Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Parameterization of generic positive sequence models to represent behavior of inverter based resources in low short circuit scenarios

The connection of large inverter based resources (IBR) in transmission systems is often located geographically and electrically far away from load centers. This, coupled with the displacement of synchronous machine plants, results in a reduction of the network short circuit strength at the point of connection. Under these conditions, state-of-the-art positive sequence simulation platforms and models can have difficulties maintaining numerical stability and/or providing an accurate representation of IBR plant dynamic behavior. As a result, computationally heavy time domain electromagnetic transient (EMT) simulations may be required to evaluate these systems. In this paper, a recently developed improved generic positive sequence model is parameterized to provide a representation of IBR behavior in low short circuit networks. Further, comparisons against generic and detailed EMT models demonstrate the suitability of the improved positive sequence model to study practical stability issues experienced with presently in-service plants. Such a model can provide some of the accuracy of an EMT representation with a much lower computational burden. The performance of the positive sequence model is validated against the behavior shown by both open white box and closed black box EMT domain models from around the world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An approach for fast and accurate simulation of phase change material based thermal energy storage in buildings

Latent heat thermal energy storage (LHTES) has significant potential for mitigating peak electricity demand and enabling load shifting in buildings. Phase Change Material embedded heat exchangers (PCM-HX) can significantly improve energy demand management due to high storage capacity. However, PCM-HX evaluation typically depends on computationally expensive fully transient simulations, posing significant challenges for scalable system- and building-level energy assessments across different climates and system architectures. This paper presents a generalized, accurate, and computationally efficient methodology for simulating building energy systems integrated with LHTES. The PCM-HX transient performance is represented by performance maps generated using a Generalized Resistance-Capacitance Model (GRCM) that enables accurate predictions of arbitrary PCM-HXs at low computational cost. The feasibility of the proposed approach was verified using a case study considering a dual-mode heat pump-thermal energy storage (HP-TES) system simulated in Modelica with Spawn of EnergyPlus™ for a DOE prototype small office building in two locations: Tampa, FL, and International Falls, MN. The PCM-HX performance maps provided accurate predictions of PCM-HX transient behavior, with mean absolute percentage deviations within 2–4% compared to GRCM while also achieving at least 1800× reduction in computational time. Moreover, the HP-TES system achieved energy savings of up to 17.4% in Tampa, FL, and 62.2% in International Falls, MN, demonstrating the broader applicability of the proposed methodology across different climate zones. This work highlights the importance of robust PCM-HX models in enabling accurate and computationally efficient building-level simulations and enabling future research opportunities for investigating optimized HP-TES designs and advanced control strategies for grid-interactive buildings.

Modelica↗

The Simons Observatory: A fully remote controlled calibration system with a sparse wire grid for cosmic microwave background telescopes

For cosmic microwave background (CMB) polarization observations, calibration of detector polarization angles is essential. We have developed a fully remote controlled calibration system with a sparse wire grid that reflects linearly polarized light along the wire direction. The new feature is a remote-controlled system for regular calibration, which has not been possible in sparse wire grid calibrators in past experiments. The remote control can be achieved by two electric linear actuators that load or unload the sparse wire grid into a position centered on the optical axis of a telescope between the calibration time and CMB observation. Furthermore, the sparse wire grid can be rotated by using a motor. A rotary encoder and a gravity sensor are installed on the sparse wire grid to monitor the wire direction. They allow us to achieve detector polarization angle calibration with an expected systematic error of 0.08°. The calibration system will be installed in small-aperture telescopes at Simons Observatory.

