Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “heat transfer loop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

MCNP Models for Tokamak Cooling Water System Equipment Evaluations

Heat generated in the ITER fusion reactor is deposited in the tokamak vacuum vessel, in-vessel components, and in the components of the neutral beam injector during plasma operations and during subsequent decay of activation products. This heat is managed by the tokamak cooling water system (TCWS). The stainless steel material in the integrated loop of blanket edge-localized mode vertical stabilization coils and divertor (IBED) components (e.g., piping, heat exchangers (HXs), and pumps) contains activation sources because of its exposure primarily to neutron radiation from the decay of 17 N, which is a short-lived radionuclide produced by neutron capture reactions with oxygen nuclei in the IBED primary heat transfer system (PHTS) cooling water during plasma operations. A detailed geometry model of the IBED stainless steel components and neutron radiation sources is required for an accurate assessment of the gamma activation sources on level 3 of the tokamak building. In the baseline design, each of the eight IBED PHTS cooling trains has two shell-and-tube heat exchangers (HXs) connected in series. Because these HXs are very large and contain a large amount of radioactive water, the possibility of using compact HXs of the welded shell-and-plate type is under investigation. This paper presents two Monte Carlo N-Particle (MCNP) TCWS geometry models, one model for each HX type, along with the associated piping. These models were obtained by automatic geometry conversion from TCWS computer-aided design models. In conclusion, the TCWS geometry models and neutron source definitions were incorporated into a baseline MCNP model of the Tokamak Complex.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water↗

Designing a Propylene-Glycol Coolant Servicer System for Gateway’s Internal Active Thermal Control System

A human spacecraft ATCS—especially one using single-phase coolant loops exposed to cabin atmospheric conditions—requires periodic degassing and refilling to support long-duration missions of 15 to 30 years. During initial fill operations, system maintenance, gas permeation, and quick-disconnect mating or de-mating, small amounts of gas can gradually enter the coolant system over time. This can lead to degraded heat transfer performance, pump cavitation, and potentially pump vapor lock if a significant gas volume accumulates over time. Additionally, system leaks and routine fluid sampling can gradually reduce accumulator volumes to unacceptable levels, requiring periodic refills. In more severe cases, catastrophic changes in fluid composition may necessitate emergency draining, refilling, and degassing to ensure continued system functionality. These risks were identified and mitigated on the ISS ITCS through the development of a dual-membrane degasser ORU and a Fluid Servicer System ORU for coolant refilling. These systems were developed for the fully water-based ISS ITCS Coolant[1]. The Gateway space station, the first permanent human habitat in lunar orbit, uses a propylene-glycol/water coolant mixture, which has significantly different fluid properties compared to pure water. Because microgravity degassing technologies are sensitive to fluid surface tension and viscosity, existing ISS hardware is not suitable for servicing a propylene-glycol-based TCS. Unlike the ISS, the Gateway will operate in a higher-radiation environment and must meet stricter mass constraints due to its location outside of low earth orbit. This Government Furnished Equipment (GFE) flight hardware project aims to develop a lightweight, radiation-resistant Coolant Servicer System (CSS) capable of degassing and refilling Gateway’s propylene-glycol water-based IATCS.

