Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “dynamic thermal performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Single-Layer Dititanium Oxide Ti 2 O MOene: Multifunctional Promises for Electride, Anode Materials, and Superconductor

Using the first-principles calculations, we report the existence of the single-layer (SL) dititanium oxide Ti 2 O (labeled as MOene) that constructs a novel family of MXene based on transition-metal oxides. This MOene material strongly contrasts the conventional ones consisting of transition-metal carbides and/or nitrides. SL Ti 2 O has high thermal and dynamical stabilities because of the strong Ti–O ionic bonding interactions. Moreover, this material is an intrinsic electride and exhibits extremely low diffusion barriers of ~12.0 and 6.3 meV for Li and Na diffusion, respectively. When applied as anode materials in lithium-ion batteries and sodium-ion batteries, it possesses a high energy storage capacity (960.23 mAhg –1 ), surpassing the traditional MXenes-based anodes. The superb electrochemical performance stems from the existing anionic electron on Ti 2 O surface. Astonishingly, SL Ti 2 O is also determined to be a superconductor with a superconducting transition temperature (T c ) of ~9.8 K, which originates from the soft-mode of the first acoustic phonon branch and enhanced electron–phonon coupling in the low-frequency region. Furthermore, this soft-mode behaves much softer upon applying a compressive strain of 2%, leading to a higher T c of 11.9 K. Furthermore, our finding broadens the family of MXenes and could facilitate more experimental efforts toward future nanodevices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Modeling of Supercritical CO2 Shell-and-Tube Heat Exchangers Under Extreme Conditions: Part II: Heat Exchanger Model

Abstract Heat exchangers play a critical role in supercritical CO2 Brayton cycles by providing necessary waste heat recovery. Supercritical CO2 thermal cycles potentially achieve higher energy density and thermal efficiency operating at elevated temperatures and pressures. Accurate and computationally efficient estimation of heat exchanger performance metrics at these conditions is important for the design and optimization of sCO2 systems and thermal cycles. In this paper (Part II), a computationally efficient and accurate numerical model is developed to predict the performance of shell-and-tube heat exchangers (STHXs). Highly accurate correlations reported in Part I of this study are utilized to improve the accuracy of performance predictions, and the concept of volume averaging is used to abstract the geometry and reduce computation time. The numerical model is validated by comparison with computational fluid dynamics (CFD) simulations and provides high accuracy and significantly lower computation time compared to existing numerical models. A preliminary optimization study is conducted and the advantage of using supercritical CO2 as a working fluid for energy systems is demonstrated.

Engineering↗

Commercial building HVAC demand flexibility with model predictive control: Field demonstration and literature insights

Model Predictive Control (MPC) for building Heating Ventilation and Air Conditioning (HVAC) systems is beginning to gain traction in the market, with a few controls companies incorporating it into their product offerings. However, it remains difficult to assess whether the energy cost savings are enough to justify the cost of MPC implementation for a particular building, given the limited number of reported demonstrations. For small commercial and residential buildings with relatively uniform systems, standardized approaches can help lower implementation costs. In contrast, for large buildings or district systems, the potential magnitude of cost savings could justify more customized solutions. Estimating the cost-effectiveness of MPC becomes more challenging for medium and large commercial buildings, where a one-size-fits-all solution may not be suitable, and the potential energy cost savings may be insufficient to justify a customized solution. To make MPC technology more appealing, incorporating additional value streams beyond energy efficiency alone can significantly increase its attractiveness. One such revenue stream is demand flexibility, in response to dynamic electricity prices, where MPC can leverage the thermal mass of the building to shift the load and support the grid. Building on an extensive literature review of MPC field studies focused on cost savings and demand flexibility, this paper presents the results of implementing MPC control in a large office building HVAC system in Berkeley, CA. Four different dynamic electricity price profiles were integrated into the MPC objective function to shift building demand while maintaining comfort, and field testing was performed with each price profile across four seasons. The results show potential for 40–65 % demand decrease percentage and up to 61 % annual cost savings compared to the existing rule-based control strategy, under the tested dynamic price scenarios. This paper also presents a sensitivity analysis on the cost savings with respect to the price profile variability, discusses the implementation effort for the price-responsive MPC, and compares the cost savings found in this study to those found in literature on the basis of dynamic price variability, or so-called Electricity Price Relative Standard Deviation.

