Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “homes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Modeling Occupant Core Temperatures Across the Boston Building Stock to Advance Public Health

In recent history, extreme heat has been the cause of most deaths from a natural disaster. Exposure to extreme heat can aggravate preexisting conditions, increase hospitalization, and even cause death. Thus, modeling the thermal resilience of households across the United States will allow for a quantitative assessment of the health and safety risks posed by extreme heat. For the first time, we simulate occupant comfort in representative households across Boston by combining the granular results of the ResStock(TM) model with a two-node heat strain model. This model calculates occupants' core body temperature in each simulated household over a year. We compare the simulated core temperatures to two public health metrics: hyperthermia and heat stroke. Our results show for households in Boston that do not have or use aid conditioning, thousands potentially experience many dangerous heat events each summer and these events can last for more than a day at a time. These heat events peak during the late afternoon and evening, just as residents are coming home, cooking meals, and trying to go to sleep. We have found that multi-family buildings, renters, and low-income homes in more airtight and insulated homes are the most at risk for these events. These results demonstrate the scale and urgency of exposure to extreme heat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A bibliography of wildlife movements and tracking systems

A bibliography is presented consisting of 1,005 references concerned with animal orientation, homing, navigation, migration, and home range movements, and the various methods of tracking and monitoring such behavior through biotelemetry, radar, and various banding and tagging techniques. A majority of the publications appeared between 1950 and 1970, although the most intensive search was made of the 1965-1970 period. A small number of older articles and books were included because they appeared to have some special or unusual value. The references have been organized in two ways. First, they are grouped in primary categories on the basis of the behavior involved such as orientation, homing, etc., and the methods of tracking. Second, within each of the resulting major areas, the items are arranged in terms of the species of animal. This sequence is maintained throughout the bibliography and in many cases represents a rank order according to the number of publications found.

Werber, M.↗

Patterns of behavior in lodgings exposed to traffic noise

Threshold values for public services interferent on the attenuation to noise nuisance were defined. Daily life at home was described and collected on the use of residences, the effects of noise on health and sleep, and the incidence of running away from home. A correlation was made with the equipment and noise insulation of homes. It is shown that there are behavior patterns in the modification of considerable manner in the way of life for people who live in apartments and in individual houses, above 66 dB during daytime.

Lambert, J.↗

Heart Rate Monitors

Under a NASA grant, Dr. Robert M. Davis and Dr. William M. Portnoy came up with a new type of electrocardiographic electrode that would enable long term use on astronauts. Their invention was an insulated capacitive electrode constructed of a thin dielectric film. NASA subsequently licensed the electrode technology to Richard Charnitski, inventor of the VersaClimber, who founded Heart Rate, Inc., to further develop and manufacture personal heart monitors and to produce exercise machines using the technology for the physical fitness, medical and home markets. Same technology is on both the Home and Institutional Model VersaClimbers. On the Home Model an infrared heart beat transmitter is worn under exercise clothing. Transmitted heart rate is used to control the work intensity on the VersaClimber using the heart rate as the speedometer of the exercise. This offers advantages to a full range of users from the cardiac rehab patient to the high level physical conditioning of elite athletes. The company manufactures and markets five models of the 1*2*3 HEART RATE monitors that are used wherever people exercise to accurately monitor their heart rate. Company is developing a talking heart rate monitor that works with portable headset radios. A version of the heart beat transmitter will be available to the manufacturers of other aerobic exercise machines.

