Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “emission control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Machine Learning for Real-time Fusion Plasma Behavior Prediction and Manipulation (Final Report)

The goal of this project is to implement real-time analysis of 2D Beam Emission Spectroscopy (BES) data to predict and control transient and high-bandwidth events at DIII-D. In essence, we wish to bring high-bandwidth fluctuation diagnostics into the realm of real-time measurements and control. The BES ML models will necessarily be deep neural networks (DNN) with a “data flow” architecture for compatibility with high-throughput, low-latency evaluation on a field-programmable gate array (FPGA) or other emerging processor technologies. The real-time output will be fed to the plasma control system (PCS) for real-time control tasks, specifically for ELM control and avoidance and for QH-mode access and sustainment. We anticipate that the real-time analysis of fluctuation diagnostics will create new enabling technologies to predict and control transient events such as confinement mode transitions, edge-localized modes, Alfven eigenmode events, and disruptions. The proposed research is aligned with ITER research needs and DIII-D programmatic goals. For instance, the prediction and avoidance of ELM events is critical for ITER machine safety. Also, H-mode access with RMP ELM suppression in ITER is an active research area due to high separatrix density, narrow SOL width, and elevated LH transition power threshold.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Advanced Sensors & Controls FWP Overview

Fossil energy power generation is needed now and in the future, but its role is shifting from baseload operation to fulfilling dispatchable power needs in regions of the United States. Novel sensors and controls will help to increase efficiency, minimize emissions, and reduce operating costs of existing power generation technologies under this increased load following role; and help enable next generation power systems with high efficiency and greater operational flexibility.<br>

Buric, Michael↗

Application of Heat Transfer Enhancement (HTE) System for Improved Efficiency of Power Plant Condensers

The mission of the National Energy Technology Laboratory (NETL), a U.S. laboratory under the Department of Energy, is to drive innovation and deliver solutions for an environmentally sustainable and prosperous energy future. Through the U.S. Department of Energy (DOE)/Fossil Energy’s (FE) Crosscutting Research Program, NETL funded Interphase Materials to develop and demonstrate a technology to improve power plant condenser efficiency. From 2018 through 2021, Interphase Materials developed THERMOPHASE, an advanced material applied to the condenser during plant operation to increase efficiency and lower fuel consumption, CO 2 emissions, and water withdrawal. THERMOPHASE was evaluated in controlled environments where improvements to heat transfer and a reduction in fouling were observed. THERMOPHASE was also applied to the main condenser of the Longview Power plant and changes to the plant performance were monitored. After two years following application of THERMOPHASE, a reduction in condenser back pressure of 0.26 ± 0.13 inHg was observed resulting in an estimated $3.35M in fuel savings, 136 million lbs. of decreased CO 2 emissions, and 1,287 million gallons reduced water withdrawal.

01 COAL, LIGNITE, AND PEAT↗

The role of chalcogen vacancies for atomic defect emission in MoS 2

For two-dimensional (2D) layered semiconductors, control over atomic defects and understanding of their electronic and optical functionality represent major challenges towards developing a mature semiconductor technology using such materials. Here, we correlate generation, optical spectroscopy, atomic resolution imaging, and ab initio theory of chalcogen vacancies in monolayer MoS 2 . Chalcogen vacancies are selectively generated by in-vacuo annealing, but also focused ion beam exposure. The defect generation rate, atomic imaging and the optical signatures support this claim. We discriminate the narrow linewidth photoluminescence signatures of vacancies, resulting predominantly from localized defect orbitals, from broad luminescence features in the same spectral range, resulting from adsorbates. Vacancies can be patterned with a precision below 10 nm by ion beams, show single photon emission, and open the possibility for advanced defect engineering of 2D semiconductors at the ultimate scale.