Zanetti, Ettore↗

Atomistic insights into the synergistic effects of tensile strain and hydroxyl group on increasing the thermal conductivity of monohydric alcohols as latent heat storage materials

The low thermal conductivity of linear monohydric alcohols significantly limits their performance when used as latent heat storage materials. It was found that imposing certain mechanical strains on nanomaterials with highly ordered structures can lead to appreciable thermal conductivity enhancement. To explore the potential of enhancing the intrinsic thermal conductivity of monohydric alcohols, a simplified ideal crystal model was employed for molecular arrangement in this work. The variation of atomistic heat transfer as a function of tensile strains was exploited by non-equilibrium molecular dynamics simulations. Furthermore, the influence of stretching on the vibration density of states and the corresponding molecular morphology were revealed. The results suggested that the thermal conductivity of monohydric alcohols with such simplified ideal crystalline structures can increase by about 170 % at the strain of 0.1. The distance between neighboring interfaces was found to determine the energy of inter-molecular interactions at the crystal grain boundaries. The hydrogen bonds energy has not reached the critical value when increasing tensile strains from 0 to 0.1. In contrast, the strongest van der Walls interactions for alkanes were obtained at the strain of 0.06 where the interfacial distances of alkanes have achieved their equilibrium distances. In addition, the interfacial heat transfer coefficient of ideal crystal monohydric alcohols at hydroxyl interfaces was found to be threefold than that between methyl interfaces, in consistent with the strength of inter-molecular interactions between functional groups at the interfaces.

36 MATERIALS SCIENCE↗

Explicit simulation of the Brownian rotation of arbitrary shaped aerosol particles using quaternions

The shape of an aerosol particle strongly influences its mass and momentum transfer cross-sections, charging properties, and other physical properties. Here, we present an explicit time-stepping procedure to simulate the rotational Brownian motion of arbitrary shaped aerosol particles by solving Euler’s equation of rotation. A Langevin formulation of the rotation equations is used, wherein Brownian motion due to thermal collisions between a particle and background gas molecules is represented using a stochastic fluctuating torque and fluid resistance is included as a drag torque. To avoid singularities associated with describing the orientation of a shape with Euler angles, we employ a quaternion formulation that leads to first-order stochastic differential equations to describe the evolution of the angular position and angular velocity of a rigid body. We perform all the rotational dynamics calculations in the body-fixed frame of reference attached to the rotating shape whose basis vectors are the normalized eigenvectors of the inertia tensor of the particle. Numerical solutions to rotation under torque-free conditions, damped rotation without Brownian motion, and stochastic rotation for arbitrary shapes are presented and discussed. The presented method enables time-resolved simulation of Brownian rotation for direct comparison with experimentally measured trajectories or statistical measures. The second order accuracy of the used time-stepping procedure places a severe restriction on the timestep that can be used for obtaining accurate results. Animations of presented simulations are included for visualizing rotational motion at various gas pressures. To aid implementation, MATLAB ® codes are also provided. Extension to include translation Brownian motion is straightforward.

Roy, Mrittika↗

Responses of Boreal Forest Ecosystems and Permafrost to Climate Change and Disturbances: A Modeling Perspective

The north circumpolar region contains a large amount of carbon. This carbon storage is vulnerable due to permafrost degradation and wildfire disturbances under ongoing and projected climate change. Climate warming and wildfires change soil organic horizons gradually or abruptly, and modify permafrost thermal-hydrology and biogeochemistry, ecosystem structures, functions, and capability of sequestrating rising atmospheric CO2. Land models do not fully take accounts of these interactions and its complexity in the high latitude. This chapter describes a terrestrial ecosystem model with dynamic organic soil module (DOS-TEM) and its unique freezing-thawing algorithm, and presents key results of its applications mainly in boreal forests of Alaska. The DOS-TEM explicitly considers interactions of soil thermal and hydrological processes, permafrost degradation and the direct and indirect effects of wildfire disturbances, in addition to soil–plant C and N cycles. We first introduce four modules of DOS-TEM, focusing on its disturbance module and coupling with a dynamic organic soil module. Then we describe and validate DOS-TEM’s freezing-thawing algorithm and development based on two-directional Stefan algorithm (TDSA). Finally, we apply the DOS-TEM at site and region scales, with a focus on model ability to dynamically simulate soil organic thickness under warming and wildfires, and consequent impacts on permafrost in the Yukon River Basin. We conclude that land surface model development is urgently needed to include other critical landscape processes, such as thermalkarst and other disturbances, to synchronize thermal-hydrological-biogeochemical processes, and to incorporate an advanced understanding of biospheric feedbacks to atmosphere and ecosystems. Such a complexity of modeling scope is plausible with advancement of high performance computing.