Source record↗

Effects of afternoon "siesta" naps on sleep, alertness, performance, and circadian rhythms in the elderly

STUDY OBJECTIVES: To determine the effects of a 90-minute afternoon nap regimen on nocturnal sleep, circadian rhythms, and evening alertness and performance levels in the healthy elderly. DESIGN AND SETTING: Nine healthy elderly subjects (4m, 5f, age range 74y-87y) each experienced both nap and no-nap conditions in two studies each lasting 17 days (14 at home, 3 in the laboratory). In the nap condition a 90-minute nap was enforced between 13:30 and 15:00 every day, in the no-nap condition daytime napping was prohibited, and activity encouraged in the 13:30-15:00 interval. The order of the two conditions was counterbalanced. PARTICIPANTS: N/A INTERVENTIONS: N/A MEASUREMENTS: Diary measures, pencil and paper alertness tests, and wrist actigraphy were used at home. In the 72 hour laboratory studies, these measures were augmented by polysomnographic sleep recording, continuous rectal temperature measurement, a daily evening single trial of a Multiple Sleep Latency Test (MSLT), and computerized tests of mood, activation and performance efficiency. RESULTS: By the second week in the "at home" study, an average of 58 minutes of sleep was reported per siesta nap; in the laboratory, polysomnography confirmed an average of 57 minutes of sleep per nap. When nap and no-nap conditions were compared, mixed effects on nocturnal sleep were observed. Diary measures indicated no significant difference in nocturnal sleep duration, but a significant increase (of 38 mins.) in 24-hour Total Sleep Time (TST) when nocturnal sleeps and naps were added together (p<0.025). The laboratory study revealed a decrease of 2.4% in nocturnal sleep efficiency in the nap condition (p<0.025), a reduction of nocturnal Total Sleep Time (TST) by 48 mins. in the nap condition (p<0.001) which resulted primarily from significantly earlier waketimes (p<0.005), but no reliable effects on Wake After Sleep Onset (WASO), delta sleep measures, or percent stages 1 & 2. Unlike the diary study, the laboratory study yielded no overall increase in 24-hour TST consequent upon the siesta nap regimen. The only measure of evening alertness or performance to show an improvement was sleep latency in a single-trial evening MSLT (nap: 15.6 mins., no nap: 11.5 mins., p<0.005). No significant change in circadian rhythm parameters was observed. CONCLUSIONS: Healthy seniors were able to adopt a napping regimen involving a 90-minute siesta nap each day between 13:30 and 15:00, achieving about one hour of actual sleep per nap. There were some negative consequences for nocturnal sleep in terms of reduced sleep efficiency and earlier waketimes, but also some positive consequences for objective evening performance and (in the diary study) 24-hour sleep totals. Subjective alertness measures and performance measures showed no reliable effects and circadian phase parameters appeared unchanged.

Non-NASA Center↗

Keeping a Beat on the Heart

Feel the relief of a patient suffering from heart arrhythmia, who is able to return home while having her heart monitored by health professionals 24 hours a day, without the fear that she will miss an important indicator and suffer a fatal heart attack - using technology originally developed to conduct experiments on the Space Shuttle. Approximately 400,000 Americans die every year from sudden heart attacks . Medical research revealed that patterns of electrical activity in the heart can act as predictors of these lethal cardiac events known as arrhythmias. Fortunately, certain arrhythmias such as ventricular fibrillation (loss of regular heartbeat and subsequent loss of function) and ventricular tachycardia (rapid heartbeats), can be detected and appropriately treated. Today, patients at moderate risk of arrhythmias can benefit from technology that would permit long- term continuous monitoring of electrical cardiac rhythms outside the hospital environment in the comfort of their own homes. Medical telemetry systems, also known as telemedicine, are evolving rapidly as wireless communication technology advances, evidenced by the commercial products and research prototypes for remote health monitoring that have appeared in recent years. Wireless systems allow patients to move freely in their home and work environment while being monitored remotely by health care professionals.

Liszka, Kathy J.↗

Shock Prevention

The electrician pictured is installing a General Electric Ground Fault Interrupter (GFI), a device which provides protection against electrical shock in the home or in industrial facilities. Shocks due to defective wiring in home appliances or other electrical equipment can cause severe burns, even death. As a result, the National Electrical Code now requires GFIs in all new homes constructed. This particular type of GFI employs a sensing element which derives from technology acquired in space projects by SCI Systems, Inc., Huntsville, Alabama, producer of sensors for GE and other manufacturers of GFI equipment. The sensor is based on the company's experience in developing miniaturized circuitry for space telemetry and other spacecraft electrical systems; this experience enabled SCI to package interruptor circuitry in the extremely limited space available and to produce sensory devices at practicable cost. The tiny sensor measures the strength of the electrical current and detects current differentials that indicate a fault in the functioning of an electrical system. The sensing element then triggers a signal to a disconnect mechanism in the GFI, which cuts off the current in the faulty circuit.

