Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electron tubes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Barium-Dispenser Thermionic Cathode

Improved reservoir cathode serves as intense source of electrons required for high-frequency and often high-output-power, linear-beam tubes, for which long operating lifetime important consideration. High emission-current densities obtained through use of emitting surface of relatively-low effective work function and narrow work-function distribution, consisting of coat of W/Os deposited by sputtering. Lower operating temperatures and enhanced electron emission consequently possible.

Wintucky, Edwin G.↗

Development of a 75-watt 60-GHz traveling-wave tube for intersatellite communications

This program covers the initial design and development of a 75 watt, 60 GHz traveling-wave tube for intersatellite communications. The objective frequency band was 59 to 64 GHz, with a minimum tube gain of 35 dB. The objective overall efficiency at saturation was 40 percent. The tube, designated the 961H, used a coupled-cavity interaction circuit with periodic permanent magnet beam focusing to minimize the weight. For efficiency enhancement, it incorporated a four-stage depressed collector capable of radiation cooling in space. The electron gun had a low-temperature (type-M) cathode and an isolated anode. Two tubes were built and tested; one feasibility model with a single-stage collector and one experimental model that incorporated the multistage collector.

Rousseau, A. L.↗

Beam impingement angle effects on secondary electron emission characteristics of textured pyrolytic graphite

Experimentally determined values of true secondary electron emission and relative values of reflected primary electron yield for untreated and ion-textured pyrolytic graphite over a range of primary electron energy levels and electron beam impingement angles are presented. Information required to develop high efficiency multistage depressed collectors (MDC's) for microwave amplifier traveling-wave tubes for space communication and aircraft applications is provided. To attain the highest possible MDC efficiencies, the electrode surfaces must have low secondary electron emission characteristics. Pyrolytic graphite, a chemically vapor-deposited material, is a particularly promising candidate for this application. The pyrolytic graphite surfaces studied were tested over a range of primary electron beam energies and beam impingement angles from 200 to 2000 eV and direct (0 deg) to near-grazing angles (85 deg), respectively. Surfaces both parallel to and normal to the planes of material deposition were examined. The true secondary electron emission and reflected primary electron yield characteristics of the pyrolytic graphite surfaces are compared to those of sooted control surfaces.

Curren, A. N.↗

Novel 4x4 SiPM array readout with integrated preamplification stage, optimized for the PWO detectors of the EIC EEEMCal

Here we are reporting on a new readout circuit developed for the lead tungstate (PbWO4) scintillation detectors for the Electron Ion Collider (EIC) Electron Endcap Electromagnetic Calorimeter EEEMCal. The high magnetic field region precludes the use of photomultiplier tubes while the detector requirements specify good spectral resolution performance and fast pulse integration over a large dynamic range. We selected a silicon photomultiplier (SiPM) from Hamamatsu and produced a matrix of 4 x 4 sensors to cover the 20 mm x 20 mm scintillator coupling surface. Signal acquisition and amplification electronics boards were designed and integrated with the sensor board to produce a compact high performance readout package. A prototype detector was built and tested at Jefferson Lab with encouraging resolution and timing performance results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scalable and Resilient Etched Metallic Micro- and Nanostructured Surfaces for Enhanced Flow Boiling

Flow boiling and evaporation in tubes and channels occur in a wide variety of energy systems, such as refrigeration, air conditioning, power generation, electronics cooling, distillation, and purification. In this work, we demonstrate remarkably increased heat transfer coefficients of 270% during refrigerant flow boiling in scalable microstructured (~40 µm), industrial-scale (~1 m long) aluminum (Al) tubes, when compared to smooth unstructured Al tubes. To achieve scalable nanomanufacturing, we create highly conformal and durable structured surfaces by relying on hydrochloric acid Al etching. Flow boiling tests were conducted in 6.35 mm diameter Al tubes using R134a refrigerant as the working fluid. To benchmark our approach and to elucidate the effect of the structure length scale, we also fabricated ultrascalable boehmite (AlO(OH)) nanostructured (~300 nm) Al tubes, showing that etched microscale features are necessary and key to enhancement. Durability tests conducted using a 28 day long continual flow boiling experiment demonstrated negligible degradation of the etched surfaces. The scalable and cost-effective techniques used to create these durable, etched-Al microstructures may significantly reduce manufacturing cost when contrasted with current enhancement approaches such as extrusion, drawing, and welding.

