Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrodes construction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Strong Electronic Coupling of Molecular Sites to Graphitic Electrodes via Pyrazine Conjugation

Glassy carbon electrodes were functionalized with redox-active moieties by condensation of o-phenylenediamine derivatives with o-quinone sites native to graphitic carbon surfaces. Electrochemical and spectroscopic investigations establish that these graphite-conjugated catalysts (GCCs) exhibit strong electronic coupling to the electrode, leading to electron transfer (ET) behavior that diverges fundamentally from that of solution-phase or surface-tethered analogues. We find that (1) ET is not observed between the electrode and a redox-active GCC moiety regardless of applied potential. (2) ET is observed at GCCs only if the interfacial reaction is ion-coupled. (3) Even when ET is observed, the oxidation state of a transition metal GCC site remains unchanged. From these observations, we construct a mechanistic model for GCC sites in which ET behavior is identical to that of catalytically active metal surfaces rather than to that of molecules in solution. These results suggest that GCCs provide a versatile platform for bridging molecular and heterogeneous electrocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dark phase effect in the evolution of the positive column of a glow discharge in nitrogen

The characteristics of the initial stage of the formation of the positive column of a glow discharge in nitrogen at reduced pressures are studied experimentally and numerically. A dip in the plasma emission intensity in the initial stage of the discharge (the so-called 'dark phase') is observed experimentally at the positive polarity of the high-voltage electrode (the cathode is grounded). The dark phase is preceded by an ionization wave (IW). When the anode is grounded, neither an IW nor a dip in the discharge emission intensity are observed. A theoretical model capable of describing the discharge development under the actual experimental conditions is constructed. It is shown that the dark phase effect may be caused by the high electron density (above the steady-state one) produced in the gas during the passage of the IW across the discharge gap. This mechanism of the dark phase formation differs from the mechanism proposed earlier to explain a similar effect in noble gases. Additional experiments carried out with pure argon, helium, and helium with a nitrogen admixture have shown that, in the case of a grounded cathode, gas breakdown is also accompanied by the passage of an IW, whereas in the case of a grounded anode, no IW is observed; however, the dark phase is present in both cases. It is shown using computer simulations that, in nitrogen (in contrast to noble gases), the mechanism resulting in the dark phase effect does not operate in the absence of an IW.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel electron tunneling infrared detector

The pneumatic infrared detector, originally developed by Golay in the late 1940s, uses the thermal expansion of one cm(exp 3) of xenon at room temperature to detect the heat deposited by infrared radiation. This detector was limited by thermal fluctuations within a 10 Hz bandwidth, but suffered from long thermal time constants and a fragile structure. Nevertheless, it represents the most sensitive room temperature detector currently available in the long wavelength infrared (LWIR). Fabrication of this type of detector on smaller scales has been limited by the lack of a suitably sensitive transducer. Researchers designed a detector based on this principle, but which is constructed entirely from micromachined silicon, and uses a vacuum tunneling transducer to detect the expansion of the trapped gas. Because this detector is fabricated using micromachining techniques, miniaturization and integration into one and two-dimensional arrays is feasible. The extreme sensitivity of vacuum tunneling to changes in electrode separation will allow a prototype of this detector to operate in the limit of thermal fluctuations over a 10 kHz bandwidth. A calculation of the predicted response and noise of the prototype is presented with the general formalism of thermal detectors. At present, most of the components of the prototype have been fabricated and tested independently. In particular, a characterization of the micromachined electron tunneling transducer has been carried out. The measured noise in the tunnel current is within a decade of the limit imposed by shot noise, and well below the requirements for the operation of an infrared detector with the predicted sensitivity. Assembly and characterization of the prototype infrared detector will be carried out promptly.