Source record↗

Field Exploration and Life Detection Sampling Through Planetary Analogue Sampling (FELDSPAR).

Exploration missions to Mars rely on rovers to perform analyses over small sampling areas; however, landing sites for these missions are selected based on large-scale, low-resolution remote data. The use of Earth analogue environments to estimate the multi-scale spatial distributions of key signatures of habitability can help ensure mission science goals are met. A main goal of FELDSPAR is to conduct field operations analogous to Mars sample return in its science, operations, and technology from landing site selection, to in-field sampling location selection, remote or stand-off analysis, in situ analysis, and home laboratory analysis. Lava fields and volcanic regions are relevant analogues to Martian landscapes due to desiccation, low nutrient availability, and temperature extremes. Operationally, many Icelandic lava fields are remote enough to require that field expeditions address several sampling constraints that are experienced in robotic exploration, including in situ and sample return missions. The Fimmvruhls lava field was formed by a basaltic effusive eruption associated with the 2010 Eyjafjallajkull eruption. Mlifellssandur is a recently deglaciated plain to the north of the Myrdalsjkull glacier. Holuhraun was formed by a 2014 fissure eruptions just north of the large Vatnajkull glacier. Dyngjusandur is an alluvial plain apparently kept barren by repeated mechanical weathering. Informed by our 2013 expedition, we collected samples in nested triangular grids every decade from the 10 cm scale to the 1 km scale (as permitted by the size of the site). Satellite imagery is available for older sites, and for Mlifellssandur, Holuhraun, and Dyngjusandur we obtained overhead imagery at 1 m to 200 m elevation. PanCam-style photographs were taken in the field by sampling personnel. In-field reflectance spectroscopy was also obtained with an ASD spectrometer in Dyngjusandur. All sites chosen were 'homogeneous' in apparent color, morphology, moisture, grain size, and reflectance spectra at all scales greater than 10 cm. Field lab assays were conducted to monitor microbial habitation, including ATP quantification, qPCR for fungal, bacterial, and archaeal DNA, and direct cell imaging using fluorescence microscopy. Home laboratory analyses include Raman spectroscopy and community sequencing. ATP appeared to be significantly more sensitive to small changes in sampling location than qPCR or fluorescence microscopy. Bacterial and archaeal DNA content were more consistent at the smaller scales, but similarly variable across more distant sites. Conversely, cell counts and fungal DNA content have significant local variation but appear relatively homogeneous over scales of 1 km. ATP, bacterial DNA, and archaeal DNA content were relatively well correlated at many spatial scales. While we have observed spatial variation at various scales and are beginning to observe how that variation fluctuates over time as biodiversity recovers after an eruption, we do not yet fully understand what parameters lead to the observed spatial variation. Home laboratory analyses will help us further understand the elemental and structural composition of the basaltic matrices, but further field analyses are vital for the understanding how temperature, moisture, incident radiation, and so forth influence the habitability of a microclimate.

Field↗

Schedule Factors Associated with the Use of Controlled Rest in a Long-Haul Airline

