Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric sector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

The Role of Fuels in Transforming Energy End-Use in Buildings and Industrial Processes

This book examines what role fuels have in the transformation of end-use in buildings and industrial processes. Energy efficient technologies are necessary to lower the carbon footprint for a transition towards clean energy in a sustainable manner. Efficient utilization of primary energy resources including renewables to support the current and future energy needs while targeting grid resiliency, energy and environmental security, at an affordable cost is of significant value. Analysis of configurations consisting of heat pumps, fuel driven thermal providers and power systems is presented. Sensitivity of electrical grid's carbon intensity towards carbon footprint in comparison with fuel driven technologies is necessary to recognize the true value proposition of currently available energy solutions for different end consumers. Similarly, the role of low carbon, zero carbon, and carbon negative fuels such as power to gas, power to liquid, hydrogen, biogas, etc. in conjunction with polygeneration technologies are discussed. Transformation of the primary energy resources from conventional fossil fuels to renewable fuels or electricity will have a significant impact on the overall carbon footprint of various end use sectors, including buildings. Hence, this book also examines two different scenarios focused on sensitivity of the pace of decarbonization of electrical grid and fuel supply on operational energy related carbon emissions.

Cheekatamarla, Praveen↗

Electric field measurements across the harang discontinuity

The Harang discontinuity, the area separating the positive and negative bay regions in the midnight sector of the auroral zone, is a focal point for changes in behavior of many phenomena. Through this region the electric field rotates through the west from a basically northward field in the positive bay region to a basically southward field in the negative bay region, appearing as a reversal in a single axis measurement; 32 of these reversals have been identified in the OGO-6 data from November and December, 1969. The discontinuity is dynamic in nature, moving southward and steepening its latitudinal profile as magnetic activity is increased. As activity decreases it relaxes poleward and spreads out in latitudinal width. It occurs over several hours of magnetic local time. The boundary in the electric field data is consistent with the reversal of ground magnetic disturbances from a positive to negative bay condition. The discontinuity is present in the electric field data both during substorms and during quiet times and appears to define a pattern on which other effects can occur.

Maynard, N. C.↗

Electric field measurements across the Harang discontinuity

The Harang discontinuity, the area separating the positive and negative bay regions in the midnight sector of the auroral zone, is a focal point for changes in behavior of many phenomena. Through this region the electric field, in a frame corotating with the earth, rotates through the west from a basically northward field in the positive bay region to a basically southward field in the negative bay region, appearing as a reversal in a single-axis measurement of the north-south component. Thirty-two of these reversals have been identified in the Ogo 6 data from November and December 1969. The discontinuity is dynamic in nature, moving southward and steepening its latitudinal profile as magnetic activity is increased. As activity decreases, it relaxes poleward and spreads out in latitudinal width. It occurs over several hours of magnetic local time.

Maynard, N. C.↗

Industrial battery operation and utilization in the presence of electrical load uncertainty using Bayesian decision theory

Behind the meter battery storage is becoming increasing popular in all sectors, though enthusiasm has recently lagged in the industrial sector. Even though there may be many factors contributing to this including lack of innovation, prohibitive costs, and undesirable rate structures, a difficulty arises in accounting for uncertainty of electrical load in industrial facilities while still attempting to utilize battery storage as much as possible all while trying to achieve fiscal profitability. Here this study utilizes Gaussian process regression and Bayesian decision theory to organize load data and quantify electrical load uncertainty to properly and effectively discharge industrial battery storage. The study employs a simulation model to set battery load setpoints for the span of the utility billing period according to the degree of risk aversion. This combination of economic analysis according to utility billing period and utilization of degree of risk aversion to make decisions on the uncertainty of the data has not before been applied to battery storage. The method resulted in an annual average reduction of peak demand by 3.8 % at the lowest amount of savings and lowest risk aversion. The highest risk aversion resulted in an annual average reduction of peak demand of 7.5 %. The maximum reduction of peak load in any month was 13.8 % in the month of December with a relatively high risk aversion. With a the highest amount risk aversion tested, the model reduced demand ten of the twelve months of the year.

