Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “device characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 469 records · Page 26

Component Characterization of an eVTOL Reference Model for Crashworthiness Studies

Researchers at the National Aeronautics and Space Administration (NASA) Langley Research Center (LaRC) have conducted a series of structural component and seat level tests to improve finite element model (FEM) characterization of a representative vertical take-off and landing (eVTOL) test article developed by NASA. A full-scale dynamic test was conducted on the representative eVTOL test article in November of 2022. The test article represented a high wing, six passenger eVTOL design concept and is referred to as the lift plus cruise (LPC) test article. The full-scale test identified limitations in the analytical models used to predict aircraft structural response, in particular the composite material models did not effectively capture brittle failure of the structure which were measured during dynamic loading. To better understand the mechanism behind the composite material failure mechanisms observed and to improve the FEM, intact sample specimens of the composite airframe structure were recovered from the test article post-test and used in material characterization testing. In addition, the seat configurations used in the LPC test article were further studied using isolated seat and anthropomorphic test device (ATD) drop tower testing. Dynamic compression tests and three-point bend tests, conducted at varied impact speeds, were performed on the recovered frame section specimens. Additional testing was conducted to characterize the material properties of the forming foam, which remained in the frames after fabrication. These tests were used to improve characterization of the damage and failure parameters of the composite material model used in the FE model of the LPC test article. Seat level tests were conducted on the seats used in the LPC test article using acceleration pulses inclusive of current general aviation and rotorcraft certification load levels as well as conditions representative of those measured at the seat base during the LPC test. The structural material models and seat environment models of the LPC test article FEM were calibrated using the generated component test data. The updates made to these models were then integrated into the LPC FEM and simulated in the full-scale test condition. Results demonstrated the effectiveness of component testing to improve predictive capability of composite aerospace structural models within the crash and dynamic loading environments. Demonstration of the LPC FEM response across an accumulation of coupon, component, seat environment, and full-scale test levels provides confidence in the predictive capability of this model for future use in the study of occupant safety within eVTOL relevant crash environments.

Craswhorthiness↗

Negative Avalanche Feedback Detectors for Photon-Counting Optical Communications

Negative Avalanche Feedback photon counting detectors with near-infrared spectral sensitivity offer an alternative to conventional Geiger mode avalanche photodiode or phototube detectors for free space communications links at 1 and 1.55 microns. These devices demonstrate linear mode photon counting without requiring any external reset circuitry and may even be operated at room temperature. We have now characterized the detection efficiency, dark count rate, after-pulsing, and single photon jitter for three variants of this new detector class, as well as operated these uniquely simple to use devices in actual photon starved free space optical communications links.

single photon detector↗

NEPP Processor Enclave: Testing Artificial Intelligence & Machine Learning

Computational device families are converging and multiple EEE components are required for a complete HPC subsystem. The components of this “processor enclave” are sensitive to radiation effects and therefore must be characterized for mission assurance. NEPP’s standardized approach to testing the Processor Enclave includes math, graphics, and AI and Machine Learning test vectors and device hardware capable of these applications.

Radiation testing↗

Virtex-4VQ dynamic and mitigated single event upset characterization summary

This report is the result of funding by the NASA Electronic Parts and Packaging Program (NEPP) and the combined efforts of members within the Xilinx Radiation Test Consortium (XRTC), sometimes known as the Xilinx Single Event Effects (SEE) Test Consortium. The XRTC is a voluntary association of aerospace entities, including leading aerospace companies, universitie and national laboratories, combining resources to characterize reconfigurable, field programmable gate arrays (FPGAs) for aerospace applications. Previous publications of Virtex-4 radiation results are for commercial (non-epitaxial) devices; see, for example, Refs. 1–5. A notable exception is Ref. 6, which presents XRTC upset measurements of storage elements in the PowerPC405s in the XQR4VFX60. This work represents a continuation of the efforts reported in the “Virtex-4QV Static SEU Characterization Summary” [7]. The contents of this report describe various Single Event Functional Interrupt (SEFI) and Single Event Upset (SEU) modes seen while dynamically exercising the clocked resources within Virtex-4 devices and the corresponding mitigation techniques related to the aforementioned observed SEFI modes.

Allen, Gregory↗

A high temperature testing system for ceramic composites

Ceramic composites are presently being developed for high temperature use in heat engine and space power system applications. The operating temperature range is expected to be 1090 to 1650 C (2000 F to 3000 F). Very little material data is available at these temperatures and, therefore, it is desirable to thoroughly characterize the basic unidirectional fiber reinforced ceramic composite. This includes testing mainly for mechanical material properties at high temperatures. The proper conduct of such characterization tests requires the development of a tensile testing system includes unique gripping, heating, and strain measuring devices which require special considerations. The system also requires an optimized specimen shape. The purpose of this paper is to review various techniques for measuring displacements or strains, preferably at elevated temperatures. Due to current equipment limitations it is assumed that the specimen is to be tested at a temperature of 1430 C (2600F) in an oxidizing atmosphere. For the most part, previous high temperature material characterization tests, such as flexure and tensile tests, have been performed in inert atmospheres. Due to the harsh environment in which the ceramic specimen is to be tested, many conventional strain measuring techniques can not be applied. Initially a brief description of the more commonly used mechanical strain measuring techniques is given. Major advantages and disadvantages with their application to high temperature tensile testing of ceramic composites are discussed. Next, a general overview is given for various optical techniques. Advantages and disadvantages which are common to these techniques are noted. The optical methods for measuring strain or displacement are categorized into two sections. These include real-time techniques. Finally, an optical technique which offers optimum performance with the high temperature tensile testing of ceramic composites is recommended.