47 OTHER INSTRUMENTATION↗

Development of a DC Distribution Testbed for High-Power EV Charging

This paper explores the design and implementation of a power hardware-in-the-loop (P-HIL) setup for DC distribution infrastructure integrated with high-power charging (HPC) of electric vehicles (EVs), DC loads, and sources. The utilization of DC distribution holds significant potential for enhancing the operation of a HPC station architecture. However, there are challenges establishing a DC charging hub including interoperability, commoditization, distributed energy resource integration, stability, DC protection, and lack of common system level controllers. To address these challenges, a testing setup is required that accommodates commercial off-the-shelf (COTS) products to evaluate different use cases at rated power and voltage levels. The developed P-HIL setup features a dedicated DC charging hub, DC-coupled chargers, DC loads/sources, DC protection, and a communication architecture. The integrated P-HIL system provides a versatile testing environment to address technology and interoperability gaps and implements a smart energy management system (SEMS). This platform enables comprehensive and robust testing of COTS devices, charger prototypes, SEMS controllers and protection schemes, which together will accelerate transition to EVs at scale. The setup is tested for various use-cases at full-scale, integrating 950 V DC bus voltage, 660 kW grid-tied inverter, 150 kW COTS charger, and 100 kW energy storage system within an open-source SEMS platform.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

A recyclable self-healing composite with advanced sensing property

Polymer-based composites frequently encounter damage, often lurking beneath the surface and proving challenges to their early detection and repair. While material-based sensors show promise for encoding self-sensing properties within these composites, their in situ healing and reprocessability remain significant challenges. Therefore, the overarching goal of this study is the creation of a reprocessable polymeric composite encoded with self-healing attributes and the ability to autonomously sense damage. At the core of this innovation are vitrimers, a polymeric material characterized by a covalently adaptive dynamic network responsive to external factors such as heat. They combine thermoset-like resilience with thermoplastic-like flowability on demand under external stimuli. We nanoengineer a polyester-based vitrimeric polymer by incorporating piezoresistive carbon nanotubes (CNTs) as reinforcing elements that not only enhance its mechanical strength but also create a percolation network within the composite, thereby enabling piezoresistive self-sensing properties, all the while preserving the intrinsic self-healing capabilities offered by the vitrimeric matrix. The fabrication process of the composite involves a solvent-free in situ polymerization method that combines epoxy and anhydride-containing monomers with ~ 0.1 wt.% of CNTs. Once it was established that the introduction of CNTs into the polymeric matrix did not compromise the mechanical properties of the composite, their strain-sensing properties were characterized by applying cyclic loading while measuring their electrical resistance. Strikingly, CNT-enhanced vitrimer composite consistently retains its mechanical and sensing properties through repeated cycles of reshaping and reprocessing, underscoring its potential as a robust distributed strain sensor. This polyester-based vitrimeric composite is also easily recyclable without harsh chemical treatments. Preliminary findings from this study conclusively demonstrate that the bulk composite boasts both self-sensing capabilities and in situ detect healing properties, charting a promising course towards the development of a mechanically resilient multifunctional composite that seamlessly integrates selfsensing and healing capabilities.

Rohewal, Sargun Singh↗

POWER DATA PIPELINE

SF-25-081 Utility software for creating high-performance data pipelines to extract, load, and transform raw electric power systems measurements. For use with anomaly detection models training workflows. The software supports the project: Adaptive Cybersecurity for DER: A Game-Theoretic and Machine Learning approach for Real-Time Threat Detection and Mitigation

Plathottam, Silby Jose [Argonne National Laborator↗

National Summary Statistics for Depot-Based Medium- and Heavy-Duty Vehicle Operations

This file provides nationally aggregated summary statistics to characterize the daily operations of medium- and heavy-duty vehicles. It provides typical daily driving distances, domicile dwell durations, and one version of potential normalized electric vehicle depot charging load curves. The methodology to create these data was designed with national representativeness in mind, and the data are suitable for national analysis.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Electrification Futures Study: Scenarios of Power System Evolution and Infrastructure Development for the United States

