Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronics analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Nuclear fuel behavior at high temperature: new insights from post-test examinations on the VERDON-1 sample

In order to reduce the uncertainties concerning Source Term assessment under Light Water Reactor (LWR) severe accident conditions, 4 VERDON tests were recently performed. They have been defined in the framework of the International Source Term Program and carried out at CEA Cadarache, in the LECA-STAR facility. Among these 4 VERDON tests, VERDON-1 test was devoted to high burn-up UO{sub 2} fuel behavior and FP release under H{sub 2} reducing conditions at very high temperature. This test was performed with the Release Circuit, which is devoted to the precise characterization of the FP release, in terms of FP release kinetics and fission products (FPs) released fraction. The main components of the circuits are a furnace heating the fuel sample, a filter trapping the emitted aerosols and gamma spectrometry detectors for online and post-test measurements. VERDON-1 test was conducted up to about 2600 Celsius degrees without reaching global fuel relocation, allowing thereby post-test micro-analyses. After a brief description of the fuel sample nature and the experimental set-up, we present the progress of the experimental sequence and the associated gamma spectrometry measurements. We then focus on the major results of the VERDON-1 tests regarding the fuel global behavior. These results are obtained by two complementary techniques. First, the fuel sight gamma station can be used either on-line to detect fuel relocation or just after the test, as a longitudinal bench, to get preliminary information on the global shape of the fuel sample inside the furnace. Secondly, these information are completed by post-test examinations performed on the fuel sample after extraction from the furnace. Complete qualitative and quantitative characterizations, including EPMA (Electron Probe Micro-Analysis) and SEM (Scanning Electron Microscopy) analysis, were performed for the first time at the CEA Cadarache on a sample that has been submitted to such severe accident conditions. These results show an advanced state of sample degradation, with locally previously molten areas, meaning that fuel global relocation was imminent by the end of thermal-hydraulic sequence. The relocation temperature is compared to that of previous VERCORS tests and discussed regarding the atmosphere of the test and possible UO{sub 2}-ZrO{sub 2} interaction. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Analysis of Mis-Steered Electron Beam in the NSLS-II Storage Ring

This note reports the analysis of the mis-steered electron in the NSLS-II storage ring for the determination of supplementary shielding. The potential angles and offsets of the mis-steered beam are calculated by implementing the cascaded parameter scan (CPS) along the beam-line. This method is originally developed for the top-off safety analysis, and has been well documented in ref. The basic idea of CPS is to combine the phase space images due to different magnet set-points into one superset, then re-populate virtual particles on a fine grid as the input of the downstream magnet scanning. The purpose of re-population in phase space is to avoid the redundant particle tracking calculation due to the multi-layer overlap of different magnet settings. A parallel python code of implementing the tracking study has been written, and benchmarked with other top-off safety simulators developed in SLAC and LBNL.

36 MATERIALS SCIENCE↗

Origin of the spin reorientation transitions in (Fe 1–x Co x ) 2 B alloys

Low-temperature measurements of the magnetocrystalline anisotropy energy K in (Fe 1–x Co x ) 2 B alloys are reported, and the origin of this anisotropy is elucidated using a first-principles electronic structure analysis. The calculated concentration dependence K(x) with a maximum near x = 0.3 and a minimum near x = 0.8 is in excellent agreement with experiment. This dependence is traced down to spin-orbital selection rules and the filling of electronic bands with increasing electronic concentration. In conclusion, at the optimal Co concentration, K depends strongly on the tetragonality and doubles under a modest 3% increase of the c/a ratio, suggesting that the magnetocrystalline anisotropy can be further enhanced using epitaxial or chemical strain.