Propylene Glycol Water↗

Optimal Synthesis of a Pulverized Coal Power Plant with Carbon Capture

Coal constitutes an important source of fuel for the production of power in the United States. For instance, in January 2009, pulverized coal (PC) power plants alone contributed to over 45 percent of the Nation's total electric power production. However, PC power plants also contribute to increased emissions of greenhouse gases principally carbon-dioxide (CO2). Recently, various carbon capture strategies have been under active investigation so as to make these plants compete with the more environmental friendly renewable energy sources. One such technology that has received considerable success is the capture of CO2 by an amine-based solvent extraction process. However, an aqueous absorption/stripping technology when used in a PC power plant can reduce the net power output of the plant by as much as 20-40%. The energy penalty comes from heating up the solvent in the regenerator, balancing the enthalpy of reaction, and water stripping. This energy penalty poses considerable limitations on commercial viability of the solvent extraction process and, as a result, various energy-saving modifications have been proposed in the literature ranging from the use of hybrid solvents to novel stripper configurations. In this paper, we show that the energy penalty can be further reduced by heat integration of various PC plant components with the carbon capture system. In addition to the release of greenhouse gases to the environment, PC plants also consume a large amount of freshwater. It is estimated that subcritical and supercritical PC plants have water losses of 714 gal/MWh and 639 gal/MWh, respectively. Water loss is based on an overall balance of the plant source and exit streams. This includes coal moisture, air humidity, process makeup, cooling tower makeup (equivalent to evaporation plus blowdown), process losses (including losses through reactions, solids entrainment, and process makeup/blowdown) and flue gas losses. The primary source of water used in PC power plants is the closed-loop steam-based (Rankine) power cycles. These plants need to condense large quantities of low-pressure steam back to water so that it can be reused to produce high pressure steam. However, this requires the removal of large quantities of heat from the low pressure steam in the condensation process. This is usually done by transferring the heat to cooling water, which in turn transfers this heat to the environment by evaporation to the atmosphere. Also, the inclusion of a carbon capture process can increase the raw water usage by as much as 95 percent. In this work, we use heat exchanger network synthesis followed by an optimization approach to process synthesis for developing strategies for reducing water use in a supercritical PC power plant with a carbon capture and compression system. Uncertainties associated with dry bulb temperature, relative humidity, and demand will also be considered in this analysis.

01 COAL, LIGNITE, AND PEAT↗

Operations of a Radioisotope-based Propulsion System Enabling CubeSat Exploration of the Outer Planets

Exploration to the outer planets is an ongoing endeavor but in the current economical environment, cost reduction is the forefront of all concern. The success of small satellites such as CubeSats launched to Near-Earth Orbit has lead to examine their potential use to achieve cheaper science for deep space applications. However, to achieve lower cost missions; hardware, launch and operations costs must be minimized. Additionally, as we push towards smaller exploration beds with relative limited power sources, allowing for adequate communication back to Earth is imperative. Researchers at the Center for Space Nuclear Research are developing the potential of utilizing an advanced, radioisotope-based system. This system will be capable of providing both the propulsion power needed to reach the destination and the additional requirements needed to maintain communication while at location. Presented here are a basic trajectory analysis, communication link budget and concept of operations of a dual-mode (thermal and electric) radioisotope-based propulsion system, for a proposed mission to Enceladus (Saturnian icy moon) using a 6U CubeSat payload. The radioisotope system being proposed will be the integration of three sub-systems working together to achieve the overall mission. At the core of the system, stored thermal energy from radioisotope decay is transferred to a passing propellant to achieve high thrust – useful for quick orbital maneuvering. An auxiliary closed-loop Brayton cycle can be operated in parallel to the thrusting mode to provide short bursts of high power for high data-rate communications back to Earth. Additionally, a thermal photovoltaic (TPV) energy conversion system will use radiation heat losses from the core. This in turn can provide the electrical energy needed to utilize the efficiency of ion propulsion to achieve quick interplanetary transit times. The intelligent operation to handle all functions of this system under optimized conditions adds to the complexity of the mission architecture.

33 ADVANCED PROPULSION SYSTEMS↗

Novel Magnetically Fluidized Bed Reactor Development for the Looping Process: Coal to Hydrogen Production R&D

