Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “high angular resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

A Seeman–Bohlin geometry for high-resolution nanosecond x-ray diffraction measurements from shocked polycrystalline and amorphous materials [Shock compression measurement in a Seeman-Bohlin camera geometry developed for time-resolved x-ray diffraction studies of shocked polycrystalline and amorphous materials]

Here, we report on a focusing x-ray diffraction geometry capable of high-resolution in situ lattice probing from dynamically loaded polycrystalline and amorphous materials. The Seeman–Bohlin-type camera presented here is ideally suited for time-resolved x-ray diffraction measurements performed on high energy multibeam laser platforms. Diffraction from several lattice planes of ablatively shock-loaded 25 μm thick Cu foils was recorded on a focusing circle of diameter D=100 mm with exceptional angular resolution limited only by the spectral broadening of the x-ray source. Excellent agreement was found between the density measured using x-ray diffraction and that inferred from Doppler velocimetry and the known shock Hugoniot of Cu. In addition, x-ray diffraction signal was captured from an amorphous material under static conditions.

36 MATERIALS SCIENCE↗

Infrared observations of the quintuplet proper members using SOFIA/FORCAST and GEMINI/TReCS

Since their discovery, the Quintuplet proper members (QPMs) have been somewhat mysterious in nature. Originally dubbed the “cocoon stars” due to their cool featureless spectra, high-resolution near-infrared imaging observations have shown that at least two of the objects exhibit “pinwheel” nebulae consistent with binary systems with a carbon-rich Wolf–Rayet star and O/B companion. In this paper, we present 19.7, 25.2, 31.5, and 37.1 μm observations of the QPMs (with an angular resolution of 3.2″–3.8″) taken with the Faint Object Infrared Camera for the SOFIA Telescope (FORCAST) in conjunction with high-resolution (∼0.1″–0.2″) images at 8.8 and 11.7 μm from the Thermal-Region Camera Spectrograph (TReCS). DUSTY models of the thermal dust emission of two of the four detected QPMs, Q2 and Q3, are fitted by radial density profiles that are consistent with constant mass-loss rates (ρ{sub d}∝r{sup −2}). For the two remaining sources, Q1 and Q9, extended structures (∼1″) are detected around these objects in high-resolution imaging data. Based on the fitted dust masses, Q9 has an unusually large dust reservoir (M{sub d}=1.3{sub −0.4}{sup +0.8}×10{sup −3}M{sub ⊙}) compared to typical dusty Wolf–Rayet stars, which suggests that it may have recently undergone an episode of enhanced mass loss.

79 ASTRONOMY AND ASTROPHYSICS↗

The ({sup 18}O, {sup 16}O) reaction as a probe for nuclear spectroscopy

The response of nuclei to the ({sup 18}O, {sup 16}O) two-neutron transfer reaction at 84 MeV incident energy has been systematically studied at the Catania INFN-LNS laboratory. The experiments were performed using several solid targets from light ({sup 9}Be, {sup 11}B, {sup 12,13}C, {sup 16}O, {sup 28}Si) to heavy ones ({sup 58,64}Ni, {sup 120}Sn, {sup 208}Pb). The {sup 16}O ejectiles were detected at forward angles by the MAGNEX magnetic spectrometer. Exploiting the large momentum acceptance (−10%, +14%) and solid angle (50 msr) of the spectrometer, energy spectra were obtained with a relevant yield up to about 20 MeV excitation energy. The application of the powerful trajectory reconstruction technique did allow to get energy spectra with energy resolution of about 150 keV and angular distributions with angular resolution better than 0.3°. A common feature observed with light nuclei is the appearance of unknown resonant structures at high excitation energy. The strong population of these latter together with the measured width can reveal the excitation of a collective mode connected with the transfer of a pair.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE DECREASE OF SPECIFIC ANGULAR MOMENTUM AND THE HOT TOROID FORMATION: THE MASSIVE CLUMP G10.6-0.4

