Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Experimental Heat Transfer Results and Flow Visualization of Vertical Upflow Boiling in Earth Gravity with Subcooled Inlet Conditions – In Preparation for Experiments Onboard the International Space Station

Since 2012, researchers at the Purdue University Boiling and Two-Phase Flow Laboratory (PU-BTPFL) and NASA Glenn Research Center have been collaborating on a long-term effort to study flow boiling and condensation in microgravity. The ultimate goal has been to develop the Flow Boiling and Condensation Experiment (FBCE) for the International Space Station (ISS). Based on the findings from prior flow boiling experiments both at different orientations in Earth gravity and onboard parabolic flights simulating short durations of microgravity, a final refined experiment design, construction, and operating procedure have been arrived at for long-duration microgravity flow boiling experiments onboard the ISS. This study investigates flow boiling of n-Perfluorohexane with subcooled inlet in a rectangular channel of dimensions 114.6 mm heated length, 2.5 mm width, and 5 mm height. These pre-launch experiments (Mission Sequence Testing) were conducted in vertical upflow orientation in Earth gravity using the same experimental rig that was launched to the ISS in August 2021. The various operating parameters varied are heating configuration (single- and double-sided), mass velocity (180 – 3200 kg/m2s), inlet subcooling (+0 – 32°C, encompassing both highly subcooled and near-saturated inlet conditions), and inlet pressure (119 – 191 kPa). High-speed video flow visualization images are presented to explain the two-phase interfacial physics within the channel’s heated section. Heat transfer results in terms of flow boiling curves, streamwise profiles of wall temperature and heat transfer coefficient, and averaged heat transfer coefficients are analyzed and parametric effects elucidated. Severe temporal thermodynamic equilibrium is observed for near-saturated inlet at very low velocities. Nucleate boiling degradation starts at larger heat fluxes for single-sided heating than double sided at low mass velocities with highly subcooled inlet, and conversely at high mass velocities with near-saturated inlet. Nucleate boiling degradation can be delayed to higher heat fluxes by highly subcooling the inlet and increasing mass velocity. The entire local heat transfer coefficient profiles are degraded at higher heat fluxes for near-saturated inlet, but only the downstream part for highly subcooled inlet. This study also confirmed reliability of the upcoming ISS experimental data for subcooled inlet conditions and the collected Earth-gravity data will be used for comparison against the ISS data.

flow boiling↗

Integral Channel Nozzles and Heat Exchangers using Additive Manufacturing Directed Energy Deposition NASA HR-1 Alloy

Heat exchangers for use in propulsion applications are very critical components because they must be efficient, compact and light and often operate with working fluids at extreme temperatures or pressures or both. Various components and systems use heat exchangers such as combustion chambers of gas turbines and internal combustion engines, fuel cells (air supply and thermal management), electric batteries (thermal management), evaporators and recuperators of waste-heat-to-power systems, and rocket engines. Even if the results are more generally applicable, the heat exchangers applications to which this study is more closely related are regeneratively cooled rocket nozzles and chambers, and repressurization systems for the launch vehicles. These components are often thin-walled and contain pressurized fluids, like propellants at cryogenic or elevated temperatures. Given that the environments that these propulsion components must endure are challenging, the manufacturing to meet these specifications often require long lead times due to specialty processes and unique tooling associated with the combined thin-wall integral channel and large-scale structures. Additive manufacturing (AM) offers programmatic advantages for reduction in processing time and cost in addition to various technical advantages, including the possibility to achieve enhanced hardware complexity targeted to superior performance, part consolidation, and the capability of processing of novel alloys. While AM is already being utilized for heat exchanger components in propulsion applications, almost all these AM components are made by means of Laser Powder Bed Fusion (L-PBF). L-PBF allows for fine features but is rather limited with respect to the overall size of the components that can be manufactured. Recent developments are maturing the Laser Powder Directed Energy Deposition (LP-DED) process which may be used, for example, to make integral channel thin-wall regeneratively-cooled rocket nozzles with diameters greater than 1 m. This paper highlights some integral channel heat exchanger demonstrator hardware applications of LP-DED, as well as the characterization of this process in combination with the use of the NASA HR-1 alloy. To properly utilize LP-DED for heat exchanger manufacturing, various aspects are being characterized such as geometry limitations, measurement of surface texture and geometric angled surfaces, surface enhancements for internal channels, and material evaluation. NASA HR-1 (FeNi-Cr) is a high strength hydrogen resistant superalloy developed for use in aerospace applications, such as heat exchangers. Some aspects and considerations about the design of heat exchangers are summarized together with data relevant to LP-DED manufacturing in combination with the NASA HR-1 alloy. Microchannels were successful deposited down to 2.54 mm and 1 mm wall thickness, wall angles of 30°, both with high reproducibility. It was also found that the areal surface roughness is highly dependent on the size of the powder feedstock used for deposition. The characterization of these LP-DED features is critical for fluid flow and heat transfer predictions as it can be exploited to enhance heat transfer at the cost of increased pressure drop.