Yi, Shuhua↗

Phase-field modeling and experiments of dynamic fracture in single crystal quartz

Predicting the onset and characteristics of brittle fracture is important for a wide range of engineering and geological material applications. In this paper, we study important aspects of brittle fracture in α-quartz by phase-field modeling and experiments using a top-down approach. In the modeling framework, the work term in the Griffith energy balance is replaced with internal energy contributions that represent surface energy, thermal energy, and elastic strain energy stored in defects. This allows parametrization of individual energy contributions in terms of internal state variables and keeps track of energy partitioning after the onset of fracture. The path and history dependence of fracture is included in evolution laws for internal state variables, e.g., entropy evolution, while the energy remains a true potential. In the experimental part, dynamic compression experiments coupled with X-ray phase contrast imaging are performed on cube-like samples with a hole. In the top-down analysis, dynamic compression and three point bending experiments from the literature are simulated with the developed phase-field damage model. In conclusion, the fitted model highlights the strain rate, size, and stress state dependence of damage nucleation and evolution in single crystal α-quartz.

36 MATERIALS SCIENCE↗

High-Pressure Equation of State of 1,3,5-triamino-2,4,6-trinitrobenzene: Insights into the Monoclinic Phase Transition, Hydrogen Bonding, and Anharmonicity

The high-pressure equation of state (EOS) of energetic materials (EMs) is important for continuum and mesoscale models of detonation performance and initiation safety. Additionally, obtaining a high-fidelity EOS of the insensitive EM 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) has proven to be difficult because of challenges in experimental characterization at high pressures (HPs). In this work, powder X-ray diffraction patterns were fitted using the recently discovered monoclinic I2/a phase above 4 GPa, which shows that TATB is less compressible than when indexed with the triclinic $P\bar{1}$ phase. First-principles calculations were performed with Perdew–Burke–Ernzerhof (PBE) and PBE0 functionals including thermal effects using the $P\bar{1}$ phase. PBE0 improves the description of hydrogen bonding and thus predicts accurate planar a and b lattice parameters under ambient conditions. However, discrepancies in the predicted lattice parameters above 4–10 GPa compared with experimental measurements indexed with $P\bar{1}$ are further evidence of a structural modification at high pressure. Layer sliding defects are formed during molecular dynamics simulations, which induces an anharmonic effect on the thermal expansion of the c lattice parameter. In short, the results provide several insights into determining high-fidelity EOS parameters for TATB and other molecular crystals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3-D Prismatic Packaging Methodologies for Wide Band Gap Power Electronics Modules

In a power module the parasitic inductance limits the dynamic high-frequency performance, and the area of the cooling surfaces limits the power capability. This paper presents a new 3D power electronic design methodology based on the concept of mutual inductance cancellation and multi-sided heat transfer. New 3D prismatic packaging concepts are proposed for Wide Band Gap (WBG) power devices, where the devices can be mounted at acute angles to adjacent interconnects or other devices. Discussion is given on electrical and thermal path optimization in a 3D space. To validate the 3D prismatic packaging methodology, a 1200V/50A SiC half-bridge power module is fabricated and tested for electrical and thermal performance and results are compared with simulations. The power density calculated for the module is 12 kW/in3 (including heatsink) and shows a 31.3% inductance reduction compared to a 2D planar module. Finally, design guidance suggested for utilizing prismatic structures is provided, together with suggested future work in the area. This paper presents the first reported true 3D power module.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Optimization of Annealing for WZ-Phase Removal and Densification in Sb-Doped CdSexTe1-x Solar Cells