The coal to hydrogen project utilizes the iron/iron oxide looping process to produce high purity hydrogen. The input energy for the process is provided by syngas coming from gasification process of coal. The reaction pathways for this process have been studied and favorable conditions for energy efficient operation have been identified. The Magnetically Stabilized Porous Structure (MSPS) is invented. It is fabricated from iron and silica particles and its repeatable high performance has been demonstrated through many experiments under various conditions in thermogravimetric analyzer, a lab-scale reactor, and a large scale reactor. The chemical reaction kinetics for both oxidation and reduction steps has been investigated thoroughly inside MSPS as well as on the surface of very smooth iron rod. Hydrogen, CO, and syngas have been tested individually as the reducing agent in reduction step and their performance is compared. Syngas is found to be the most pragmatic reducing agent for the two-step water splitting process. The transport properties of MSPS including porosity, permeability, and effective thermal conductivity are determined based on high resolution 3D CT x-ray images obtained at Argonne National Laboratory and pore-level simulations using a lattice Boltzmann Equation (LBE)-based mesoscopic model developed during this investigation. The results of those measurements and simulations provide necessary inputs to the development of a reliable volume-averaging-based continuum model that is used to simulate the dynamics of the redox process in MSPS. Extensive efforts have been devoted to simulate the redox process in MSPS by developing a continuum model consist of various modules for conductive and radiative heat transfer, fluid flow, species transport, and reaction kinetics. Both the Lagrangian and Eulerian approaches for species transport of chemically reacting flow in porous media have been investigated and verified numerically. Both approaches lead to correct prediction of hydrogen production rates over a large range of experimental conditions in the laboratory scale reactor and the bench-scale reactor. In the economic analysis, a comparison of the hydrogen production plants using iron/iron oxide looping cycle and the conventional process has been presented. Plant configurations are developed for the iron/iron oxide looping cycle. The study suggests a higher electric power generation but a lower hydrogen production efficiency comparing with the conventional process. Additionally, it was shown that the price of H 2 obtained from our reactor can be as low as $\$$1.7/kg, which is 22% lower than the current price of the H 2 obtained from reforming plants.

01 COAL, LIGNITE, AND PEAT↗

Cell module and fuel conditioner development

The design features and plans for fabrication of Stacks 564 and 800 are described. The results of the OS/IES loop testing of Stack 562, endurance testing of Stack 560 and the post test analysis of Stack 561 are reported. Progress on construction and modification of the fuel cell test facilities and the 10 kW reformer test station is described. Efforts to develop the technical data base for the fuel conditioning system included vendor contacts, packed bed heat transfer tests, development of the BOLTAR computer program, and work on the detailed design of the 10 kW reformer are described.

Hoover, D. Q., Jr.↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

Thermal Vacuum Testing of a Novel Loop Heat Pipe Design for the Swift BAT Instrument

An advanced thermal control system for the Burst Alert Telescope on the Swift satellite has been designed and an engineering test unit (ETU) has been built and tested in a thermal vacuum chamber. The ETU assembly consists of a propylene loop heat pipe, two constant conductance heat pipes, a variable conductance heat pipe (VCHP), which is used for rough temperature control of the system, and a radiator. The entire assembly was tested in a thermal vacuum chamber at NASA/GSFC in early 2002. Tests were performed with thermal mass to represent the instrument and with electrical resistance heaters providing the heat to be transferred. Start-up and heat transfer of over 300 W was demonstrated with both steady and variable condenser sink temperatures. Radiator sink temperatures ranged from a high of approximately 273 K, to a low of approximately 83 K, and the system was held at a constant operating temperature of 278 K throughout most of the testing. A novel LHP temperature control methodology using both temperature-controlled electrical resistance heaters and a small VCHP was demonstrated. This paper describes the system and the tests performed and includes a discussion of the test results.

Ottenstein, Laura↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Modeling and Simulation of the ITER First Wall/Blanket Primary Heat Transfer System

ITER inductive power operation is modeled and simulated using a thermal-hydraulics system code (RELAP5) integrated with a 3-D CFD (SC-Tetra) code. The Primary Heat Transfer System (PHTS) functions are predicted together with the main parameters operational ranges. The control algorithm strategy and derivation are summarized as well. The First Wall and Blanket modules are the primary components of PHTS, used to remove the major part of the thermal heat from the plasma. The modules represent a set of flow channels in solid metal structure that serve to absorb the radiation heat and nuclear heating from the fusion reactions and to provide shield for the vacuum vessel. The blanket modules are water cooled. The cooling is forced convective with constant blanket inlet temperature and mass flow rate. Three independent water loops supply coolant to the three blanket sectors. The main equipment of each loop consists of a pump, a steam pressurizer and a heat exchanger. A major feature of ITER is the pulsed operation. The plasma does not burn continuously, but on intervals with large periods of no power between them. This specific feature causes design challenges to accommodate the thermal expansion of the coolant during the pulse period and requires active temperature control to maintain a constant blanket inlet temperature.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SIMULATION OF FLUX EMERGENCE FROM THE CONVECTION ZONE TO THE CORONA