36 MATERIALS SCIENCE↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

14 SOLAR ENERGY↗

Spatially Adaptive Tunable Lighting Control System with Expanded Wellness and Energy Saving Benefits

Lighting design is becoming increasingly complex, including active dimming for energy savings and spectral tuning for human wellbeing. Modern commercial lighting control systems are already difficult to use, and maintain, and even with so-called Smart Lighting, optimizing light settings is rapidly exceeding the capabilities of direct human control, limiting the adoption of lighting control systems. The growing importance of Occupancy Centric Controls (OCC) for advanced building management systems can be applied to the development of autonomous lighting system controls needed to drive the adoption of advanced lighting controls for improved adaptive “sculpted illumination” for both greater energy savings and broader human wellbeing perspectives. This project, led by Rensselaer Polytechnic Institute, entitled “Spatially adaptive tunable lighting control system with expanded wellness and energy saving benefits” will develop and test an entirely new platform for automated optimized lighting design and control that requires little or no human engagement, yet contours lighting profiles automatically to minimize lighting energy use. We call this approach to lighting control “dynamic light sculpting” since the right amount of illumination is automatically delivered to occupants in real time. Since the system uses new, privacy-preserving occupant position and pose detection technologies developed by Rensselaer for broad OCC building applications, the control system will analyze how to deliver the right amount of the right type of illumination only where and when it is needed based these OCC platforms. To create these powerful autonomous lighting control platforms, the project will integrate evolving augmented reality (AR) and virtual reality (VR) tools with sophisticated lighting and interior design toolkits to create interactive lighting design and control simulators. Using the quickly growing paradigm of digital twins, these tools will integrate light fixture properties, occupancy sensor data, interior design data, and lighting specifications to accurately visualize how various design concepts interact with simulated yet realistic human activities that occur in commercial office buildings of various types. These advanced digital twin design and simulation tools will be combined with a new class of digitally-programmable LED lighting fixtures that can dynamically change the spectral content and direction of light emission. When fully integrated, the new autonomous lighting control system will take all of the guesswork out of optimizing light quality while minimizing energy consumption. Digital twin tools will simplify the design, installation, commissioning, operation, and maintenance of future energy-efficient lighting systems. It should be possible to reduce lighting energy costs from 40% to 70% with OCC based dynamic light sculpting systems. The work will be led by the Center for Lighting Enabled Systems and Applications (LESA) and the Center for Architectural Science and Ecology (CASE), both at Renssealer Polytechnic Institute; Lumileds, a global leader in the development of advanced LED systems; and HKS, a leading global architecture design firm. This interdisciplinary project team’s experience includes all of the design simulation tools, VR/AR digital twin visualization technology, advanced occupancy sensing technology, and complex control system design capabilities that will revolutionize lighting design and control technology to autonomously deliver high-quality lighting that improves human health and wellbeing while simultaneously maximizing lighting energy savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel estimation of aerosol processes with particle size distribution measurements: a case study with the TOMAS algorithm v1.0.0

Atmospheric aerosol microphysical processes are a significant source of uncertainty in predicting climate change. Specifically, aerosol nucleation, emissions, and growth rates, which are simulated in chemical transport models to predict the particle size distribution, are not understood well. However, long-term size distribution measurements made at several ground-based sites across Europe implicitly contain information about the processes that created those size distributions. This work aims to extract that information by developing and applying an inverse technique to constrain aerosol emissions as well as nucleation and growth rates based on hourly size distribution measurements. We developed an inverse method based upon process control theory into an online estimation technique to scale aerosol nucleation, emissions, and growth so that the model–measurement bias in three measured aerosol properties exponentially decays. The properties, which are calculated from the measured and predicted size distributions, used to constrain aerosol nucleation, emission, and growth rates are the number of particles with a diameter between 3 and 6 nm, the number with a diameter greater than 10 nm, and the total dry volume of aerosol ( N 3–6 , N 10 , V dry ), respectively. In this paper, we focus on developing and applying the estimation methodology in a zero-dimensional “box” model as a proof of concept before applying it to a three-dimensional simulation in subsequent work. The methodology is first tested on a dataset of synthetic and perfect measurements that span diverse environments in which the true particle emissions, growth, and nucleation rates are known. The inverse technique accurately estimates the aerosol microphysical process rates with an average and maximum error of 2 % and 13 %, respectively. Next, we investigate the effect that measurement noise has on the estimated rates. The method is robust to typical instrument noise in the aerosol properties as there is a negligible increase in the bias of the estimated process rates. Finally, the methodology is applied to long-term datasets of in situ size distribution measurements in western Europe from May 2006 through June 2007. At Melpitz, Germany, and Hyytiälä, Finland, the average diurnal profiles of estimated 3 nm particle formation rates are reasonable, having peaks near noon local time with average peak values of 1 and 0.15 cm –3 s –1 , respectively. The normalized absolute error in estimated N 3–6 , N 10 , and V dry at three European measurement sites is less than 15 %, showing that the estimation framework developed here has potential to decrease model–measurement bias while constraining uncertain aerosol microphysical processes.