Hemann, John↗

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗

Characteristics of AlGaAs/GaAs multiple quantum well infrared detectors

Researchers fabricated and characterized several AlGaAs/GaAs multiple quantum well infrared detectors to evaluate the ultimate performance of these devices for low infrared background applications. The detectors were designed to have a single bound state in the quantum well and the first excited state in the continuum above the AlGaAs conduction band edge. The difference in energy between the two levels, as determined by the quantum well width and aluminum mole fraction in the barrier, was chosen such that peak absorption would occur near 8 microns. The initial structures studied comprised 50 periods with 40 A well widths and 300 A Al(0.28)Ga(0.72)As barriers. The performance of these detectors are summarized. To better interpret these results and design optimized detectors, researchers modeled both the detector noise and tunneling currents. The noise model correctly predicts that multiple quantum well detectors will, indeed, exhibit noise lower than full shot noise. The tunneling current model predicts the dark current versus bias for any choice of design parameters in a multiple quantum well detector. This model predicts a substantially reduced dark current (x 10(exp 04)) for samples with 400 A barriers. To evaluate structures with thicker barriers, researchers fabricated and characterized detectors with 400 A and 500 A barriers; a comparison of detector dark currents is shown. These results are consistent with the predictions of the dark current model.

Janousek, Bruce K.↗

Electrode materials for charge coupled devices

The use of polycrystalline silicon in charged coupled semiconductor devices is discussed. In particular, the electrical and optical properties of the material are characterized.

Gajda, W. T. J.↗

Modelling switching-time effects in high-frequency power conditioning networks

Power transistor networks which switch large currents in highly inductive environments are beginning to find application in the hundred kilohertz switching frequency range. Recent developments in the fabrication of metal-oxide-semiconductor field-effect transistors in the power device category have enhanced the movement toward higher switching frequencies. Models for switching devices and of the circuits in which they are imbedded are required to properly characterize the mechanisms responsible for turning on and turning off effects. Easily interpreted results in the form of oscilloscope-like plots assist in understanding the effects of parametric studies using topology oriented computer-aided analysis methods.

Owen, H. A.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratory test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Detector arrays for low-background space infrared astronomy

The status of development and characterization tests of integrated infrared detector array technology for astronomy applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, with hybrid silicon multiplexers. Laboratary test results and successful astronomy imagery have established the usefulness of integrated arrays in low-background astronomy applications.

Mccreight, C. R.↗

Recent developments on a 128 x 128 indium antimonide/FET switch hybrid imager for low-background applications

By combining high-quality mesa photovoltaic indium antimonide detector material with a silicon x-y FET switch multiplexer, a useful infrared area detector has been developed. This device is intended for low-background applications, where high sensitivity is required. Initial characterization of the detector at 80 K showed a KTC limited read noise of less than 1000 electrons, good dark current, responsivity uniformity, and a maximum readout rate of 10 MHz. The hybrid mating technology has sufficient precision to allow expansion to a 256 x 256 format. The dark current in the detector material is sufficiently low to allow full-frame integration, even with arrays as large as 256 x 256 elements.

Bailey, Gary C.↗

Low-background detector arrays for infrared astronomy

The status of a program which develops and characterizes integrated infrared (IR) detector array technology for space astronomical applications is described. The devices under development include intrinsic, extrinsic silicon, and extrinsic germanium detectors, coupled to silicon readout electronics. Low-background laboratory test results include measurements of responsivity, noise, dark current, temporal response, and the effects of gamma-radiation. In addition, successful astronomical imagery has been obtained on some arrays from this program. These two aspects of the development combine to demonstrate the strong potential for integrated array technology for IR space astronomy.

Mccreight, C. R.↗

Development of an electrostatic propulsion engine using sub-micron powders as the reaction mass

Asteroid sample return missions would benefit from development of an improved rocket engine. Chemical rockets achieve their large thrust with high mass consumption rate (dm/dt) but low exhaust velocity; therefore, a large fraction of their total mass is fuel. Present day ion thrusters are characterized by high exhaust velocity, but low dm/dt; thus, they are inherently low thrust devices. However, their high exhausy velocity is poorly matched to typical mission requirements and therefore, wastes energy. A better match would be intermediate between the two forms of propulsion. This could be achieved by electrostatically accelerating solid powder grains, raising the possibility that interplanetary material could be processed to use as reaction mass. An experiment to study the charging properties of sub-micron sized powder grains is described. If a suitable material can be identified, then it could be used as the reaction mass in an electrostatic propulsion engine. The experiment employs a time of flight measurement to determine the exhaust velocity (v) of various negatively charged powder grains that were charged and accelerated in a simple device. The purpose is to determine the charge to mass ratio that can be sustained for various substances. In order to be competitive with present day ion thrusters, a specific impulse (v/g) of 3000 to 5000 seconds is required. Preliminary results are presented. More speculatively, there are some mission profiles that would benefit from collection of reaction mass at the remote asteroid site. Experiments that examine the generation of sub-micron clusters by electrostatic self-disruption of geologically derived material are planned.