Here, we present numerical simulations of magnetic flux buoyantly rising from a granular convection zone into the low corona. We study the complex interaction of the magnetic field with the turbulent plasma. The model includes the radiative loss terms, non-ideal equations of state, and empirical corona heating. We find that the convection plays a crucial role in shaping the morphology and evolution of the emerging structure. The emergence of magnetic fields can disrupt the convection pattern as the field strength increases, and form an ephemeral region-like structure, while weak magnetic flux emerges and quickly becomes concentrated in the intergranular lanes, i.e., downflow regions. As the flux rises, a coherent shear pattern in the low corona is observed in the simulation. In the photosphere, both magnetic shearing and velocity shearing occur at a very sharp polarity inversion line. In a case of U-loop magnetic field structure, the field above the surface is highly sheared while below it is relaxed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental and theoretical studies of capillary-pumped loop heat pipes

An experimental investigation of capillary-pumped loop (CPL) head pipes with single and multiple evaporators designed to develop and validate a computer model to predict the performance of CPL heat pipes over a wide range of conditions is discussed. The results of a literature search and review and a numerical study to determine the effects of geometric design parameters on the CPL heat pipe pressure drop and heat transfer characteristics are described. Vapor groove geometry and the use of circular versus rectangular evaporators were studied.

Obot, N. T.↗

An experimental study on the performance of closed loop pulsating heat pipe (CLPHP) with methanol as a working fluid

Thermal control is an important topic for thermal management of small electrical and electronic devices. Closed loop pulsating heat pipe (CLPHP) arises as the best solution for thermal control. The aim of this experimental study is to search a CLPHP of better thermal performance for cooling different electrical and electronic devices. In this experiment, methanol is used as working fluid. The effect of using methanol as a working fluid is studied on thermal performance in different filling ratios and angles of inclination. A copper capillary tube is used where the inner diameter is 2 mm,outer diameter is 2.5 mm and 250 mm long. The CLPHP has 8 loops where the evaporation section is 50 mm, adiabatic section is 120 mm and condensation section is 80 mm. The experiment is done using FR of 40%-70% with 10% of interval and angles of inclination 0° (vertical), 30°, 45°, 60° varying heat input. The results are compared on the basis of evaporator temperature, condenser temperature and their differences, thermal resistance, heat transfer co-efficient, power input and pulsating time. The results demonstrate the effect of methanol in different filling ratios and angles of inclination. M ethanol shows better performance at 30° inclination with 40% FR.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Inhibition of conductive heat flow by magnetic constriction in the corona and transition region - Dependence on the shape of the constriction

Attention is given to the process by which the shape of the constriction of field lines inhibiting the conduction of heat down from the corona acts in conjunction with the degree of constriction to inhibit the heat flow. The analytical model for the heat flow involves tapered flux tubes in which the plasma properties are constant on cross sections, while the plasma is static and the only energy transfer is by thermal conduction. It is determined that only two specific solutions to the model are applicable to the solar atmosphere: the steady state, which is appropriate for quiet regions and for active ones that are not flaring, and the time-dependent case, in which no heat enters the hot end, which is appropriate for conductive cooling of flare loops.

Moore, R. L.↗

High Performance Mars Liquid Cooling and Ventilation Garment Project

EVA space suit mobility in micro-gravity is enough of a challenge and in the gravity of Mars, improvements in mobility will enable the suited crew member to efficiently complete EVA objectives. The idea proposed is to improve thermal efficiencies of the liquid cooling and ventilation garment (LCVG) in the torso area in order to free up the arms and legs by removing the liquid tubes currently used in the ISS EVA suit in the limbs. By using shaped water tubes that greatly increase the contact area with the skin in the torso region of the body, the heat transfer efficiency can be increased to provide the entire liquid cooling requirement and increase mobility by freeing up the arms and legs. Additional potential benefits of this approach include reduced LCVG mass, enhanced evaporation cooling, increased comfort during Mars EVA tasks, and easing of the overly dry condition in the helmet associated with the Advanced Extravehicular Mobility Unit (EMU) ventilation loop currently under development.