The impact of high temperature annealing (HTA) treatments on the performance of Sb-doped CdSeTe solar cells containing a CdSe0.25Te0.75/CdTe front stack and a vapor transport (VT) deposited CdTe:Sb absorber was studied. The HTA treatment of the thermally evaporated CdSe0.25Te0.75/CdTe front stack converts the mixed-phase film into a single zinc blende structure through recrystallization of the photo-inactive wurtzite phase. Subsequently, HTA treatment of the full device stack after vapor transport deposition of CdTe:Sb absorber promotes Se-Te intermixing, reduces voids, densifies the full stack and enhances CdTe:Sb grain growth. Comprehensive characterizations revealed that the combined HTA treatments significantly improved film crystallinity, removed the WZ phase in the front stack, enhanced full-stack densification, reduced defect densities, and enhanced carrier dynamics. With HTA treatments, the open-circuit voltage (VOC) of CdSeTe:Sb devices increased from ~ 400 mV to >= 600 mV, and when combined with optimized CdCl2 treatment, VOC reached 849 mV. The net carrier concentrations (NA-ND) of representative devices were NA-ND = 1.5 x 10^15, 1.1 x 10^15, and 3.5 x 10^14 cm-3 for the no-HTA, moderate-HTA, and optimized high-VOC conditions, respectively. Since the highest VOC corresponds to the lowest apparent NA-ND, , which is similar to a Cu-doped-only CdSeTe solar cell (NA-ND ~= 2 x 10^14 cm-3), the data indicate that improved device performance does not result from increased electrically active Sb; instead, it points to structural improvement as the dominant effect of HTA. The findings demonstrate the potential of HTA treatments to improve the structural and electrical properties of CdSeXTe1-X solar cells.

14 SOLAR ENERGY↗

Covalent adaptable networks for electrolyte–binder integration in recyclable lithium metal batteries

Lithium-metal batteries (LMBs) are considered a promising next-generation energy storage technology due to their exceptionally high energy density. However, the development of solid polymer electrolytes and cathode binders for LMBs faces critical challenges, including interfacial instability, poor recyclability, and growing environmental concerns. In particular, current systems often rely on non-recyclable components featuring permanently crosslinked networks and polyfluoroalkyl substances (PFAS), such as poly(vinylidene fluoride) (PVDF), which cause battery waste and environmental harm. Herein, we introduce a multifunctional covalent adaptable network (CAN) platform based on thermally reversible Diels–Alder (DA) chemistry, designed for dual functionality as a CAN-based electrolyte (CAE) and a CAN-based cathode binder. The CAE achieves high ionic conductivity and strong storage modulus (1.4 mS cm −1 and ∼ 10 5 Pa at room temperature, respectively) and enables stable long-term cycling in symmetric Li||Li cells for over 2000 h with low overpotential. When it is applied as a cathode binder in LiFePO 4 (LFP) composite electrodes (C-LFP), the CAN matrix significantly reduces interfacial resistance and enhances discharge capacity compared to conventional PVDF-based systems. Thermal treatment induces self-healing at the cathode–electrolyte interface, further improving contact and yielding a discharge capacity of 150 mAh g −1 at 0.5 C. Moreover, the dynamic CAN architecture allows efficient recovery and reuse of lithium salts from spent electrolytes through retro-DA reactions under mild conditions (∼80 °C), establishing a low-energy, cost-effective recycling pathway. In conclusion, this work presents a scalable and sustainable strategy for high-performance LMBs by integrating recyclability, interfacial healing, and PFAS-free design, offering a holistic solution aligned with circular economy principles and next-generation battery demands.

Diels–Alder↗

What are the Impacts on the HVAC System when it Provides Frequency Regulation? – A Comprehensive Case Study with a Multi-Zone Variable Air Volume (VAV) System

Heating, ventilation, and air-conditioning (HVAC) systems in commercial buildings have proven to be a great asset for providing secondary frequency regulation (FR) service to the power grid. However, how the provision of FR service affects the HVAC system Quality of Service (QOS) is still largely unknown. In particular, there exists a controversy regarding the energy efficiency impact. This paper investigates how a HVAC system performance and its associated controls are impacted during and after the FR service. For the assessment, we developed a dynamic Modelica-based medium office building model as a virtual testbed with the Air Handling Unit (AHU) fans providing the FR service. Different regulation capacities (demand levels) and standard test signals under various load profiles in the U.S. are considered. The results show that FR has little or no impact on the HVAC operation and occupant thermal comfort while the building is providing the service if an appropriate regulation capacity is pre-determined. However, if the regulation capacity is overestimated, the quality of the FR service provided by the HVAC system and the HVAC energy efficiency will be affected due to the equipment operating constraints. In addition, the AHU supply air temperature fluctuates, and the controller cannot maintain the desired setpoint as the FR magnitude is increased. After the FR service time, the system takes a certain period to return to normal operation. The recovery period extends with the increase in the FR magnitude. For this case study, there exists a control conflict between the FR control and the existing HVAC control (from ASHRAE Guideline 36-2018) during high load conditions, causing the fan speed to saturate. The fan power consumption could increase significantly; up to 77% increase compared to the baseline was observed. This case study demonstrates that the HVAC system controls need to be enhanced and adapted to minimize the interaction between the FR controller and the indoor environmental controls in order to preserve the HVAC system QOS while (during and after) providing satisfactory FR service.