Controlled Rest (CR) refers to a short, voluntary nap opportunity taken by pilots on the flight deck as a countermeasure to unanticipated sleepiness in flight. This study explores the profile of CR use in a long-haul commercial airline. Forty-four pilots wore actiwatches and filled in an application-based sleep/work diary for approximately 2 weeks. After merging sleep diary, actigraphy, and schedule data, complete records were analyzed from 240 flights. Sleep was estimated during CR intervals using the Philips Actiware 6.0.9 (Bend, OR) software with wake threshold set to medium. Timing of sleep periods and flight schedules were analyzed relative to home-base time. A mixed-effects binary logistics regression was used to analyze the impact of schedule factors on CR. Preliminary analyses revealed that CR was taken on 45% (n=107) of flights. Average sleep duration within these rest periods was estimated as 24.8 ± 16.1 minutes. CR was more frequent on return flights (arriving at home-base; 58%, n=69) vs. outbound flights (departing from home-base, 31%, n=38; p<0.001). There was no difference for direction of travel (eastbound: 49%, n= 56; westbound: 40%, n= 44; northbound/southbound: 50%, n=7; p=0.272). CR was more frequent on 2-pilot flights (62%, n=81) compared to augmented crew flights (24%, n=26; p<0.001). Of note, 21% (n=23) of augmented flights contained both CR and Bunk Rest. CR was more frequent on flights <10h duration (<10h: 59%, n=78; >10h: 27%, n=29; p<0.001). Flights departing between 12:00h-19:59h (25%, n=23; p<0.026) had the lowest frequency of CR. Data from this airline show that CR is most commonly used as a countermeasure to sleepiness on return, unaugmented, <10h duration, and nighttime flights. The direction of travel did not influence the use of CR. Future studies are required to determine generalizability of these results to other airlines.

Hilditch, Cassie↗

The Influence of Self-Reported Distractions on the Psychomotor Vigilance Task (PVT) in Laboratory and Field Environments

Introduction: The Psychomotor Vigilance Task (PVT) is a measure of vigilant attention that is commonly used in laboratory environments to assess the neurobehavioral impact of sleep loss and circadian misalignment. The PVT has been increasing in popularity for use in field environments; however, the potential for distraction is higher in the field compared to the lab. It is unclear how distractions experienced by individuals taking the PVT in the real world may influence reaction time metrics. We investigated the influence of self-reported distraction on PVT outcomes across laboratory and field environments. Methods: We examined PVT data from five studies including short (n=36 participants, 3799 PVTs) and long-haul (n=75 participants, 3283 PVTs) airline personnel, control center personnel (n=5 participants, 96 PVTs), and healthy individuals who participated in a study involving at-home and laboratory assessments (n=12 participants, 486 and 310 PVTs). Individuals in all of the studies were asked to complete the five-minute NASA PVT at least three times daily. Participants were asked to indicate the number of distractions they experienced immediately after each PVT. Mean PVT reaction time (RT) and number of distractions were computed for each study and overall. Results: Participants reported more distractions in field environments compared to the lab (short-haul=1.29 +/- 1.48, long-haul=0.66 +/- 1.07, control-center=1.20 +/- 1.37, at-home=0.86 +/- 1.36, laboratory=0.46 +/- 1.07) Across all studies, we found that PVT RT slowed as self-reported distractions increased (all studies combined: 0 distractions=PVT RT 274.4ms; 1=284.6ms; 2=302.9ms; 3=321.2ms; >4=409.3ms). These findings were similar for healthy participants completing PVTs at home (0 distractions=287.1ms; 1=309.9ms; 2=328.3ms; 3=369.8ms; >4=385.1ms) but were less consistent during in-lab assessments (0 distractions=278.7ms; 1=316.2ms; 2=396.2ms; 3=370.4ms; >4=354.4ms). These findings were similar for other PVT outcomes. Conclusion: Participants reported more distractions in field environments compared to the laboratory. Our findings suggest that the number of distractions that individuals report experiencing while taking a PVT increases the reaction time registered by the device. Researchers should collect information about distractions during the PVT and should be aware that distractions may influence the recorded PVT reaction time.