Terrier, Douglas↗

Development of Enabling Technologies for Chemical Looping Combustion and Chemical Looping with Oxygen Uncoupling (Final Report)

This report summarizes results from the project, “Development of Enabling Technologies for Chemical Looping Combustion and Chemical Looping with Oxygen Uncoupling,” which evaluated several aspects of dual fluidized bed chemical looping combustion and chemical looping with oxygen uncoupling (CLOU). The objective was to provide tools and enabling technologies to help advance fluidized bed chemical looping technology to pilot, demonstration and commercial scale. One focus area is oxygen carriers, which are key to chemical looping combustion. The copper oxygen carrier-coal ash system was systematically evaluated through a combination of thermodynamic modeling and lab-scale experiments, taking into consideration different oxygen carrier support materials and coal types. A method of mapping “safe” and “risk” zones for different combinations was established, and recommendations for target conditions are provided. In addition, a simple solution for limiting negative influence of some coal ashes, namely adding small amounts of calcium to the system, is proposed. In addition, a novel process for recovering and recycling copper from spent oxygen carriers is proposed. A new approach for design and operation of loop seals in a CLOU system was developed, and involves distinct gas injection points and a short horizontal section to help control the fate of the fluidizing gases. For the air-to-fuel reactor loop seal, the upstream side is fluidized with air, ideally input into the side rather than into the bottom, which prevents uncoupling (reduction) of the oxygen carrier before entering the fuel reactor. Also, alternative for separating oxygen carrier particles and gas in circulating fluidized bed-based chemical looping system is proposed. A new reduced reaction scheme for conversion of coal in copper-based CLOU was developed and implemented into CPFD Software’s Barracuda VR package. The resulting model provides higher fidelity than the baseline, especially when it comes to minor reactions that are part of the overall combustion environment. For in-reactor heat extraction, it was determined in this project that the best way to do that in a dual circulating fluidized-bed system is through heat exchange low in the air reactor. The air reactor is the hotter of the two and for a fast-fluidized circulating bed, the lower, more dense section has a higher heat transfer coefficient and offers more consistent particle-wall contact since it doesn’t have the splashing behavior the top of the bed does. It was determined that just the wall surface area in the lower quarter to third of the air reactor is sufficient to control temperatures in both reactors. Finally, consideration was given to a new concept for CLC, which involves a staged fuel reactor with a different type of oxygen carrier in each stage.

01 COAL, LIGNITE, AND PEAT↗

Harnessing the Digital Transformation for Development of Electrified Aircraft Propulsion Control Systems

Hybrid electric aircraft propulsion is an emerging technology that presents a variety of potential benefits along with technical integration challenges. Developing these new propulsion architectures with their complex control systems, and ultimately proving their benefit, is a multistep process that goes from concept, to analysis, to dynamic simulation, to hardware in the loop testing, to full scale testing and beyond. This effort is being revolutionized and indeed enabled by new digital tools that support the increasing technology readiness level throughout the maturation process. NASA has developed and made available a suite of digital tools that ease the path from concept to implementation. The three packages are the Toolbox for the Modeling and Analysis of Thermodynamic Systems (T-MATS), the Electrical Modeling and Thermal Analysis Toolbox (EMTAT), and the Thermal Systems Analysis Toolbox (TSAT). These tools are interactive, complementary, and compatible with each other. T-MATS is a modular thermodynamic modeling framework designed for creating custom component level models of jet engines. EMTAT is a modeling framework used to simulate a variety of power electronic devices, using both physics-based and power flow calculations. TSAT is a framework for modeling and analysis of dynamic heat transfer. These packages all consist of graphical, drag-and-drop, parameterizable building blocks representing various components of the system to be modeled, e.g., compressors, turbines, motors, energy storage devices, etc. They are designed to enable the user to model and simulate the end-to-end dynamic operation of a hybrid powertrain at the timescale of the turbomachinery, capturing mechanical, electrical, and thermal interactions. This paper will describe through multiple examples how these tools have been used successfully in several of the early stages of hybrid electric propulsion system development, from the initial system modeling to real-time interactive pilot-in-the-loop simulation to physical hardware-in-the-loop testing, each step bringing the technology closer to fruition.

Hybrid electric propulsion↗