Kenny, T. W.↗

Improving Satellite Compatible Microdevices to Study Biology in Space

The technology for biology in space lags far behind the gold standard for biological experiments on Earth. To remedy this disparity, the Rothschild lab works on proof of concept, prototyping, and developing of new sensors and devices to further the capabilities of biology research on satellites. One such device is the PowerCell Payload System. One goal for synthetic biology in aiding space travel and colonization is to genetically engineer living cells to produce biochemicals in space. However, such farming in space presupposes bacteria retain their functionality post-launch, bombarded by radiation, and without the 1G of Earth. Our questions is, does a co-culture of cyanobacteria and protein-synthesizing bacteria produce Earth-like yields of target proteins? Is the yield sensitive to variable gravitational forces? To answer these questions, a PowerCell Payload System will spend 1 year aboard the German Aerospace Center's Euglena and Combined Regenerative Organic-food Production In Space (Eu:CROPIS) mission satellite. The PowerCell system is a pair of two 48-well microfluidic cards, each well seeded with bacteria. The system integrates fluidic, thermal, optical, electronic, and control systems to germinate bacteria spores, then measure the protein synthesized for comparison to parallel experiments conducted on the Earth. In developing the PowerCell Payload, we gained insight into the shortcomings of biology experiments on satellites. To address these issues, we have started three new prototyping projects: 1) The development of an extremely stable and radiation resistant cell-free system, allowing for the construction of proteins utilizing only cell components instead of living cells. This can be lyophilized on a substrate, like paper. (2) Using paper as a microfluidic platform that is flexible, stable, cheap, and wicking. The capillary action eliminates the need for pumps, reducing volume, mass, and potential failing points. Electrodes can be printed on the paper to sense for biochemicals. (3) Developing a modular, semi-autonomous microfluidic device that can be easily adapted for a variety of common biological experiments. This versatility will allow for quicker and cheaper experimentation. These improvements to satellite experiment platforms have the potential to radically increase the return from NASA's biological and field studies with reduced development time, mass, and cost with increased robustness data and interpretation.

biology in spac↗

Chaotic characteristics of corona discharges in atmospheric air

A point-plane electrode system in atmospheric air is established to investigate the mechanism of the corona discharge. By using this system, the current pulses of the corona discharges under the 50 Hz ac voltage are measured using partial discharge (PD) measurement instrument and constitute the point-plane voltage-current (V-I) characteristic equation together with the voltage. Then, this paper constructs the nonlinear circuit model and differential equations of the system in an attempt to give the underlying dynamic mechanism based on the nonlinear V-I characteristics of the point-plane corona discharges. The results show that the chaotic phenomenon is found in the corona circuit by the experimental study and nonlinear dynamic analysis. The basic dynamic characteristics, including the Lyapunov exponent, the existence of the strange attractors, and the equilibrium points, are also found and analyzed in the development process of the corona circuit. Moreover, the time series of the corona current pulses obtained in the experiment is used to demonstrate the chaotic characteristics of the corona current based on the nonlinear dynamic circuit theory and the experimental basis. It is pointed out that the corona phenomenon is not a purely stochastic phenomenon but a short term deterministic chaotic activity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Results of a 10 kJ Z-Pinch

Preliminary results obtained on 10 kJ Z-pinch device developed at the Plasma and Electrical Discharge Laboratory in the University of Castilla-La Mancha are presented. The device called ENERGU-1 is composed by 8 capacitors (0.5 {mu}F, 75 kV, 20 nH) connected in parallel to a discharge chamber by means of one high power plane transmission line by mean of 8 spark-gaps switches triggered by a 100 kV, 13 ns trigger pulse. The discharge chamber is a cylindrical Pyrex glass tube externally surrounded by a SF{sub 6} isolation atmosphere with the electrodes at the ends. Two different chambers have been studied by discharging the capacitor bank energy in deuterium for optimizing the D-D nuclear fusion reactions: one of 100 mm long by 100 mm inner diameter and the other of the same length and 70 mm inner diameter. Several sequences of ultrahigh speed converter camera photography (5 ns) are presented showing the implosion of plasma columns for different deuterium pressure and currents. Preliminary measurements of integrated 2.45 MeV neutron emissions by a silver activated neutron counter are analyzed as a function of electrical and constructive parameters. A yield of 10{sup 7}-10{sup 8} D-D fusion reactions by shot is reported when the optimum conditions are reached conducting currents of 400-600 kA with a plasma column lifetime above 100 ns.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electro-chemo-mechanically Driven Ni Exsolution from (Pr,Ce,Ni)O 2−δ : Controlled Nucleation Density and Enhanced Electrode Kinetics

In situ exsolution of metal nanoparticles is a promising strategy to prepare electrocatalysts with enhanced activity and resistance to agglomeration for efficient chemical transformations and energy conversion. Achieving a high nucleation density of nanoparticles under mild conditions and understanding how to tailor the process is important for performance of these electrodes in electrochemical cells. In this work, we demonstrate facile exsolution of Ni nanoparticles using fluorite-structured (Pr,Ce)O 2−δ as the support oxide, driven by electrochemical potential and aided by the metastability of Ni in the solid solution (elastic driving force). We prepare single-phase oriented thin films of (Pr,Ce,Ni)O 2−δ (NPCO) on (Zr,Y)O 2−δ (YSZ) substrates by pulsed laser deposition. With the aid of a high-throughput electrochemical cell that provides a lateral gradient in Nernst voltage, we apply in situ near-ambient pressure synchrotron X-ray photoelectron spectroscopy and ex situ atomic force microscopy to investigate the impact of electrochemical potential on Ni nucleation density. We find that metallic Ni can be successfully exsolved at 550 °C upon cathodic biasing in 20 mTorr O 2 , and its nucleation density increases with increasing electrochemical driving force/decreasing oxygen chemical potential. We further evaluate the electrochemical performance under highly reducing (fuel electrode) conditions by electrochemical impedance spectroscopy. With the exsolved Ni nanoparticles, the surface exchange coefficient of the NPCO is found to be ∼4× higher than for PCO without exsolution. This work confirms mixed conducting fluorites as beneficial host lattices for facile transition-metal exsolution and suggests the possibility for constructing an all ceria-based electrochemical cell with PCO serving as both the cathode and the anode.