behavior↗

Expanding the Field of Climate Finance

Over the past twenty-one years, the Financial Innovations Roundtable (FIR), located at the Carsey School of Public Policy at the University of New Hampshire, has worked to address problems related to access to capital for low- and moderate-income consumers and communities. Since 2014, the event has been co-hosted by the Federal Reserve Board. The FIR works with a range of financial institutions, government agencies, foundations, and trade associations to access their expertise for problem-solving discussions. The 2020 FIR focused on the expanding field of climate finance and was co-hosted by the Federal Reserve Bank of San Francisco and The Climate Safe Lending Network. The event was originally slated to be in-person in San Francisco in May 2020 but was postponed due to the pandemic and shifted to an online event hosted November 16‒17, 2020. A significant amount has happened in 2020 on climate finance, racial justice, the economy, and COVID-19. The shocks and stresses of climate change are creating risks in low- and moderate-income communities as well as in the financial sector broadly. The 2020 FIR offered an opportunity to discuss the challenges and opportunities banks and Community Development Financial Institutions (CDFIs) face as they address these risks and how these institutions can help increase individual, institutional, and community-wide resilience. The program explored new and modified products that address climate risk in communities and how those products can be scaled. Conversations focused around: • The progress that has been made in the climate finance field and the challenges that lie ahead for financial institutions’ climate impact and climate-related risk. • Promising opportunities to decarbonize investments and finance low-carbon technology and infrastructure. • How lenders, insurers, housing organizations, and the public sector can work together to reduce housing instability due to climate-related factors and increase the climate-resilience of homes and neighborhoods. • Solutions to help communities address a wide range of related issues, including home weatherization and disaster preparation, home insurance loss, and climate gentrification and displacement. • Discussing lessons learned from other sectors such as renewable energy in order to design both people-based and place-based finance solutions that promote racial and economic inclusion. 1 • The need for all financial institutions to acknowledge that climate risks and racial inequity are systemic risks affecting their bottom line. • The role that bank regulators can play in promoting collaboration across the financial sector and in leading by example with regard to climate finance. • Mapping out concrete action-item initiatives including policy and industry pathways to climate safe lending as well as building a financing platform to provide clean energy to low-income communities. • More broadly, in order to systemically address climate risks, we will need to work together as a range of stakeholders across sectors and collaborate on shared goals and projects.

14 SOLAR ENERGY↗

Designing for Supply and Return Air System Interaction in Residential Buildings

Standard practice for HVAC return design has evolved from running a dedicated return to each room with a supply, to systems with returns in more centrally located areas of the home with jump ducts, transfer grilles, or simply door undercuts used as return air pathways from isolated rooms . In these latter systems, hallways and stairwells act as large open ducts for conveying air back to a single (or sometimes multiple) central return. When partition doors to an isolated room are closed, the return airflow resistance goes up, significantly impacting airflow balance if an adequate relief pathway is not installed. Airflow imbalances can lead to comfort and building durability issues and increased envelope leakage. To combat this, some jurisdictions have requirements for return air pathways. The supply system topology – or layout - impacts the airflow balance stability in response to adjustments of return pathway resistances. Branching supply topologies typically have reduced static pressure after each split. The static pressure at the final split will be lower than the primary supply plenum. Because of this, if there is a restriction in a room’s return path, supply airflow will tend to redistribute to adjacent ducts at the end of the branch. A properly designed trunk and branch supply system can effectively equalize static pressure by reducing the cross sectional area after each takeoff . Maintaining static pressure within the trunk will reduce the system’s sensitivity to changes in return paths. However, in practice, it is difficult to design and time consuming to install a complex supply plenum. Velocity effects and poor takeoff placement also impact airflow balance. This fact sheet considers return systems in three main categories: distributed, with a return duct to each room; multiple central, with one return grille on each floor of a home; and single central, with a single return grille located near the air handling unit. Three supply categories are also considered: radial splitter box, trunk and branch, and home-run with all ducts connecting directly to a central manifold. A complete description of the modeling work and results can be found in the companion technical report.