25 ENERGY STORAGE↗

Design of Phase-Change Thermal Storage Device in a Heat Pump for Building Electric Peak Load Shaving: Preprint

Replacing carbon-intensive fossil fuel heating systems with electric heat pumps powered by renewables is a promising approach to decarbonize the building sector. However, one of the technical barriers of this approach is the large scale of heat demand, which will put excessive stress on the electricity grid. Integrating thermal energy storage (TES) into the heating systems can help alleviate this problem, by shifting thermal load and thus shaving peaks in the building electric load. Therefore, it is critical to understand how to design a thermal storage device in a heat pump for peak load shaving. In this study, we developed a numerical model for a cascaded vapor compression heat pump system integrating a phase change thermal storage device. This novel system can control the net thermal charging and discharging rate of the TES independently from the building's thermal load, which allows for precise control of electric power use. In the current study, we controlled the system to shave building electric peak load during a cold winter morning, and to charge TES during the relatively warm afternoon while still providing space heating. We used the model to evaluate the system performance with and without peak shaving. We also investigated the effect of PCM transition Tt on the peak reduction and electric energy saving potentials. The results show that peak shaving scheme effectively reduces the peak electric power consumption during a predefined discharge time window. When comparing to the no shaving case, for PCM Tt = 10 degrees C, the peak electric load reduction is 23.5%. When comparing to an air-source heat pump with back up electric heater, as Tt increases from 0 to 20 degrees C, the peak reduction increases from 46.1% to 50.9%. Integrating PCM Tt = 10 degrees C with peak shaving leads to the 45.5% of electric energy saving, which is the highest among the three transition temperatures.

electric energy saving↗

Impact of Open Communication Networks on Load Frequency Control with Plug-in Electric Vehicles by Cyber-Physical Dynamic Co-Simulation: Preprint

With the increasing electrification of the transportation sector, vehicle to grid (V2G) control technologies are promising to improving system frequency stability. However, these control technologies might require non-traditional communication supports. This paper investigates the impacts of electric vehicles (EVs) V2G on power system frequency regulation considering communication variations through transmission-distribution-communication (TDC) dynamic simulation. The simulation model is built based on our previously developed open-source transmission-and-distribution (T&D) dynamic co-simulation framework. Here, we add the communication variation functions (i.e. delay and packet loss) to complete the TDC simulation framework. In the case studies, practical communication variation scenarios are considered when the system experiencing an N-1 generation trip contingency. The considered scenarios include communication delay and packet loss using both homogeneous and heterogeneous assumptions. The delay and packet loss rate are the same in all communication channels in the homogeneous case but varies in the heterogeneous case. The results show the communication delay has an obvious impact on the frequency recovery compared to the communication packet drop. The impacts of the standard deviations of communication delay time and packet drop rate are not significant. The outcomes of this work can help improve the EV frequency regulation services and provide robust and effect supports to the grid.

ADVANCED PROPULSION SYSTEMS,ENERGY PLANNING, POLIC↗

Simultaneous observations of substorm electrons - Explorer 45 and ATS 5

Simultaneous observations of substorm-associated electron flux variations made on the satellites Explorer 45 and ATS 5 are used to infer the value of the dawn-dusk electric field present during a substorm. The observations were made during a substorm which occurred on December 17, 1971, while the two satellites were in the evening local time sector, within the plasma sheet. It is found that a dawn-dusk electric field of about 11 kV/R-E (about 2 mV/m) was present during the substorm. It is shown that the observations made at the two satellites are compatible with the model of a uniform enhanced dawn-dusk electric field acting upon a particle source which is spatially uniform in the region from which particles are convected to synchronous orbit.

Barfield, J. N.↗

Electrodynamics of the Inner Magnetosphere Observed in the Dusk Sector by CRRES and DMSP during the Magnetic Storm of June 4-6, 1991

We compare equatorward/earthward boundaries of convection electric fields and auroral/plasma sheet electrons detected by the DMSP F8 and CRRES satellites during the June 1991 magnetic storm. Measurements come from the dusk magnetic local time sector where the ring current penetrates closest to the Earth. The storm was triggered by a rapid increase in the solar wind dynamic pressure accompanied by a southward turning of the interplanetary magnetic field (IMF). Satellite data show the following: (1) all particle and field boundaries moved equatorward/earthward during the initial phase, probably in response to the strong southward IMF turning; (2) electric field boundaries were either at lower magnetic L shells or close to the inner edge of ring current ions throughout the main and early recovery phases. Penetration earthward of the ring current occurred twice as the polar cap potential increased rapidly; (3) electric potentials at subauroral latitudes were large fractions of the total potentials in the afternoon cell, twice exceeding 60 kV; and (4) the boundaries of auroral electron precipitation were more variable than those of electric fields and mapped to lower L shells than where CRRES encountered plasma sheet electrons. Observations qualitatively agree with predictions of empirical models for auroral electron and electric field boundaries.