36 MATERIALS SCIENCE↗

Field-emission-type x-ray source using carbon-nanofibers

An x-ray irradiation system of field-emission type has been constructed using carbon-nanofibers (CNFs) grown on a palladium wire that is 50 {mu}m in diameter. The electron current emitted from the CNFs was approximately 1 mA and was stable within 10% for a long time t>5000 h. The electrons passing through a slit in the gate electrode were accelerated to the desired energy, and were made to impinge on the metal target (Ti, Cu, Mo, and W) for generating x rays. The x-rays transmitted through Be-window were characterized using energy analyzers and a dosimeter. At an acceleration voltage of V{sub a}=50 kV, the energy spectra of the x-rays were exclusively composed of characteristic signals except for the Mo-target, and the dose rates of x-rays were D=2.5-14 Gy/min, depending on the target metals. This system also provides sharp x-ray images of both biological and nonbiological materials.

36 MATERIALS SCIENCE↗

Optical interferometry of high-energy nanosecond pin-to-pin discharges in atmospheric air

This paper describes the construction and application of an optical-frequency Michelson interferometer for measuring electron number density within high-energy, high-power nanosecond pin-to-pin discharges (>10 mJ pulse energy, >1 MW pulse power). A 21 mJ, 11 ns spark across a 3 mm pin-to-pin electrode gap was analyzed at 7 ns into the discharge to demonstrate the operation of the interferometer. A peak electron density of 2.3 × 10 17 cm −3 was observed at these conditions, and it was consistent with estimates of plasma channel resistance based on V–I measurements. This initial work paves the way for a larger parametric study of the spatial and temporal dynamics of electron number density in nanosecond pin-do-pin discharges under various conditions.

electron number density↗

Transducers for ultrasonic limb plethysmography

The design, construction, and performance characteristics of ultasonic transducers suitable for limb plethysmography are presented. Both 3-mm-diameter flat-plate and 12-mm-diameter hemispheric ceramic transducers operating at 2 MHz were fitted in 1-mm thick epoxy-resin lens/acoustic-coupling structures and mounted in exercie-EKG electrode housings for placement on the calf using adhesive collars. The effects of transducer directional characteristics on performance under off-axis rotation and the electrical impedances of the transducers were measured: The flat transducer was found to be sensitive to rotation and have an impedance of 800 ohms; the hemispheric transducer, to be unaffected by rotation and have an impedance of 80 ohms. The use of hemispheric transducers as both transmitter and receiver, or of a flat transducer as transmitter and a hemispheric transducer as receiver, was found to produce adequate dimensional measurements, with minimum care in transducer placement, in short-term physiological experiments and long-term (up to 7-day) attachment tests.

Nickell, W. T.↗

Electrostatic Spraying With Conductive Liquids

Thin, uniform polymer coatings applied in water base normally impossible to charge. Electrostatic sprayer modified so applies coatings suspended or dissolved in electrically conductive liquids. Nozzle and gun constructed of nonconductive molded plastic. Liquid passageway made long enough electrical leakage through it low. Coaxial hose for liquid built of polytetrafluoroethylene tube, insulating sleeve, and polyurethane jacket. Sprayer provided with insulated seal at gun-to-hose connection, nonconductive airhose, pressure tank electrically isolated from ground, and special nozzle electrode. Supply of atomizing air reduced so particle momentum controlled by electrostatic field more effectively. Developed to apply water-base polyurethane coating to woven, shaped polyester fabric. Coating provides pressure seal for fabric, which is part of spacesuit. Also useful for applying waterproof, decorative, or protective coatings to fabrics for use on Earth.

