-ray scanner, there would be an x-ray source. Unlike in a conventional scanner, there would be two x-ray image sensors, denoted the left and right sensors, located at positions along the conveyor that are upstream and downstream, respectively (see figure). X-ray illumination may be provided by a single source or by two sources. The position of the conveyor would be detected to provide a means of matching the appropriate left- and right-eye images of an item under inspection. The appropriate right- and left-eye images of an item would be displayed simultaneously to the right and left eyes, respectively, of the human inspector, using commercially available stereo display screens. The human operator could adjust viewing parameters for maximum viewing comfort. The stereographic images thus generated would differ from true stereoscopic images by small distortions that are characteristic of radiographic images in general, but these distortions would not diminish the value of the images for identifying distinct objects at different depths.

Fernandez, Kenneth↗

Remote Sensing of Terrestrial Snow and Ice for Global Change Studies

Snow and ice play a significant role in the Earth's water cycle and are sensitive and informative indicators climate change. Significant changes in terrestrial snow and ice water storage are forecast, and while evidence of large-scale changes is emerging, in situ measurements alone are insufficient to help us understand and explain these changes. Imaging remote sensing systems are capable of successfully observing snow and ice in the cryosphere. This chapter examines how those remote sensing sensors, that now have more than 35 years of observation records, are capable of providing information about snow cover, snow water equivalent, snow melt, ice sheet temperature and ice sheet albedo. While significant progress has been made, especially in the last five years, a better understanding is required of the records of satellite observations of these cryospheric variables.

Kelly, Richard↗

Dosimetric and biological impact of activity extravasation of radiopharmaceuticals in PET imaging

The increasing use of nuclear medicine and PET imaging has intensified scrutiny of radiotracer extravasation. To our knowledge, this topic is understudied but holds great potential for enhancing our understanding of extravasation in clinical PET imaging. This work aims to (1) quantify the absorbed doses from radiotracer extravasation in PET imaging, both locally at the site of extravasation and with the extravasation location as a source of exposure to bodily organs and (2) assess the biological ramifications within the injection site at the cellular level. A radiation dosimetry simulation was performed using a whole-body 4D Extended Cardiac-Torso (XCAT) phantom embedded in the GATE Monte Carlo platform. A 10-mCi dose of 18 F-FDG was chosen to simulate a typical clinical PET scan scenario, with 10% of the activity extravasated in the antecubital fossa of the right arm of the phantom. The extravasation volume was modeled as a 5.5 mL rectangle in the hypodermal layer of skin. Absorbed dose contributions were calculated for the first two half-lives, assuming biological clearance thereafter. Dose calculations were performed as absorbed doses at the organ and skin levels. Energy deposition was simulated both at the local extravasation site and in multiple organs of interest and converted to absorbed doses based on their respective masses. Each simulation was repeated ten times to estimate Monte Carlo uncertainties. Biological impacts on cells within the extravasated volume were evaluated by randomizing cells and exposing them to a uniform radiation source of 18 F and 68 Ga. Particle types, their energies, and direction cosines were recorded in phase space files using a separate Geant4 simulation to characterize their entry into the nucleus of the cellular volume. Subsequently, the phase space files were imported into the TOPAS-nBio simulation to assess the extent of DNA damage, including double-strand breaks (DSBs) and single-strand breaks (SSBs). Organ-level dosimetric estimations are presented for 18 F and 68 Ga radionuclides in various organs of interest. With 10% extravasation, the hypodermal layer of the skin received the highest absorbed dose of 1.32 ± 0.01 Gy for 18 F and 0.99 ± 0.01 Gy for 68 Ga. The epidermal and dermal layers received absorbed doses of 0.07 ± 0.01 Gy and 0.13 ± 0.01 Gy for 18 F, and 0.14 ± 0.01 Gy and 0.29 ± 0.01 Gy for 68 Ga, respectively. In the extravasated volume, 18 F caused an average absorbed dose per nucleus of 0.17 ± 0.01 Gy, estimated to result in 10.58 ± 0.50 DSBs and 268.11 ± 12.43 SSBs per nucleus. For 68 Ga, the absorbed dose per nucleus was 0.11 ± 0.01 Gy, leading to an estimated 6.49 ± 0.34 DSBs and 161.24 ± 8.12 SSBs per nucleus. Absorbed doses in other organs were on the order of micro-gray (µGy). The likelihood of epidermal erythema resulting from extravasation during PET imaging is low, as the simulated absorbed doses to the epidermis remain below the thresholds that trigger such effects. Moreover, the organ-level absorbed doses were found to be clinically insignificant across various simulated organs. The minimal DNA damage at the extravasation site suggests that long-term harm, such as radiation-induced carcinogenesis, is highly unlikely.