36 MATERIALS SCIENCE↗

Structural analysis of Gd 6 FeBi 2 from single-crystal X-ray diffraction methods and electronic structure calculations

The crystal structure of the gadolinium iron bis­muthide Gd 6 FeBi 2 has been characterized by single-crystal X-ray diffraction data and analyzed in detail using first-principles calculations. The structure is isotypic with the Zr 6 CoAl 2 structure, which is a variant of the ZrNiAl structure and its binary prototype Fe 2 P (Pearson code hP 9, Wyckoff sequence g f d a ). As such, the structure is best viewed as an array of tricapped trigonal prisms of Gd atoms centered alternately by Fe and Bi. The magnetic-ordering temperature of this compound ( ca 350 K) is much higher than that of other rare-earth metal-rich phases with the same or related structures. It is also higher than the ordering temperature of many other Gd-rich ternary phases, where the magnetic exchange is typically governed by Ruderman–Kittel–Kasuya–Yosida (RKKY) inter­actions. First-principles calculations reveal a larger than expected Gd magnetic moment, with the additional contribution arising from the Gd 5 d electrons. The electronic structure analysis suggests strong Gd 5 d –Fe 3 d hybridization to be the cause of this effect, rather than weak inter­actions between Gd and Bi. These details are of importance for understanding the magnetic response and explaining the high ordering tem­per­ature in this material.

Chemistry↗

Ion-Electron Coupling-Driven Redox Behavior in Metal–Organic Frameworks

Redox-active metal–organic frameworks (MOFs) have long been proposed as electronic transport platforms, yet the microscopic origin of their conductivity remains debated. A theoretical demonstration reveals charge transport in a Zn(pyrazole–naphthalene diimide (NDI)) MOF arising not from delocalized band-like states but from redox hopping between discrete linker sites. Using ab initio molecular dynamics simulations combined with electronic structure analysis, we established a direct link among electron injection, structural reorganization, and transport. Electron accumulation proceeds sequentially and site-selectively from imide and carbonyl groups of the NDI core progressively involving pyrazole N atoms at higher reduction states, through a hierarchy of redox-active sites. In contrast, Zn nodes remain essentially redox-inactive, which confirms their structural role. Density-of-states analysis corroborates a transport regime dominated by linker-centered states with evolving p-character upon reduction, resulting in dynamically reconfigured conduction networks. Real-time trajectories reveal anisotropic linker-to-linker electron transfer modulated by counterion coordination. This cooperative ion–electron regime emerges from potential energy surface collapse into a single low-barrier transition (ΔG ‡ ≈ 45 meV), where ionic and electronic motions evolve adiabatically on the same free-energy landscape. Elucidating redox conductivity in Zn(pyrazole–NDI) MOFs provides a theoretical framework for use in neuromorphic computing and related technologies.

Charge transfer↗

Modern Material Analysis Instruments Add a New Dimension to Materials Characterization and Failure Analysis

Modern analytical tools can yield invaluable results during materials characterization and failure analysis. Scanning electron microscopes (SEMs) provide significant analytical capabilities, including angstrom-level resolution. These systems can be equipped with a silicon drift detector (SDD) for very fast yet precise analytical mapping of phases, as well as electron back-scattered diffraction (EBSD) units to map grain orientations, chambers that admit large samples, variable pressure for wet samples, and quantitative analysis software to examine phases. Advanced solid-state electronics have also improved surface and bulk analysis instruments: Secondary ion mass spectroscopy (SIMS) can quantitatively determine and map light elements such as hydrogen, lithium, and boron - with their isotopes. Its high sensitivity detects impurities at parts per billion (ppb) levels. X-ray photo-electron spectroscopy (XPS) can determine oxidation states of elements, as well as identifying polymers and measuring film thicknesses on coated composites. This technique is also known as electron spectroscopy for chemical analysis (ESCA). Scanning Auger electron spectroscopy (SAM) combines surface sensitivity, spatial lateral resolution (10 nm), and depth profiling capabilities to describe elemental compositions of near and below surface regions down to the chemical state of an atom.