This is the first paper of our series of high-resolution (1'') studies of the massive star-forming region G10.6-0.4. We present the emission line observations of the hot core type tracers (O{sup 13}CS, OCS, SO{sub 2}) with {approx}0.''5 resolution. By comparing the results to the high-resolution NH{sub 3} absorption line observation, we confirm for the first time the rotationally flattened hot toroid in the central <0.1 pc region, which has a rotational axis perpendicular to its geometrical major axis. In addition, we present the observations of NH{sub 3}, {sup 13}CS, and CH{sub 3}CN with {approx}1'' resolution, and follow the dynamics of the molecular accretion flow from the 0.3 pc radius to the inner 0.03 pc radius. With reference to the rotational axis of the hot toroid, we measure the rotational velocity from the molecular emission in the region. The results are consistent with an envelope with a rapid decrease of the specific angular momentum from the outer to the inner region. These new results improve the current understanding of the molecular accretion flow in an ultracompact H II region created by the embedded O-type cluster.

79 ASTRONOMY AND ASTROPHYSICS↗

DISTRIBUTION OF ACCRETING GAS AND ANGULAR MOMENTUM ONTO CIRCUMPLANETARY DISKS

We investigate gas accretion flow onto a circumplanetary disk from a protoplanetary disk in detail by using high-resolution three-dimensional nested-grid hydrodynamic simulations, in order to provide a basis of formation processes of satellites around giant planets. Based on detailed analyses of gas accretion flow, we find that most of gas accretion onto circumplanetary disks occurs nearly vertically toward the disk surface from high altitude, which generates a shock surface at several scale heights of the circumplanetary disk. The gas that has passed through the shock surface moves inward because its specific angular momentum is smaller than that of the local Keplerian rotation, while gas near the midplane in the protoplanetary disk cannot accrete to the circumplanetary disk. Gas near the midplane within the planet's Hill sphere spirals outward and escapes from the Hill sphere through the two Lagrangian points L{sub 1} and L{sub 2}. We also analyze fluxes of accreting mass and angular momentum in detail and find that the distributions of the fluxes onto the disk surface are well described by power-law functions and that a large fraction of gas accretion occurs at the outer region of the disk, i.e., at about 0.1 times the Hill radius. The nature of power-law functions indicates that, other than the outer edge, there is no specific radius where gas accretion is concentrated. These source functions of mass and angular momentum in the circumplanetary disk would provide us with useful constraints on the structure and evolution of the circumplanetary disk, which is important for satellite formation.

79 ASTRONOMY AND ASTROPHYSICS↗

CARMA CO(J = 2 - 1) OBSERVATIONS OF THE CIRCUMSTELLAR ENVELOPE OF BETELGEUSE

We report radio interferometric observations of the {sup 12}C{sup 16}O 1.3 mm J = 2 - 1 emission line in the circumstellar envelope of the M supergiant {alpha} Ori and have detected and separated both the S1 and S2 flow components for the first time. Observations were made with the Combined Array for Research in Millimeter-wave Astronomy (CARMA) interferometer in the C, D, and E antenna configurations. We obtain good u - v coverage (5-280 k{lambda}) by combining data from all three configurations allowing us to trace spatial scales as small as 0.''9 over a 32'' field of view. The high spectral and spatial resolution C configuration line profile shows that the inner S1 flow has slightly asymmetric outflow velocities ranging from -9.0 km s{sup -1} to +10.6 km s{sup -1} with respect to the stellar rest frame. We find little evidence for the outer S2 flow in this configuration because the majority of this emission has been spatially filtered (resolved out) by the array. We also report a SOFIA-GREAT CO(J = 12 - 11) emission line profile, which we associate with this inner higher excitation S1 flow. The outer S2 flow appears in the D and E configuration maps and its outflow velocity is found to be in good agreement with high-resolution optical spectroscopy of K I obtained at the McDonald Observatory. We image both S1 and S2 in the multi-configuration maps and see a gradual change in the angular size of the emission in the high absolute velocity maps. We assign an outer radius of 4'' to S1 and propose that S2 extends beyond CARMA's field of view (32'' at 1.3 mm) out to a radius of 17'', which is larger than recent single-dish observations have indicated. When azimuthally averaged, the intensity falloff for both flows is found to be proportional to R{sup -1}, where R is the projected radius, indicating optically thin winds with {rho}{proportional_to}R{sup -2}.