Kosmo, Joseph J.↗

Metallography of Battery Resistance Spot Welds

Li-ion cells provide an energy dense solution for systems that require rechargeable electrical power. However, these cells can undergo thermal runaway, the point at which the cell becomes thermally unstable and results in hot gas, flame, electrolyte leakage, and in some cases explosion. The heat and fire associated with this type of event is generally violent and can subsequently cause damage to the surrounding system or present a dangerous risk to the personnel nearby. The space flight environment is especially sensitive to risks particularly when it involves potential for fire within the habitable volume of the International Space Station (ISS). In larger battery packs such as Robonaut 2 (R2), numerous Li-ion cells are placed in parallel-series configurations to obtain the required stack voltage and desired run-time or to meet specific power requirements. This raises a second and less obvious concern for batteries that undergo certification for space flight use: the joining quality at the resistance spot weld of battery cells to component wires/leads and battery tabs, bus bars or other electronic components and assemblies. Resistance spot welds undergo materials evaluation, visual inspection, conductivity (resistivity) testing, destructive peel testing, and metallurgical examination in accordance with applicable NASA Process Specifications. Welded components are cross-sectioned to ensure they are free of cracks or voids open to any exterior surface. Pore and voids contained within the weld zone but not open to an exterior surface, and are not determined to have sharp notch like characteristics, shall be acceptable. Depending on requirements, some battery cells are constructed of aluminum canisters while others are constructed of steel. Process specific weld schedules must be developed and certified for each possible joining combination. The aluminum canisters' positive terminals were particularly difficult to weld due to a bi-metal strip that comes ultrasonically pre-welded by the manufacturer. This was further complicated as the maximum electrode force was limited to low-electrode force to prevent deflection of the aluminum can during welding. Other Li-ion cells are comprised of smaller diameter cylindrical steel canisters which are inherently capable of handling greater force from the electrodes. Allowing higher-electrode forces aids greatly in insuring a consistent resistance network for the weld. Overall lessons learned: developing good jigs is critical to insure the parts and electrodes are planer to one another and the location of the weld sites remains accurate and repeatable; maintaining strict control over materials is critical--materials must be of a specific hardness and chemical composition to insure that a weld schedule is repeatable; accuracy of the die used to stamp the projections is critical and worth the investment; and proper seasoning of the electrodes is critical to producing consistent welds--once the electrodes have been properly seasoned, cleaning/dressing should be avoided until it is absolutely necessary.

Martinez, J. E.↗

Effect of MWCNT on prepared cathode material (Li{sub 2}Mn{sub (x)}Fe{sub (1-x)}SiO{sub 4}) for energy storage applications

The electrode material Li{sub 2}MnFeSiO{sub 4} was successfully synthesized by standard sol–gel method and further modified with multiwalled carbon nano tube (MWCNT) to achieve better electrochemical properties. Our strategy helps us to improve the performance and storage capacity as compared with the bared material. This novel composite structure constructs an efficient cation (Li{sup +}) and electron channel which significantly enhance the Li{sup +} ion diffusion coefficient and reduced charge transfer resistance. Hence leads to high conductivity and specific capacity. Characterization technique like Field emission scanning electron microscopy (FESEM) has been used to confirm its morphology, structure and particle size which comes out to be of the order of ∼20 to 30 nm. Lesser particle size reveals better electrochemical properties. Electrical conductivity (∼10{sup −5} Scm{sup −1}) of MWCNT doped oxide cathode materials was recorded using ac impedance spectroscopy technique which reflects tenfold increment when compared with pure oxide cathode materials. Cyclic voltametery analysis has been done to calculate specific capacity and potential window of materials with and without CNTs. The results obtained from different techniques are well correlated and suitable for energy storage applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

MO-AB-BRA-08: A Modular Multi-Source X-Ray Tube for Novel Computed Tomography Applications

Purpose: To develop and build a practical implementation of an x-ray line source for the rapidly increasing number of multi-source imaging applications in CT. Methods: An innovative x-ray tube was designed using CST Particle Studio, ANSYS, and SolidWorks. A slowly varying magnetic field is synchronized with microsecond gating of multiple thermionic electron sources. Electrostatic simulations were run to optimize the geometry of the optics and prevent electrode arcing. Magnetostatic simulations were used for beam deflection studies and solenoid design. Particle beam trajectories were explored with an emphasis on focusing, acceleration, deflection, and space charge effects. Thermal constraints were analyzed for both transient and steady-state regimes. Electromagnetic simulations informed the design of a prototype unit under construction. Results: Particle tracking simulations for a benchtop system demonstrate that three 80 keV electron beams are able to be finely controlled and laterally swept a combined distance of 15 cm over a stationary target with an oscillating magnetic field in the hundreds of gauss. The beams are pulsed according to scanning sequences developed for implementation in a mock stationary CT scanner capable of a 30 ms temporal resolution. Beam spot diameters are approximately 1 mm for 30 mA beams and the stationary target stays well within thermal limits. The relevant hardware and control circuits were developed for incorporation into a physical prototype. Conclusion: A new multi-source x-ray tube was designed in a modular form factor to push the barriers of high-speed CT and spur growth in emerging imaging applications. This technology can be used as the basis for a stationary high-speed CT scanner, a system for generating a virtual fan-beam for dose reduction, or for reducing scatter radiation in cone-beam CT utilizing a tetrahedron beam CT geometry. A 2.4 kW benchtop system is currently being built to show proof of concept for the tube. Support for this research was provided by the University of Wisconsin Madison, Office of the Vice Chancellor for Research and Graduate Education with funding from the Wisconsin Alumni Research Foundation.