buildings↗

NCSU Industrial Assessment Center

Renewable energy technologies are becoming more attractive and gaining more attention as the world becomes increasingly aware of the negative impacts of global warming and greenhouse gas (GHG) emissions. Two such emerging technologies are geothermal heat pumps (GHP) and solar thermal heating which can be used for heating and cooling of buildings. GHP systems are a well-studied technology that have been proven to be more efficient than traditional air-source heat pumps for space conditioning of buildings. Solar thermal heating has become more common as a way to heat domestic hot water (DHW) in homes, but the two technologies are not often combined. This study presents the findings of combining an open-loop GHP with 100 ft2 of flat plate solar thermal panels and a 5,655-gallon sensible water storage tank for space heating and DHW heating needs of a residential home in Bozeman, MT, USA. The goal of this system was to use energy from the solar panels and storage tank first to decrease pumping energy from the GHP well. The open loop system was designed to be a backup system to the solar thermal panels and sensible storage tank. An actual home was modeled to determine potential energy and cost savings of such a system compared to a traditional propane boiler. Then, a case study was performed on the installed system from January to June 2021. Results obtained from April 2nd to June 5th, 2021 indicated that the combination system supplied all necessary heat, and that heat was supplied from the thermal storage tank 55% of the time. This represents a savings of 330 kWh of energy and $36 compared to operating just the open loop geothermal system. From April 2nd to June 5th the combination system consumed a total of 2,510 kWh of energy and cost $274 to operate. Based on data obtained, there is significant potential for energy savings compared to a propane boiler, however only small potential for cost savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Mitigating Moisture with High-R Walls

Energy-efficient building enclosures are key to decreasing energy load demand and enabling advanced space-conditioning systems for high-performance homes. One efficient enclosure design solution is high-R walls, which feature increased insulation levels as an effective solution for reducing air leakage and permeance of material layers. To increase builder confidence and encourage greater market adoption of high-R walls, Home Innovation Research Labs sought to demonstrate the long-term moisture performance of several high-R wall configurations in cold climate zones. The team monitored 22 newly constructed, occupied homes located throughout climate zones 4–7, where a substantial vapor drive to the exterior is present during the winter.

buildings↗

Modeling Assessment of Residential Air-to-Water Heat Pumps Coupled with Cooling Thermal Storage

This study explored the performance and operating cost viability of air-to-water heat pumps (AWHPs) coupled with thermal energy storage (TES) in efficient new residential construction. AWHPs are an emerging technology in this country, but offer promise in terms of high efficiency, fully contained and factory charged outdoor refrigeration system, and hydronic delivery capabilities, which facilitates zoning, ducts in conditioned space, and TES integration for summer load-shifting. Although this AWHP+TES strategy is not yet mainstream, the authors feel that in ten years as decarbonization efforts proceed and TOU rates become more common, strategies such as this will be more accessible. Validated EnergyPlus simulation models were developed based on detailed monitoring data collected over several years at Pacific Gas and Electric's CVRH laboratory test homes located in Stockton, California. One of the CVRH test homes (1,962 ft 2 two-story) had been testing various AWHP systems and configurations over the past six years. The validated model was then updated with high efficiency IECC ZERH envelope and component requirements for climate zones 1-5, including ducts in conditioned space thermal distribution. Simulations were completed for the 1,962 ft 2 home in each climate zone for a minimum efficiency ASHP, an AWHP coupled with a fan coil, and an AWHP coupled with TES sized to eliminate summer on-peak compressor operation. To maintain consistency in reporting energy use estimates, all cases were run with a similar indoor thermostat control strategy to pre-cool the house below the nominal 76 degrees Fahrenheit set point prior to the on-peak period and float slightly above the set point during the peak period. The AWHP+TES configuration was controlled to alternately condition the indoor space or to charge the TES tanks prior to the beginning of the on-peak. Three composite TOU rates were developed based on existing TOU rates across the U.S. to provide differing economic scenarios to evaluate customer bill impacts throughout the summer. Two of the TOU rates had short three-hour peak periods, while the third rate had a longer seven-hour duration peak period. AWHP modeling projections were based on the observed field performance of the Chiltrix CX34 variable speed unit. Other products on the market or entering the market in the near term would likely perform differently.