79 ASTRONOMY AND ASTROPHYSICS↗

SHARAQ Spectrometer - Current status and future experimental plans

The high-resolution SHARAQ spectrometer and the dedicated high-resolution beamline have been constructed at RI beam factory and commissioned in 2009. Lateral and angular dispersion matching conditions were achieved simultaneously for a primary beam with a momentum spread of 0.1% and an emittance of 3pi mmcentre dotmrad (sigma). An overview of the spectrometer and the beam-line, preliminary results from the commissioning runs, and future experimental plan with the system are described.

43 PARTICLE ACCELERATORS↗

Numerical simulations of colliding jets in an external wind: application to 3C 75

ABSTRACT The radio galaxy 3C 75 is remarkable because it contains a pair of radio-loud active galaxies, each of which produces a two-sided jet, with the jet beams appearing to collide and merge to the west of the galaxies. Motivated by 3C 75, we have conducted three-dimensional hydrodynamic simulations of jet collisions. We have extended previous studies by modelling the physical properties of the cluster atmosphere, including an external wind, and using realistic jet powers obtained from observational data. We are able to produce a morphology similar to that of 3C 75. The simulations imply that direct contact between the bulk jet flows on the west of the source is required to produce a morphology consistent with 3C 75. We quantify how the merging jets decelerate, how the wind deflects the jets and cocoons, the entrainment of intra-cluster material into the cocoons, the cocoon energetics, and how the jet interactions generate enstrophy. By comparing simulations of pairs of two-sided jets with those of single two-sided sources, we determine how the interaction between two bipolar jets changes their evolution. The unprecedented sensitivity and angular resolution of upcoming observatories will lead to the detection of many more complex sources at high redshift, where interacting jets are expected to be more numerous. The morphology of these complex sources can provide significant insight into the conditions in their environments.

Musoke, G.↗

Prospect for measuring the CP phase in the $h\tau\tau$ coupling at the LHC

The search for a new source of CP violation is one of the most important endeavors in particle physics. A particularly interesting way to perform this search is to probe the CP phase in the $h\tau\tau$ coupling, as the phase is currently completely unconstrained by all existing data. Recently, a novel variable $\Theta$ was proposed for measuring the CP phase in the $h\tau\tau$ coupling through the $\tau^\pm \to \pi^\pm \pi^0 \nu$ decay mode. We examine two crucial questions that the real LHC detectors must face, namely, the issue of neutrino reconstruction and the effects of finite detector resolution. For the former, we find strong evidence that the collinear approximation is the best for the $\Theta$ variable. For the latter, we find that the angular resolution is actually not an issue even though the reconstruction of $\Theta$ requires resolving the highly collimated $\pi^\pm$'s and $\pi^0$'s from the $\tau$ decays. Instead, we find that it is the missing transverse energy resolution that significantly limits the LHC reach for measuring the CP phase via $\Theta$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Two Phase (Liquid/Gas) Xenon Gamma-Camera for the Detection of Special Nuclear Material and PET Medical Imaging

The McKinsey group at Yale has been awarded a grant from DTRA for the building of a Liquid Xenon Gamma Ray Color Camera (LXe-GRCC), which combines state-of-the-art detection of LXe scintillation light and time projection chamber (TPC) charge readout. The DTRA application requires a movable detector and hence only a single phase (liquid) xenon detector can be considered in this case. We propose to extend the DTRA project to applications that allow a two phase (liquid/gas) xenon TPC. This entails additional (yet minimal) hardware and extension of the research effort funded by DTRA. The two phase detector will have better energy and angular resolution. Such detectors will be useful for PET medical imaging and detection of special nuclear material in stationary applications (e.g. port of entry). The expertise of the UConn group in gas phase TPCs will enhance the capabilities of the Yale group and the synergy between the two groups will be very beneficial for this research project as well as the education and research projects of the two universities. The LXe technology to be used in this project has matured rapidly over the past few years, developed for use in detectors for nuclear physics and astrophysics. This technology may now be applied in a straightforward way to the imaging of gamma rays. According to detailed Monte Carlo simulations recently performed at Yale University, energy resolution of 1% and angular resolution of 3 degrees may be obtained for 1.0 MeV gamma rays, using existing technology. With further research and development, energy resolution of 0.5% and angular resolution of 1.3 degrees will be possible at 1.0 MeV. Because liquid xenon is a high density, high Z material, it is highly efficient for scattering and capturing gamma rays. In addition, this technology scales elegantly to large detector areas, with several square meter apertures possible. The Yale research group is highly experienced in the development and use of noble liquid detectors for astrophysics, most recently in the XENON10 experiment. The existing facilities at Yale are fully adequate for the completion of this project. The facilities of the UConn group at the LNS at Avery Point include a (clean) lab for detector development and this group recently delivered an Optical Readout TPC (O-TPC) for research in Nuclear Astrophysics at the TUNL in Duke University. The machine shop at UConn will be used (free of charge) for producing the extra hardware needed for this project including grids and frames.