Additive Manufacturing↗

Integral Channel Nozzles and Heat Exchangers using Additive Manufacturing Directed Energy Deposition NASA HR-1 Alloy

Heat exchangers for use in propulsion applications are very critical components because they must be efficient, compact and light and often operate with working fluids at extreme temperatures or pressures or both. Various components and systems use heat exchangers such as combustion chambers of gas turbines and internal combustion engines, fuel cells (air supply and thermal management), electric batteries (thermal management), evaporators and recuperators of waste-heat-to-power systems, and rocket engines. Even if the results are more generally applicable, the heat exchangers applications to which this study is more closely related are regeneratively cooled rocket nozzles and chambers, and repressurization systems for the launch vehicles. These components are often thin-walled and contain pressurized fluids, like propellants at cryogenic or elevated temperatures. Given that the environments that these propulsion components must endure are challenging, the manufacturing to meet these specifications often require long lead times due to specialty processes and unique tooling associated with the combined thin-wall integral channel and large-scale structures. Additive manufacturing (AM) offers programmatic advantages for reduction in processing time and cost in addition to various technical advantages, including the possibility to achieve enhanced hardware complexity targeted to superior performance, part consolidation, and the capability of processing of novel alloys. While AM is already being utilized for heat exchanger components in propulsion applications, almost all these AM components are made by means of Laser Powder Bed Fusion (L-PBF). L-PBF allows for fine features but is rather limited with respect to the overall size of the components that can be manufactured. Recent developments are maturing the Laser Powder Directed Energy Deposition (LP-DED) process which may be used, for example, to make integral channel thin-wall regeneratively-cooled rocket nozzles with diameters greater than 1 m. This paper highlights some integral channel heat exchanger demonstrator hardware applications of LP-DED, as well as the characterization of this process in combination with the use of the NASA HR-1 alloy. To properly utilize LP-DED for heat exchanger manufacturing, various aspects are being characterized such as geometry limitations, measurement of surface texture and geometric angled surfaces, surface enhancements for internal channels, and material evaluation. NASA HR-1 (FeNi-Cr) is a high strength hydrogen resistant superalloy developed for use in aerospace applications, such as heat exchangers. Some aspects and considerations about the design of heat exchangers are summarized together with data relevant to LP-DED manufacturing in combination with the NASA HR-1 alloy. Microchannels were successful deposited down to 2.54 mm and 1 mm wall thickness, wall angles of 30°, both with high reproducibility. It was also found that the areal surface roughness is highly dependent on the size of the powder feedstock used for deposition. The characterization of these LP-DED features is critical for fluid flow and heat transfer predictions as it can be exploited to enhance heat transfer at the cost of increased pressure drop.

additive manufacturing↗

Baltimore Energy & Infrastructure: Assessing Urban Heat Vulnerability in Baltimore Neighborhoods to Inform Transportation Resiliency Planning Efforts