54 ENVIRONMENTAL SCIENCES↗

A CHIL Validation of Machine Learning-Assisted Methods for Real-Time Controls of Solar PV for Grid Services: Preprint

Recent research has highlighted the potential for solar to act as a zero-marginal-cost and zero-emission flexibility resource on the bulk power system when operated with advanced control systems. To increase the performance of these systems, leading technologies, including machine learning (ML) and hierarchical inverter set point allocation, have been proposed; however, these technologies lack comprehensive validation under real-world application scenarios. This paper addresses this gap by designing and developing a controller-hardware-in-the-loop framework to evaluate the performance of different flexible solar technologies in responding to automatic generation control signals in a closed-loop fashion. Simulation results indicate the superior performance of an ML-based approach compared to the conventional reference-control grouping-based approach, showcasing its potential to support grid stability and operational efficiency.

closed-loop validation↗

Evaluation of Minimum NOx Emission From Ammonia Combustion

Abstract Ammonia (NH3) is being explored as a hydrogen carrier with no carbon emissions. However, if burned directly as NH3, rather than being completely decomposed back to N2/H2, the fuel-bound nitrogen comes with a potentially significant NOx emissions penalty. Indeed, several existing studies are showing ammonia combustion NOx emissions that exceed current natural gas fueled, DLN technologies by one to two orders of magnitude. Therefore, it is important to establish the theoretical minimum NOx emissions for an ammonia combustor, to determine how much NOx levels can be reduced via further technology development. In other words, the purpose of this work is not to analyze the performance of a specific combustor but, rather, the fundamental limits of what is achievable. This study quantifies this minimum NOx level for a two-stage combustor system for a given combustor exit temperature and residence time, with a constraint on unburned fuel levels. As expected, the optimum configuration is a rich front end combustor to burn and crack ammonia with significant H2 production, followed by an NO relaxation reactor, followed by a lean stage that consumes the remaining H2. The optimum residence time and stoichiometry of each zone are determined in the fast mixing limit, which essentially balances between NOx production in the primary and secondary zones. These results show minimum NOx levels are in 200–400 ppm range at 1 bar, but drop to levels of ∼25 ppm at 20 bar. These NOx emissions are dominated by NOx production in the primary stage which relaxes to equilibrium levels quite slowly. As processes controlling NOx relaxation to equilibrium in the primary stage dominate overall NO emission levels, combustor NOx sensitivities are essentially opposite that of natural gas fired, DLN systems. Specifically, NOx values drop with increased combustor residence time, increased pressure, and increased combustor exit temperature. These results also suggest that the most important strategy for NOx minimization is to provide sufficient relaxation time after the primary zone for NOx to approach equilibrium—this can be done via kinetic means to accelerate this relaxation rate, such as enhancing pressure or temperature, or increasing residence times. Indeed, this work shows that low pressure combustors specifically optimized for ammonia will have residence times that are one to two orders of magnitude larger than current natural gas systems. By doing so, NOx levels below 10 ppm may be achievable. Finally, we discuss the sensitivity of these values to uncertainties in ammonia kinetics.