DNA strand breaks↗

Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-FG-202-07: An MRI-Based Approach to Quantify Radiation-Induced Normal Tissue Injury Applied to Trismus After Head and Neck Cancer Radiotherapy

Purpose: The aim of this study was to investigate if quantitative MRI-derived metrics from four masticatory muscles could explain mouth-opening limitation/trismus following intensity-modulated radiotherapy (IMRT) for head and neck cancer (HNC). Methods: Fifteen intensity-based MRI metrics were derived from the masseter, lateral and medial pterygoid, and temporalis in T1-weighted scans acquired pre- and post gadolinium injection (T1Pre, T1Post) of 16, of in total 20, patients (8 symptomatic; 8 asymptomatic age/sex/tumor location-matched) treated with IMRT to 70 Gy (median) for HNC in 2005–2009. Trismus was defined as “≥decreased range of motion without impaired eating” (CTCAE.v.3: ≥Grade 1). Trismus status was monitored and MRI scans acquired within 1y post-RT. All MRI-derived metrics were assessed as ΔS=S(T1Pre)-S(T1Post)/S(T1Pre), and were normalized to the corresponding metric of a non-irradiated volume defined in each scan. The T1Pre structures were propagated onto the RT dose distribution, and the max and mean dose (Dmax, Dmean) were extracted. The MRI-derived metrics, Dmax, and Dmean were compared between trismus and non-trismus patients. A two-sided Wilcoxon Signed rank test-based p-value≤0.05 denoted significance. Results: For all four muscles the population mean of Dmax and Dmean was higher for patients with trismus compared to patients without trismus (ΔDmax=2.3–4.9 Gy; ΔDmean=and 2.0–3.8 Gy). The standard deviation (SD), the variance, and the minimum value (min) of ΔS were significantly (p=0.04–0.05) different between patients with and without trismus with trismus patients having significantly lower SD (population median: −0.53 vs. −0.31) and variance (−2.09 vs. −0.73) of the masseter, and significantly lower min of the medial pterygoid (−0.36 vs. −0.19). Conclusion: Quantitative MRI-derived metrics of two masticatory muscles were significantly different between patients with and without trismus following RT for HNC. These metrics could serve as image-based biomarkers to better understand the RT-induced etiology behind trismus, but should be further investigated in the complete cohort.

60 APPLIED LIFE SCIENCES↗

Obese patients and radiography literature: what do we know about a big issue?

Obesity is a global health issue with obese patients requiring specialised diagnosis, treatment and care through the health service. The practical and social difficulties associated with medical imaging of obese patients are an increasingly common problem and it is currently unknown how student and qualified radiographers perceive and respond to these challenges. By better understanding challenges presented in providing quality imaging and care of imaging obese patients, education for both qualified and student radiographers can be enhanced. Radiographers are heavily reliant on visual and tactile senses to locate the position of anatomical structures for diagnostic imaging and determine radiation exposure through a delicate consideration of dose, image quality and anatomical attenuation. However, obese patients require modifications to routine radiographic practice in terms of movement/assisted positioning, equipment capabilities to take increased weight or coverage. These patients may also be subject to compromised radiological diagnosis through poor visualisation of structures. In this paper, the professional and educational literature was narratively reviewed to assess gaps in the evidence base related to the skill and care knowledge for obese patients. Literature was sourced relating to discrete radiographic considerations such as the technical factors of imaging obese patients, exposure and the impact of obesity on imaging departments’ service provisions. The recent literature (post-2000 to coincide with the sharp increase in global obesity) on the perceptions of health professionals and student health practitioners has also been explored because there are no specific radiographer studies to report. By understanding the research in similar fields, we may identify what common attitudes qualified and student radiographer's hold and what challenges, technical and care related, can be prepared for.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging Supramolecular Morphogenesis with Confocal Laser Scanning Microscopy at Elevated Temperatures

The morphogenesis of supramolecular assemblies is a highly dynamic process that has only recently been recognized, and our understanding of this phenomenon will require imaging techniques capable of crossing scales. Shape transformations depend both on the complex energy landscapes of supramolecular systems and the kinetically controlled pathways that define their structures and functions. We report here the use of confocal laser scanning microscopy coupled with a custom-designed variable-temperature sample stage that enables in situ observation of such shape changes. The submicrometer resolution of this technique allows for real-time observation of the nanostructures in the native liquid environments in which they transform with thermal energy. We use this technique to study the temperature-dependent morphogenic behavior of peptide amphiphile nanofibers and photocatalytic chromophore amphiphile nanoribbons. Furthermore, the variable-temperature confocal microscopy technique demonstrated in this work can sample a large volume and provides real-time information on thermally induced morphological changes in the solution.