Bruke, W. J.↗

Cost of a potential hydrogen-refueling network for heavy-duty vehicles with long-haul application in Germany 2050

Long-distance road-freight transport emits a large share of Germany's greenhouse gas (GHG) emissions. A potential solution for reducing GHG emissions in this sector is to use green hydrogen in fuel cell electric vehicles (FC-HDV) and establish an accompanying hydrogen refueling station (HRS) network. In this paper, we apply an existing refueling network design model to a HDV-HRS network for Germany until 2050 based on German traffic data for heavy-duty trucks and estimate its costs. Comparing different fuel supply scenarios (pipeline vs. on-site), the on-site scenario results show a network consisting of 137 stations at a cost of 8.38 billion € per year in 2050 (0.40 € per vehicle km), while the centralized scenario with the same amount of stations shows a cheaper cost with 7.25 billion euros per year (0.35 € per vehicle km). Finally, the hydrogen cost (LCOH) varies from 5.59 €/kg (pipeline) to 6.47 €/kg (on-site) in 2050.

08 HYDROGEN↗

2020 Review Panel Workshop on Energy Intensity Indicators: Summary Findings and Meeting Notes

On January 28-29, 2020, the U.S. Department of Energy (DOE) Office of Energy Efficiency and Renewable Energy (EERE), in coordination with Pacific Northwest National Laboratory (PNNL), sponsored an expert workshop focused on energy intensity indicators. The intent of the workshop was to support a comprehensive review of the EERE Energy Intensity Indicators (EII), a national system of indicators used to track changes in the energy intensity of economic sectors. One goal of the workshop was to gather input from a panel of experts who have experience and knowledge related to the EII methodological approach and key data sources used to calculate indicators for each of the end-use sectors of the economy—transportation, residential, commercial, industrial, and electricity. The current EERE EII methodology is documented in a 2017 PNNL report, A Comprehensive System of Energy Intensity Indicators for the U.S.: Methods, Data and Key Trends, which is available online. The workshop also included a presentation by Dr. Beng Ang, who discussed the Log Mean Divisia index (LMDI) approach to decomposition analysis, which was followed by a discussion concerning the methodological approaches that could be applied to future EII efforts.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Large-scale offshore wind farm effects on weather and climate in Puerto Rico (Final Technical Report)

Puerto Rico’s current electricity generation heavily relies on imported fossil fuels. This results in an average cost of electricity higher than the U.S. mainland average in all sectors (residential, commercial, and industrial), despite abundant local offshore wind resources, which have the potential to provide secure, low-cost energy generation and consequent economic prosperity. However, effects on atmospheric and oceanic circulation resulting from large-scale deployments of offshore wind farms have not been previously studied at tropical latitude. This project addressed this knowledge gap through a computational modeling effort designed to capture the coupled dynamics of the atmosphere and the ocean in presence of offshore wind farms. Results indicate that wind farm wakes can alter wind stress, generate Ekman-driven vertical transport, and potentially affect nutrient distribution. While full model coupling remains challenging, progress in parameterization and large-eddy simulations provides a foundation for future research. The project contributes to DOE’s Earth System modeling efforts and supports STEM workforce development.

17 WIND ENERGY↗

Comparative Study and Validation of Photovoltaic Model Formulations for the IBPSA Modelica Library based on Rooftop Measurement Data

Domain-overarching system models are crucial to investigate sector coupling concepts. Specifically, the coupling of building and electrical energy systems becomes crucial to integrate renewable energy sources such as photovoltaic power systems (PV). For such interdisciplinary simulation models, Modelica is a suitable language. However, most open-source Modelica libraries are either domain-specific or lack simple-to-parameterize PV models. We close this gap by developing a PV model for the IBPSA Modelica library. The model comprises two I-V-characteristic models and three mounting-dependent approaches to calculate the cell temperature. The I-V-characteristic models follow a single- and two-diodes approach. This study uses measurement data from a rooftop PV system in Berlin, Germany, for validation. The focus lies on comparing the implemented single- and two-diodes approach. Results prove that both models accurately calculate the modules’ DC power output and cell temperature. The two-diodes approach slightly outperforms the single-diode one at the expense of a higher parameterization effort.

Maier, Laura↗

The latitudinal distributions of auroral zone electric fields and ground magnetic perturbations and their response to variations in the interplanetary magnetic field

Measurements of the latitudinal distributions of electric fields obtained with the Chatanika, Alaska, incoherent radar have been employed in determining the influence of the north-south component of the interplanetary magnetic field (IMF) on the electric field pattern. Poleward (or equatorward) shifts produced by the northward (or southward) transitions of the IMF north-south component are given particular attention. The behavior of the electric field patterns and magnetic perturbations in the midnight sector during substorms near the Harang discontinuity is analyzed.