This report is one in a series of Electrification Futures Study (EFS) publications. The EFS is a multiyear research project to explore potential widespread electrification in the future energy system of the United States. Electrification is defined as the substitution of electricity for direct combustion of non-electricity-based fuels used to provide similar services. The EFS is specifically designed to examine electric technology advancement and adoption for end uses in the major economic sectors of the United States, electricity consumption growth and load profiles, future power system infrastructure development and operations, and economic and environmental implications of electrification. Because of the expansive scope and the multiyear duration of the study, research findings and supporting data will be published as a series of reports, with each report being released on its own time frame.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Emerging Energy Market Analysis Initiative, Methodological Framework

Planning and operations of the electric power sector are undergoing radical changes. Climate change mitigation efforts have forced rapid changes to the technology mix. Technologies like wind and solar have experienced rapid growth, while investment in fossil sources has peaked or is declining. These foundational changes are forcing changes to energy systems. Demand-side adoption of electrified technologies, including electric vehicles, is changing load profiles and opening up new avenues for consumer participation in the power systems. The implications of an evolving power system pertain to more than environmental and technical dimensions. Changes to the generation mix and its consequent upstream and downstream impacts such as fuel production have significant and highly concentrated consequences on economies and employment. Shifts towards distributed (or decentralized) generating assets offer the potential to reshape economic and employment opportunities associated with the energy sector across space and socioeconomic groups. The Emerging Energy Market Analysis (EMA) initiative aims to identify sustainable, regionally acceptable, and high-value energy solutions that are secure and equitable. Unlike short-term, least-cost choices that can narrowly account for traditional options, EMA’s focus on emerging energy markets recognizes that new or adapted practices and technologies can alter the frontier of solutions and advance a community’s social, economic, and natural pathways. Such change requires a more comprehensive analysis of societal input, resources, capabilities, and infrastructure. These considerations lay the foundation for community decision-making models that are responsive to community values as well as the history and drivers. The result is a community-based decision and engagement model that will be valuable to decisionmakers and developers of advanced and emerging energy solutions, seeking a social license to operate prior to project development.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Creation of Laboratory-scale Testbed for Autonomous Monitoring and Control of Subsurface Systems

This report describes the results of an LDRD project aiming to develop a laboratory-scale testbed for autonomous subsurface monitoring and control systems. Modifications were made to an existing polyaxial loading frame to incorporate electrical resistivity tomography (ERT) and acoustic emission (AE) monitoring systems. This allows engineered subsurface processes to be studied under realistic temperatures and stresses in a scaled-down laboratory environment with similar monitoring systems as are deployed in field-scale systems. The paper outlines some challenges that were faced in implementing the ERT system at the laboratory scale and the solutions that were devised. Results are shown from two demonstration tests—one focusing on the ERT system, and one focusing on the AE system.

42 ENGINEERING↗

Grid Planning for Building Electrification: A Report by the Energy Systems Integration Group’s Grid Planning for Building Electrification Task Force

The increased electrification of buildings across the United States is being driven by technical advancements, cost reductions for some building technologies, consumer preferences, and policy goals for decarbonization. However, the effects of this load growth on the electric distribution system are often only a minor consideration in policymaking and long-term planning studies. The long lead time and useful life of power system equipment means that the decisions taken today are expected to support our society well into the 2060s and beyond. Distribution planning stakeholders can take steps today to establish a grid foundation that captures the new challenges presented by building electrification. This report focuses on building electrification for the residential and commercial sectors, focusing most heavily on space heating, as this end use stands to most strongly impact demand.1 Across all end uses, building electrification could require somewhere between 10% and 70% more electricity generation capacity than exists today depending on technology adoption and energy efficiency.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evidence of Completion of Milestone 3: Experimental Testbed

Construction and deployment of the experimental testbed encountered scheduling delays, and completion was subsequently further delayed by curtailment of LANL operations due to the COVID-19 pandemic. Between March and October, LANL was in a state of “Limited Operations” such that only certain “mission-critical” work was performed with approximately 25% on-site staffing. In spite of this, much of the lab space preparation was executed and the five initial model house” units were constructed and installed during this period. Still, the pace of construction was impacted by difficulty in coordinating personnel and minimizing contact between workers. Currently, LANL is in the mode of “Normal Operations with Maximum Telework,” which continues to limit the availability of on-site personnel. Nevertheless, Milestone 3 is now complete. This document describes the experiment as it is deployed and provides status for each task for this milestone.