Across the world, climate change is altering cities and their local climate systems. Following global trends of rising mean temperatures, Baltimore, Maryland is projected to experience more frequent extreme heat events. Exacerbated by Urban Heat Island (UHI) effects, residents of the city face high temperatures from limited tree canopy, highly paved and impervious surfaces, limited air flow, and high concentrations of localized emissions. Urban heat is dispersed asymmetrically, with historically marginalized populations experiencing disproportionately severe heat. Recognizing the impacts of extreme urban heat, the Maryland Transit Administration (MTA) collaborated with us, the Spring 2024 Goddard Energy and Infrastructure NASA DEVELOP team to assess urban impacts of MTA users and assets and explore opportunities to enhance resiliency planning. We evaluated the feasibility of NASA Earth observations (EOs) in visualizing heat vulnerability in Baltimore City and County. We mapped UHI and extreme heat using remote sensing observations, tailored a Heat Priority Score (HPS) to analyze heat data in tandem with socioeconomic data from American Community Survey (ACS), and utilized SOlar and LongWave Environmental Irradiance Geometry (SOLWEIG) model to estimate MTA riders’ thermal comfort. NASA EOs served to quantify the distribution and severity of extreme heat at the block group level, which was found to correlate with a lack of vegetation and presence of densely built-up surroundings. The HPS revealed that extreme heat events most negatively impact communities that exhibit social vulnerability through indicators such as age, race, and income. These findings will inform neighborhood resiliency plans for the MTA that can be incorporated into their Adaptation Resiliency Toolbox (ART).

Baltimore,↗

Study of fuel cell powerplant with heat recovery

It was shown that heat can be recovered from fuel cell power plants by replacing the air-cooled heat exchangers in present designs with units which transfer the heat to the integrated utility system. Energy availability for a 40-kW power plant was studied and showed that the total usable energy at rated power represents 84 percent of the fuel lower heating value. The effects of design variables on heat availability proved to be small. Design requirements were established for the heat recovery heat exchangers, including measurement of the characteristics of two candidate fuel cell coolants after exposure to fuel cell operating conditions. A heat exchanger test program was defined to assess fouling and other characteristics of fuel cell heat exchangers needed to confirm heat exchanger designs for heat recovery.

King, J. M.↗

Heat pipes in space and on earth

The heat pipe is a closed tube whose inner surfaces are lined with a porous capillary wick. The wick is saturated with the liquid phase of a working fluid. The heat supplied at one end of the tube, the evaporator, causes evaporation of the working fluid. The vapor will pass to the other end of the tube, the condenser, where it will condense and release the latent heat of vaporization to a heat sink in that section of the pipe. Problems concerning a design of heat pipes for space applications are related to certain difficulties regarding the prediction of device performance under zero-g conditions. Heat pipes are usually tested on the ground under the influence of gravity, and then their performance is extrapolated to space. A description is presented of the approaches used to insure good heat pipe performance in space. Attention is given to an international heat pipe experiment conducted to accumulate zero-g performance data for several new and unique heat pipe designs, heat pipes for ATS-6, cryogenic heat pipes, and future activities.

Ollendorf, S.↗

Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 3: 25% Partitioned Blades

The icing protection obtained from an internally air-heated propeller blade partitioned to confine the heated air forward of 25-percent chord was investigated in the NACA Cleveland icing research tunnel. A production-model hollow steel propeller was modified with an Internal radial partition at 25-percent chord and with shank and tip openings to admit and exhaust the heated air. Temperatures were measured on the blade surfaces and in the heated-air system during tunnel icing conditions. Heat-exchanger effectiveness and photographs of Ice formations on the blades were obtained. Surface temperature measurements indicated that confining the heated air forward of the 25-percent chord gave.a more economical distribution of the applied heat as compared with unpartitioned and 50-percent partitioned blades, by dissipating a greater percentage of the available heat at the leading edge. At a propeller speed of 850 rpm, a heating rate of 7000 Btu per hour per blade at a shank air temperature of 400 F provided adequate Icing protection at ambient-air temperatures of 23 F but not at temperatures as low as 15 F. With the heating rate used, a heat-exchanger effectiveness of 77 percent was obtained as compared to 56 percent for 50-percent partitioned and 47 percent for unpartitioned blades.