Panda, Binayak↗

Interplay between bulk and edge-bound topological defects in a square micromagnet

A field-driven transformation of a domain pattern in a square micromagnet, defined in a thin film of La 0.7 Sr 0.3 MnO 3 , is discussed in terms of creation and annihilation of bulk vortices and edge-bound topological defects with half-integer winding numbers. The evolution of the domain pattern was mapped with soft x-ray photoemission electron microscopy and magnetic force microscopy. Micromagnetic modeling, permitting detailed analysis of the spin texture, accurately reproduces the measured domain state transformation. The simulations also helped stipulate the energy barriers associated with the creation and annihilation of the topological charges and thus to assess the stability of the domain states in this magnetic microstructure.

36 MATERIALS SCIENCE↗

Optical properties of metamorphic GaAs/InAlGaAs/InGaAs heterostructures with InAs/InGaAs quantum wells, emitting light in the 1250–1400-nm spectral range

It is demonstrated that metamorphic GaAs/InAlGaAs/InGaAs heterostructures with InAs/InGaAs quantum wells, which emit light in the 1250–1400 nm spectral range, can be fabricated by molecular-beam epitaxy. The structural and optical properties of the heterostructures are studied by X-ray diffraction analysis, transmission electron microscopy, and the photoluminescence method. Comparative analysis of the integrated photoluminescence intensity of the heterostructures and a reference sample confirm the high efficiency of radiative recombination in the heterostructures. It is confirmed by transmission electron microscopy that dislocations do not penetrate into the active region of the metamorphic heterostructures, where the radiative recombination of carriers occurs.

36 MATERIALS SCIENCE↗

Relation between sampling, sensitivity and precision in strain mapping using the Geometric Phase Analysis method in Scanning Transmission Electron Microscopy

The sensitivity and the precision of the Geometric Phase Analysis (GPA) method for strain characterization is a topic widely discussed in the literature and is usually difficult to quantify. Indeed, the GPA precision is intricately linked to the resolution of the strain maps defined when masking the periodic reflections in Fourier space. In this study an additional parameter, sampling, is proposed to be analyzed regarding the precision of GPA by developing the concept of a phase noise in the GPA equations. Both experimentally and theoretically, the following article demonstrates how the precision, and the sensitivity of the GPA method is improved when using a larger pixel spacing to record an electron micrograph in Scanning Transmission Electron Microscopy (STEM). In conclusion, the counterintuitive concept of increasing the field of view to improve the GPA precision results in an extension of the application of strain characterization methods in STEM towards low deformation levels.

47 OTHER INSTRUMENTATION↗

Crystal and electronic characterization of Nd{sub x}Ti{sub 1−x}BO{sub 2+d} semiconductors

Highlights: • Crystal and electronic structure properties of Nd{sub x}Ti{sub 1−x}BO{sub 2+d} structure were investigated. • New crystal structures for Nd–Ti complexes are determined. • Distortions in the crystal structure were observed as a result of Boron shortage. • Prominent change in electronic properties of the samples with the increasing Nd amount. - Abstract: Neodymium substituted TiBO{sub 3} samples were investigated according to their crystal, electric and electronic properties. Studies were conducted by X-ray absorption fine structure spectroscopy (XAFS) technique for the samples with different substitutions in the preparation processes. To achieve better crystal structure results during the study, XRD pattern results were supported by extended-XAFS (EXAFS) analysis. The electronic structure analysis were studied by X-ray absorption near-edge structure spectroscopy (XANES) measurements at the room temperatures. Due to the substituted Nd atoms, prominent changes in crystal structure, new crystal geometries for Nd-Ti complexes, phase transitions in the crystals structure were detected according to the increasing Nd substitutions in the samples. In the entire stages of the substitutions, Nd atoms were observed as governing the whole phenomena due to their dominant characteristics in Ti geometries. Besides, electrical resistivity decay was determined in the materials with the increasing amount of Nd substitution.