99 GENERAL AND MISCELLANEOUS↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microgrid Assisted Design for Remote Areas

In this work, we present a three-stage multiobjective mixed-integer linear programming (MILP) for the optimal expansion planning and operation of isolated multienergy microgrids in remote areas. By selecting the optimal distributed generators (DGs) and energy storage systems (ESSs) mix selection, siting, sizing, and scheduling in the remote microgrid, the proposed model is targeted to minimize the annualized total cost of microgrids while enhancing the performance of the system, i.e., minimizing the voltage deviations and line power loss. To represent the electricity and heat flow between generation resources and various electrical, heating, and cooling loads in the isolated microgrid, linearized power flow, and heat flow constraints are employed in the proposed optimization model. The available capacity of DGs and ESSs are modeled as discrete constants instead of continuous variables for practical purpose. Numerical simulation results on a remote microgrid consisting of DGs, ESSs, and various loads validate the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Role of Electric Vehicles in the U.S. Power Sector Transition: A System-Level Perspective

After over a century of petroleum dominance many anticipate that electrification could disrupt the transportation energy landscape. At the same time, the electric power systems are undergoing profound changes: variable renewables are displacing conventional generation sources; distributed generation is disrupting utility business models; energy storage and other new technologies are emerging; and the traditional system based on the premise that generation is dispatched to match an inelastic demand is evolving to create a system with greater participation in power system planning and operations from traditionally passive consumers. In this context, it is important to understand how transportation electrification will impact electricity demand and in turn electricity supply, including changes in the load shapes that characterize the system and the opportunity to leverage flexible electric vehicle (EV) charging to better integrate demand and supply. Assessing the impacts of electrification on the energy system requires an understanding of how it might impact the amount and shape of electricity consumption, and how this electricity can be supplied. In particular, increased adoption of electric vehicles introduces a new source of demand altogether, potentially very flexible. Moreover, electrification could shift the consumption of natural gas between sectors, thereby affecting the economics for natural gas-fired generation relative to other electricity generation options. Several factors will impact the evolution of the power system under a widespread electrified future, which, in turn, could have far-reaching effects on future energy costs and emissions.

47 OTHER INSTRUMENTATION↗

Large-Scale Simulation of Regional Demand Flexibility Implementation and Customer Economic Impact

The Distribution System Operator with Transactive (DSO+T) study conducted a large-scale simulation of over 60,000 customers in a region the size of Texas to demonstrate the effective coordination of distributed energy resources (DERs) in commercial and residential buildings. The integrated simulation included both the bulk (wholesale generation and transmission) and distribution systems. The DERs (including batteries, electric vehicles, air conditioning, and water heaters) participated in a transactive energy retail market that was integrated into an existing competitive wholesale market. The engineering and economic performance of the resulting demand flexibility was evaluated over annual simulations for both moderate and high renewable generation scenarios. A detailed parametric cost model was developed to enable detailed economic analysis of key stakeholders. In addition, fixed and dynamic customer tariffs were designed and applied to the customer population. This allowed the impact on annual customer bills to be analyzed for various building types (residential versus commercial; single- versus multi-family). This paper presents results showing the relative flexibility of batteries, electric vehicles, and building loads throughout the year and under different renewable scenarios. This feeds a detailed breakdown of the impact this flexibility has on the operating costs of the grid and the resulting net economic benefit. Finally, the study showed that practically all customer classes (including non-participating customers) save money under the proposed demand flexibility scheme. The study found overall net annual economic savings of $3.3-5.0B for a region the size of Texas equating to average customer bill savings of 10-16%.

Reeve, Hayden M.↗