60 APPLIED LIFE SCIENCES↗

An Adaptable Device for Scalable Electrospinning of Low- and High-Viscosity Solutions

This paper summarizes the design and construction of an adaptable electrospinner capable of spinning fluids over a large range of viscosities. The design accommodates needless electrospinning technologies and enables researchers to explore a large range of testing parameters. Modular parts can be exchanged for alternative versions that adapt to the research question at hand. A rotating drum electrode immersed halfway into a solution bath provides the liquid film surface from which electrospinning occurs. We tested and assessed several electrode designs and their electrospinning performance at higher (<500 poise) viscosities. Relative humidity was found to affect the onset of electrospinning of highly viscous solutions. We demonstrate robust device performance at applied voltage up to 90 kV between the electrospinning electrode and the collector. Design and fabrication aspects are discussed in practical terms, with the intent of making this device reproducible in an academic student machine shop.

McCarty, Ryan J. (ORCID:0000000224178917)↗

Nonlinear Polarization Effects in Dielectrics with Hydrogen Bonds

Using quasiclassical kinetic theory, nonlinear phenomena under the formation of space-charge polarization in crystals with hydrogen bonds (HBC) are investigated. From the solution of the nonlinear system of Fokker-Planck and Poisson equations with blocking electrodes, it is established that for the mathematical description of the relaxation polarization in HBCs in weak fields (100-1000 kV/m) and at high temperatures (T> 350 K), it is sufficient to use a linear approximation of perturbation theory. Theoretically, it was found that at the first odd frequency of the alternating field, nonlinear effects caused by the interaction of relaxation modes of various frequency orders start to appear. The diffusion and mobility coefficients are calculated taking into account both mechanisms of the protons transitions (thermally activated and tunneling transitions) through a parabolic potential barrier. A recurrence expression is constructed for calculating complex amplitudes of relaxation modes generated at an arbitrary frequency (multiple to the fundamental frequency) of the alternating field in an arbitrary approximation of perturbation theory. The proposed scheme for solving the kinetic equation can be applied to other crystals with ionic conductivity similar to HBCs in the type and properties of the crystal lattice.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Parallel Spectral Acquisition with Orthogonal ICR Cells

FT-based high performance mass analyzers yield increased resolving power and mass measurement accuracy, yet require increased duration of signal acquisition that can limit many applications. The implementation of stronger magnetic fields, multiple detection electrodes for harmonic signal detection, and an array of multiple mass analyzers arranged along the magnetic field axis have been used to decrease required acquisition time. The results presented here show that multiple ion cyclotron resonance (ICR) mass analyzers can also be implemented orthogonal to the central magnetic field axis. The orthogonal ICR cell system presented here consisting of two cells (master and slave cells) was constructed with printed circuit boards and installed within a single superconducting magnet and vacuum system. A master cell was positioned, as is normally done with ICR cells, on the central magnetic field axis and a slave cell was located off this central axis, but directly adjacent and alongside the master cell. To achieve ion transfer between cells, ions that were initially trapped in the master cell were drifted across the magnetic field into the slave cell with application of a small DC field applied perpendicularly to the magnetic field axis. A subsequent population of ions was injected and accumulated in the master cell. Simultaneous excitation of cyclotron motion of ions in both cells was carried out; ICR signals from each cell were independently amplified and recorded in parallel. Presented here are the initial results of successful parallel spectral acquisition with this orthogonal dual ICR cell array. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

All-back-contact perovskite solar cells

The present disclosure relates to an all-back-contact photovoltaic device that includes, in order, a substrate, a first electrode having a first surface, an insulator, a second electrode having a second surface, and an active material, where the insulator and the second electrode form a cavity, the active material substantially fills the cavity and is in physical contact with the first surface and the second surface, the insulator includes a first layer and a second layer with the second layer positioned between the first layer and the second contact, and the first layer is constructed of a first material that is different than a second material used to construct the second layer.

Prince, Kevin Joseph↗