Lu, Xing↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Machine learning prediction on the fractional free volume of polymer membranes

Fractional free volume (FFV) characterizes the microstructural level features of polymers and affects their properties including thermal, mechanical, and separation performance. Experimental measurements and theoretical analyses have been used to quantify the FFV of polymers, but challenges remain because of their limitations. Experimental measurements are laborious and based on semi empirical equations, while Bondi’s group contribution theory involves ambiguities like the determination of van der Waals volume and the choice of factor values in the theoretical equation. To efficiently evaluate the FFV of polymers, this study utilizes high-throughput molecular dynamics (MD) simulations to build a large dataset regarding polymer’s FFV. Based on this large dataset, we further build machine learning (ML) models to establish the composition-structure relation. Inspired by group contribution theory which correlates polymer’s functional groups to FFV, our ML models correlate polymer’s substructures or physico-chemical indexes to FFV. Here, our study first benchmarks the MD simulation protocol to obtain reliable FFV of polymers and then carries out high-throughput MD simulations for more than 6,500 homopolymers and 1,400 polyamides. Such a large and diverse dataset makes the well-trained ML models more generalizable, compared with the group contribution theory. The efficiency of a feed forward neural network model is further demonstrated by applying it to a hypothetical polyimide dataset of more than 8 million chemical structures. The predicted FFVs of hypothetical polyimides are further validated by MD simulations. The obtained FFVs of the 8 million polymers, plus their previously reported gas separation performances, demonstrate the promising capability of ML virtual screening for the discovery of polymer membranes with exceptional permeability/selectivity.

36 MATERIALS SCIENCE↗

Development of Conceptual Lead Cartridge Design to Perform Irradiation Experiments in VTR

This paper seeks to introduce the latest design of the Extended Length Test Assembly–Cartridge Lead (ELTA-CL) with associated thermal-hydraulic (TH) assessment and related experiment activities to support the critical component development performed by the ELTA-CL team (Los Alamos National Laboratory, Westinghouse Electric Company, and the University of New Mexico). The goal of the ELTA-CL program is to develop and validate an experimental capability to perform irradiation experiments in the Versatile Test Reactor (VTR) addressing Lead Fast Reactor (LFR) technology gaps, in support of the commercial development of advanced lead-cooled fast reactor concepts. Through a design maturation process and parametric study, a conceptual design is proposed to meet the requirements for material and corrosion testing. Thermal-hydraulic characteristics for the conceptual design at desired operating conditions are assessed with systems-level (one-dimensional) and computational fluid dynamics (three-dimensional) simulations. Along with the conceptual design work, experimental activities for the development of critical components such as the pump and flowmeter are undertaken. From both the modeling study and the experimental results, the design requirements of the Phase 1 ELTA-CL (e.g., 500°C and 2 m/s) are achievable with the current conceptual design. Additional design improvements and safety assessments at both steady-state and transient conditions for the final ELTA-CL design will be pursued.

42 ENGINEERING↗

Physical Sciences Vistas (Issue 3 2020)

In this issue, highlights of our outstanding R&D supporting the Laboratory’s nuclear security mission include the following. 1. The essential nuclear materials science contributions of MST’s Materials Properties Team to a range of Lab missions, operations, and initiatives. 2. Work in the Sigma Complex supporting NNSA’s Advanced Manufacturing Development milestones by members of Sigma Division and colleagues across the Laboratory and other NNSA sites. 3. Greg Dale’s role in the Lab’s molybdenum program and today as a technical lead on the Scorpius project. 4. Measurements that reveal the role thermal interfaces play in dynamic compression experiments. 5. The first-ever synthesis of an actinide framework, which offers opportunities for understanding these structures as potential radioactive waste forms and provides new models of actinide species transport in the environment. This issue also showcases, as part of our commitment to simultaneous excellence in mission operations and community relations, the successful high-hazard repair of the LANSCE accelerator, which resulted in a large team Laboratory Distinguished Performance Award, and a virtual Summer Physics Camp for Young Women that brought together participants from around the world, even as COVID kept them socially distant in their homes.