Engineering↗

Quantitative agreement between dynamical rocking curves in ultrafast electron diffraction for x-ray lasers

Electron diffraction through a thin patterned silicon membrane can be used to create complex spatial modulations in electron distributions. By precisely varying parameters such as crystallographic orientation and wafer thickness, the intensity of reflections in the diffraction plane can be controlled and by placing an aperture to block all but one spot, we can form an image with different parts of the patterned membrane, as is done for bright-field imaging in microscopy. The patterned electron beams can then be used to control phase and amplitude of subsequent x-ray emission, enabling novel coherent x-ray methods. Furthermore, the electrons themselves can also be used for femtosecond time resolved diffraction and microscopy. As a first step toward patterned beams, we demonstrate experimentally and through simulation the ability to accurately predict and control diffraction spot intensities. We simulate MeV transmission electron diffraction patterns using the multislice method for various crystallographic orientations of a single crystal Si(001) membrane near beam normal. The resulting intensity maps of the Bragg reflections are compared to experimental results obtained at the Accelerator Structure Test Area Ultrafast Electron Diffraction (ASTA UED) facility at SLAC. Furthermore, the fraction of inelastic and elastic scattering of the initial charge is estimated along with the absorption of the membrane to determine the contrast that would be seen in a patterned version of the Si(001) membrane.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prevention of Dual-Mode Excitation in 9-Cell Cavities for LCLSII-HE

Dual-Mode Excitation, also referred to as mode-mixing, is a superposition of two fundamental pi modes in an SRF cavity. In 9-cell TESLA cavities used for the LCLSII-HE project, the two modes that are commonly excited are the pi mode (1300.2 MHz), and the 7/9 pi mode (1297.8 MHz). During vertical cavity qualification testing, only the pi mode is driven by the RF system. However, at high gradients, emitted power at the frequency of the 7/9 pi mode grows despite the RF system only powering the pi mode. When this happens, the RF power measurement system is unable to differentiate between the superimposed modes, and any data taken is invalid. The previous method of dealing with mode-mixing was to turn off power to the cavity, let both modes decay fully, then restore power. Because of the time-sensitive nature of this testing, this leads to underestimates of Q0 or any radiant field emission present in the cavity. The novel RF control solution prevents the 7/9 pi mode from being excited while not interfering with measurements of the fundamental pi mode. A second RF control system is connected to the cavity which drives the 7/9 pi mode. The loop phase for driving the 7/9 pi mode in self excited loop mode is determined then shifted by 180 degrees, thus providing a negative feedback to the undesired mode. Because this off-resonance power can be very small, on the order of milliwatts, it does not interfere with the high-power measurements of the fundamental pi mode. At Jefferson Lab, we are now able to test a cavity for the LCLSII-HE project with no problems from mode-mixing, which allows for CW processing of high-gradient multipacting and field emission.

Owen, Peter↗

Inverse reinforcement learning control for building energy management

Reinforcement learning (RL) based control is widely considered a promising approach in building automation and control as it has demonstrated the potential to deal with complex objectives in adjacent domains like robotics, autonomous vehicles, gaming applications, and advertisement recommendations. When applied to any environment, model-free RL learns to improve its control performance over time without requiring a control model, by receiving and then analyzing feedback from the building environment after each control action. Operational objectives are becoming increasingly complex through the simultaneous consideration of thermal comfort, carbon emissions, grid services, and indoor air quality. In this context, conventional rule-based control approaches are proving sub-optimal, mostly heuristic, and inadequate. The model-free and self learning nature of RL appears promising and attractive as it may address the scalability issues associated with advanced control approaches. However, it suffers from long training times and unstable control behavior during the early stages of its learning process, which makes it unsuitable to be applied directly to buildings. This paper addresses these issues using an inverse reinforcement learning approach (IRL), a technique utilized to learn the objective of a controller agent which is considered an expert in its respective domain. Here, we consider a rule-based control as the expert demonstrator. IRL is different from a direct imitation (i.e., direct mapping of states to actions) of control actions as it tries to find the underlying intent of an expert's policy, providing the controller with a better-generalized policy for unseen states or environments with slightly different dynamics. This approach propels the RL controller's policy to levels similar to or better than that of a rule-based policy before it starts learning by interacting with the building. This makes RL for building energy management applications more practical as it prevents the erratic and exploratory behavior in the initial training period, simultaneously speeding up the learning process when compared to applying an untrained RL agent directly to a building environment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Smart Ventilation Controls for Occupancy and Auxiliary Fan Use Across U.S. Climates