Horwitz, J. L.↗

High-acceleration mass drivers

High-acceleration mass drivers are discussed including the MD2 model of axial geometry, with individually powered drive coils of 13.1 cm diameter. Timing is derived through the interruption of light beams by the moving armature (bucket). Electric power is provided by the resonant discharge of sector capacitor banks through silicon-controlled rectifiers in a two-phase, quadrature circuit. The bucket flies in vacuum, guided by passive dynamic eddy-current magnetic forces, those currents flowing in strip conductors lining the inside of a nonconducting vacuum pipe. Quantitative measurements are obtained with a solid bucket carrying two superconducting coils with a current density of 25 kA/sq cm. A cryogenic station for cooling the bucket to liquid helium temperature is connected to the vacuum pipe.

Oneill, G. K.↗

Ionospheric hot spot at high latitudes

Schunk and Raitt (1980) and Sojka et al. (1981) have developed a model of the convecting high-latitude ionosphere in order to determine the extent to which various chemical and transport processes affect the ion composition and electron density at F-region altitudes. The numerical model produces time-dependent, three-dimensional ion density distributions for the ions NO(+), O2(+), N2(+), O(+), N(+), and He(+). Recently, the high-latitude ionospheric model has been improved by including thermal conduction and diffusion-thermal heat flow terms. Schunk and Sojka (1982) have studied the ion temperature variations in the daytime high-latitude F-region. In the present study, a time-dependent three-dimensional ion temperature distribution is obtained for the high-latitude ionosphere for an asymmetric convection electric field pattern with enhanced flow in the dusk sector of the polar region. It is shown that such a convection pattern produces a hot spot in the ion temperature distribution which coincides with the location of the strong convection cell.

Schunk, R. W.↗

Space Weather: What is it, and Why Should a Meteorologist Care?

"Space weather" is a term coined almost 15 years ago to describe environmental conditions ABOVE Earth's atmosphere that affect satellites and astronauts. As society has become more dependent on technology, we nave found that space weather conditions increasingly affect numerous commercial and infrastructure sectors: airline operations, the precision positioning industry, and the electric power grid, to name a few. Similar to meteorology where "weather" often refers to severe conditions, "space weather" includes geomagnetic storms, radiation storms, and radio blackouts. But almost all space weather conditions begin at the Sun--our middle-age, magnetically-variable star. At NASA, the science behind space weather takes place in the Heliophysics Division. The Space Weather Prediction Center in Boulder, Colorado, is manned jointly by NCAA and US Air Force personnel, and it provides space weather alerts and warnings for disturbances that can affect people and equipment working in space and on Earth. Organizationally, it resides in NOAA's National Weather Service as one of the National Centers for Environmental Prediction. In this seminar we hope to give the audience a brief introduction to the causes of space weather, discuss some of the effects, and describe the state of the art in forecasting. Our goal is to highlight that meteorologists are increasingly becoming the "first responders" to questions about space weather causes and effects.

SaintCyr, Chris↗

Lessons Learned for Responsible Use of Cloud in the Cirrus Project, Following the CrowdStrike Outage Event

A disruption in CrowdStrike’s Falcon cybersecurity platform on July 19th, 2024, caused worldwide chaos. This event highlights the imperative need for cloud security measures for networks that are critically reliant on cloud technology. This incident negatively impacted air travel, government networks, and critical infrastructure sectors such as hospitals and financial institutions. While no electric utilities had a physical impact, and few had an IT impact, there were issues created by loss of cloud services, and other interrelated industries. For utilities and energy distribution organizations, understanding and mitigating these risks is essential. The Cirrus tool offers a strategic solution engineered to weave cloud integration seamlessly into the fabric of operational management, thereby enhancing resilience and streamlining efficiency in the face of digital challenges.

25 ENERGY STORAGE↗

Advancing Transportation Efficiency and Electric Vehicles in Tonga: A Review of Relevant Trends, Best Practices, and Future Work

Tonga is facing a transportation sector characterized by private passenger vehicles, poorly maintained roads and walkways, and an inadequate public transit system. By understanding detailed global and regional trends for transport energy efficiency and electric vehicles (EVs) within this context, the Government of Tonga can proactively plan its future transportation systems. In addition to global and regional trends, this presentation also briefly examines Tonga's own transportation policies and actions. Jurisdictions leading in EV adoption have implemented policies such as reducing taxes on EVs compared to internal combustion engine (ICE) vehicles, providing subsidies and rebates for EV charger installation, instituting an age limit on imported ICE vehicles, and developing EV maintenance courses to expand the skill set of current automotive technicians. This presentation was developed for the Pacific Islands Workshop on Electric Mobility, held from November 28th to November 30th 2022 in Fiji. NREL presented virtually and the conference was sponsored by the Pacific Centre for Renewable Energy and Energy Efficiency (PCREEE).

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