36 MATERIALS SCIENCE↗

Surface Channeling in Aberration-corrected STEM of Nanostructures

Sub- ngstr m resolution imaging and atomic resolution spectroscopy in aberration-corrected STEM are becoming routinely available, providing information on crystal structure, defect structure, elemental composition, and electronic structure with a sensitivity of, or approaching, individual atoms. To quantitatively interpret image intensities, however, requires a better understanding of the origin of the collected signals. We report here observation of anomalous intensity enhancement in sub- ngstr m resolution HAADF images of surfaces and interfaces of ZnO nanostructures. We propose that the significant increase of the collected HAADF signal of a row of atom columns close to the crystal surface originates from a surface-resonance channeling effect [1].

aberration-correction↗

Optical Time Transfer for Bistatic SAR Spacecraft

A spacecraft-to-spacecraft optical time-transfer simulation has been developed as a tool for informing NASA’s Surface Deformation and Change (SDC) mission architecture. The SDC mission will combine radar images from multiple spacecraft to improve understanding of the Earth’s sea-level and landscape changes. Spacecraft must be precisely synchronized in order to create sharp radar images. Simulation of multiple spacecraft time-synchronizing via laser communication can inform technology choices of a mission by providing a picosecond-precision level estimate of clock error. This timing and ranging simulation has been combined with a radar system performance analysis pipeline. The simulated timing errors are used to predict performance of bistatic SAR systems in the presence of oscillator noise and time synchronization in accuracy. This analysis includes both analytic approximation equations from existing literature, and a numerical radar simulation to extract key system performance parameters like phase error and signal-to-noise ratio (SNR)degradation. Precision time-transfer techniques facilitate the accurate synchronization of clocks between any combination of terminals. Most time-transfer technology for comparing two clocks at different terminals use radio frequencies (RF) to measure the time delay between the sending and receiving of signals. Laser technology offers the capability to transmit high data rates with systems that are of smaller size and lower power than comparable RF systems. The clocks on independent spacecraft will have some phase and frequency errors between them that result in clock drift. The two clock models that are included in this bi-directional MATLAB simulation are a cesium-based Chip-Scale Atomic Clock (CSAC) and a rubidium-based Miniature Atomic Clock (MAC). The CSAC has flown as hardware for small satellite missions such as the University of Florida’s CHOMPTT mission. A study of example orbits, including that of NASA NASA-ISRO Synthetic Aperture Radar Mission (NISAR) mission, and lasing rates demonstrate the impact of flight configuration parameters on the synchronization error between two spacecraft. The MATLAB timing simulation uses a Runge-Kutta 4th-order method to propagate spacecraft orbits and computes the light-travel time estimate between them. The simulation outputs the estimated range and estimated clock error based on a user-defined spacecraft cluster configuration. The radar simulation and analytic approximations are applied to evaluate a potential future NASA bistatic SAR constellation architecture. In the proposed architecture, satellites follow each other in the same orbit at 800 km altitude, with a 210 km baseline. We also baseline the CSAC as an ultra stable oscillator, and use NASA’s NISAR for baseline radar system parameters to compute a clock-system introduced phase error of 5.6 degrees without synchronization by frequent time transfer. We build on this base case with a sensitivity analysis of radar performance over a proposed range of constellation and radar system parameters. With this analysis pipeline, we comment on which radar parameters should or should not be changed to minimize synchronization requirements. This analysis technique could be extended or modified to evaluate the timing requirements of other geometries for other future multistatic SAR missions, or other interferometric satellite missions.