36 MATERIALS SCIENCE↗

Electron kinetics in a positive column of AC discharges in a dynamic regime

Abstract We have performed hybrid kinetic-fluid simulations of a positive column in alternating current (AC) argon discharges over a range of driving frequencies f and gas pressure p for the conditions when the spatial nonlocality of the electron energy distribution function (EEDF) is substantial. Our simulations confirmed that the most efficient conditions of plasma maintenance are observed in the dynamic regime when time modulations of mean electron energy (temperature) are substantial. The minimal values of the root mean square electric field and the electron temperature have been observed at f/p values of about 3 kHz Torr −1 in a tube of radius R = 1 cm. The ionization rate and plasma density reached maximal values under these conditions. The numerical solution of a kinetic equation allowed accounting for the kinetic effects associated with spatial and temporal nonlocality of the EEDF. Using the kinetic energy of electrons as an independent variable, we solved an anisotropic tensor diffusion equation in phase space. We clarified the role of different flux components during electron diffusion in phase space over surfaces of constant total energy. We have shown that the kinetic theory uncovers a more exciting and rich physics than the classical ambipolar diffusion (Schottky) model. Non-monotonic radial distributions of excitation rates, metastable densities, and plasma density have been observed in our simulations at pR > 6 Torr cm. The predicted off-axis plasma density peak in the dynamic regime has never been observed in experiments so far. We hope our results stimulate further experimental studies of the AC positive column. The kinetic analysis could help uncover new physics even for such a well-known plasma object as a positive column in noble gases.

Physics↗

The ground station high-power traveling-wave tube

The M4040 is a 2-kw CW traveling-wave tube developed specifically for communications applications. It was used as the power amplifier in the Project Telstar ground transmitter. Analytic methods employed in the design of the electron gun, the beam collector, the RF circuit and the output match are presented. Typical performance characteristics and drawings of the tube subassemblies serve to describe the electrical and physical features of the M4040 traveling-wave tube. Methods used to inhibit oscillation and the effects of ion drainage and collector depression on tube performance are also discussed.

TRAVELING WAVE TUBE↗

Fermiology and transport properties of the candidate topological crystalline insulator SrAg 4 ⁢Sb 2

Compared to time-reversal symmetry-protected ℤ 2 topological insulators and Dirac/Weyl semimetals, there are significantly fewer candidates for topological crystalline insulators. SrAg 4 ⁢Sb 2 is predicted to exhibit topological crystalline insulator behavior when considering spin-orbit coupling. In this study, we systematically investigate single crystals of SrAg 4 ⁢Sb 2 using electrical transport and magnetic torque measurements, along with first-principles calculations. Our transport data reveals its compensated semimetal nature with a magnetoresistance up to around 700% at 2 K and 9 T. Analysis of de Haas–van Alphen oscillations uncovers a Fermi surface consisting of three distinct Fermi pockets with light effective masses. Comparison between the three-dimensional fermiology obtained from our oscillation data and the first-principles calculations demonstrates excellent agreement. This confirms the accuracy of the calculations, which indicate a band inversion centered at the 𝑇 point and identify the existence of nontrivial tube and needle hole Fermi pockets at Γ, alongside one trivial diamond electron pocket at the 𝐹 point in the Brillouin zone. Furthermore, symmetry and topology analysis results in two potential sets of topological invariants, suggesting the emergence of two-dimensional gapless Dirac surface states either on the 𝑎⁢𝑏 planes or on both the 𝑎⁢𝑏 planes and mirror planes, protected by crystal symmetries. Therefore, SrAg 4 ⁢Sb 2 emerges as a promising candidate topological crystalline insulator.

36 MATERIALS SCIENCE↗

Experimental 4D Tracking of a Single Electron in IOTA

We present the results of the first experiments on 4-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. During the next few months, full 6D tracking will be implemented. This technology makes it possible to characterize the motion of a single particle, i.e. simultaneously tracking of amplitudes and phases for slow synchrotron oscillations and fast betatron oscillations. Complete tracking of a single particle enables the first direct measurements of dynamical properties, including invariants, amplitude-dependent tunes, and chaotic behavior.

43 PARTICLE ACCELERATORS↗

Complete 6D tracking of a single electron in the IOTA ring

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, amplitude and energy dependence of tunes with exceptional precision, and chaotic behavior.