07 ISOTOPE AND RADIATION SOURCES↗

A Massive Molecular Outflow in the Dense Dust Core AGAL G337.916-00.477

Massive molecular outflows erupting from high-mass young stellar objects (YSOs) provide important clues to understanding the mechanism of high-mass star formation. Based on new CO J = 3–2 and J = 1–0 observations using the Atacama Submillimeter Telescope Experiment (ASTE) and Mopra telescope facilities, we discovered a massive bipolar outflow associated with the dense dust core AGAL G337.916-00.477 (AGAL337.9-S), located 3.48 kpc from the Sun. The outflow lobes have extensions of less than 1 pc—and thus were not fully resolved in the angular resolutions of ASTE and Mopra—and masses of ∼50 M {sub ⊙}. The maximum velocities of the outflow lobes are as high as 36–40 km s{sup −1}. Our analysis of the infrared and submillimeter data indicates that AGAL337.9-S is in an early evolutionary stage of high-mass star formation, having the total far-infrared luminosity of ∼5×10{sup 4} L{sub ⊙}. We also found that another dust core, AGAL G337.922-00.456 (AGAL337.9-N), located 2′ north of AGAL337.9-S, is a high-mass YSO in an earlier evolutionary stage than AGAL337.9-S, as it is less bright in the mid-infrared than AGAL337.9-S.

79 ASTRONOMY AND ASTROPHYSICS↗

A Light and Effective Wide Field Monitor for Gamma Ray Bursts and Transient Sources

We present here a concept for a light and low-power wide field monitor working in the X-ray range, suitable for simultaneous imaging of large portions of the sky and GRB localizations. Our concept evolves from and improves on the design of the 5-kg SuperAGILE experiment, flying on the AGILE mission and currently delivering arcmin-localizations of GRBs at a rate of about 1/month. Similar to SuperAGILE, our concept is based on position sensitive silicon detectors equipped with one-dimensional coded masks. Different options are available for the detector, whose properties, combined with the scientific requirements, drive the design of the experiment. Our approach is based on a modular detector. The experiment design can then be tailored to specific scientific goals of the experiment or the mission (e.g., to cite GRBs only: the brightest GRBs/XRFs on a large field of view - FoV, or many low-fluence GRBs/XRFs on a smaller FoV, or the low energy spectrum of the prompt event, or the detection of high-z GRBs). In this paper we describe the concept, the main detector properties and outline some possible experiment configurations, with examples of their expected performance. Different experiment configurations in terms of area, FoV, angular resolution may be designed starting from the same detectors. Instead, the band-pass is mostly related to the detector properties. A key point of our project is the high degree of readiness of the detectors that are at production level and may be immediately proposed for a future experiment onboard missions with high readiness requirements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization fraction of Planck Galactic cold clumps and forecasts for the Simons Observatory