Herbert, F.↗

Evaluation of advanced microelectronics for inclusion in MIL-STD-975

The approach taken by NASA and JPL (Jet Propulsion Laboratory) in the development of a MIL-STD-975 section which contains advanced technology such as Large Scale Integration and Very Large Scale Integration (LSI/VLSI) microelectronic devices is described. The parts listed in this section are recommended as satisfactory for NASA flight applications, in the absence of alternate qualified devices, based on satisfactory results of a vendor capability audit, the availability of sufficient characterization and reliability data from the manufacturers and users and negotiated detail procurement specifications. The criteria used in the selection and evaluation of the vendors and candidate parts, the preparation of procurement specifications, and the status of this activity are discussed.

Scott, W. Richard↗

Pulsed, gridded electron reversal ionizer

The design and performance of a new-type source of negative ions is presented. This device retains the idea of the so-called reversal electron attachment detector to produce low-energy electrons by reversing electron trajectories at an electrode. Electrons are produced in the present device by several ribbon filaments that surround a cylindrical wire grid. They are accelerated through the grid, then decelerated to zero or near-zero velocity at the surface of a tube. The tube (anode) is perforated with small holes through which effuse the target molecules. Electrons attach to form either parent and/or fragment negative ions. Attachment takes place at a location above the anode corresponding to a match between the electron energy and the attachment resonance energy. Negative ions are pulsed out of the attachment region and focused onto the entrance plane of a quadrupole mass selector. Electron and ion trajectory calculations are presented and the performance illustrated with six molecules having attachment resonances in the range 0.0-2.2 eV. The detection sensitivity is below 1 part-per-trillion, with a calculated conversion rate of 1.3 percent. Signal nonlinearity is discussed in terms of ion space-charge effects. The device also produces positive ions, and an analogous treatment may be carried through to characterize its performance in this mode.

Boumsellek, S.↗

Determination of geometric distortion in STIS images

This is a report on the characterization of the geometric distortion of the Space Telescope Imaging Spectrograph (STIS) Charge Coupled Devices (CCD) and the STIS Far-Ultraviolet Multi-Anode Microchannel Arrays (FUV-MAMA) detectors when used in imaging mode. We find that the amount of the distortion is fairly small over most of the field. The maximum displacement is 1.66 pixels for the CCD and 2.71 pixels for the FUV-MAMA. This data also allows us to determine the plate scale for both cameras. For the CCD the scale is 0".05071 +/- 0".00007 /pixel. For the FUV-MAMA the scale is 0".02447 +/- 0".00001 /pixel in x and 0".02467 +/-0".00002 /pixel in y.

Malumuth, Eliot M.↗

Breakdown Degradation Associated with Elementary Screw Dislocations in 4H-SiC P(+)N Junction Rectifiers

It is well-known that SiC wafer quality deficiencies are delaying the realization of outstandingly superior 4H-SiC power electronics. While efforts to date have centered on eradicating micropipes (i.e., hollow core super-screw dislocations with Burgers vector greater than 2c), 4H-SiC wafers and epilayers also contain elementary screw dislocations (i.e., Burgers vector = lc with no hollow core) in densities on the order of thousands per sq cm, nearly 100-fold micropipe densities. This paper describes an initial study into the impact of elementary screw dislocations on the reverse-bias current-voltage (I-V) characteristics of 4H-SiC p(+)n diodes. First, Synchrotron White Beam X-ray Topography (SWBXT) was employed to map the exact locations of elementary screw dislocations within small-area 4H-SiC p(+)n mesa diodes. Then the high-field reverse leakage and breakdown properties of these diodes were subsequently characterized on a probing station outfitted with a dark box and video camera. Most devices without screw dislocations exhibited excellent characteristics, with no detectable leakage current prior to breakdown, a sharp breakdown I-V knee, and no visible concentration of breakdown current. In contrast devices that contained at least one elementary screw dislocation exhibited a 5% to 35% reduction in breakdown voltage, a softer breakdown I-V knee, and visible microplasmas in which highly localized breakdown current was concentrated. The locations of observed breakdown microplasmas corresponded exactly to the locations of elementary screw dislocations identified by SWBXT mapping. While not as detrimental to SiC device performance as micropipes, the undesirable breakdown characteristics of elementary screw dislocations could nevertheless adversely affect the performance and reliability of 4H-SiC power devices.

Neudeck, P. G.↗