36 MATERIALS SCIENCE↗

Correlative electron and ion beam analysis of the electrochemical performances of LiV 3 O 8 cathode films as a function of microstructures

Degradation mechanisms in LiV 3 O 8 cathode films (~500 nm) with different initial microstructures i.e., globular nanocrystals in amorphous matrix and needle-like nanocrystals, synthesized by annealing the cathodes at 150 °C and 300 °C for 6 h are studied by Transmission Electron Microscopy (TEM) and Auger Electron Spectroscopy (AES). In addition, a unique in-situ combination of TEM and Secondary Ion Mass Spectrometry (SIMS) imaging techniques, namely Parallel Ion and Electron beam Spectrometry (PIES) is carried out to measure the 3D distribution of V and Li with nanoscale resolution. These characterization studies focus on correlating the pre- and post-cycling microstructure to observed electrochemical performance. The LiV 3 O 8 cathode film with needle-like nanocrystals (300 °C) shows a higher initial capacity but it degrades rapidly compared to the film with globular nanocrystals embedded in amorphous matrix (150 °C). We observed that LiV 3 O 8 films with needle-like nanocrystals are more susceptible to cathode decohesion and vanadium dissolution than the films with globular nanocrystals embedded in amorphous matrix, explaining the differences in their electrochemical performance. The findings from this study have relevance to the development of thin film electrode microstructures for high capacity and cyclic stability.

25 ENERGY STORAGE↗

Surface analysis of mixed-conducting ferrite membranes by the conversion-electron Moessbauer spectroscopy

Conversion-electron Moessbauer spectroscopy analysis of iron surface states in the dense ceramic membranes made of {sup 57}Fe-enriched SrFe{sub 0.7}Al{sub 0.3}O{sub 3-{delta}} perovskite, shows no traces of reductive decomposition or carbide formation in the interfacial layers after operation under air/CH{sub 4} gradient at 1173 K, within the limits of experimental uncertainty. The predominant trivalent state of iron cations at the membrane permeate-side surface exposed to flowing dry methane provides evidence of the kinetic stabilization mechanism, which is only possible due to slow oxygen-exchange kinetics and enables long-term operation of the ferrite-based ceramic reactors for natural gas conversion. At the membrane feed-side surface exposed to air, the fractions of Fe{sup 4+} and Fe{sup 3+} are close to those in the powder equilibrated at atmospheric oxygen pressure, suggesting that the exchange limitations to oxygen transport are essentially localized at the partially reduced surface. - Graphical Abstract: Conversion-electron Moessbauer spectroscopy analysis of dense ceramic membranes made of {sup 57}Fe-enriched SrFe{sub 0.7}Al{sub 0.3}O{sub 3-{delta}} perovskite, shows no reductive decomposition in thin interfacial layers after testing under air/CH{sub 4} gradient, enabling stable operation of the ferrite-based ceramic reactors for partial oxidation of methane. Highlights: > Conversion-electron Moessbauer spectroscopy is used for mixed-conducting membranes. > No decomposition is detected in the membrane surface layers under air/CH{sub 4} gradient. > Due to kinetic stabilization, Fe{sup 3+} states prevail at the surface exposed to methane. > Transmission Moessbauer spectra show perovskite decomposition on equlibration in CH{sub 4}. > Ferrite-based ceramic reactors can stably operate under air/CH{sub 4} gradient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects Of B On Intergranular Hot Cracking In Ni Alloys

Report describes experiments on role of boron on solidification of 718-type nickel/chromium/iron superalloys containing niobium and relative intergranular segregations of boron, sulfur, and phosphorus in alloys. Ten alloys studied by use of light and scanning electron microscopy (SEM), energy-dispersive x-ray analysis, transmission electron microscopy (TEM) with energy-dispersive analysis of thin-film specimens, mechanical tests for susceptibility to microfissuring, differential thermal analysis (DTA), scanning Auger microscopy, and Gleeble thermal analysis.