Smart Ventilation has been developed as a way to reduce the energy associated with ventilation by changing when ventilation happens and how much ventilation occurs at any given time. In high performance buildings with low envelope and appliance related loads, ventilation is becoming a bigger part of the total building energy use and needs to be addressed if performance targets are to be met. This work explores the development and performance of smart ventilation controls based on occupancy and auxiliary fan operation that provide annual dwelling unit ventilation equivalence to ASHRAE Standard 62.2-2016. A prototype high performance home compliant with U.S. DOE Building America Zero Energy Ready program requirements was simulated using the REGCAP tool with and without smart controls across 15 U.S. DOE climate zones. Balanced and unbalanced IAQ fans were independently simulated, and all smart controlled fans had airflows double the reference 62.2-2016 airflow. Three idealized occupancy patterns were examined: 1st shift (a typical daily work/school absence), an extended 1st shift with more time spent out of the home evenings and weekends and 3rd shift (night work). The Occupancy controller turns the IAQ fan off during unoccupied periods, and it resumes ventilation upon their return. While unoccupied, contaminants are allowed to accumulate in the space, because occupants are not exposed to these contaminants. When occupants return home, they are exposed to these higher contaminant concentrations, and the controller increases the ventilation rate sufficiently to ensure equivalence with a continuous IAQ fan. Accounting for pollutant emissions that occur during unoccupied periods (as required by ASHRAE 62.2-2016), sharply distinguishes our occupancy controls from past Demand Controlled Ventilation systems. This new accounting method results in equivalent contaminant exposure, as well as lower reductions in average ventilation rates and lower energy savings. Smart controls were demonstrated that saved HVAC energy (i.e., avoided heating/cooling load, as well as fan energy)—averaging between 6 and 46% of ventilation-related energy use depending on the control strategy and occupancy pattern assumptions. The greatest savings were in the combined Auxiliary Fan + Occupancy control. Energy savings increased with climate heating demand and longer unoccupied time periods. The 3rd shift occupancy pattern had better performance, due to the thermal benefit of reducing the ventilation rate during the cold nighttime hours. This same effect provided a cooling energy benefit in hotter locations for the 1st shift. Overall, savings from occupancy-based smart controls were low, because of the recovery period required after occupants return home, during which the airflow is double the 62.2 reference. This recovery is required to maintain equivalence with the ASHRAE standard. Occupancy-based control performance was improved when combined with sensing auxiliary fans and when providing a pre-occupancy flush out of one- or two-hours. Performance was similarly improved if the ASHRAE Standard were to recognize that pollutant emissions are lower during unoccupied periods, iii allowing a lower target ventilation rate during unoccupied periods (not currently in the standard) (see Full vs. Half AEQ in this report). Finally, over-sized unbalanced fans that are cycled on-and-off by a smart controller (or timer) were found to substantially increase annual average air exchange and energy use relative to a continuous unbalanced fan due to the effects of superposition with natural infiltration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of a Co-Optimized, Smart Hybrid Heat Pump Control

This study examines a residential dual fuel (DF) heating system that integrates heat pump and gas furnace technology with a home’s forced-air distribution ducts. Specifically, it explores a retrofit where an “add-on” heat pump replaces the air conditioning (A/C) system and is combined with the home’s existing furnace and air handler. The research team developed and validated an innovative control scheme for this integrated DF system that selected the more economical heating source (furnace or heat pump) while maintaining comfort in the home. The project’s field study and subsequent modeling analysis show that this control scheme can decrease energy use, cost, and emissions compared to a furnace-only system. As homes in mixed and cold climates transition to more electric space heating, furnace-to-dual fuel system retrofits offer a solution that can alleviate the retrofit costs, energy cost concerns, and peak load impacts of full electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evolution and persistence of SiO emission in nanosecond laser ablation plumes