ABSTRACT We measure the mean-squared polarization fraction of a sample of 6282 Galactic cold clumps at 353 GHz, consisting of Planck Galactic cold clump (PGCC) catalogue category 1 objects [flux densities measured with signal-to-noise ratio (S/N) > 4]. At 353 GHz, we find the mean-squared polarization fraction, which we define as the mean-squared polarization divided by the mean-squared intensity, to be (4.79 ± 0.44) × 10−4 equation to an $11\, \sigma$ detection of polarization. We test if the polarization fraction depends on the clumps’ physical properties, including flux density, luminosity, Galactic latitude, and physical distance. We see a trend towards increasing polarization fraction with increasing Galactic latitude, but find no evidence that polarization depends on the other tested properties. The Simons Observatory, with angular resolution of order 1 arcmin and noise levels between 22 and $54\, \mu$K−arcmin at high frequencies, will substantially enhance our ability to determine the magnetic field structure in Galactic cold clumps. At $\ge 5\, \sigma$ significance, we predict the Simons Observatory will detect at least ∼12 000 cold clumps in intensity and ∼430 cold clumps in polarization. This number of polarization detections would represent a two orders of magnitude increase over the current Planck results. We also release software that can be used to mask these Galactic cold clumps in other analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectroscopy of states in 136 Ba using the 138 Ba(p,t) reaction

Background: The 136 Ba isotope is the daughter nucleus in 136 Xe $ββ$ decay. It also lies in a shape transitional region of the nuclear chart, making it a suitable candidate to test a variety of nuclear models. Purpose: To obtain spectroscopic information on states in 136 Ba, which will allow a better understanding of its low-lying structure. These data may prove useful to constrain future 136 Xe → 136 Ba neutrinoless $ββ$ decay matrix element calculations. Methods: Here, a 138 Ba(p, t) reaction was used to populate states in 136 Ba up to approximately 4.6 MeV in excitation energy. The tritons were detected using a high-resolution Q3D magnetic spectrograph. A distorted wave Born approximation analysis was performed for the measured triton angular distributions. Results: 102 excited states in 136 Ba were observed, out of which 52 are reported for the first time. Definite spin-parity assignments are made for 26 newly observed states, while previously ambiguous assignments for ten other states are resolved. Together with other available data, the results are used to determine level densities in 136 Ba. These were compared with theory predictions, obtained using shell model calculations with Hamiltonians previously used for 136 Xe neutrinoless $ββ$ decay matrix element evaluations. Conclusions: The shell model predicted level densities agree reasonably well for the two Hamiltonians. However the results for theory and experiment are found to agree only at lower energies, diverging from one another for the higher lying states, with the discrepancy increasing with energy. This is presumably because of lower production cross sections for a majority of the higher-lying predicted states and the experimental limitations in resolving a large number of nearly degenerate states predicted by the theory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design of optical/IR blocking filters for the Lynx X-ray Microcalorimeter [Design of optical/IR blocking filters for the Lynx S-ray Microcalorimeter (LXM)]

The Lynx mission concept, under development ahead of the 2020 Astrophysics Decadal Review, includes the Lynx X-ray Microcalorimeter (LXM) as one of its main instruments. The LXM uses a microcalorimeter array at the focus of a high-throughput soft x-ray telescope to enable high-resolution nondispersive spectroscopy in the soft x-ray waveband (0.2 to 15 keV) with exquisite angular resolution. Similar to other x-ray microcalorimeters, the LXM uses a set of blocking filters mounted within the dewar that pass the photons of interest (x-rays) while attenuating the out-of-band long-wavelength radiation. Such filters have been successfully used on previous orbital and suborbital instruments; yet, the Lynx science objectives, which emphasize observations in the soft x-ray band (<1 keV), pose more challenging requirements on the set of LXM blocking filters. We present an introduction to the design of the LXM optical/IR blocking filters and discuss recent advances in filter capability targeted at LXM. In addition, we briefly describe the external filters and the modulated x-ray sources to be used for onboard detector calibration.

79 ASTRONOMY AND ASTROPHYSICS↗

Frame average optimization of cine-mode EPID images used for routine clinical in vivo patient dose verification of VMAT deliveries