Surface Deformation and Change↗

Three-dimensional imaging of dislocation dynamics during the hydriding phase transformation

Crystallographic imperfections can significantly alter material properties and responses to external stimuli, including solute induced phase transformations and crystal growth and dissolution . Despite recent progress in imaging defects using both electron and x-ray techniques, in situ three-dimensional imaging studies of defect dynamics, necessary to understand and engineer nanoscale processes, remains challenging. Here, we report in situ three-dimensional imaging of defect dynamics during the hydriding phase transformation of individual palladium nanocrystals by Bragg Coherent Diffractive Imaging (BCDI) . During constant pressure experiments, we observed that the phase transformation begins after the nucleation of dislocations in large (300 nm) particles. The 3D dislocation network shows that dislocations are close to the phase boundary. The 3D phase morphology resolved by BCDI suggests that the hydrogen-rich phase is more similar to a spherical cap on the hydrogen-poor phase than the core-shell model commonly assumed. We substantiate this conclusion using 3D phase field modeling and demonstrate how phase morphology affects the critical size for dislocation nucleation. We determine the size dependence of the transformation pressure for large (150-300 nm) palladium nanocrystals using variable pressure experiments. Our results reveal a pathway for solute induced structural phase transformations in nanocrystals and demonstrate BCDI as a novel method for understanding dislocation dynamics in phase transforming systems at the nanoscale.

36 MATERIALS SCIENCE↗

Understanding important features of deep learning models for segmentation of high-resolution transmission electron microscopy images

Cutting edge deep learning techniques allow for image segmentation with great speed and accuracy. However, application to problems in materials science is often difficult since these complex models may have difficultly learning meaningful image features that would enable extension to new datasets. In situ electron microscopy provides a clear platform for utilizing automated image analysis. In this work, we consider the case of studying coarsening dynamics in supported nanoparticles, which is important for understanding, for example, the degradation of industrial catalysts. By systematically studying dataset preparation, neural network architecture, and accuracy evaluation, we describe important considerations in applying deep learning to physical applications, where generalizable and convincing models are required. With a focus on unique challenges that arise in high-resolution images, we propose methods for optimizing performance of image segmentation using convolutional neural networks, critically examining the application of complex deep learning models in favor of motivating intentional process design.

36 MATERIALS SCIENCE↗

Modeling electric charge distribution on insulator under electron bombardment: Case of rectangular surface implantation

Despite progress in the study of dielectric properties and the formation of secondary electrons images and especially in the understanding of their mirror curve shape, since the first models for mirror equation were developed, an exact quantitative prediction of the mirror curve for most materials has remained an unsolved problem. In this paper, recent development in the characterization of charge trapping ability of insulators using the scanning electron microscope mirror method (SEMMM) is reviewed. All this work has resulted in unprecedented insights into the early stage of dielectric study and it is also relevant for a deeper understanding of this anomalous effect (mirror effect) as well as for discussion of the factors affecting it. So the dependency of elliptic mirror and the anisotropic effect in the trapping phenomena of charge is highlighted.