Analyzing laser-produced plasmas in a controlled oxygen-containing environment provides insight into the formation and evolution of molecular species through gas-phase oxidation. This study explores the role of ambient pressure and oxygen availability in forming SiO molecular species in laser ablation plumes. The self-emission emanating during the reactive ablation of Si targets was characterized by optical emission spectroscopy and optical time-of-flight techniques. Our results showed that the SiO species formation was greatly influenced by both the ambient pressure and oxygen availability. The intensity and the persistence of SiO emission bands are lower at higher oxygen concentrations, indicating they are depopulated by the formation of more complex silicon oxides. The oxygen partial pressure effects on plume chemistry showed that SiO formation is favored even with a minimal oxygen concentration in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ultrafast Dynamics of Plasmon-Coupled Excitons in Semiconducting Nanoplatelets

Exciton-plasmon coupling in nanomaterials produces many relevant phenomena for photonics applications including increased light-matter interactions, enhanced radiative rates of quantum emitters, and coherent energy exchange. In the case of exciton coupling to surface plasmon polaritons (SPPs), dispersive interactions controlled by the wavevector of optical excitation create the opportunity for tunable optical emission. Strong temporal impacts on exciton lifetimes can also occur in coupled systems, creating the opportunity for ultrafast control of exciton lifetime via changes in electronic coupling magnitude to a dispersive SPP. The coupling strength can be impacted by the morphology of the nanomaterials. Here, in this study, we utilize colloidal semiconductor nanoplatelets deposited onto thin silver plasmonic films, and compare the results to semiconductor quantum dots deposited on the silver films. We map the dispersion of the coupled systems and measure the ultrafast transient absorption response of the coupled systems. Due to the larger interaction areas of the nanoplatelets that lie flat on the silver films, a greater degree of coupling is found for the nanoplatelets, and much faster temporal responses are found as compared to quantum dots. Fresnel theory calculations that incorporate heavy and light hole features can reproduce the dispersion of the nanoplatelet-silver film, and a simple three-state model is developed to provide insights into the nature of the coupling at different photon energies along the dispersion curve.

colloidal semiconductor nanoplatelets↗

What controls the UV-to-X-ray continuum shape in quasars?

ABSTRACT We present an investigation of the interdependence of the optical-to-X-ray spectral slope (αox), the He ii equivalent-width (EW), and the monochromatic luminosity at 2500 Å (L2500). The values of αox and He ii EW are indicators of the strength/shape of the quasar ionizing continuum, from the ultraviolet (UV; 1500–2500 Å), through the extreme ultraviolet (EUV; 300–50 Å), to the X-ray (2 keV) regime. For this investigation, we measure the He ii EW of 206 radioquiet quasars devoid of broad absorption lines that have high-quality spectral observations of the UV and 2 keV X-rays. The sample spans wide redshift (≈0.13–3.5) and luminosity (log(L2500) ≈ 29.2–32.5 erg s−1 Hz−1) ranges. We recover the well-known αox–L2500 and He ii EW–L2500 anticorrelations, and we find a similarly strong correlation between αox and He ii EW, and thus the overall spectral shape from the UV, through the EUV, to the X-ray regime is largely set by luminosity. A significant αox– He ii EW correlation remains after removing the contribution of L2500 from each quantity, and thus the emission in the EUV and the X-rays are also directly tied. This set of relations is surprising, since the UV, EUV, and X-ray emission are expected to be formed in three physically distinct regions. Our results indicate the presence of a redshift-independent physical mechanism that couples the continuum emission from these three different regions, and thus controls the overall continuum shape from the UV to the X-ray regime.

Timlin III, John D.↗