Purpose: The in vivo 3D dose delivered to a patient during volumetric modulated arc therapy (VMAT) delivery can be calculated using electronic portal imaging device (EPID) images. These images must be acquired in cine-mode (i.e., “movie” mode) in order to capture the time-dependent delivery information. The angle subtended by each cine-mode EPID image during an arc can be changed via the frame averaging number selected within the image acquisition software. A large frame average number will decrease the EPID’s angular resolution and will result in a decrease in the accuracy of the dose information contained within each image. Alternatively, less EPID images acquired per delivery will decrease the overall 3D patient dose calculation time, which is appealing for large-scale clinical implementation. Therefore, the purpose of this study was to determine the optimal frame average value per EPID image, defined as the highest frame averaging that can be used without an appreciable loss in 3D dose reconstruction accuracy for VMAT treatments. Methods: Six different VMAT plans and six different SBRT-VMAT plans were delivered to an anthropomorphic phantom. Delivery was carried out on a Varian 2300ix model linear accelerator (Linac) equipped with an aS1000 EPID running at a frame acquisition rate of 7.5 Hz. An additional PC was set up at the Linac console area, equipped with specialized frame-grabber hardware and software packages allowing continuous acquisition of all EPID frames during delivery. Frames were averaged into “frame-averaged” EPID images using MATLAB. Each frame-averaged data set was used to calculate the in vivo dose to the patient and then compared to the single EPID frame in vivo dose calculation (the single frame calculation represents the highest possible angular resolution per EPID image). A mean percentage dose difference of low dose (<20% prescription dose) and high dose regions (>80% prescription dose) was calculated for each frame averaged scenario for each plan. The authors defined their unacceptable loss of accuracy as no more than a ±1% mean dose difference in the high dose region. Optimal frame average numbers were then determined as a function of the Linac’s average gantry speed and the dose per fraction. Results: The authors found that 9 and 11 frame averages were suitable for all VMAT and SBRT-VMAT treatments, respectively. This resulted in no more than a 1% loss to any of the dose region’s mean percentage difference when compared to the single frame reconstruction. The optimized number was dependent on the treatment’s dose per fraction and was determined to be as high as 14 for 12 Gy/fraction (fx), 15 for 8 Gy/fx, 11 for 6 Gy/fx, and 9 for 2 Gy/fx. Conclusions: The authors have determined an optimal EPID frame averaging number for multiple VMAT-type treatments. These are given as a function of the dose per fraction and average gantry speed. These optimized values are now used in the authors’ clinical, 3D, in vivo patient dosimetry program. This provides a reduction in calculation time while maintaining the authors’ required level of accuracy in the dose reconstruction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Recent Cross-Section Results from MicroBooNE

MicroBooNE is a liquid argon time projection chamber in the Booster Neutrino Beam at Fermilab. The large event rate and 3 mm wire spacing of the detector provide high-statistics, precise-resolution imaging of neutrino interactions leading to low-threshold, high-efficiency event reconstruction with full angular coverage. As such, this is an ideal place to probe neutrino-argon interactions in the hundreds-of-MeV to few-GeV energy range, and to study the impact of nuclear effects through detailed measurements of hadronic final states. These proceedings present recent measurements of neutrino interactions in MicroBooNE, including inclusive charged-current interactions, neutral-pion production, and measurements of low-energy protons.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detailed Characterization of CZT Detector Response for Improved Coded-Aperture Imaging Performance

Gamma-ray imaging is a powerful method for locating and quantifying sources of radiation. The coded-aperture technique demonstrates superior angular resolution in comparison to other methods (e.g., Compton reconstruction). In this method, a mask constructed of highly attenuating material encodes the scene as a shadow pattern on a position-sensitive detector; this pattern can then be used to recreate the origin(s) of incident radiation. This is typically done through convolution of the mask and shadow patterns. Iterative methods which attempt to reconstruct the observed shadow pattern using a weighted combination of simulated patterns may also be employed. In either case, errors in event position reconstruction due to detector imperfections alter the shadow pattern and will therefore degrade system performance and may introduce imaging artifacts. These effects can be mitigated with a detailed understanding of such errors – allowing for the generation of representative simulations that include the errors and/or correction of raw imager data to remove the errors. We present a calibration process for a commercially available cadmium zinc telluride (CZT) gamma imager which provides a comprehensive characterization of the spatial and energy dependence of event reconstruction. By illuminating a mask featuring a regular grid of pinholes with a calibration source, the localized response of the detector can be measured with fine granularity. These local responses are combined to generate a full detector response map which can be used to distort simulations in a manner that is representative of the observed detector data. Details of the calibration procedure and an assessment of the impact of its end products on the performance of iterative imaging methods will be presented.

Ziock, Klaus-Peter↗