36 MATERIALS SCIENCE↗

A Survey of Multizone Airflow Simulation Software

H-Canyon simulates the building and process ventilation to ensure positive contamination control for any modifications as well as evaluating off-normal conditions. Simulations can also be used to identify air quality of personnel occupied areas. The models can be classified into two groups, single and multi-zone models. As the name states, a single zone model assumes that the building can be described by a single, well-mixed zone. Whereas large buildings have structures that must be described as multizone. Multizone airflow models deal with the difficulty of flows in a building by distinguishing the effects of internal flow restrictions. Several models have been developed that take internal partitions into account. CONTAM (currently used) is a multizone airflow program created by NIST to determine airflows including infiltration, exfiltration, wind pressures acting outside the building, buoyancy effects caused by the indoor and outdoor air temperature difference. COMIS is a multizone air infiltration, ventilation, and contaminant transport model that was developed at Lawrence Berkeley National Laboratory. COMIS deals with applied pressure distribution, airflow components, HVAC systems, schedules, and contaminant transport. EnergyPlus is designed by DOE. It supports flexible component level configuration of HVAC models and simulates sub-hourly time steps to control fast dynamic systems. The program features include providing accurate environmental performance data including energy consumption and carbon emissions, and reporting solar gains on surfaces. Heavent is used to model industrial ventilation systems to control airborne contaminants. It's designed based on the American Conference of Governmental Industrial Hygienists (ACGIH) Ventilation manual. DesignBuilder is the most recognized and advanced user interface to EnergyPlus. It gives access to all of the most frequently required simulation capabilities covering building fabric, thermal mass, glazing, shading renewables, and HVAC analysis. The objective of this study is to identify all relevant software available including commercially licensed, freely licensed, and open source, that can be used to simulate large, complex process facility ventilation systems. All discovered software tools are evaluated for salient features and compared to the software tool currently used to simulate the H-Canyon ventilation system. The design criteria of a ventilation system has two basic requirements: Supplying fresh air for the occupants and changing the air in the room sufficiently; therefore, the smells, fumes, and contaminants will be removed. In this study, first, whether the software simulates airflow (infiltration, natural ventilation, and interzonal) or considers them to be inputs is discussed. Second, if indoor contaminant levels are considered; and finally suggestions on how airflow analysis can be more appropriately accounted for when performing airflow simulation of a building. All of the airflow software reviewed for this study can account for constant infiltration and natural ventilation rates that are not affected by changes in indoor and outdoor conditions. Modelling infiltration in EnergyPlus or DesignBuilder are applicable for small buildings and not appropriate for larger buildings like the H-Canyon. The effect of wind on external pressures, infiltration, and natural and mechanical ventilation, can also be calculated using all of these software. These programs have control options to switch between natural to mechanical ventilation modes or both (hybrid). Interzonal airflow can be applied which means one zone can be specified to receive a fixed amount of air from another zone. The following ventilation modeling software is recommended for further testing: CONTAM, COMIS, Heavent. The next step in evaluating the software will consist of creating test facility simulations using evaluation copies of the software.

42 ENGINEERING↗

Performance assessment of active insulation systems in residential buildings for energy savings and peak demand reduction

Active insulation systems (AISs) in buildings are envelopes that integrate thermal insulation, thermal energy storage, and controls. Although different designs for AISs have been proposed in the literature, a comprehensive analysis of feasible AISs is lacking. This paper discusses the energy performance, peak demand reduction potential, and performance characteristics of an AIS that uses a concrete wall as thermal mass sandwiched between two solid-state thermal switches (STSs). These STSs change their thermal conductivity using an on/off metal switch to create or break a thermal bridge across the STS. This paper first describes the experimental setup, used to determine the ratio of thermal resistance during R-high (low thermal conductivity) and R-low (high thermal conductivity) states of the STSs. This ratio was then used in whole-building energy simulations to evaluate the performance of AIS walls across different climate zones with/without a freeze timer of 60 min. The timer was added to reduce the number of switches of STSs from one state to another, and hence the energy needed for these switches. Analysis of the switching frequency and interval of STSs, thermal conductivity of walls, impact of wall orientation, and heat transfer through the wall from the use of AIS at different climate zones/locations were performed. The simulation results show that the AIS can achieve energy savings ranging from ~980 to 2,290 kWh in a single-family home with a floor area of ~220 m 2 compared with an IECC 2018 baseline. We found the energy savings was higher in dry climate zones which represent 17% of residential buildings in the United States, compared to humid or marine climate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