Mulholland, Donald R.↗

Experiments on fuel heating for commercial aircraft

An experimental jet fuel with a -33 C freezing point was chilled in a wing tank simulator with superimposed fuel heating to improve low temperature flowability. Heating consisted of circulating a portion of the fuel to an external heat exchanger and returning the heated fuel to the tank. Flowability was determined by the mass percent of unpumpable fuel (holdup) left in the simulator upon withdrawal of fuel at the conclusion of testing. The study demonstrated that fuel heating is feasible and improves flowability as compared to that of baseline, unheated tests. Delayed heating with initiation when the fuel reaches a prescribed low temperature limit, showed promise of being more efficient than continuous heating. Regardless of the mode or rate of heating, complete flowability (zero holdup) could not be restored by fuel heating. The severe, extreme-day environment imposed by the test caused a very small amount of subfreezing fuel to be retained near the tank surfaces even at high rates of heating. Correlations of flowability established for unheated fuel tests also could be applied to the heated test results if based on boundary-layer temperature or a solid index (subfreezing point) characteristic of the fuel.

Friedman, R.↗

Heating experiments for flowability improvement of near-freezing aviation fuel

An experimental jet fuel with a -33 C freezing point was chilled in a wing tank simulator with superimposed fuel heating to improve low temperature flowability. Heating consisted of circulating a portion of the fuel to an external heat exchanger and returning the heated fuel to the tank. Flowability was determined by the mass percent of unpumpable fuel (holdup) left in the simulator upon withdrawal of fuel at the conclusion of testing. The study demonstrated that fuel heating is feasible and improves flowability as compared to that of baseline, unheated tests. Delayed heating with initiation when the fuel reaches a prescribed low temperature limit, showed promise of being more efficient than continuous heating. Regardless of the mode or rate of heating, complete flowability (zero holdup) could not be restored by fuel heating. The severe, extreme-day environment imposed by the test caused a very small amount of subfreezing fuel to be retained near the tank surfaces even at high rates of heating. Correlations of flowability established for unheated fuel tests also could be applied to the heated test results if based on boundary-layer temperature or a solid index (subfreezing point) characteristic of the fuel. Previously announced in STAR as N82-26483

Friedman, R.↗

Development of an integrated heat pipe-thermal storage system for a solar receiver

An integrated heat pipe-thermal storage system was developed as part of the Organic Rankine Cycle Solar Dynamic Power System solar receiver for space station application. The solar receiver incorporates potassium heat pipe elements to absorb and transfer the solar energy within the receiver cavity. The heat pipes contain thermal energy storage (TES) canisters within the vapor space with a toluene heater tube used as the condenser region of the heat pipe. During the insolation period of the earth orbit, solar energy is delivered to the heat pipe. Part of this thermal energy is delivered to the heater tube and the balance is stored in the TES units. During the eclipse period of earth orbit, the stored energy in the TES units is transferred by the potassium vapor to the toluene heater tube. A developmental heat pipe element was constructed that contains axial arteries and a distribution wick connecting the toluene heater and the TES units to the solar insolation surface of the heat pipe. Tests were conducted to demonstrate the heat pipe, TES units, and the heater tube operation. The heat pipe element was operated at design input power of 4.8 kW. Thermal cycle tests were conducted to demonstrate the successful charge and discharge of the TES units. Axial power flux levels up to 15 watts/sq cm were demonstrated and transient tests were conducted on the heat pipe element. Details of the heat pipe development and test procedures are presented.

Keddy, E.↗

Capillary-Condenser-Pumped Heat-Transfer Loop

Heat being transferred supplies operating power. Capillary-condenser-pumped heat-transfer loop similar to heat pipe and to capillary-evaporator-pumped heat-transfer loop in that heat-transfer fluid pumped by evaporation and condensation of fluid at heat source and sink, respectively. Capillary condenser pump combined with capillary evaporator pump to form heat exchanger circulating heat-transfer fluids in both loops. Transport of heat more nearly isothermal. Thermal stress in loop reduced, and less external surface area needed in condenser section for rejection of heat to heat sink.