36 MATERIALS SCIENCE↗

Imaging Science Requirements for a Uranus Flagship Mission

Introduction: Our presentation will summarize the requirements for UV/Visible/Near-IR remote-sensing imaging science instruments (including mapping spectrometers) envisioned for the Uranus Orbiter and Probe (UOP) mission recommended by the recent planetary decadal survey. The Uranus system offers many targets for imaging investigations. Imaging science investigations are crucial to answering fundamental questions about various physical processes that shape the Uranian system and drive its evolution. Each science objective addressed through imaging has requirements for observation and illumination geometries as well as coverage and resolution in the spatial, spectral and temporal dimensions. By combining the requirements for the diverse science targets in the Uranian system, we present a set of overarching imaging science requirements for UOP. Atmospheric Science: The study of Uranus’ atmosphere is crucial in understanding the planet's energy balance and interior heat flux. Imaging observations map how the atmosphere scatters incident solar radiation. Imaging is key to characterizing planetary-scale energy/material transport though global atmospheric dynamics and local meteorology. Hyperspectral mapping combined with radiative transfer analysis reveals the vertical distribution of clouds and hazes. Chronicling temporal variabilities of atmospheric features is key to understanding the various processes that operate within the dynamic Uranian atmosphere. A comprehensive understanding of Uranus' atmosphere is essential in deciphering the planet's origins and evolution as well as providing insight into the broader field of planetary and exoplanetary science. Magnetospheric Interactions: Imaging science is critical to understand the elusive Uranian aurorae. Mapping the aurorae and their temporal dynamics will reveal the interaction of Uranus’ complex magnetosphere with the solar wind. The apparent decades-long cooling of Uranus’ upper atmosphere is thought to be due to changes in energy input from the overlying magnetosphere, and so mapping and quantifying the auroral evidence for this energy flux is particularly relevant for upper atmospheric science In addition, Uranus’ large moons may generate auroral footprints, which can be used to constrain the planet’s unusual magnetic field structure. Satellite Interiors: Imaging science can address the potential habitability of the larger moons of Uranus by measuring their shapes and rotational states (including librations), which combined with gravity data are crucial to understanding their internal density structure. Satellite Origins: Origin markers such as organics and volatiles may be preserved on the satellite surfaces, which may be sensed by UV/IR mapping. Imaging combined with the moons’ densities may reveal whether the moons formed in Uranus’ circumplanetary disk, rings, or from ejecta of a giant impact on Uranus. Satellite Geology: Imaging investigations, including stereo imaging to obtain topography, will enable constraining each satellite’s geologic history by investigating the distributions and morphologies of impact craters, tectonic and potential cryovolcanic features, and regolith and mass wasting deposits. These records will help unravel the past complex history of orbital resonances that occurred between Uranian satellites, which may have driven geologic activity. Analyses of these features will also point to resurfacing styles and modification processes important for understanding each moon’s thermal evolution, and any present-day geological activity, including potential subsurface deep oceans or possible current activity. Additionally, hyperspectral imaging will enable mapping the surface composition and identifying the potential presence of material that may point to a subsurface ocean, such as ammonia-bearing species. Rings and Small Moons: Imaging observations elucidate the physical processes that contribute to the complex ring-moon system’s inferred unstable state. Imaging surveys will seek smaller moons and other debris that could provide evidence of past collisions, while precise astrometric data of moons will determine the current dynamical state of the system. Many of Uranus' rings are exceptionally narrow, and images of the rings covering a broad range of longitudes, and high-resolution images of features within the rings will reveal how these rings are confined and maintained, as well as illustrating the rings' internal structure and dynamics. Images of the rings and moons obtained at a variety of wavelengths and lighting conditions are also needed to quantify the composition and the size distribution of the small satellites and ring particles.

K M Sayanagi↗

Rapid and flexible segmentation of electron microscopy data using few-shot machine learning

Abstract Automatic segmentation of key microstructural features in atomic-scale electron microscope images is critical to improved understanding of structure–property relationships in many important materials and chemical systems. However, the present paradigm involves time-intensive manual analysis that is inherently biased, error-prone, and unable to accommodate the large volumes of data produced by modern instrumentation. While more automated approaches have been proposed, many are not robust to a high variety of data, and do not generalize well to diverse microstructural features and material systems. Here, we present a flexible, semi-supervised few-shot machine learning approach for segmentation of scanning transmission electron microscopy images of three oxide material systems: (1) epitaxial heterostructures of SrTiO 3 /Ge, (2) La 0.8 Sr 0.2 FeO 3 thin films, and (3) MoO 3 nanoparticles. We demonstrate that the few-shot learning method is more robust against noise, more reconfigurable, and requires less data than conventional image analysis methods. This approach can enable rapid image classification and microstructural feature mapping needed for emerging high-throughput characterization and autonomous microscope platforms.

36 MATERIALS SCIENCE↗

IR-MALDESI Mass Spectrometry Imaging at 50 Micron Spatial Resolution

High spatial resolution in mass spectrometry imaging (MSI) is crucial to understanding the biology dictated by molecular distributions in complex tissue systems. Here, we present MSI using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) at 50 μm resolution. An adjustable iris, beam expander, and an aspherical focusing lens were used to reduce tissue ablation diameters for MSI at high resolution. The laser beam caustic was modeled using laser ablation paper to calculate relevant laser beam characteristics. The minimum laser spot diameter on the tissue was determined using tissue staining and microscopy. Finally, the newly constructed optical system was used to image hen ovarian tissue with and without oversampling, detailing tissue features at 50 μm resolution. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Understanding Portability of Automotive Workload: A Case Study with the Points-to-Image Kernel in SYCL on Heterogeneous Computing Platforms

SYCL is a promising programming model for heterogenous computing across vendors’ devices. In this paper, we study whether SYCL can be applied to an automotive workload and its portability on heterogeneous computing platforms. We explain the automotive benchmark, describe our implementations and optimizations of the benchmark, and evaluate the performance of the benchmarks using SYCL and other programming models on heterogeneous computing devices. The study also allows us to have a better understanding of portability of the benchmark across these platforms.

Jin, Zheming↗