25 ENERGY STORAGE↗

Case Studies of Residential Façade Upgrades in Four Climate Zones

This paper reports on a project that explored the viability of insulation and window upgrades during siding retrofits in four case studies across the United States. Thousands of homes are re-sided every year, but only a fraction of consumers add insulation and upgrade the windows at the same time, even though a siding replacement is the ideal time to update the thermal performance of building enclosures. To better understand why more siding retrofits do not include insulation and window upgrades, research staff from several organizations collaborated with the U.S. Department of Energy on a multi-faceted research project that included a cost analysis, workforce analysis, market assessment, and contractor assessment. This paper will review four in-field case studies conducted with contractors actively engaged in home re-siding projects that agreed to add rigid insulation and window upgrades as part of their projects. Findings from the case studies will be presented including contractor perspectives, cost, and technical approaches on projects, located in multiple climate zones including Bellingham WA, Jackson MS, Kalamazoo MI, and Phoenix AZ. All projects involved adding continuous rigid insulation on the exterior walls and installation of new cladding. Cladding types varied from wood and metal to fiber cement, vinyl, and traditional stucco. All homes also received a window upgrade, although upgrades varied depending on the original condition of the windows and climate; upgrades included triple-pane windows, low-e storm windows, and exterior shading. Key findings including technical approaches, opportunities, barriers, and project cost will be presented.

re-siding, insulation, rigid insulation, exterior ↗

Alaska's First Thermalize Campaign: An Effort to Reduce Fuel Reliance in Juneau, AK

In 2018, the Bureau and City of Juneau set the goal of reaching 80% renewable energy in the sectors of transportation and space heating by 2045. This effort will minimize their reliance on fossil fuels, reduce their carbon footprint and increase their resilience in the event of a natural disaster as fuel oil reaches Juneau by boat and such shipments may be disrupted in a disaster. The community's resilience in the face of a disaster and lower carbon footprint goes hand-in-hand with public safety and health. The Cold Climate Housing and Research Center (CCHRC) partnered with several local and statewide groups, including Alaska Heat Smart and Information Insights, Inc, to lead Alaska's first thermalize campaign. Thermalize Juneau 2021 is an energy campaign working to lower the cost of heating homes in Juneau through beneficial electrification and increased energy efficiency. The goal of the campaign was to offer homeowners a streamlined and more affordable way to install heat pumps and energy efficiency improvements into their homes. Converting household heating from fuel to electricity also helps improve indoor and outdoor air quality and reduces maintenance requirements. The campaign had over 160 participants. As of Fall 2021, it is in its final stages of heat pump installations and energy efficiency improvements. In addition to tracking the energy savings and carbon reduction attributed to the campaign, the social equity was an important aspect. Thermalize Juneau attempted to include all the demographics present in Juneau in the campaign. The presentation will cover the goals and implementation of the campaign, current data on how it is improving community and household resilience, lessons learned, and next steps.

clean energy↗

AI-Driven Smart Community Control for Accelerating PV Adoption and Enhancing Grid Resilience

The U.S. Department of Energy (DOE) has launched a Connected Communities program that supports projects that expand DOE's network of grid-interactive, efficient building communities nationwide. As an early pilot of Connected Communities, the National Renewable Energy Laboratory (NREL) and its partners have developed and demonstrated a community-scale, hierarchical control solution to address the potential grid issues arising from high penetration of solar photovoltaics (PV) as well as to improve grid reliability and resilience in this residential community. A field pilot study has been performed at an affordable housing development called the Basalt Vista Community, which was built for school teachers and other professionals in the local workforce and represents an autonomous energy grid with all-electric, energy-efficient homes. With no natural gas line in the community, this is the first all-electric net-zero community in rural Colorado. In the field pilot study, NREL has validated the performance of the hierarchical control solution, which consists of NREL's foresee home energy management systems (HEMS) and community aggregators, in increasing demand flexibility and self-consuming PV, reducing potential over-voltages, and supporting critical loads during emergency events. In this presentation, we will present the methodology, simulation and field pilot results, and lessons learned from the project.

all-electric community↗