Silverstein, Calvin C.↗

Influence of heating mode on three-dimensional mantle convection

Numerical models of three-dimensional thermal convection in highly viscous spherical shells with different combinations of internal and basal heating consistently have upwelling concentrations in the form of cylindrical plumes and downwelling in planar sheets. As the proportion of internal heating increases, the number of upwelling plumes increases, and downwelling sheets become more vigorous and time-dependent. With any amount of basal heating, the entire convective pattern, during its evolution, is anchored to the upwelling plumes. As the proportion of internal heating increases, the heat flow carried by the upwelling plumes remains a large fraction of the basal heat flow. Downwelling sheets carry only a minor fraction (approximately 30 percent) of the basal heat flow (even when the shell is entirely heated from below), but they advect almost all of the internally generated heat. The relatively large number of plumes in the earth's mantle (inferred from hotspots), the possibility that downwelling slabs are vigorous enough to penetrate the lower mantle, and the small fraction of terrestrial surface heat flow carried by plumes all suggest that the mantle is predominantly heated from within.

Bercovici, D.↗

Aerodynamic pressure and heating-rate distributions in tile gaps around chine regions with pressure gradients at a Mach number of 6.6

Surface and gap pressures and heating-rate distributions were obtained for simulated Thermal Protection System (TPS) tile arrays on the curved surface test apparatus of the Langley 8-Foot High Temperature Tunnel at Mach 6.6. The results indicated that the chine gap pressures varied inversely with gap width because larger gap widths allowed greater venting from the gap to the lower model side pressures. Lower gap pressures caused greater flow ingress from the surface and increased gap heating. Generally, gap heating was greater in the longitudinal gaps than in the circumferential gaps. Gap heating decreased with increasing gap depth. Circumferential gap heating at the mid-depth was generally less than about 10 percent of the external surface value. Gap heating was most severe at local T-gap junctions and tile-to-tile forward-facing steps that caused the greatest heating from flow impingement. The use of flow stoppers at discrete locations reduced heating from flow impingement. The use of flow stoppers at discrete locations reduced heating in most gaps but increased heating in others. Limited use of flow stoppers or gap filler in longitudinal gaps could reduce gap heating in open circumferential gaps in regions of high surface pressure gradients.

Hunt, L. Roane↗

Heat pipe radiation cooling of advanced hypersonic propulsion system components

Heat transfer, heat pipe, and system studies were performed to assess the newly proposed heat pipe radiation cooling (HPRC) concept. With an HPRC system, heat is removed from the ramburner and nozzle of a hypersonic aircraft engine by a surrounding, high-temperature, heat pipe nacelle structure, transported to nearby external surfaces, and rejected to the environment by thermal radiation. With HPRC, the Mach number range available for using hydrocarbon fuels for aircraft operation extends into the Mach 4 to Mach 6 range, up from the current limit of about Mach 4. Heat transfer studies using a newly developed HPRC computer code determine cooling system and ramburner and nozzle temperatures, heat loads, and weights for a representative combined-cycle engine cruising at Mach 5 at 80,000 ft altitude. Heat pipe heat transport calculations, using the Los Alamos code HTPIPE, reveal that adequate heat trasport capability is available using molybdenum-lithium heat pipe technology. Results show that the HPRC system radiator area is limited in size to the ramburner-nozzle region of the engine nacelle; reasonable system weights are expected; hot section temperatures are consistent with advanced structural materials development goals; and system impact on engine performance is minimal.