43 PARTICLE ACCELERATORS↗

Particle Accelerators at the Intensity Frontier for Elementary Particle Physics Research

In 1897, Prof. J. J. Thomson used a cathode ray tube that operated at a few kiloelectron volts (keV) to discover the electron and measured its charge-to-mass ratio. In this case, the electrons were not created, but ejected from hot filament. This experiment is considered to be one of the earliest uses of particle accelerators in elementary particle physics research. Imparting a few keV of energy to a beam of electrons was considered as high energy at that time. The meaning of the phrase High Energy Physics (HEP) has changed significantly over the last century.

43 PARTICLE ACCELERATORS↗

On display: Replica instruments used to discover electrons, neutrons and more

Believe it or not, the electron was discovered in 1897 using only a hand-blown glass tube, a vacuum pump and some electrodes. Historical instrument replicas now on display in the lobby of the J.R. Oppenheimer Center give visitors a chance to remember the elegance — and relative simplicity — of the instruments scientists built and used to make pivotal discoveries.

47 OTHER INSTRUMENTATION↗

Single-Electron Tracking (SETI)

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, tunes dependence on amplitudes with exceptional precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Complete 6D Tracking of a Single Electron in the IOTA Ring

We present the results of the first experiments on 6-dimensional phase-space tracking of a single electron in a storage ring, using a linear multi-anode photomultiplier tube for simultaneously measuring transverse coordinates and arrival times of synchrotron-radiation pulses. This technology makes it possible to fully reconstruct turn-by-turn positions and momentums in all three planes for a single particle. Complete experimental particle tracking enables the first direct measurements of dynamical properties, including invariants, amplitude and energy dependence of tunes with exceptional precision, and chaotic behavior.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electronic skewing circuit monitors exact position of object underwater

Linear Variable Differential Transformer /LVDT/ electronic skewing circuit guides a long cylindrical capsule underwater into a larger tube so that it does not contact the tube wall. This device detects movement of the capsule from a reference point and provides a continuous signal that is monitored on an oscilloscope.

Roller, R.↗

The interaction of moderately strong shock waves with thick perforated walls of low porosity

A theoretical prediction is given of the flow through thick perforated walls of low porosity resulting from the impingement of a moderately strong traveling shock wave. The model was a flat plate positioned normal to the direction of the flow. Holes bored in the plate parallel to the direction of the flow provided nominal hole length-to-diameter ratios of 10:1 and an axial porosity of 25 percent of the flow channel cross section. The flow field behind the reflected shock wave was assumed to behave as a reservoir producing a quasi-steady duct flow through the model. Rayleigh and Fanno duct flow theoretical computations for each of three possible auxiliary wave patterns that can be associated with the transmitted shock (to satisfy contact surface compatibility) were used to provide bounding solutions as an alternative to the more complex influence coefficients method. Qualitative and quantitative behavior was verified in a 1.5- by 2.0-in. helium shock tube. High speed Schlieren photography, piezoelectric pressure-time histories, and electronic-counter wave speed measurements were used to assess the extent of correlation with the theoretical flow models. Reduced data indicated the adequacy of the bounding theory approach to predict wave phenomena and quantitative response.

Grant, D. J.↗

Atomic processes in astrophysics.

Studies of particle excitation processes in the solar corona are reviewed, covering electron affinities, negative ion experiments using two-photon laser and drift tube techniques, geometrical hindrance in molecular ion formation, negative ion-molecule reactions, and negative ions in the ionosphere and astrophysics. Aspects of forbidden atomic transitions are also discussed, including the calculation of transition probabilities, the Fe II problem, and magnetic quadrupole radiation in a relativistic approximation.

Garstang, R. H.↗

Shift measurements of the stark-broadened ionized helium lines at 1640 and 1215 angstrom

Time-resolved measurements were made of the shifts of the ionized helium lines at 1,640 A (n = 3 approaches 2) and 1,215 A (n = 4 approaches 2), and of the Stark profile of the 1,215 A wavelength line. An electromagnetic shock tube was used as a light source. The plasma conditions corresponded to electron temperatures of approximately 3.5 eV and electron densities of 0.8 to 1.8 x 10 to the 17th power/cubic cm. The measured shifts fell between two previous estimates of plasma polarization shifts. The measured Stark width of the 1,215 A wavelength line was up to 30% greater than the theoretical width.

Vanzandt, J. R.↗