Thompson, Raymond G.↗

Universal signal scaling in microwave impedance microscopy

Microwave impedance microscopy (MIM) is an emerging scanning probe technique that measures the local complex dielectric function using near-field microwave. Although it has made significant impacts in diverse fields, a systematic, quantitative understanding of the signal's dependence on various important design parameters is lacking. Here, we show that for a wide range of MIM implementations, given a complex tip-sample admittance change ΔΥ, the MIM signal—the amplified change in the reflected microwave amplitude—is –G · ΔΥ/2Υ 0 · η 2 · V in , where η is the ratio of the microwave voltage at the probe to the incident microwave amplitude, Y o is the system admittance, and G is the total voltage gain. For linear circuits, η is determined by the circuit design and does not depend on V in . We show that the maximum achievable signal for different designs scales with η 2 or η when limited by input power or sample perturbation, respectively. Furthermore, this universal scaling provides guidance on diverse design goals, including maximizing narrow-band signal for imaging and balancing bandwidth and signal strength for spectroscopy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Highly anisotropic conductivity of tablets pressed from polyaniline-montmorillonite nanocomposite

Highlights: • Montmorillonite (MMT) can be intercalated with polyaniline (PANI) chains. • Tablets pressed from PANI/MMT exhibit high anisotropy in electrical conductivity. • Pressure 28MPa is sufficient to reach the anisotropy. • Tablets pressed from pure PANI also exhibit anisotropy in electrical conductivity. - Abstract: Polyaniline-montmorillonite nanocomposite was prepared from anilinium sulfate (precursor) and ammonium peroxodisulfate (oxidizing agent) using simple one-step method. The resulting nanocomposite obtained in powder form has been pressed into tablets using various compression pressures (28–400 MPa). Electrical conductivities of tablets in two perpendicular directions, i.e. direction parallel with the main surface of tablet (σ=) and in orthogonal direction (σ⊥), and corresponding anisotropy factors (i.e., the ratio σ=/σ⊥) have been studied in dependence on compression pressure used during the preparation. Polyaniline-montmorillonite nanocomposite was characterized using X-ray diffraction analysis, raman spectroscopy, transmission electron microscopy, thermogravimetric analysis and molecular modeling which led to the understanding of the internal structure. Measurement of hardness performed on pressed tablets has been also involved. Taking into account the highest value of anisotropy factor reached (σ=/σ⊥ = 490), present study shows a chance to design conductors with nearly two-dimensional conductivity.

36 MATERIALS SCIENCE↗

High temperature deformation of hot-pressed polycrystalline orthoenstatite

Artificial hot pressed polycrystalline samples were prepared from purified powder of Bamble, Norway, orthoenstatite, (Mg0.86Fe0.14)SiO3. The uniaxial creep behavior of the polycrystalline orthoenstatite was studied over stress ranges of 10-180 MPa and temperatures of 1500-1700 K (0.82-0.93 T sub m) under two different oxygen fugacities, namely equilibrium (Mo-MoO2 buffer) and a reducing (graphite heating element) atmosphere, respectively. An intergranular glassy phase of different compositions with a cavitational creep deformation were observed. In the Mo-MoO2 buffer atmosphere with PO2 approx. 10 to the minus 11 power - 10 to the minus 13 power atmospheres, the results of an analytical electron microscopy analysis indicate that the glassy phases are richer in Ca and Al due to the residual impurities after hot pressing. In the reducing atmosphere with an oxygen fugacity of PO2 approx. 10 to the minus 3 power - 10 to the minus 25 power atmospheres, the results of analytical electron microscopy analysis indicate that the glassy phase is almost pure silica with the presence of free iron precipitate on grain facets and at triple junctions due to the reduction of bulk materials.