Martin, R. A.↗

Transient response of a high-capacity heat pipe for Space Station Freedom

High-capacity heat pipe radiator panels have been proposed as the primary means of heat rejection for Space Station Freedom. In this system, the heat pipe would interface with the thermal bus condensers. Changes in system heat load can produce large temperature and heat load variations in individual heat pipes. Heat pipes could be required to start from an initially cold state, with heat loads temporarily exceeding their low-temperature transport capacity. The present research was motivated by the need for accurate prediction of such transient operating conditions. In this work, the cold startup of a 6.7-meter long high-capacity heat pipe is investigated experimentally and analytically. A transient thermohydraulic model of the heat pipe was developed which allows simulation of partially-primed operation. The results of cold startup tests using both constant temperature and constant heat flux evaporator boundary conditions are shown to be in good agreement with predicted transient response.

Ambrose, J. H.↗

Analytical and experimental studies of heat pipe radiation cooling of hypersonic propulsion systems

Analytical and experimental studies were completed to assess the feasibility of using high-temperature heat pipes to cool hypersonic engine components. This new approach involves using heat pipes to transport heat away from the combustor, nozzle, or inlet regions, and to reject it to the environment by thermal radiation from an external heat pipe nacelle. For propulsion systems using heat pipe radiation cooling (HPRC), it is possible to continue to use hydrocarbon fuels into the Mach 4 to Mach 6 speed range, thereby enhancing the economic attractiveness of commercial or military hypersonic flight. In the second-phase feasibility program recently completed, it is found that heat loads produced by considering both convection and radiation heat transfer from the combustion gas can be handled with HPRC design modifications. The application of thermal insulation to ramburner and nozzle walls was also found to reduce the heat load by about one-half and to reduce peak HPRC system temperatures to below 2700 F. In addition, the operation of HPRC at cruise conditions of around Mach 4.5 and at an altitude of 90,000 ft lowers the peak hot-section temperatures to around 2800 F. An HPRC heat pipe was successfully fabricated and tested at Mach 5 conditions of heat flux, heat load, and temperature.

Martin, R. A.↗

The vertical structure of diabatic heating associated with the Madden-Julian oscillation simulated by the Goddard Laboratory for Atmospheres climate model

The diabatic heating structure of the nine-layer Goddard Laboratory for Atmospheres model of the Madden-Julian oscillation (MJO) is illustrated with composite charts made for those times when this low-frequency mode reaches its maximum and minimum amplitudes. These composite charts compare the vertically integrated diabatic heating with potential functions, the vertical distribution of diabatic heating with the east-west mass flux function in the tropics, and the vertical profiles of diabatic heating at the centers of maximum and minimum MJO amplitude. Three interesting features of the model MJO's diabatic heating are revealed: (1) the maximum heating rate of this low-frequency mode is located over the Asian monsoon region and its amplitude is about a half of the maximum value of the seasonal mean heating rate in this region, (2) the vertical diabatic heating rate profile has a maximum at 500 mbar and resembles the seasonal mean total heating profile, and (3) the total diabatic heating is for the most part composed of the latent heat released by cumulus convection.

Chen, Tsing-Chang↗

Vaporization heat transfer of dielectric liquids on enhanced surfaces covered with screen wicks

Experiments were conducted to investigate the vaporization heat transfer characteristics for the dielectric liquid FC-72 on several wicking surfaces which may be used in flat-plate heat pipes. The wicking materials studied included microstructure enhanced surfaces and coarse surfaces covered with screen meshes. Experimental data for q versus deltaT curves and critical heat fluxes were obtained for the two different operating conditions of a heat pipe, evaporation, and shallow pool boiling. When the liquid level was above the heated surface, the height of the liquid level above the surface was varied from 0 to 10 mm. When the liquid level was below the heated surface, the distance from the liquid level to the edge of the surface was adjusted from 0 to 15 mm. Experimental results revealed that for shallow pool boiling when the heated surface was covered with a wire screen mesh, the heat transfer coefficient increased at lower heat fluxes but the critical heat flux (CHF) decreased for all the surfaces tested. In the case of evaporation, both CHF and the heat transfer coefficient increased as the microstructure surfaces were covered with screen meshes.

Gu, C. B.↗