Dehghan-Banadaki, A.↗

Microstructural, chemical and textural characterization of ZnO nanorods synthesized by aerosol assisted chemical vapor deposition

ZnO nanorods were synthesized by aerosol assisted chemical vapor deposition onto TiO{sub 2} covered borosilicate glass substrates. Deposition parameters were optimized and kept constant. Solely the effect of different nozzle velocities on the growth of ZnO nanorods was evaluated in order to develop a dense and uniform structure. The crystalline structure was characterized by conventional X-ray diffraction in grazing incidence and Bragg–Brentano configurations. In addition, two-dimensional grazing incidence synchrotron radiation diffraction was employed to determine the preferred growth direction of the nanorods. Morphology and growth characteristics analyzed by electron microscopy were correlated with diffraction outcomes. Chemical composition was established by X-ray photoelectron spectroscopy. X-ray diffraction results and X-ray photoelectron spectroscopy showed the presence of wurtzite ZnO and anatase TiO{sub 2} phases. Morphological changes noticed when the deposition velocity was lowered to the minimum, indicated the formation of relatively vertically oriented nanorods evenly distributed onto the TiO{sub 2} buffer film. By coupling two-dimensional X-ray diffraction and computational modeling with ANAELU it was proved that a successful texture determination was achieved and confirmed by scanning electron microscopy analysis. Texture analysis led to the conclusion of a preferred growth direction in [001] having a distribution width Ω = 20° ± 2°. - Highlights: • Uniform and pure single-crystal ZnO nanorods were obtained by AACVD technique. • Longitudinal and transversal axis parallel to the [001] and [110] directions, respectively. • Texture was determined by 2D synchrotron diffraction and electron microscopy analysis. • Nanorods have its [001] direction distributed close to the normal of the substrate. • Angular spread about the preferred orientation is 20° ± 2°.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Monte Carlo based beam model using a photon MLC for modulated electron radiotherapy

Purpose: Modulated electron radiotherapy (MERT) promises sparing of organs at risk for certain tumor sites. Any implementation of MERT treatment planning requires an accurate beam model. The aim of this work is the development of a beam model which reconstructs electron fields shaped using the Millennium photon multileaf collimator (MLC) (Varian Medical Systems, Inc., Palo Alto, CA) for a Varian linear accelerator (linac). Methods: This beam model is divided into an analytical part (two photon and two electron sources) and a Monte Carlo (MC) transport through the MLC. For dose calculation purposes the beam model has been coupled with a macro MC dose calculation algorithm. The commissioning process requires a set of measurements and precalculated MC input. The beam model has been commissioned at a source to surface distance of 70 cm for a Clinac 23EX (Varian Medical Systems, Inc., Palo Alto, CA) and a TrueBeam linac (Varian Medical Systems, Inc., Palo Alto, CA). For validation purposes, measured and calculated depth dose curves and dose profiles are compared for four different MLC shaped electron fields and all available energies. Furthermore, a measured two-dimensional dose distribution for patched segments consisting of three 18 MeV segments, three 12 MeV segments, and a 9 MeV segment is compared with corresponding dose calculations. Finally, measured and calculated two-dimensional dose distributions are compared for a circular segment encompassed with a C-shaped segment. Results: For 15 × 34, 5 × 5, and 2 × 2 cm{sup 2} fields differences between water phantom measurements and calculations using the beam model coupled with the macro MC dose calculation algorithm are generally within 2% of the maximal dose value or 2 mm distance to agreement (DTA) for all electron beam energies. For a more complex MLC pattern, differences between measurements and calculations are generally within 3% of the maximal dose value or 3 mm DTA for all electron beam energies. For the two-dimensional dose comparisons, the differences between calculations and measurements are generally within 2% of the maximal dose value or 2 mm DTA. Conclusions : The results of the dose comparisons suggest that the developed beam model is suitable to accurately reconstruct photon MLC shaped electron beams for a Clinac 23EX and a TrueBeam linac. Hence, in future work the beam model will be utilized to investigate the possibilities of MERT using the photon MLC to shape electron beams.

62 RADIOLOGY AND NUCLEAR MEDICINE↗